CapacityQup to 840 m3/h (233 l/s)..................
HeadHup to 480 m.....................
Temperature of fluid handledtup to +50 °C..
Speedn≈ 2900 rpm....................
Supply voltageUup to 10,000 V.............
Design
Single-- or multistage centrifugal pumps in pump shroud or in
ring--section design. Radial or mixed flow hydraulic systems;
reduced impeller diameters also available in some cases. The
stage casings of radial pumps are connected by metal straps,
those of mixed flow pumps by stud bolts. Suction casing fitted
between pump and motor. Suction casing equipped with
strainer to protect the pump from coarse particles in the fluid.
Pumps with check valve or connection branch on option.
Available with threaded or flanged end on option.
Particularlysuitable forverticalinstallationinnarrow deepwells.
Submersible Borehole Pumps
S 100D, UPA 100C, UPA 150S, UPA 200,
UPA 200B, UPA 250C, UPA 300,
UPA 350, BSX -- BSF, UPZ
Pump Designation (Example)
UPA 200 B --8 0 /5 b
Type series
Minimum well diameter (mm)
(for ex.: 200 mm = 8 inches)
Design status
Capacity Q
Number of stages
Reduced impeller diameters
1)
UPA 200 -11 + 14: Q in l/s.
(m3/h)--(4upto10inches)
opt
(l/s) -- (12 inches and above)
Motor Designation (Example)
UMA 250 D 110 /21
Type series
Well diameter (mm)
(for ex. 250 mm = 10 inches)
Design status
Rated power P
Number of poles
Winding insulation
N
(kW)
Certification
Quality management certified to ISO 9001
1)
Available automation products:
• Hyamaster (UPA 150S -- UPA 350)
• hyatronic (UPA 150S -- UPA 350)
• switch gear (S 100D -- UPA 350)
Complete Range
The complete submersible borehole pump range comprises
pump models for flow rates up to Q = 2500 m
heads up to H = 1500 m.
The submersiblemotor range coverssizes for powerratings up
to P = 3500 kW and voltages up to U = 10,000 V for 50 and
60 Hz.
In addition, a special range is available which features
submersible motors with a higher number of poles.
3
/h (695 l/s) and
50 HzSubmersible Borehole Pumps
ContentsPage
The Submersible Borehole Pump Range4.....................................
Operation with Soft Starters5................................................
Operation with Frequency Inverter6...........................................
Flow Velocity “v” Past the Motor108...........................................
2
Submersible Borehole Pumps50 Hz
What can you expect from the
“Submersible Borehole Pumps Booklet”?
The information provided can help you make a
-- quick
-- first rough selection
-- on your own
to find a suitable KSB submersible borehole pump for your
application. Wehave kept the volume of the catalogue down to
what we think is the absolute minimum. For the 4 to 14 inch
range, you will find the following information on the pump
selected:
-- pump series, size and number of stages,
-- motor series, size, power, amperage, and allowable
temperature,
-- starting method, supply voltage and type of installation,
-- material variants and
-- major dimensions and weights.
You may also complete, to the extent possible, the request for
quotation on page 9.
You will then receive as soon as possible a detailed quotation
and, if required, additional literature on KSB submersible
borehole pumps from the nearest KSB sales branch.
Benefits at a Glance
+ Full range of products
+ High-tech equipment
+ Optimum material selection
+ Maximum efficiency
+ Functional reliability
+ Long service life
+ No maintenance
+ “Clean” technology
+ Customer focus
General
Information on fields of application, available models, type of
installation, direction of rotation, coating, connection to power
supply and speed controlis provided inthe detailed sectionsfor
the relevant type series.
Pump Efficiency
The characteristic curves for UPA 200/200B and larger pumps
show pump efficiency for themaximum and optimum (reduced)
impeller diameter (for ex. ”c”). The efficiency of pumps with a
low number of stages or considerably reduced impeller
diameter (for ex. ”d”, “e”) is lower than the value shown; it is
given in the individual characteristic curves specifically
prepared for the quotation.
Dry Running Protection
For use in wells with marked water level fluctuations or
temporary low yield we strongly recommend installing dry
running protection equipment (”Accessories”).
