Thank you for choosing our high quality camera. Before attempting
to connect operate this unit,please read and follow these instructions.
Page 2
CAUTION
These servicing instructions are for use by qualied service personnel only.
To reduce the risk of electric shock do not perform any servicing other than
that contained in the operating instructions unless you are qualied to do so.
Use Class 2 Power Supply Only
2
Page 3
CONTENTS
1. CAUTIONS
2. IMPORTANT SAFETY INSTRUCTIONS
3. FEATURES
4. COMPONENTS
5. NAME AND FUNCTION
6. INSTALLATION
7. DIMENSIONS
8. SPECIFICATION
9. OSD MANUAL
10. COMMUNICATION PROTOCOL
3
Page 4
1. CAUTIONS
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions;
1. This device may not cause harmful interference.
2. This device must accept any interference received, including
interference that may cause undesired operation.
Note
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated
in a commercial environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the instruction
manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.”
WARNING
This is a class A product. In a domestic environment this product may cause radio
interference in which case the user may be required to take adequate measures.
Caution
Any changes or modications in construction of this device which are not expressly
approved by the party responsible for compliance could void the user’s authority to
operate the equipment.
1. A regulated DC12V 1A power supply is recommended for use with this camera
for the best picture and the most stable operation.
An unregulated power supply can cause damage to the camera.
When unregulated power supply is applied, product warranty will be
out of subject.
2. It is recommended that the camera is used with a monitor that has a CCTV quality
75 video impedance level.
If your monitor is switched to high impedance then please adjust accordingly.
3. Do not attempt to disassemble the camera to gain access to the internal componets.
Refer servicing to your dealer.
4. Never face the camera towards the sun or any bright or reective light, which may
cause smear on the picture and possible damage to the CCD.
5. Do not remove the serial sticker for the warranty service.
4
Page 5
1. CAUTIONS
Correct Disposal of This Product
(Waste Electrical & Electronic Equipment)
(Applicable in the European Union and other European countries with
separate collection systems)
This marking shown on the product or its literature, indicate that it should not
be disposed with other household wastes at the end of its working life. To
prevent possible harm to the environment or human health from uncontrolled
waste disposal, please separate this from other types of wastes and recycle it
responsibly to promote the sustainable reuse of material resources.
This product should not be mixed with other commercial wastes purchased this
product, or their local government ofce, for details of where and how they can
take item for environmentally safe recycling.
Business users should contact their supplier and check the terms and
conditions of the purchase contract.
Household users should contact either the retailer where they for disposal.
CAUTION
RISK OF ELECTRIC SHOCK DO NOT OPEN
CAUTION:
TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT
REMOVE COVER (OR BACK). NO USER. SERVICEABLE
PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE
PERSONNEL
This symbol is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that
may be of sufcient magnitude to constitute a risk of electric shock
to persons.
This symbol is intended to alert the user to the presence of
important operating and maintenance (servicing) instructions in the
literature accompanying the appliance.
5
Page 6
2. IMPORTANT SAFETY INSTRUCTION
1) Read these instructions.
2) Keep these instructions.
3) Heed all warnings.
4) Follow all instructions.
5) Do not use this apparatus near water.
6) Clean only with dry cloth.
7) Do not block any ventilation openings. Install in accordance
with the manufacturer’s instructions.
8) Do not install near any heat sources such as radiators, heat registers,
stoves, or other apparatus (including ampliers) that produce heat.
9) Do not defeat the safety purpose of the polarized or grounding-type plug. A
polarized plug has two blades with one wider than the other. A grounding type plug
has two blades and a third grounding prong. The wide blade or the third prong are
provided for your safety. If the provided plug does not t into your outlet, consult an
electrician for replacement of the obsolete outlet.
10) Protect the power cord from being walked on or pinched particularly at plugs,
convenience receptacles, and the point where they exit from the apparatus.
11) Only use attachments/accessories specied by the manufacturer.
12) Use only with the cart, stand, tripod, bracket, or table specied by the
manufacturer, or sold with the apparatus. When a cart is used,
use caution when moving the cart/apparatus combination to
avoid injury from tip-over.
