K&S BASIC KS 2200A, KS 1200C, KS 2200C, KS 2800A, KS 2800C Owner's Manual

Page 1
OWNER’S MANUAL
Gasoline Powered Generator
KS 1200C
KS 2200A
KS 2200C
KS 2800A
Please, read this manual carefully before use!
ENG
Page 2
TABLE OF CONTENTS
1. PREFACE 2
2. SAFETY PRECAUTIONS 2
2.1. Work area 2-3
2.2. Electrical Safety 3
2.3. Personal Safety 3-4
2.4. Safety Precautions for Gasoline Powered Generator Operation 4
3. SAFETY SYMBOLS 5
3.1. Description of safety symbols when operating the generator 5
4. DESCRIPTION OF GENERATOR INSCRIPTIONS 6
5. GENERAL VIEW AND COMPOSITION OF THE GASOLINE POWERED GENERATOR 7
6. GENERATOR SPECIFICATIONS 8-9
7. GENERATOR DELIVERY PACKAGE 10
8. CONTROL PANELS 10
9. COMMISSIONING 11
10. GETTING STARTED 11
10.1. Checking the fuel level 11
10.2. Checking the oil level 11
11. ENGINE START 12
11.1. Gasoline Powered Generator Engine Start 12
12. ENGINE STOP 13
12.1. Gasoline Powered Generator Stop 13
13. MAINTENANCE 13
14. RECOMMENDED MAINTENANCE SCHEDULE 14
15. SPARK PLUG MAINTENANCE 14
16. RECOMMENDED OILS 15
17. AIR FILTER MAINTENANCE 16
18. GENERATOR STORAGE 17
19. GENERATOR TRANSPORTATION 17
20. GENERATOR DISPOSAL 17
21. TROUBLESHOOTING 18
22. AVERAGE POWER RATINGS OF DEVICES 19 WARRANTY PROVISIONS 20
1
Page 3
1. PREFACE
Thank you for your purchase of K&S Basic generator. This owner’s manual contains safety instructions, a description of the use and commissioning of K&S Basic generators and procedures for their maintenance.
The generator manufacturer may make some modications that may not be reected in this manual. The manufacturer reserves the right to make changes in the product design, conguration and construction. The images and drawings in this manual are for reference only and may dier from the actual components and inscriptions on the products.
Contact information that you are free to use in case of any problems can be found at the end of this manual. All information in this manual is correct to the best of our knowledge and belief at the date of its publication. The current list of service centers can be found on the ocial importer's website: www.ks-power.de/en
WARNING - DANGER!
! !
Please read this manual carefully before rst in order to ensure
equipment integrity and avoid possible injuries.
ABBREVIATIONS
KS -K&S Basic electric generator
А- Aluminum alternator winding
С- Copper winding
Please read this manual carefully. Pay particular attention to information that starts with characters/words:
WARNING - DANGER!
! !
Failure to observe the recommendation indicated by this sign may result in serious injury or death to the operator or unauthorized persons.
PLEASE NOTE!
! !
Useful information on the use of the device.
2. SAFETY PRECAUTIONS
2.1. WORK AREA
- The generator must not be used in premises with poor ventilation since exhaust gases contain poisonous carbon monoxide, which is life threatening!
- Do not use the generator in the rain, snow and high humidity. Do not touch the generator with wet hands and expose to direct sunlight for a long time. It
2
Page 4
is recommended to store and use the generator indoors or in well-ventilated premises.
- Always install the generator on a at solid horizontal surface. The generator is equipped with dampers to reduce vibration during operation and avoid damage to the surface where the generator is installed.
- Do not use the generator near ammable gases, liquids or dust. During operation of the generator, its exhaust system becomes very hot. This may cause re or explosion of these materials.
- Keep the work area clean and well lit to avoid injuries.
- Keep unauthorized persons, children and animals away from the running generator.
- Always wear protective shoes and protective gloves when operating the generator.
2.2. ELECTRICAL SAFETY
УВАГА - НЕБЕЗПЕЧНО!
! !
The device generates electricity. Observe safety precautions to
avoid electric shock.