Application Temperatures
The submersibleborehole pumps are, as a standard, suitablefor
use in water with temperatures of up to t = +30
indispensable requirementfor this isa flow velocityof v = 0.2 m/s
past the motor. This requirement is met, for example, when the
pump is installed in a deep well above the well screen / filter, etc.
With certain restrictions, some motor sizes may also be used
in water with temperaturesof up tot = +50
without an adequate cooling flow of water past the motor, i.e.
v = 0 m/s (for example, when the unit is installed in a deep well
below the screen / filter area or in a pump sump, etc.).
The details below provide data of adequate accuracy for the
allowable temperature as a function of the type of installation,
motor size and flow velocity v past the motor:
Vertical installation:
-- DN 100 / DN 150:
t
allow=tmax
-- UMA 150D/200D:
v= 0m/st
v ≥ 0.2 m/st
v ≥ 0.5 m/st
-- UMA 250D:
v = 0 m/sPlease consult manufacturer,......
v ≥ 0.2 m/st
v ≥ 0.5 m/st
1)
Values taken from tables on pages 15, 16 etc., 27, 28 etc..
1)
irrespective of flow past the motor.
≈t
allow
allow
allow
allow
allow
max
=t
max
≈t
max
=t
max
≈t
max
o
C and for operation
1)
-- 5oC,......
1)
,.....
1)
+5oC......
1)
,.....
1)
,+5oC......
o
C. An
Horizontal installation:
The principle is the same as for vertical installation.
Exception: Pumps with UMA 250D motors.
These units must always be equipped with a flow inducersleeve. The flow inducer sleeve is not required, if the given
pump is equipped with a motor having a 10 % higher power
rating.
For all pump sets:
For a flow velocity of v ≥ 0.5 m/s and horizontalinstallation, check
back with the manufacturer.
3
The Submersible Borehole Pump Range
" UPV 200
UPV 150S "
(6 inch)
" UPA 100C
(4 inch)
p. 23 -- 32
on request
50 HzSubmersible Borehole Pumps
" UPZ
BSX - BSF
(≥ 16 inch)
p. 83 -- 90
on request
(8 inch)
on request
" UPA 300, 350
(12/14 inch)
p. 69 -- 82
" S 100D
(4 inch)
p. 11 -- 22
UPA 200 "
(8/10 inch)
p. 49 -- 57
" UPA 150S
(6 inch)
p. 33 -- 48
" UPA 250C
(8/10 inch)
p. 62 -- 68
" UPA 200B
(8/10 inch)
p. 58 -- 61
4
Submersible Borehole Pumps50 Hz
Operation of KSB submersible motor pumps with soft starters
Soft starterelectronically reduce the incoming line voltage and,
hence, the initial starting torque and starting current of electric
motors. During run--up they gently ramp up the applied voltage
to the motor.
In the case of submersible motors, the extremely slim design
and consequential small moments of inertia result in special
characteristics,whichdifferstronglyfromnormal
asynchronous motors.
12.3 Soft starter settings
Effects on submersible borehole pumps
-- Starting current ⇒ approx. 40% to 65% of IArequired for
direct-starting.
-- Run-up time t
with approx. 0.2s to 0.5s for direct. starting.
-- Starting torque M
torque.
-- No current or torque peaks (I
switching arrangement.
-- Hydraulic pressure surges (waterhammer) upon starting
and stopping of the pump can be reduced, but not fully
eliminated. Therefore, soft starters are not suitable for
solving water hammer problems.
This would require the use of hydraulic control equipment
or a frequency inverter. To prevent effects due to power
failure, additional measures are required.
increased to approx. 1s to 3s compared
H
roughly 1/4 of the direct-starting
A
), as in star-delta
A,MA
Note
Conspicuous noiseor vibrations duringrun-up could well be an
indication of incorrect settings on the soft starter. This might be
due to exceeded ramp--up periods, incorrect operating mode
(setting), activated special functions, etc.
