2.4. Safety Precautions for Gasoline Powered Generator Operation 4
3. SAFETY SYMBOLS 5
3.1. Description of safety symbols when operating the generator 5
4. DESCRIPTION OF GENERATOR INSCRIPTIONS 6
5. GENERAL VIEW AND COMPOSITION
OF THE GASOLINE POWERED GENERATOR 7
6. GENERATOR SPECIFICATIONS 8-9
7. GENERATOR DELIVERY PACKAGE 10
8. CONTROL PANELS 10
9. COMMISSIONING 11
10. GETTING STARTED 11
10.1. Checking the fuel level 11
10.2. Checking the oil level 11
11. ENGINE START 12
11.1. Gasoline Powered Generator Engine Start 12
12. ENGINE STOP 13
12.1. Gasoline Powered Generator Stop 13
13. MAINTENANCE 13
14. RECOMMENDED MAINTENANCE SCHEDULE 14
15. SPARK PLUG MAINTENANCE 14
16. RECOMMENDED OILS 15
17. AIR FILTER MAINTENANCE 16
18. GENERATOR STORAGE 17
19. GENERATOR TRANSPORTATION 17
20. GENERATOR DISPOSAL 17
21. TROUBLESHOOTING 18
22. AVERAGE POWER RATINGS OF DEVICES 19
WARRANTY PROVISIONS 20
1
Page 3
1. PREFACE
Thank you for your purchase of K&S Basic generator. This owner’s manual
contains safety instructions, a description of the use and commissioning of K&S
Basic generators and procedures for their maintenance.
The generator manufacturer may make some modications that may not be
reected in this manual. The manufacturer reserves the right to make changes
in the product design, conguration and construction. The images and drawings
in this manual are for reference only and may dier from the actual components
and inscriptions on the products.
Contact information that you are free to use in case of any problems can be found
at the end of this manual. All information in this manual is correct to the best of
our knowledge and belief at the date of its publication. The current list of service
centers can be found on the ocial importer's website: www.ks-power.de/en
WARNING - DANGER!
!!
Please read this manual carefully before rst in order to ensure
equipment integrity and avoid possible injuries.
ABBREVIATIONS
KS -K&S Basic electric generator
А- Aluminum alternator winding
С- Copper winding
Please read this manual carefully. Pay particular attention to information that
starts with characters/words:
WARNING - DANGER!
!!
Failure to observe the recommendation indicated by this sign may result in
serious injury or death to the operator or unauthorized persons.
PLEASE NOTE!
!!
Useful information on the use of the device.
2. SAFETY PRECAUTIONS
2.1. WORK AREA
- The generator must not be used in premises with poor ventilation since exhaust
gases contain poisonous carbon monoxide, which is life threatening!
- Do not use the generator in the rain, snow and high humidity. Do not touch
the generator with wet hands and expose to direct sunlight for a long time. It
2
Page 4
is recommended to store and use the generator indoors or in well-ventilated
premises.
- Always install the generator on a at solid horizontal surface. The generator is
equipped with dampers to reduce vibration during operation and avoid damage to
the surface where the generator is installed.
- Do not use the generator near ammable gases, liquids or dust. During operation
of the generator, its exhaust system becomes very hot. This may cause re or
explosion of these materials.
- Keep the work area clean and well lit to avoid injuries.
- Keep unauthorized persons, children and animals away from the running
generator.
- Always wear protective shoes and protective gloves when operating the
generator.
2.2. ELECTRICAL SAFETY
УВАГА - НЕБЕЗПЕЧНО!
!!
The device generates electricity. Observe safety precautions to
avoid electric shock.
- The wiring diagram for the generator must comply with the installation
rules and applicable statutory requirements.
- All wiring connections of the generator must be carried out by a certied
electrician in accordance with all electrical codes and regulations.
- Avoid the generator supply from the mains during restoration of the power
supply.
- Avoid operating the generator in high-humidity environments. Do not allow
moisture to enter the generator, as this increases the risk of electric shock.
- Avoid direct contact with grounded surfaces (pipes, radiators, etc.).
- Be careful when working with the power cord. Replace it immediately in
case of damage, as damaged power cord increases the risk of electric shock.