- The wiring diagram for the generator must comply with the installation rules and applicable statutory requirements.
- All wiring connections of the generator must be carried out by a certied electrician in accordance with all electrical codes and regulations.
- Avoid the generator supply from the mains during restoration of the power supply.
- Avoid operating the generator in high-humidity environments. Do not allow moisture to enter the generator, as this increases the risk of electric shock.
- Avoid direct contact with grounded surfaces (pipes, radiators, etc.).
- Be careful when working with the power cord. Replace it immediately in case of damage, as damaged power cord increases the risk of electric shock.
- All connections of the generator to the mains must be carried out by a certied electrician.
- Connect the electric generator to the protective ground before operation using the terminal located on the generator control panel.
- Do not connect/disconnect the generator to/from power consumers while standing in water, on wet or damp soil.
- Do not touch live parts of the generator.
- Only connect the generator to the power consumers that correspond to the electrical specications and power rating of the generator.
- Keep all electrical equipment dry and clean. Replace damaged or worn wiring. Worn, damaged, or rusted terminals must be replaced as well.
2.3. PERSONAL SAFETY
- Do not operate the generator when you are tired or under the inuence of potent drugs, alcohol or medication. During operation, inattention can cause serious injury.
- Avoid inadvertent start-up. Make sure the power switch is set to OFF when turning o the generator.
3
Page 5
WARNING - DANGER!
! !
Failure to comply with these requirements may result in re or explosion of
the generator, as well as re in the building wiring.
- Do not operate the generator in areas with poor ventilation. Exhaust gases contain poisonous carbon monoxide, which is life threatening!
- Make sure there are no foreign objects on the generator when it is turned on. Use the product for its intended purpose only. The generator customer using the device for other than the intended purpose shall be deprived of the right to free warranty repair. Do not sit, stand on the generator and misuse the equipment.
- Always keep proper footing and balance when starting the generator.
- Do not overload the generator, use it for its intended purpose only.
2.4. SAFETY PRECAUTIONS FOR GASOLINE POWERED GENERATOR OPERATION Please note the following:
- Do not start the generator when it is under load.
- The generator must be installed at least 1 m away from explosive and ammable substances and objects since its engine heats up during operation.
- Do not ll the fuel tank when the engine is running.
- Do not smoke while refueling.
- For the generator, A-92 gasoline is recommended. After lling the tank, remove all excess fuel from the surface. Do not use kerosene or other fuel. Otherwise, the engine may be damaged.
- Observe the fuel tank while lling in order to avoid overlling.
- Do not touch the exhaust system after starting the generator and during its operation.
- Avoid operating the generator near water, in the rain or snow if there is a risk of it becoming wet.
- Before starting the generator, learn how to stop the generator in case of an emergency.
WARNING - DANGER!
! !
Fuel pollutes soil and groundwater. Avoid gasoline leaking out
of the fuel tank!
4
Page 6
3.
SAFETY SYMBOLS
3.1. DESCRIPTION OF SAFETY SYMBOLS WHEN OPERATING THE GENERATOR
Fig. 1
1
2
a b c d
1 2
e f g h
a. Be careful when operating the device! Observe the safety instructions in this manual.
b. Operate the generator only in well-ventilated indoor spaces or outdoors. Exhaust gases contain СО2, whose vapors are life threatening.
c. Do not operate or store the device in high­humidity environments.
d. Do not smoke while operating the generator! e. The device generates electricity. Observe
safety precautions to avoid electric shock. f. Read this owner’s manual carefully before
operating the device. g. Do not touch the generator with wet or dirty
hands. h. Observe re safety regulations, do not operate
the generator near open ame. i. Do not touch! The generator dampener
becomes hot during operation.
Fig. 2
i
5
Page 7
4. DESCRIPTION OF GENERATOR INSCRIPTIONS
APART FROM THE SAFETY SYMBOLS, THE GENERATOR CONTAINS THE FOLLOWING INSCRIPTIONS:
Specications chart. Specications vary from model to model. For more information, see “Generator Specications”.
Noise level information for each model can be found in the specications chart.
Indicates the direction of opening the air choke.