13) Unplug this apparatus during lightning storms or when unused for long
periods of time.
14) Refer all servicing to qualied service personnel. Servicing is required when
the apparatus has been damaged in any way, such as power-supply cord or plug
is damaged, liquid has been spilled or objects have fallen into the apparatus, the
apparatus has been exposed to rain or moisture, does not operate normally, or has
been dropped.
• ATR(Adaptive Tone-curve Reproduction / Digital WDR)
The function provides gradation compensation to improve the contrast of subjects both
low-luminance areas and high luminance areas exist in the same picture
4. COMPONENTS
SUPER NIGHT VISION CAMERA
VIDEO OUTPUT
TEST CABLE
L-WRENCH / SCREW - 4ea
OPERATION MANUAL
7
Page 8
5. NAME AND FUNCTION
①
②
①
Sunshield
②
Cable Concealed
Thru Bracket
③
LED : 10ea
④
Photo cell
⑤
Body
③ ④⑤
• CONTROL FUNCTION / SERVICE VIDEO CONNECTOR
• CONTROL FUNCTION
(OSD JOYSTICK)
LEFT
MENU
UP
RIGHT
DOWN
HANDHELD MONITOR
• SERVICE VIDEO CONNECTOR
8
Page 9
5. NAME AND FUNCTION
• Heater
Heater
Built in heater protects the camera from low temperature.
(Operating temperature with Heater:-40℃)
• External Zoom & Focus Adjustable
External Zoom & Focus Adjustable
9
Page 10
6. INSTALLATION
• MOUNTING POSITION
90˚TLIT
90˚TLIT
360˚PAN
360˚PAN
10
Page 11
6. INSTALLATION
• MONITOR CONNECTION
DUAL(DC12V/AC24V)
DC12V/AC24V
DC12V/AC24V
BNC FEMALE
DC 12V POWER SUPPLY or
AC 24V POWER SUPPLY
VIDEO IN MONITOR
DC 12V POWER SUPPLY or
AC 24V POWER SUPPLY
VIDEO IN
MONITOR
DC12V
When you install the camera, please glue up the
end of cable to keep it stable in order to protect the
camera from the humidity problems.
DC12V
BNC FEMALE
DC12V
BNC FEMALE
11
RS485
DC 12V POWER SUPPLY
VIDEO IN
MONITOR
DC 12V POWER SUPPLY
VIDEO IN
MONITOR
RS485
Page 12
7. DIMENSIONS
Unit : mm
10 POWER LED
Photo
cell
98.6
140
83.0
89.5
126.0
M12XP1.25
(256.5)
12
Ø95
(2EA)
106.5
10
135
125
Page 13
8. SPECIFICATION
Signal FormatNTSCPAL
Image Device1/3˝ 960H SONY EXview HAD CCD II
Scanning System2 : 1 Interlace
Scanning Frequency15.734KHz(H), 59.94Hz(V)15.625KHz(H), 50Hz(V)
Total Pixels1020(H) X 508(V)1020(H) X 596(V)
Effective Pixels976(H) X 494(V)976(H) X 582(V)
Electronic Shutter Speed1/60 sec1/50 sec
H.Resolution750TV Lines
S/N RatioMore than 50dB (AGC OFF)
Min.IlluminationLED On : 0 Lux
Sync SystemInternal
Gammar= 0.45
Video Output Level1.0 Vp-p Composite(75Ω)
OSDBuilt in (Joystick)
BLCOFF / BLC / HLC
2DNROFF / ON (Level adjustable)
ATROFF / ON (Level adjustable)
SMART IROn / Off
White BalanceATW / PUSH / MANUAL / PUSH-LOCK
Privacy Masking4 Zones
Motion Detection4 Zones
Day & Night(ICR)AUTO / Color / BW
Language
IP RatingIP67 (Water proof)
IR LEDHI POWER LED, 10EA
IR LED DistanceUp to 70M
Operating Temperature14°F~122°F(-10°C~+50°C) / Heater On: -40°F~122°F(-40°C~+50°C)
Storage Temperature-4°F~140°F(-20°C~+60°C)
HumidityLess than 80%
Power Consumption
LensVerifocal Auto Iris & DN Lens
Dimension98.6(W) x 83(H) x 126(D)
WeightApprox.1.37Kg
OptionRS-485, Heater
Specications and designs are subject to change for improving the functionality of this product without notice.