- All connections of the generator to the mains must be carried out by a
certied electrician.
- Connect the electric generator to the protective ground before operation
using the terminal located on the generator control panel.
- Do not connect/disconnect the generator to/from power consumers while
standing in water, on wet or damp soil.
- Do not touch live parts of the generator.
- Only connect the generator to the power consumers that correspond to the
electrical specications and power rating of the generator.
- Keep all electrical equipment dry and clean. Replace damaged or worn
wiring. Worn, damaged, or rusted terminals must be replaced as well.
2.3. PERSONAL SAFETY
- Do not operate the generator when you are tired or under the inuence of potent
drugs, alcohol or medication. During operation, inattention can cause serious injury.
- Avoid inadvertent start-up. Make sure the power switch is set to OFF when turning
o the generator.
3
Page 5
WARNING - DANGER!
!!
Failure to comply with these requirements may result in re or explosion of
the generator, as well as re in the building wiring.
- Do not operate the generator in areas with poor ventilation. Exhaust gases contain
poisonous carbon monoxide, which is life threatening!
- Make sure there are no foreign objects on the generator when it is turned on. Use
the product for its intended purpose only. The generator customer using the device for
other than the intended purpose shall be deprived of the right to free warranty repair.
Do not sit, stand on the generator and misuse the equipment.
- Always keep proper footing and balance when starting the generator.
- Do not overload the generator, use it for its intended purpose only.
2.4. SAFETY PRECAUTIONS FOR GASOLINE POWERED GENERATOR OPERATION
Please note the following:
- Do not start the generator when it is under load.
- The generator must be installed at least 1 m away from explosive and ammable
substances and objects since its engine heats up during operation.
- Do not ll the fuel tank when the engine is running.
- Do not smoke while refueling.
- For the generator, A-92 gasoline is recommended. After lling the tank, remove all
excess fuel from the surface. Do not use kerosene or other fuel. Otherwise, the engine
may be damaged.
- Observe the fuel tank while lling in order to avoid overlling.
- Do not touch the exhaust system after starting the generator and during its
operation.
- Avoid operating the generator near water, in the rain or snow if there is a risk of it
becoming wet.
- Before starting the generator, learn how to stop the generator in case of an
emergency.
WARNING - DANGER!
!!
Fuel pollutes soil and groundwater. Avoid gasoline leaking out
of the fuel tank!
4
Page 6
3.
SAFETY SYMBOLS
3.1. DESCRIPTION OF SAFETY SYMBOLS WHEN OPERATING THE GENERATOR
Fig. 1
1
2
abcd
12
efgh
a. Be careful when operating the device! Observe
the safety instructions in this manual.
b. Operate the generator only in well-ventilated
indoor spaces or outdoors. Exhaust gases contain
СО2, whose vapors are life threatening.
c. Do not operate or store the device in highhumidity environments.
d. Do not smoke while operating the generator!
e. The device generates electricity. Observe
safety precautions to avoid electric shock.
f. Read this owner’s manual carefully before
operating the device.
g. Do not touch the generator with wet or dirty
hands.
h. Observe re safety regulations, do not operate
the generator near open ame.
i. Do not touch! The generator dampener
becomes hot during operation.
Fig. 2
i
5
Page 7
4. DESCRIPTION OF GENERATOR
INSCRIPTIONS
APART FROM THE SAFETY SYMBOLS, THE GENERATOR CONTAINS THE FOLLOWING
INSCRIPTIONS:
Specications chart. Specications vary
from model to model. For more information,
see “Generator Specications”.
Noise level information for each model can be found in the
specications chart.
Indicates the direction of opening the air
choke.
Indicates the position of the fuel valve. The “ON” position means
open and the “OFF” position means closed.
Fuel level indicator. The icon on the left
indicates that the fuel tank is full, and the
icon on the right indicates that the fuel tank
is empty.
Crankcase capacity
(varies from model to model)
Recommended oils.
Maintenance information in the language of the country where the generator is
sold can be found in the “Maintenance” section.
Note on the required
oil level in the crankcase
Ground
6
Page 8
5. GENERAL VIEW AND COMPOSITION OF
THE GASOLINE POWERED GENERATOR
8
7
11
9
1
Fig. 3
2
6
5
4
3
12
10
1. Fuel cap
2. Control panel
3. Oil dipstick
4. Oil drain cap
5. Hand starter
6. Fuel valve
!!