Parameter / FunctionSettingComments
Minimum starting voltage40% of the motors’ rated voltage
Ramp time / acceleration
(run--up) time
Current limitationIA/INpreset to approx. 3.5Should only be altered with allowance for
Deceleration (run--down) time /
stop ramp
Special functions, e.g.:
-- special “pump function”
-- kick--start / boost function
-- speed adjustment
-- Current contoller
-- cos ϕ- / economy function
-- delayed starting
During operation the soft starter must be bridged (bypass). This helps to avoid losses at the machine and motor to secure proper
permanent operation.
120
< 4sRamp time is nor identical with the motor
Deceleration time tA< 4sBetter without a ramp.
OFFDo not use, as they tend to be troublesome,
Run--up
Operation
actual run--up time
< 4s
t
H
particulary in submersible borehole applications.
Run--down
100
80
60
40
Voltage [%]
20
0
4s
Time [s]
4s
5
Pump Operation with Frequency Inverter
3
0
203
0
50 HzSubmersible Borehole Pumps
In principle, the motors of submersible borehole pumps can
also be run on a frequency inverter. As submersible motors
differ from conventional standardized motors in terms of
bearings, moment of inertia, insulation, temperature increase,
loss distributionand heat distribution, the following parameters
must be observed:
-- Maximum allowable acceleration time (start ramp)
-- Maximum allowable deceleration time (stop ramp)
-- Minimum frequency
-- Maximum operating frequency
-- Maximum permissible voltage increase velocity and peak
voltages
-- Control principle of frequency inverter
Maximum Allowable Acceleration Time (Start
Ramp) and Deceleration Time (Stop Ramp)
The plain bearings of the submersible motor do not tolerate
operation below the minimum frequency f
mixed lubrication range).
For this reason, the acceleration period from standstill to
minimum frequency f
should not exceed 2s. The same
min
applies to the deceleration period.
(operation in
min
Minimum Frequency
Minimum frequency f
Motor size
DN 100
Vertical
installation
30
DN 150
UMA 150D
2030
UMA 200D
UMA 250D
UMA 300D /2
UMA 300D /43035
(Hz)
min
Horizontal
installation
30
-- --
Maximum Operating Frequency
Frequency inverter operation above the nominal frequency
(50Hz /60Hz) ofthe pumpunit must beavoided soas toprevent
motor overload.
Maximum Permissible Voltage Increase Velocity
and Peak Voltages
Excessive voltage increase velocities and excessive peak
voltages will reduce the service life of the winding insulation.
For this reason, the following limits must be adhered to:
-- Maximum voltage increase velocity:
du/dt ≤ 500 V/µs
-- Maximum peak voltages to earth:
Low-voltage motors ≤ 1 kV:J1 insulation ≤ 600 V
J2 insulation ≤ 800 V
For motor sizes DN 100 and DN 150, the limit values for J1
insulation apply.
Note: Compliance with these limits can usually be assured by
means of a sine filter or
du
/dtfilter.
Control Principle of Frequency Inverter
The control principleof the frequency inverter must correspond
to linear U/f curve control. If other control principles are
employed, such as field-oriented inverters, inverters with DTC
or NOF,the manufacturerof the frequency invertermust ensure
that thespecial requirementsof submersiblemotors (very small
moment of inertia, electrical data) are taken into account.
Note: For details refer to ”Design and Selection Information for
Running Submersible Borehole Pumps on Frequency
Inverters”, Ref. No. 3400.0610--10.
6
Typical Installation Positions
a)Vertical Installation
(deep well, pump sump, etc.)
CAUTION:
The construction of the well head must meet the relevant
regulations ofthe competent authorities! The unit must never
be installed with its suction strainer exactly at the level of the
well screen / filter!
Before installingthe unitin narrowdeep wells werecommend to
check narrow boreholes for dimensional accuracy over their
entire length, e.g. by inserting a pipe of the length and biggest
outside diameter of the pump unit. Sharp bends or bottlenecks
can make installation difficult or even impossible.
The unit is supported on the well head by supporting clamps
(low-weight unitsand lowsubmergence) ora supportingflange.
The construction of the well head must meet the relevant
regulations of the competent authority.