>FOCUS ADJUST [┛]
EXPOSURE [┛]
WHITE BALANCE [┛]
BLC [┛]
DAY&NIGHT [┛]
IMAGE [┛]
SPECIAL [┛]
FACTORY DEFAULT
EXIT
FOCUS ADJUST
FOCUS VALUE: 28
>FOCUS WINDOW ON
RETURN
EXPOSURE
>BRIGHTNESS
SHUTTER
FLICKERLESS
AGC MAX
INITIAL
RETURN
> WB MODE ATW
RED CONTROL --- BLUE CONTROL --- PUSH AUTO --- INITIAL
RETURN
WHITE BALANCE
...
7
...
1/60
...
OFF
...
30dB
BLC
>ATR MODE ON
ATR LEVEL 4
BLC MODE ON
BLC ZONE CENTER
BLC LEVEL 8
INITIAL
RETURN
DAY & NIGHT
>D&N MODE AUTO
DWELL TIME 3SEC
D -> N LEVEL 1
N -> D LEVEL 3
BURST OFF
IR OPTIMIZER ON
IR OPT.LEVEL 8
LED CONTROL MANUAL
LED LEVEL 15
INITIAL
RETURN
14
Page 15
9. OSD MANUAL
IMAGE
>MIRROR OFF
DNR ON
DNR LEVEL 4
SHARPNESS 8
INITIAL
RETURN
SPECIAL
>CAM TITLE [┛]
LANGUAGE ENGLISH
COMM ADJUST [┛]
PRIVACY [┛]
MOTION DETECT [┛]
DISPLAY [┛]
DEFECT
INITIAL
RETURN
CAM TITLE
0123456789ABCDEFGHIJK
LMNOPQRSTUVWXYZ!()<>
SPA
>> <<BAK
TITLE SET
LOCATION [┛]
RETURN
COMM ADJUST
> CAM ID 1
BAUDRATE 9600
RETURN
PRIVACY
MOTION DETECT
0
ON
0
>ZONE NO
MASK MODE
V START 7
V END 12
H START 10
H END 19
COLOR 1
TRANSPARENCY 0%
MOSAIC OFF
INITIAL
RETURN
>ZONE NO
MOTION MODE ON
LEVEL 4
V START 7
V END 12
H START 10
H END 19
INITIAL
RETURN
DISPLAY
> CAM ID
CAM TITLE
MOTION DETECT ON
INITIAL
RETURN
DEFECT
> COMPENSATION ON
DETECTION (
RETURN
↓
ON
ON
)
[TITLE LOCATION]
TITLE
[U] [D] [L] [R] [M] <
15
Page 16
9. OSD MANUAL
MAIN MENU Sub MenuSub MENU
SETUP
FOCUS ADJUST
EXPOSURE
WHITE BALANCE
BLC
DAY&NIGHT
IMAGE
FOCUS WINDOW
RETURN
BRIGHTNESS0~15
SHUTTER
FLICKERLESS
AGC MAX6dB, 9dB, 12dB, 15dB, 18dB, 21dB, 24dB, 27dB, 30dB, 33dB, 36dB, 39dB, 42dB
INITIAL
RETURN
WB MODE
RED CONTROL
BLUE CONTROL
PUSH AUTO
INITIAL
RETURN
ATR MODE
ATR LEVEL
BLC MODE
BLC ZONE
BLC LEVEL
INITIAL
RETURN
D&N MODE
DWELL TIME
D -> N LEVEL
N -> D LEVEL
BURST
IR OPTIMIZER
IR OPT.LEVEL
LED CONTROL
LED LEVEL
INITIAL
RETURN
MIRROR
DNR
DNR LEVEL
SHARPNESS