The manufacturer reserves the right to make changes in the product
design, conguration and construction. Illustrations in this manual
are for reference only and may dier from actual components and
- You can use the generator if the voltmeter indicates a value of 230 V ±10%
(50 Нz).
- Monitor the voltmeter and stop the generator if the value is too high.
- Avoid using 12 V voltage simultaneously with 230 V.
10
Page 12
9. COMMISSIONING
The generator is supplied without fuel. Before use, be sure to ll the fuel tank.
Recommendations for refueling are listed below. The generator is supplied
without motor oil. The generator crankcase may contain oil residues after
factory tests. Be sure to add oil before use. Recommendations for oils and lling
procedure are given below.
To commission the generator, follow the maintenance recommendations for the
rst month or twenty hours of operation (whichever comes rst) contained in
the “Maintenance” section.
10. GETTING STARTED
10.1. CHECKING THE FUEL LEVEL
1. Wear protective gloves to avoid getting gasoline on your skin.
2. Unscrew the fuel cap and check the fuel level in the tank.
3. Fill the fuel tank to the fuel lter level.
4. Tighten the fuel cap securely.
Fuel cap
Fig. 5
PLEASE NOTE!
!!
For the generator, A-92 gasoline is recommended. Using other fuels may
10.2. CHECKING THE OIL LEVEL
1. Wear protective gloves to avoid getting oil on
your skin.
2. Unscrew the oil dipstick and wipe it out with a
clean cloth.
3. Insert the dipstick without screwing it in.
4. Check the oil level by a mark on the oil dipstick.
5. Add oil if its level is below the mark on the oil
dipstick.
6. Tighten the oil dipstick.
If the generator has not been used for a long time, recharge the
cause damage to the engine.
PLEASE NOTE!
!!
battery with a charger (not included).
11
Fig. 6
Page 13
11. ENGINE START
WARNING - DANGER!
!!
Before starting the engine make sure that the total power of tools or
power consumers corresponds to the rated power of the generator.
Do not exceed the rated power of the generator. Do not connect
any devices before the engine start! In the power supply mode, the
generator should operate no longer than 30 minutes in the range
from rated to maximum power.
Before connecting any devices to the generator, make sure that they are in
good condition. If the device that was connected suddenly stopped or failed,
immediately disconnect the power using a safety switch, disconnect the device
and check it out.
WARNING - DANGER!
!!
Do not connect two or more devices simultaneously. The start-up
of many devices requires high power. Devices should be connected
in turn according to their power rating. Do not connect any power
consumers within the rst 3 minutes after the generator start.
11.1. GASOLINE POWERED GENERATOR ENGINE START
1. Move the fuel valve to the “OPEN” position.
2. Set the air choke to the closed position.
3. To start the generator manually, grasp the starter handle and slowly pull
it until resistance is felt. Pull the starter cord to the full length with a sharp
movement.
4. Set the air choke to the “OPEN” position.
Fuel valveFig. 7
Closed
Open
Air choke
closed
Hand starter
OPEN
openCLOSE
12
Page 14
12. ENGINE STOP
PLEASE NOTE!
!!
Disconnect all devices before stopping the generator! Do not stop the
generator if it has any devices connected to it. This may disable the
generator!
12.1. GASOLINE POWERED GENERATOR STOP:
1. Disconnect all power consumers from the generator, set the safety switch to
the OFF position.
2. In case of manual start, set the engine switch to OFF.
3. In case of electric start, set the key to OFF.
4. Move the fuel valve to the “CLOSE” position.
5. Allow the generator to operate at idle for 3 minutes so that the alternator
cools down.
13. MAINTENANCE
Maintenance work listed in section "Maintenance" should be performed on a
regular basis. If you cannot perform maintenance work on your own, please
contact the authorized service center to request the required maintenance work.
PLEASE NOTE!
!!
The manufacturer shall not be liable for any damage caused by failure
to perform maintenance work.
Such damage also includes:
- Damage resulting from the use of non-original spare parts;
- Corrosive damage and other eects of improper storage of equipment;
- Damage caused by maintenance work performed by unskilled technicians.