Indicates the position of the fuel valve. The “ON” position means open and the “OFF” position means closed.
Fuel level indicator. The icon on the left indicates that the fuel tank is full, and the icon on the right indicates that the fuel tank is empty.
Crankcase capacity
(varies from model to model)
Recommended oils.
Maintenance information in the language of the country where the generator is sold can be found in the “Maintenance” section.
Note on the required oil level in the crankcase
Ground
6
Page 8
5. GENERAL VIEW AND COMPOSITION OF THE GASOLINE POWERED GENERATOR
8
7
11
9
1
Fig. 3
2
6
5
4
3
12
10
1. Fuel cap
2. Control panel
3. Oil dipstick
4. Oil drain cap
5. Hand starter
6. Fuel valve
! !
The manufacturer reserves the right to make changes in the product
design, conguration and construction. Illustrations in this manual
are for reference only and may dier from actual components and
inscriptions on the products.
7. Air lter
8. Air choke lever
9. Fuel level indicator
10. Damper
11. Alternator
12. Spark plug
PLEASE NOTE!
7
Page 9
6.
GENERATOR SPECIFICATIONS:
Model KS 1200C KS 2200A KS 2200C
Voltage (V) 230 230 230
Maximum power (kW/kVA) 1,0/1,0 2,2/2,2 2,2/2,2
Rated power (kW/kVA) 0,9/0,9 2,0/2,0 2,0/2,0
Frequency (Hz) 50 50 50
Current (A) 4,35 9,57 9,57
Outlets 2*16А 2*16А 2*16А
Fuel tank capacity (L) 6 15 15
Operation time at 50% load 9 13 13
Voltmeter + + +
Noise level LWA (dB) 95 95 95
Output 12 V (A) 12/8,3 12/8,3 12/8,3
Engine model KS-B80 KS-B170 KS-B170
Engine type
Power output (hp) 2,9 5,5 5,5
Crankcase capacity (cm3) 0,37 0,6 0,6
Engine capacity (cm3) 80 163 163
Voltage regulator AVR AVR AVR
Engine start Manual Manual Manual
Power factor (cosφ) 1 1 1
Dimensions (LxWxH), mm 470*365*380 605*445*450 605*445*450
Net weight (kg) 26 40 40
Protection class IP23M IP23M IP23M
Max. altitude above sea level (m) 1000 1000 1000
Relative humidity <30% <30% <30%
Rated voltage tolerance - max. 5%
Gasoline powered
four-stroke
Gasoline powered
four-stroke
Gasoline powered
four-stroke
8
Page 10
Model KS 2800A KS 2800C
Voltage (V) 230 230
Maximum power (kW/kVA) 2,8/2,8 2,8/2,8
Rated power (kW/kVA) 2,5/2,5 2,5/2,5
Frequency (Hz) 50 50
Current (A) 12,7 12,7
Outlets 2*16А 2*16А
Fuel tank capacity (L) 15 15
Operation time at 50% load 12 12
Voltmeter + +
Noise level LWA (dB) 96 96
Output 12 V (A) 12/8,3 12/8,3
Engine model KS-B200 KS-B200
Gasoline
Engine type
Power output (hp) 6,5 6,5
Crankcase capacity (cm3) 0,6 0,6
Engine capacity (cm3) 196 196
Voltage regulator AVR AVR
Engine start Manual Manual
Power factor (cosφ) 1 1
Dimensions (LxWxH), mm 605*445*450 605*445*450
Net weight (kg) 43 43
Protection class IP23M IP23M
Max. altitude above sea level (m) 1000 1000
Relative humidity <30% <30%
Rated voltage tolerance - max. 5%
powered
four-stroke
Gasoline powered
four-stroke
9
Page 11
7. GENERATOR DELIVERY PACKAGE
1. Generator
2. Packaging
3. Owner's manual
4. Spark plug wrench
8. CONTROL PANEL
1 2 3
1. Voltmeter
2. Safety switch
3. Outlets
4. Engine start button (ON/OFF)
5. 12 V/DC sockets
6. Ground connector
Fig. 4
654
USE CARE WHEN THE GENERATOR IS RUNNING:
- You can use the generator if the voltmeter indicates a value of 230 V ±10%
(50 Нz).