5
8
Submersible Borehole Pumps50 Hz
Cooling / Suction shroud
Fig. 2Installation in a pump sump
3400:50
4
6
H
h
H
t
3
B
B
7
H
e
X
2
T
1
1 Submersible borehole pump
F
T
B
2 Riser pipe
3 Cable tie
9
4 Supporting flange / Well head
5 Pressure gauge
6 Shut-off valve
7 Power supply cable
8 Control box
9 Well screen / filter
D
3410:70/4
D=Inside well diameter
T
=Well depth
B
=Well screen / filter depth
T
F
H
=Installation depth
e
H
=Static water level
h
=Dynamic water level (Pumping water level)
H
t
Fig. 1Vertical installation (in deep well, pump sump, etc.)
The suspension arrangement of the pump unit must be
designed and dimensionedso that allstatic anddynamic forces
can be absorbed and that theriser pipe cannot slip downwards.
The supporting clamps or flanges must be fastened at the well
head so that they cannot shift of lift off the well head.
The unit mustnever be installed with its suction strainer exactly
at the level of the well screen / filter! Excessive flow in the area
of the well screen / filter entails the risk of large amounts of
entrained sand clogging the well screen / filter and causing
excessive wear in the pump.
Pump units installed in a pump sump must generally be
equipped with a cooling or suction shroud (fig. 2).
b)Horizontal Installation
(in reservoirs, mine shafts, etc.)
CAUTION:
The instructions given in ”a) Vertical installation” shall also apply
by analogy to horizontal installation, when the pump unit is fitted
on mounts (pedestals / supporting frame) supplied by us. If the
pump and motor are supplied ready mounted on a supporting
frame, on-site alignment of pump and motor will not be
necessary. If this is not the case, the relevant installation /
assembly drawing must be ordered, giving the following details:
-- installation height (floor clearance),
-- spacing of supports,
-- submergence X
The ground / foundation must be level and of sufficient
load-bearing capacity to accept the weight of the unit with
supports.
Air intake from an inlet arranged above the water level is not
permitted.
X
3410:71/2
Fig. 3Horizontal installation (in tanks, mine shafts etc.)
(only if pump unit does not have its own check valve)
6 Dismantling joint
7 Shut-off valve
8 Intake
7
50 HzSubmersible Borehole Pumps
Submersible Borehole Pump Selection for Deep Wells
Pump Selection
The following data are required for a first rough selection of a
submersible borehole pump:
-- Capacity Q in m
-- Pressure at well head H
-- Well diameter in inches or mm
-- Temperature of fluid handled t
-- Pump head HPin m
While Q, H
head H
A
to be developed by the pump needs to be calculated.
P
There are two typical applications to be considered (see the
drawing on the right):
1.Pumping into an open overhead tank
HP=HA+Ht+Hv+HS[m]
where ...
HA= Required pressure at well head
H
= Lowest water level (dynamic water level)
t
Hv= Head losses in the checkvalve (see characteristic
H
= Head losses in riser pipe up to well head
S
H
= Installation depth
e
3
/h (l/s)
in m
A
in °C
A
, D and tAare usually specified bythe customer,the
curves for different stage numbers for UPA 150S
and above).
(see page 10).
2.Pumping into a closed tank
Hp=HA+Ht+Hv+HS+pü[m]
where ...
pü= Gauge pressure (also air cushion) in a tank
Example
Given ...
QA= 120 m3/h,
=95m,
H
A
tA=+15°C,
50 Hz, 400 V and d.o.l. starting,
well diameter D = 250 mm (10 inches).
...
Found
1. step:
pump type UPA 200B/250C
(for Q
2. step:
pump size UPA 200B - 130
(for QAtaken from selection chart on page 50)
3. step:
pump set UPA 200B-130/6b + UMA 200D 45/21
(for Hp=HA+Ht+HV+HS= 95 + 4 + 0.75 + 0.26 = 100 m
with H
numbers on page 61).
Pump efficiency: ηP= 80.5 % (without check valve)
taken from selection chart on page 4)
A
taken from characteristic curves for different stage
V
3300:54/3
Figure:
Deep well with submersible borehole pump and overhead tank
or closedtank at apressure above atmospheric pressureof p
ü.