The current list of service centers can be found on the exclusive importer's
website: www.ks-power.com.ua. Main service center: Kyiv, 47 Elektrotekhnichna
Str., Tel.: (096) 967 43 31, (050) 147 35 39, (093) 100 06 47.
Observe the instructions in this manual!
The generator must be maintained, operated and stored in accordance with the
instructions in this manual. The manufacturer shall not be liable for damage and
loss caused by failure to comply with safety and maintenance regulations.
This primarily applies to:
- The use of lubricants, fuels and motor oils not authorized by the manufacturer;
- Technical changes to the product;
- The misuse of equipment;
- Indirect losses caused by operation of the product with defective parts.
13
Page 15
14. RECOMMENDED MAINTENANCE
SCHEDULE
Node
or 20 hours
First month
Motor
oil
Air
lter
Sparking
plug
Fuel
tank
Fuel
lter
Service type
Checking
level
Changing
VV
Cleaning
VV
Changing
Cleaning
VV
Changing
Checking
level
Cleaning
Cleaning
Before starting
Each month or after
20 working hours
Each 3 months or
Each 6 months or
after 50 working hrs
after 100 working hrs
V
V
V
V
V
300 working hrs
Each year or after
V
15. SPARK PLUG MAINTENANCE
A spark plug is an important element that ensures proper engine operation. It
must be intact, properly gapped and free of deposits.
Inspecting the spark plug:
1. Remove the spark plug cap.
2. Unscrew the spark plug with the appropriate wrench.
3. Visually inspect the spark plug. If the spark plug is damaged, it must be
replaced. It is recommended to use the F7TC spark plug.
4. Measure the gap. It should be in the range of 0.7 – 0.8 mm.
5. Before re-using the spark plug, it must be cleaned from deposits with a metal
brush. After that, set the correct gap.
6. Screw in the spark plug back with the dedicated spark plug wrench.
7. Replace the spark plug cap.
Spark plug0,60 - 0,80 мм
Fig. 8Fig. 9
Electrodе
14
Page 16
16. RECOMMENDED OILS
Motor oil signicantly aects the engine performance and is the main factor that
determines its service life. Use oil intended for four-stroke automobile engines,
as it contains detergent additives that meet or exceed the SE standards according
to the APE classication (or equivalent). Generally, it is recommended to use oil
with a viscosity of SAE 10W-30. Motor oils with a dierent grade shown in the
table can be used only if the average air temperature in your area does not fall
outside the specied temperature range. SAE oil viscosity or oil service category
is indicated on the APE tank label.
5W-30, 10W-30
-20-10010203040
REPLACING OR ADDING MOTOR OIL
If the oil level drops, fresh oil must be added to ensure proper operation of the
generator. Check the oil level according to the maintenance schedule.
To drain oil, proceed as follows:
1. Wear protective gloves to avoid getting oil on your skin.
2. Place an oil drain tray under the engine.
3. Unscrew the drain cap located on the engine under the dipstick cap with a
10 mm wrench (for generators up to 3.0 kW) or 12 mm (for generators above
3.0 kW).
4. Wait for the oil to drain.
5. Replace the drain cap and tighten securely.
6. It is better to drain oil while the engine is still hot after operation to ensure
quick and complete oil draining.
To add oil, proceed as follows:
1. Wear protective gloves to avoid getting oil on your skin.
2. Make sure the generator is mounted on a at, level surface.
3. Unscrew the dipstick cap on the engine.
4. Use a funnel to ll the crankcase with high-grade oil. The funnel is not
included. After lling, the oil level should be close to the top of the oil ller.
0
C
Fig. 10
Dipstick cap
Fill to here
Drain cap
15
Page 17
WARNING - DANGER!
!!
Oil pollutes soil and groundwater. Avoid oil leaking out of the
crankcase. Dump used oil into the sealed container.
Hand over used oil to waste oil collection point.
17.
AIR FILTER MAINTENANCE
The air lter should be checked for contamination from time to time. Regular
maintenance of the air lter is necessary to maintain sucient air ow in the
carburetor.