- Monitor the voltmeter and stop the generator if the value is too high.
- Avoid using 12 V voltage simultaneously with 230 V.
10
Page 12
9. COMMISSIONING
The generator is supplied without fuel. Before use, be sure to ll the fuel tank. Recommendations for refueling are listed below. The generator is supplied without motor oil. The generator crankcase may contain oil residues after factory tests. Be sure to add oil before use. Recommendations for oils and lling procedure are given below.
To commission the generator, follow the maintenance recommendations for the rst month or twenty hours of operation (whichever comes rst) contained in the “Maintenance” section.
10. GETTING STARTED
10.1. CHECKING THE FUEL LEVEL
1. Wear protective gloves to avoid getting gasoline on your skin.
2. Unscrew the fuel cap and check the fuel level in the tank.
3. Fill the fuel tank to the fuel lter level.
4. Tighten the fuel cap securely.
Fuel cap
Fig. 5
PLEASE NOTE!
! !
For the generator, A-92 gasoline is recommended. Using other fuels may
10.2. CHECKING THE OIL LEVEL
1. Wear protective gloves to avoid getting oil on
your skin.
2. Unscrew the oil dipstick and wipe it out with a
clean cloth.
3. Insert the dipstick without screwing it in.
4. Check the oil level by a mark on the oil dipstick.
5. Add oil if its level is below the mark on the oil
dipstick.
6. Tighten the oil dipstick.
If the generator has not been used for a long time, recharge the
cause damage to the engine.
PLEASE NOTE!
! !
battery with a charger (not included).
11
Fig. 6
Page 13
11. ENGINE START
WARNING - DANGER!
! !
Before starting the engine make sure that the total power of tools or
power consumers corresponds to the rated power of the generator.
Do not exceed the rated power of the generator. Do not connect
any devices before the engine start! In the power supply mode, the
generator should operate no longer than 30 minutes in the range
from rated to maximum power.
Before connecting any devices to the generator, make sure that they are in good condition. If the device that was connected suddenly stopped or failed, immediately disconnect the power using a safety switch, disconnect the device and check it out.
WARNING - DANGER!
! !
Do not connect two or more devices simultaneously. The start-up
of many devices requires high power. Devices should be connected
in turn according to their power rating. Do not connect any power
consumers within the rst 3 minutes after the generator start.
11.1. GASOLINE POWERED GENERATOR ENGINE START
1. Move the fuel valve to the “OPEN” position.
2. Set the air choke to the closed position.
3. To start the generator manually, grasp the starter handle and slowly pull it until resistance is felt. Pull the starter cord to the full length with a sharp movement.
4. Set the air choke to the “OPEN” position.
Fuel valve Fig. 7
Closed
Open
Air choke
closed
Hand starter
OPEN
open CLOSE
12
Page 14
12. ENGINE STOP
PLEASE NOTE!
! !
Disconnect all devices before stopping the generator! Do not stop the
generator if it has any devices connected to it. This may disable the
generator!
12.1. GASOLINE POWERED GENERATOR STOP:
1. Disconnect all power consumers from the generator, set the safety switch to
the OFF position.
2. In case of manual start, set the engine switch to OFF.
3. In case of electric start, set the key to OFF.
4. Move the fuel valve to the “CLOSE” position.
5. Allow the generator to operate at idle for 3 minutes so that the alternator
cools down.
13. MAINTENANCE
Maintenance work listed in section "Maintenance" should be performed on a regular basis. If you cannot perform maintenance work on your own, please contact the authorized service center to request the required maintenance work.
PLEASE NOTE!
! !
The manufacturer shall not be liable for any damage caused by failure to perform maintenance work.
Such damage also includes:
- Damage resulting from the use of non-original spare parts;
- Corrosive damage and other eects of improper storage of equipment;
- Damage caused by maintenance work performed by unskilled technicians.
The current list of service centers can be found on the exclusive importer's website: www.ks-power.com.ua. Main service center: Kyiv, 47 Elektrotekhnichna Str., Tel.: (096) 967 43 31, (050) 147 35 39, (093) 100 06 47.
