Megapixel Network Camera
PLASTIC DOME
Table of Contents
1.INTRODUCTION
2.PACKAGE CONTENTS
3.PRODUCT DESCRIPTION
4.INSTALL THE HARDWARE
5.ASSIGN AN IP ADDRESS
6.PRODUCT SPECIFICATIONS
Installation Guide
VANDAL DOME
M174-LD(V)i40-001
3. Product Description
Description and function
Plastic Dome Type: Vandal Dome Type:
➊
➎
➋
➌
➍
➐
➏
4. Install the hardware
IP camera are designed to be installed using a template as shown below.
Plastic Dome Type
1. Attach the FLAT DOME on the ceiling with using the screws provided, considering the camera
angle required for the surveillance function.
2. Adjust the LENS ANGLE to the desired location by hand.
3. Connect the VIDEO OUT CABLE and check the video image. Change the SETTINGS accordingly
using the OSD controller.
<TILT ANGLE : 20~90°>
TILT: 0°
TILT: +90°
<PAN ANGLE : ±10°>
PAN: ±10°
PAN: 0°
4. After the LENS SETTING is completed, install the TOP COVER.
TOP HOUSING
(Assembly direction)
TILT: +20°
Micro SD Slot
ASSEMBLY HOOK
(2 point)
TOP HOUSING
(Separation Direction)
* FIXED TAPE: It attached when you install the
product in areas where vibration occurs.
FIXED TAPE attached examples.
TILT 45° when attaching TILT 90° when attaching
M4 STAR SCREW
TAPPING SCREW
(4 x 20L) - 3EA
1. Introduction
IP Dome Camera Installation Guide
This installation guide provides instructions for installing the Network Camera on your
network. For all other aspects of using the product, please see the User’s Manual,
available on the CD included in this package.
Installation steps
1. Check the package contents against the list below.
2. Product description.
3. Install the hardware.
4. Set an IP address.
5. Set the admin and user ID and password, See User’s Manual.
Important!
This product must be used in compliance with local laws and regulations.
2. Package Contents
1. Reset Button – Press the reset switch for more than 10 seconds,
the restore the camera to the function default settings.
2. Service Video Connector – Outputs video to the monitor.
3. Status LED
4. Micro SD Card Socket.
5. NTSC / PAL Toggle Switch.
6. Power Input(DC12V) – Connect DC 12V power.
7. Network Connector –
The Network Camera connects to the network via a standard network cable, and
automatically detects the speed of the local network segment
(10BaseT/100BaseTX Ethernet). PoE Supported
Connection
Vandal Dome Type
1. Attach the FLAT DOME on the ceiling with using the screws provided, considering the camera
angle required for the surveillance function.
2. Adjust the LENS ANGLE to the desired ocation by hand.
3. Please remove the protective lm when installing.
TAPPING SCREW
(4 x 20L)-3EA
* Protective lm
4. Connect the VIDEO OUT CABLE and check the video image.
Change the SETTINGS accordingly using the OSD controller.
Micro SD Slot
5. After the LENS SETTING is completed, install the TOP COVER.
* FIXED TAPE: It attached when you install the
product in areas where vibration occurs.
FIXED TAPE attached examples.
TILT 45° when attaching TILT 90° when attaching
* FIXED TAPE
L-WRENCH(T-20)
<TILT ANGLE : 20~90°>
TILT: +90°
<PAN ANGLE : ±10°>
PAN: ±10°
PAN: 0°
TILT: 0°
TILT: +20°
Plastic Dome Type Vandal Dome Type Video Output Test Cable / Fixed Tape
Installation Guide Template Software CD Screws / L-Wrench
1. Connect the camera to the network using a UTP cable (CAT.5), Power can be supplied via
the network cable (PoE)
2. Connect DC 12V to the power terminal. This is not necessary if the Network Camera is
connected to PoE hub or midspan.
3. Check that the indicator LEDs indicates the correct conditions.
4. Connect the analog monitor to the service video connector for adjusting focus and press and quickly
release the reset switch for focus assistant mode.
Then you can select normal view or focus view mode using the reset switch.
Caution: When you use focus assistant mode, “Focus View” mode is recommended for more exact focus.
Caution: Focus assistant mode will be automatically exited after 3 minutes for normal operation.
*CASE RUBBER:
Before assembling the top housing,
Be sure the Rubber correctly positioned.
M4 STAR SCREW
L-WRENCH(T-20)
5. Assign an IP address
To make it accessible on the network, the Network Camera must be assigned an IP address.