Cleaning the lter
1. Open the clips on the top cover of the air lter.
2. Remove the sponge lter element.
3. Remove all dirt inside the empty air lter housing.
4. Clean the lter element thoroughly in warm soapy water.
5. Dry the sponge lter.
6. Soak a dry lter element in engine oil, and then squeeze out excess oil.
PLEASE NOTE!
!!
Replace the air lter every 50 operating hours of the generator
Cover spring
(every 10 hours in dirty conditions).
Air lter cover
Fig. 11
Cover spring
2143
CleanSqueeze outSoakSqueeze out
Filter
16
Page 18
18. GENERATOR STORAGE
The generator must be stored in a dry, well-ventilated area that is free from dust.
Keep away from children and animals. It is recommended to store and use the
generator at a temperature of -20 to +40 °C. Do not expose the generator to
direct sunlight and precipitation.
PLEASE NOTE!
!!
Note! The generator must always be ready for use. Any malfunctions
in the generator must be repaired before placing the generator in
storage.
PLEASE NOTE!
!!
Before long-term storage of the generator when the engine is
running, close the fuel valve of the fuel tank and allow the engine to
work gasoline out of the carburetor. Wait until the engine stops.
In case of lengthy generator downtime, observe the following
conditions:
- External parts of the generator and engine, especially cooling ns, must be
thoroughly cleaned.
- Unscrew the carburetor oat chamber screw, empty the chamber.
- Remove the spark plug.
- Unscrew the oil drain screw and drain the oil.
- Add a teaspoon of engine oil (5 – 10 ml) to the cylinder. After that, pull the
starter cord several times so that the oil spreads along the cylinder walls.
- Replace (screw in) the spark plug.
- Pull the starter handle until resistance is felt so that the piston is at the top of
its stroke. As a result, the inlet and outlet valves of the generator will be closed
and no internal corrosion of the engine will occur if the device is stored in that
position.
- Release the starter handle smoothly.
- Remove the battery terminals. Grease the battery and connection terminals
with anti-oxidation grease.
19. GENERATOR TRANSPORTATION
For convenient transportation of the generator, use the original packaging of
the generator. Secure the generator packaging to prevent the generator from
tipping over during transportation. Before transporting the generator, drain the
fuel and disconnect the battery terminals.
To lift or handle the generator on site, grasp it by the frame. Be careful when
handling the heavy generator (40 to 90 kg). It is recommended that the
generator be carried by at least two people. Move carefully, do not put your feet
under the generator frame.
20. GENERATOR DISPOSAL
To prevent damage to the environment, do not dispose of the generator in normal
household waste. Dispose of the generator in the safest way by handing it over to
dedicated waste collection points.
17
Page 19
21. TROUBLESHOOTING
FaultProbable causeRemedy
The engine start key (button)
is set to the OFF position
The fuel valve is set to the “CLOSE”
position
Air choke is openClose the air choke lever
Engine will not
start
Reduced engine
power / troubled
engine start
Engine overheating
Engine starts, but
no output voltage
Generator works,
but does not support
connected electrical
devices
Fuel tank is emptyFill in the fuel tank
Fuel tanks contains dirty or
used fuel
Spark plug smoked or
damaged; wrong distance
between electrodes
Fuel tank is dirtyClean the fuel tank
Air lter is dirtyClean the air lter
Water in fuel tank and/
or carburetor; clogged
carburetor
Wrong distance between
spark plug electrodes
Cooling ns are contaminatedClean the cooling ns
Air lter is dirtyClean the air lter
Circuit breaker trippedSet the circuit breaker to ON
Connection cables of poor
quality
Faulty connected device
Device overloadTry to connect less equipment
Short circuit of one of the
connected devices
Air lter is dirtyClean the air lter
Insucient engine speedContact the service center
Set the engine start key
(button) to the ON position
Move the fuel valve to the
“OPEN” position
Replace fuel in the fuel tank
Clean the spark plug or
replace it with a new one; set
the correct distance between
the electrodes
Empty the fuel tank, fuel line
and carburetor
Set the correct distance
between the electrodes.
Check cables for normal
operation; replace, if
extension cable is used
Try connecting another
device
Try disconnecting the faulty
device.