Observe the instructions in this manual!
The generator must be maintained, operated and stored in accordance with the instructions in this manual. The manufacturer shall not be liable for damage and loss caused by failure to comply with safety and maintenance regulations.
This primarily applies to:
- The use of lubricants, fuels and motor oils not authorized by the manufacturer;
- Technical changes to the product;
- The misuse of equipment;
- Indirect losses caused by operation of the product with defective parts.
13
Page 15
14. RECOMMENDED MAINTENANCE
SCHEDULE
Node
or 20 hours
First month
Motor
oil
Air
lter
Sparking
plug
Fuel
tank
Fuel
lter
Service type
Checking
level
Changing
V V
Cleaning
V V
Changing
Cleaning
V V
Changing
Checking
level
Cleaning
Cleaning
Before starting
Each month or after
20 working hours
Each 3 months or
Each 6 months or
after 50 working hrs
after 100 working hrs
V
V
V
V
V
300 working hrs
Each year or after
V
15. SPARK PLUG MAINTENANCE
A spark plug is an important element that ensures proper engine operation. It must be intact, properly gapped and free of deposits.
Inspecting the spark plug:
1. Remove the spark plug cap.
2. Unscrew the spark plug with the appropriate wrench.
3. Visually inspect the spark plug. If the spark plug is damaged, it must be replaced. It is recommended to use the F7TC spark plug.
4. Measure the gap. It should be in the range of 0.7 – 0.8 mm.
5. Before re-using the spark plug, it must be cleaned from deposits with a metal brush. After that, set the correct gap.
6. Screw in the spark plug back with the dedicated spark plug wrench.
7. Replace the spark plug cap. Spark plug 0,60 - 0,80 мм
Fig. 8 Fig. 9
Electrodе
14
Page 16
16. RECOMMENDED OILS
Motor oil signicantly aects the engine performance and is the main factor that determines its service life. Use oil intended for four-stroke automobile engines, as it contains detergent additives that meet or exceed the SE standards according to the APE classication (or equivalent). Generally, it is recommended to use oil with a viscosity of SAE 10W-30. Motor oils with a dierent grade shown in the table can be used only if the average air temperature in your area does not fall outside the specied temperature range. SAE oil viscosity or oil service category is indicated on the APE tank label.
5W-30, 10W-30
-20 -10 0 10 20 30 40
REPLACING OR ADDING MOTOR OIL
If the oil level drops, fresh oil must be added to ensure proper operation of the generator. Check the oil level according to the maintenance schedule.
To drain oil, proceed as follows:
1. Wear protective gloves to avoid getting oil on your skin.
2. Place an oil drain tray under the engine.
3. Unscrew the drain cap located on the engine under the dipstick cap with a 10 mm wrench (for generators up to 3.0 kW) or 12 mm (for generators above
3.0 kW).
4. Wait for the oil to drain.
5. Replace the drain cap and tighten securely.
6. It is better to drain oil while the engine is still hot after operation to ensure quick and complete oil draining.
To add oil, proceed as follows:
1. Wear protective gloves to avoid getting oil on your skin.
2. Make sure the generator is mounted on a at, level surface.
3. Unscrew the dipstick cap on the engine.
4. Use a funnel to ll the crankcase with high-grade oil. The funnel is not included. After lling, the oil level should be close to the top of the oil ller.
0
C
Fig. 10
Dipstick cap
Fill to here
Drain cap
15
Page 17
WARNING - DANGER!
! !
Oil pollutes soil and groundwater. Avoid oil leaking out of the
crankcase. Dump used oil into the sealed container.
Hand over used oil to waste oil collection point.
17.
AIR FILTER MAINTENANCE
The air lter should be checked for contamination from time to time. Regular maintenance of the air lter is necessary to maintain sucient air ow in the carburetor.
Cleaning the lter
1. Open the clips on the top cover of the air lter.
2. Remove the sponge lter element.
3. Remove all dirt inside the empty air lter housing.
4. Clean the lter element thoroughly in warm soapy water.
5. Dry the sponge lter.
6. Soak a dry lter element in engine oil, and then squeeze out excess oil.
PLEASE NOTE!
