-6-
Note:
1. For connecting to early 1000BASE-X devices which do not provide
auto negotiation capability, you might need to set the SW to NONAUTO position to prevent unexpected link failure occurrence.
2. In most of the cases, setting AUTO would make the link worked.
3. When installing two of these converters on both ends of a fiber
connection, set the switch to NON-AUTO (forced full duplex mode)
to achieve the best performance.
Model Fiber Wavelength Output power Input Sensitivity
210TF-SXC SX 850nm -9.5 ~ -4 dBm -12.5dBm max.
210TF-SXC-O SX 850nm -9.5 ~ -4 dBm -18dBm max.
210TF-LXC LX 1310nm -9.5 ~ -3 dBm -14.4dBm min.
210TF-LXC-O LX 1310nm -9 ~ -3 dBm -21dBm min.
210TF-LXC30-O LX 1310nm -5 ~ 0 dBm -24dBm min.
210TF-LXC40 LX 1550nm DFB -5 ~ 0 dBm -24 dBm max.
210TF-LXC80 LX 1550nm DFB -2 ~ 3 dBm -24 dBm max.
Model Fiber Used Cable Length
210TF-SXC MMF 62.5/125 220 meters
MMF 50/125 500 meters
210TF-SXC-O MMF 62.5/125 300 meters
MMF 50/125 500 meters
210TF-LXC MMF 62.5/125 550 meters
MMF 50/125 550 meters MM: Multimode
SMF 9/125 10Km SM: Single mode
210TF-LXC-O SMF 9/125 10Km
210TF-LXC30-O SMF 9/125 30Km
210TF-LXC40 SMF 9/125 40 ~ 50Km
210TF-LXC80 SMF 9/125 80Km