18
Page 20
22. AVERAGE POWER CONSUMPTION OF
DEVICES
DevicePower (kW)
Iron500-1100
Hair dryer450-1200
Coee machine800-1500
Electric cooker800-1800
Toaster600-1500
Heater1000-2000
Vacuum cleaner400-1000
Radio50-250
Grill1200-2300
Oven1000-2000
Fridge100-150
TV set100-400
Perforator600-1400
Drill400-800
Freezer100-400
Grinder300-1100
Circular saw750-1600
Crank gear650-2200
Jigsaw250-700
Planer400-1000
Compressor750-3000
Water pump750-3900
Bench saw1800-4000
Electric mower750-3000
Electric motors550-5000
Fans750-1700
High pressure unit2000-4000
Air conditioner1000-5000
19
Page 21
WARRANTY TERMS:
Warranty repair is carried out only if you have a fully completed warranty card, the Buyer's signature
of acceptance of the warranty terms, as well as a document supporting the purchase (cash receipt, sales
slip or invoice). In the absence thereof, as well as in the event of errors or corrections not authenticated
by the seller's seal or illegible inscriptions in the warranty card or tear-o coupon, no warranty repair
is carried out, no objections to quality are accepted and the warranty card is withdrawn by the service
center as invalid.
The product covered by a one-year warranty from the date of purchase, which is conrmed by record
and seal of the seller in the warranty card.
Within the warranty period, the product owner is entitled to free repair of the defective product due
to defect in workmanship or materials used in production. Warranty service can be carried out only in
authorized service centers specied in the warranty card or on the ocial importer's website: www.kspower.com.ua.
The product is accepted for repair clean and full.
NO WARRANTY SHALL APPLY IN THE FOLLOWING CASES:
• If the user has failed to comply with the
instructions in this manual.
• If the product features damaged or missing
identication stickers or labels, serial numbers, etc.
• If product malfunction was due to improper
transportation, storage and maintenance.
• In case of mechanical damages (cracks, chips,
impact and fall marks, deformation of housing,
power cord, plug or any other components),
including those resulting from the freezing of
water (ice formation), provided there are foreign
objects inside the unit.
• If the product has been improperly installed
and connected to the mains supply or misused.
• If the claimed malfunction cannot be
diagnosed or demonstrated.
• If proper operation of the product can be
restored following cleaning from dust and dirt,
appropriate adjustment, maintenance, oil change,
etc.
• If the product is used for business related
purposes.
• If faults are detected, which have been caused
by product overload. Signs of overload are molten
or discolored parts as a result of high temperatures,
damaged cylinder or piston surfaces, degraded
piston rings or connecting rod bushes.
• The warranty does not cover the failure of
the product automatic voltage regulator due to
careless handling or mishandling.
• If faults are detected, which have been caused
Under no circumstances shall the manufacturer and the importer be liable for any costs associated
with the installation and dismantling of the product.
The fact of purchase and this warranty do not in any circumstances give you the right to compensation
for damages arising from the use or inability to use the purchased product.
by instability of the user's power grid.
• If there are faults caused by contamination
or fouling such as contamination of the fuel, oil or
cooling system.
• If electrical cables or plugs show signs of
mechanical or thermal damage.
• In the event of foreign liquids and objects,
metal chips, etc. inside the product.
• If the malfunction is caused by the use of nonoriginal spare parts and materials, oils, etc.
• If there are two or more faulty units that are
not interconnected.
• If the damage was caused by natural
factors such as dirt, dust, humidity, high or low
temperature, natural disasters.
• To quick-wear parts and components (spark
plugs, nozzles, pulleys, lter and safety elements,
batteries, removable devices, belts, rubber seals,
clutch springs, axles, manual starters, oils, gear).
• To preventive maintenance (cleaning,
greasing, washing), installation and adjustment.
• If the product was tampered with,
independently repaired or modied.
• In case of malfunctions resulting from normal
wear and tear as a result of long-term use (end of
life).
• If product operation was not stopped and
continued after detecting a malfunction.
• Batteries supplied with equipment are
covered by a warranty of three months.
Page 22
Page 23
CONTACTS
Germany
ks-power.de
info@dimaxgroup.de
Poland
ks-power.pl
info.pl@dimaxgroup.de
Ukraine
ks-power.com.ua
sales@ks-power.com.ua
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.