! !
Replace the air lter every 50 operating hours of the generator
Cover spring
(every 10 hours in dirty conditions).
Air lter cover
Fig. 11
Cover spring
21 43
Clean Squeeze outSoakSqueeze out
Filter
16
Page 18
18. GENERATOR STORAGE
The generator must be stored in a dry, well-ventilated area that is free from dust. Keep away from children and animals. It is recommended to store and use the generator at a temperature of -20 to +40 °C. Do not expose the generator to direct sunlight and precipitation.
PLEASE NOTE!
! !
Note! The generator must always be ready for use. Any malfunctions
in the generator must be repaired before placing the generator in
storage.
PLEASE NOTE!
! !
Before long-term storage of the generator when the engine is
running, close the fuel valve of the fuel tank and allow the engine to
work gasoline out of the carburetor. Wait until the engine stops.
In case of lengthy generator downtime, observe the following conditions:
- External parts of the generator and engine, especially cooling ns, must be thoroughly cleaned.
- Unscrew the carburetor oat chamber screw, empty the chamber.
- Remove the spark plug.
- Unscrew the oil drain screw and drain the oil.
- Add a teaspoon of engine oil (5 – 10 ml) to the cylinder. After that, pull the starter cord several times so that the oil spreads along the cylinder walls.
- Replace (screw in) the spark plug.
- Pull the starter handle until resistance is felt so that the piston is at the top of its stroke. As a result, the inlet and outlet valves of the generator will be closed and no internal corrosion of the engine will occur if the device is stored in that position.
- Release the starter handle smoothly.
- Remove the battery terminals. Grease the battery and connection terminals with anti-oxidation grease.
19. GENERATOR TRANSPORTATION
For convenient transportation of the generator, use the original packaging of the generator. Secure the generator packaging to prevent the generator from tipping over during transportation. Before transporting the generator, drain the fuel and disconnect the battery terminals.
To lift or handle the generator on site, grasp it by the frame. Be careful when handling the heavy generator (40 to 90 kg). It is recommended that the generator be carried by at least two people. Move carefully, do not put your feet
under the generator frame.
20. GENERATOR DISPOSAL
To prevent damage to the environment, do not dispose of the generator in normal household waste. Dispose of the generator in the safest way by handing it over to dedicated waste collection points.
17
Page 19
21. TROUBLESHOOTING
Fault Probable cause Remedy
The engine start key (button)
is set to the OFF position
The fuel valve is set to the “CLOSE”
position
Air choke is open Close the air choke lever
Engine will not
start
Reduced engine
power / troubled
engine start
Engine overheating
Engine starts, but no output voltage
Generator works,
but does not support
connected electrical
devices
Fuel tank is empty Fill in the fuel tank
Fuel tanks contains dirty or
used fuel
Spark plug smoked or
damaged; wrong distance
between electrodes
Fuel tank is dirty Clean the fuel tank
Air lter is dirty Clean the air lter
Water in fuel tank and/
or carburetor; clogged
carburetor
Wrong distance between
spark plug electrodes
Cooling ns are contaminated Clean the cooling ns
Air lter is dirty Clean the air lter
Circuit breaker tripped Set the circuit breaker to ON
Connection cables of poor
quality
Faulty connected device
Device overload Try to connect less equipment
Short circuit of one of the
connected devices
Air lter is dirty Clean the air lter
Insucient engine speed Contact the service center
Set the engine start key
(button) to the ON position
Move the fuel valve to the
“OPEN” position
Replace fuel in the fuel tank
Clean the spark plug or
replace it with a new one; set
the correct distance between
the electrodes
Empty the fuel tank, fuel line
and carburetor
Set the correct distance between the electrodes.
Check cables for normal
operation; replace, if
extension cable is used
Try connecting another
device
Try disconnecting the faulty
device.