Note:
•
A network DHCP server is optional.
•
The Network Camera has the default IP address 192.168.0.123.
•
If IP assignment fails, check that there is no firewall blocking its operation and check that the Network
Camera and your computer's IP is located on the same subnet.
Accessing the Network Camera
1. Start your browser(when you rst run ActiveX to install, run an “IE as Administrator” on Window 7 or Vista).
2. Enter the IP address or host name of the Network Camera in the Address eld of your browser.
8. The video image displays in your browser.
Assign an IP address using IP Installer
IP installer automatically search and display network devices on your
network. The application can also be used to manually assign a static IP address.
Note:
The computer running the IP installer must be on the same network segment (physical subnet) as the Network
Camera.
1. Check that the Network Camera is connected to the network and that power has been applied.
2. Start NetCAM installer.
3. When the Network Camera is displayed as shown above, select the unit that need to be assigned
an IP.
A. Refresh Device List – Rescan local network to nd the Network Camera.
B. Authenticate – Enter the administrator ID and password.
* Default User ID and Password is [ID: admin, Password: admin]
C. Host Name – Enter the Host Name of the Network Camera.
D. IP Settings
i. Dynamic – Assign dynamic IP address automatically from DHCP server on your network.
ii. Static – Assign static IP address manually.
iii. Port – Enter the HTTP port the Network Camera will use. The default setting is 80.
Alternatively, any port in the range 1024-65535 may be used, but check rst with your
system administrator before changing the default setting.
E. Network Settings
i. Subnet Mask – Specify the mask for the subnet the Network Camera located on.
ii. Gateway – Specify the IP address of the default router (gateway) used for connecting devices
attached to different networks and network segments.
iii. Pri. DNS – Enter the IP address of the primary DNS server. This server provides the
translation of host names to IP addresses on your network.
iv. Sec. DNS – Specify the IP address of the secondary DNS server. This will be used if the
primary DNS server is unavailable.
3. If you are accessing the Network Camera for the rst time, you will see the following warning
message as shown below.
4. Click the warning message and select “Install ActiveX Control…”.
5. Click “Install” to install the Web Viewer.
6. If a Windows Security Alert pop-up appears, click “Unblock”.
7. After installing the Web View ActiveX Control, a Login page will be displayed.
Enter the user ID and password.
Note:
Default User ID and Password is [ID: admin, Password: admin]
Note:
To view streaming video in Microsoft Internet Explorer, you must set your browser to allow the “Web Viewer” to be
installed on your computer. This ActiveX component is installed the first time a video stream is accessed.
6. Product Specications
ITEM DESCRIPTION
Image Device 2.1 Mega Pixel 1/3” SONY Progressive CMOS
Lens(Unit: mm) Board Lens
Minimum Illumination 0.1 lux
Video Codec H.264 Main Prole, Motion JPEG
Video
Network
General
Dimensions
Resolutions
(H.264/MJPEG)
Video Streaming
Image Settings
Security
Supported
Protocols
Enclosure Plastic case, Alloy case
Power
Interfaces
Operating
Conditions
IP Rating Vandal Dome : IP66 (Weatherproof)
Dimension(mm)
Weight
(Unit:mm)
• Plastic Dome Type • Vandal Dome Type
H.264 : MAX 1920x1080 + Analog Output @ 30fps
MJPEG : MAX 1280x720 @30fps
Multi Streaming VBR / CRB
(Controllable Frame Rate and Bandwidth)
Brightness, Contrast, Saturation, Sharpness, White Balance,
Exposure Control, Compensation, Privacy mask, BLC, 3D DNR
Multiple user access levels with password protection
HTTPS (SSL)
IPv4, HTTP, HTTPS, TCP, RTSP, RTP, UDP, IGMP, RTCP,
SMTP, FTP, ICMP, DHCP, ARP, DNS, DDNS, HTTPS, UPnP
DC12V(±10%), Max. 200mA
Power over Ethernet Class 3 (IEEE 802.3af)
RJ-45 for Ethernet 10baseT/100baseTX with PoE
3.5mm Power Input: DC 12V, connector for Service Video
SD Card Socket, NTSC / PAL Toggle Switch
Temperature: - 10°C ~ +50°C (14°F ~ 122F°)
Humidity 20-80% RH (non-condensing)
Plastic Dome Type : 119 x 119 x 42
Vandal Dome Type : 139 x 134 x 49
Plastic Dome Type : 160g
Vandal Dome Type : 440g
119
134
4. Click the “Set” button to save conguration.
119
139
42
49