8
50 HzSubmersible Borehole Pumps
Request for Quotation
We should like to test the efficiency and quality of your computer-aided quotation process.
Please let us have a quotation based on the following data. (Fill in the required data and
/ or underline the relevant information, as far as available.)
1. Water quality
Discharge head required at theend of the
piping:
Temperature°C.....................
8
Sand contentg/m
..................
H =m (bar).....................
3
Cut-out pressure in the pressure vessel:
Please attach water analysis, if available.
p
=bar............
Ü
2. Type of system
7
6
Well / Mine shaft / Tank
Free discharge above ground
Discharge into an overhead tank
Discharge into a pressure vessel
c)Piping outside well head housing:
Overall lengthm....................
Nominal diametermm...............
Number of bends, valves and fittings:
pcs................................
3. Deep well
Well depth(distance from ground level to
5
well base):
T
=m............................
B
Inside diameter at submersible pump
installation depth:
D =mm (inches)..................
4
Well screen / filter:
-- Installation depth T
=m...........
F
Inside diameter reduced by incrustation
to: D =mm........................
6. Installation depth
Ground level to check valve / to
connection branch:
He =m............
Caution: Do not install the submersible
borehole pump at the level of the well
screen / filter!
F
1 Well screen / filter
2 Well casing
3 Submersible borehole pump
4 Riser
5 Well head housing
6 Well head
7 Power supply cable
8 Overhead tank
3
2
1
3300:54/3
-- Length L
=m...................
F
4. Capacity
Q=m3/h (l/s)....................
5. Total head
(including all friction losses)
H=m............................
If H is not known, please provide the
following data:
a)
Water level in well, measured from
ground level:
-- Static water level: H
-- Dynamic water level: H
(at capacity Q =m
b)
Head above ground:
Geodetic altitude up to the highest point
of the pipeline or up to the highest water
level in the overhead tank:
H
=m...........................
d
=m..........
h
=m........
t
3
/h)..............
7. Power supply
Single- / three-phase alternating current.
Mains voltage at well:
U=V.............................
Frequency f =Hz..................
If voltage drops cannot be precluded:
Minimum voltage ...
U
=V...........
min
8. Control box
Manual start-up / remote control / automatic start-up by way of float switch,
pressure switch or dry running protection
equipment.
Other types of switchgear: ...........
...................................
9. Starting method
D.o.l. (without / with autotransformer or
soft starter) or star-delta starting.
9
Head losses in the piping
H
V
m/100 m
50 HzSubmersible Borehole Pumps
H
V
ft/100 ft
The frictionlosses givenin theabove chart roughlyapply tonew
cast iron pipes.For newrolled steelor plasticpipes, multiply the
values by approx. 0.8. For old, slightly rusty cast iron pipes,
multiply by approx. 1.25. In pipes with incrustations, friction
losses may rise to 1.7 times the value given in the chart for the
10
3300:103/3-2
diameter reduced by incrustations. For pipes subject to considerable incrustation, the friction losses can only be determined experimentally.
Example: Q = 140 m
H
V
3
/h, new DN 150 cast iron pipe.
= 3.25 m per 100 m of pipe, v = 2.2 m/sec.
50 HzS 100D
Applications
-- Domestic and general water supply
-- Irrigation and spray irrigation
-- Lowering groundwater levels
-- Fountains
-- Pressure boosting
-- Air-conditioning systems
-- Fire protection
-- Cooling water cycles
Operating Data
CaoacityQ up to 16 m3/h
HeadH up to 300 m
Temperature of fluid handled
tupto+30°C in continuous operation
PowerPn up to 5.5 kW
Pump Type / Design
Pump:
Stainless steel and plastic multistage centrifugal pump.
-- Additional bearing depending on the number of stages
-- Pump sizes D1 and D2 with anti-blockage feature. This consists of a hexagonal polyurethane disc mounted to the back
of the diffuser. A PE-HD ring fitted to the impeller front side
sits closeto thedisc. The impeller hub is protected by apolyurethane ring.This design improves the starting torque of lowcapacity pumps and has the effect that solid particles such as
sand are propelled outside instead of clogging the pump.