18
Page 20
22. AVERAGE POWER CONSUMPTION OF DEVICES
Device Power (kW)
Iron 500-1100
Hair dryer 450-1200
Coee machine 800-1500
Electric cooker 800-1800
Toaster 600-1500
Heater 1000-2000
Vacuum cleaner 400-1000
Radio 50-250
Grill 1200-2300
Oven 1000-2000
Fridge 100-150
TV set 100-400
Perforator 600-1400
Drill 400-800
Freezer 100-400
Grinder 300-1100
Circular saw 750-1600
Crank gear 650-2200
Jigsaw 250-700
Planer 400-1000
Compressor 750-3000
Water pump 750-3900
Bench saw 1800-4000
Electric mower 750-3000
Electric motors 550-5000
Fans 750-1700
High pressure unit 2000-4000
Air conditioner 1000-5000
19
Page 21
WARRANTY TERMS:
Warranty repair is carried out only if you have a fully completed warranty card, the Buyer's signature of acceptance of the warranty terms, as well as a document supporting the purchase (cash receipt, sales slip or invoice). In the absence thereof, as well as in the event of errors or corrections not authenticated by the seller's seal or illegible inscriptions in the warranty card or tear-o coupon, no warranty repair is carried out, no objections to quality are accepted and the warranty card is withdrawn by the service center as invalid.
The product covered by a one-year warranty from the date of purchase, which is conrmed by record and seal of the seller in the warranty card.
Within the warranty period, the product owner is entitled to free repair of the defective product due to defect in workmanship or materials used in production. Warranty service can be carried out only in authorized service centers specied in the warranty card or on the ocial importer's website: www.ks­power.com.ua.
The product is accepted for repair clean and full.
NO WARRANTY SHALL APPLY IN THE FOLLOWING CASES:
• If the user has failed to comply with the
instructions in this manual.
• If the product features damaged or missing
identication stickers or labels, serial numbers, etc.
• If product malfunction was due to improper
transportation, storage and maintenance.
In case of mechanical damages (cracks, chips, impact and fall marks, deformation of housing, power cord, plug or any other components), including those resulting from the freezing of water (ice formation), provided there are foreign objects inside the unit.
• If the product has been improperly installed and connected to the mains supply or misused.
• If the claimed malfunction cannot be diagnosed or demonstrated.
• If proper operation of the product can be restored following cleaning from dust and dirt, appropriate adjustment, maintenance, oil change, etc.
• If the product is used for business related purposes.
If faults are detected, which have been caused by product overload. Signs of overload are molten or discolored parts as a result of high temperatures, damaged cylinder or piston surfaces, degraded piston rings or connecting rod bushes.
• The warranty does not cover the failure of the product automatic voltage regulator due to careless handling or mishandling.
If faults are detected, which have been caused
Under no circumstances shall the manufacturer and the importer be liable for any costs associated
with the installation and dismantling of the product.
The fact of purchase and this warranty do not in any circumstances give you the right to compensation
for damages arising from the use or inability to use the purchased product.
by instability of the user's power grid.
• If there are faults caused by contamination or fouling such as contamination of the fuel, oil or cooling system.
• If electrical cables or plugs show signs of mechanical or thermal damage.
• In the event of foreign liquids and objects, metal chips, etc. inside the product.
If the malfunction is caused by the use of non­original spare parts and materials, oils, etc.
• If there are two or more faulty units that are not interconnected.
• If the damage was caused by natural factors such as dirt, dust, humidity, high or low temperature, natural disasters.
• To quick-wear parts and components (spark plugs, nozzles, pulleys, lter and safety elements, batteries, removable devices, belts, rubber seals, clutch springs, axles, manual starters, oils, gear).
• To preventive maintenance (cleaning, greasing, washing), installation and adjustment.
• If the product was tampered with, independently repaired or modied.
In case of malfunctions resulting from normal wear and tear as a result of long-term use (end of life).
• If product operation was not stopped and continued after detecting a malfunction.
• Batteries supplied with equipment are covered by a warranty of three months.
Page 22
Page 23
CONTACTS
Germany
ks-power.de
info@dimaxgroup.de
Poland
ks-power.pl
info.pl@dimaxgroup.de
Ukraine
ks-power.com.ua
sales@ks-power.com.ua
Loading...