KTI Networks KC-220FF-TSA, KC-220FF-TS3, KC-220FF-TS5, KC-220FF-CSA, KC-220FF-CS3 Installation Manual

...
Specifications
 Complies with IEEE 802.3u 100BASE -FX std.  Operates with connected devices running on full duplex
or half duplex mode
 Environment: Temperature 0 - 40oC
Humidity 10-90% non condensing  Dimensions: 101mm x 96mm x 25mm  Power: +12V / 800mA minimum
 DC plug type:
Connectors & Cables
The converter provides one multimode (MM) fiber port and one single mode (SM) fiber port as shown below:
The multimode fiber port is used for a duplex multimode fiber cable connection and single mode fiber port is used for a duplex single mode fiber cable connection.
Both ports are compliant to IEEE 802.3u 100BASE-FX standard and can convert multimode optic signal to single mode optic signal up to bandwidth 200Mbps transpar­ently with a minimal delay time.
The wavelength used is 1300nm for both ports. The recommended MM (Multimode fiber) cable is 62.5/125mm and SM (Single Mode fiber) cable is 9/125mm.
General Description
The KC-220FF Fast Ethernet media converter series are de­signed to convert a 100BASE-FX multimode fiber signal to single mode fiber signal. It is used to extend the connection distance between two Fast Ethernet fiber optic devices via single mode fiber cable transparently with no performance degradation. The converter series provide different types of fiber connectors such as ST, SC, and MT-RJ for MM (multi­mode) or SM (single mode) fiber cables.
The outline of the converter is:
Installation Guide
100BASE-FX Multimode-Single mode
Media Converter
KC-220FF SERIES
DOC. 010430-KC220FF-K Rev.1.0
P/N: 750-0155-001
The series provides different types of fiber connectors for different applications. The connectors include ST, SC, and MT-RJ. The following figure illustrates the available combinations:
The following table lists the fiber connectors, fiber cables and the maximum length supported by each converter model:
Model MM Port* SM Port SM Cable Length*
KC-220FF-TSA ST SC 15Km KC-220FF-TS3 ST SC 30Km KC-220FF-TS5 ST SC 50Km KC-220FF-CSA SC SC 15Km KC-220FF-CS3 SC SC 30Km KC-220FF-CS5 SC SC 50Km KC-220FF-CJ SC MT-RJ 15Km KC-220FF-JJ MT-RJ MT-RJ 15Km KC-220FF-JSA MT-RJ SC 15Km
* MM Port : the maximum MM cable length is 2K meters. * SM Cable length : the maximum length in point-to-point full duplex operation
The information contained in this document is subject to change without prior notice. Copyright+ KTI. All Rights Reserved.
TRADEMARKS
Ethernet is a registered trademark of Xerox Corp.
WARNING:
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protec­tion against harmful interference when the equipment is operated in a commercial environment. This equipment gener­ates, uses, and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference in which case the user will be required to correct the interference at his own expense.
NOTICE:
(1) The changes or modifications not expressively approved by the party responsible for compliance could void the user's authority to operate the equipment. (2) Shielded interface cables and AC power cord, if any, must be used in order to comply with the emission limits.
CISPR A COMPLIANCE:
This device complies with EMC directive of the European Community and meets or exceeds the following technical standard. EN 55022 - Limits and Methods of Measurement of Radio Interference Characteristics of Information Technology Equip­ment. This device complies with CISPR Class A. WARNING: This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
CE NOTICE Marking by the symbol indicates compliance of this
equipment to the EMC directive of the European Community. Such marking is indicative that this equipment meets or exceeds the following technical standards: EN 55022: Limits and Methods of Measurement of Radio Interference characteristics of Information Technology Equip­ment. EN 50082/1:Generic Immunity Standard -Part 1: Domestic Commercial and Light Industry. EN 60555-2: Disturbances in supply systems caused by household appliances and similar electrical equipment - Part 2: Harmonics.
Installation
1. Install the media converter with the DC power adapter provided. ( +12VDC, 800mA)
2. Connect the power adapter cable to the media con­verter before connecting the adapter to the AC outlet.
Making Network Connections
The converters serve as a conversion path between two Fast Ethernet Multimode fiber devices. To both devices, the conversion is transparent.
Important rule: When a connection is established, make sure the devices located at both ends of the path are configured and operated using the same duplex mode and the maximum distance must comply with IEEE 802.3u specifications.
Interpreting LED Indicators
LED Status State Interpretation
POWER Power status On Converter is on.
Of f Converter is off.
MM MM port link On The MM fiber link is ok.
Off No link or the link is faulty.
SM SM port link On The SM fiber link is ok.
Off No link or the link is faulty.