Motor:
Submersible canned motor (Franklin), NEMA standard, 50 Hz
-- For single-phase alternating current (type PSC) or threephase current
-- With short cable
-- Connection to power supply mains by means of cable connector (accessories)
-- D.o.l. starting, start-up frequency up to 20/h
-- Type of enclosure IP 68
-- Thermal class B
Submersible Borehole Pumps
for Well Diameters
of 100 mm (4 inch)
Designation
S 100 D -- 4 / 6
Type series
Well diameter (mm)
Status
Capacity (m
Number of stages
3
/h)
Recommended Accessories
UPA Control: Control box for motor and dry running protection
by immersion electrodes.
Automatic control unit: in conjunction with the Controlmatic
E or Cervomatic EDP control and monitoring units, which protect thepump againstdry running, ifthe waterlevel falls,S 100D
can be used for automatic water supply
Certification
Quality management certified to ISO 9001
Available automation products:
• Automatic control unit
Product Features
-- Pumps sizes D1 and D2 with anti-blockage feature
-- Rust-proof
-- Suitable for installation in narrow deep wells
-- High efficiency
-- Hermetically sealed motor
-- Motor designed for maximum pump output
-- Low noise level
-- For vertical, angled or horizontal installation
-- Check valve with anti-blockage valve disc
11
50 HzS 100D
Selection Chart (Ranges on Offer)n ≈ 2900 rpm
Note:
Up to a motor rating of PN= 2.2 kW, all pump sizes can be supplied with either single-phase a.c. or three-phase current motors.
Plain bearings, lubricated by the fluid pumped or by the motor
fill liquid. Depending on the number of stages, an additional intermediate bearing is provided in the pump.
The axial thrust is balanced by a thrust bearing in the motor.
The hydraulic thrust is balanced by the pump’s counter thrust
bearing.
Direction of Rotation of the Pump
Clockwise rotation (viewed at the drive shaft end).
Pump End (Discharge Nozzle)
S 100D - 1, 2, 4 + 7: Internal thread G 1’’1/4(DN 32).
S 100D - 12:Internal thread G 2’’ (DN 50).
Drive
Typecanned motor in squirrel-....................
cage design, 2 poles
ConnectionNEMA standard..............
Type of enclosureIP 68........
Frequency50 Hz..............
Type of currentsingle-phase a.c. (1
or three-phase (3
Rated voltage U220 ... 230 V (1~) and..........
380 ... 400 V (3~)
Rated power P
Voltage fluctuationup to ± 5 % acc. to VDE........
Frequency of startsup to 20/h.......
Min. delay before restarting3 min.
A starter for single-phase a.c. motors in PSC design (with
integrated run capacitor and motorprotection) is included inthe
scope of supply.
N
up to 2.2 kW for 1~ and............
up to 5.5 kW for 3~
µ)...........
µ)
Connection to Power Supply
All DN 100 motors are factory-equipped as follows:
1 x 1.5 mflatcable, quality 4x 1.5 mm2(3 phases + 1 earthconductor).
Exception: DN 100 motors with a rating of 5.5 kW, 3~, are
equipped as follows: 2.5 m cable, quality 4 x 1.5 mm
Connection of extensioncable (any length)by meansof a cable
connector
Connected at the factory by means of a standard cable con-
nector (non-separable, shrink tube)
Ident. No.40 980 708
For cable quality 4 x 1.5 mm
Ident. No.39 020 536
For cable quality 4 x 4 mm
Connected at the factory with Franklin cable connector
(separable, sealing compound)
Ident. No.90 049 385
For cable quality 4 x 1.5 mm
2
or 4 x 2.5 mm
2
2
up to 4 x 2.5 mm
2
.
2
2
Installation
Vertical and, depending on the number of stages, also angled
and horizontal installation.
Starting Mode
Only direct on line.
Temperatures
The S 100D submersible borehole pump is designed for use in
water with temperatures of up to t = + 30
o
C.
Variants Available on Request
-- Higher fluid temperatures
-- Higher voltages up to 500 V
-- Other frequencies
13
Design Features
50 HzS 100D
Easy to commission and service
D Vent valve for operation with automatic
control units such as Controlmatic E or
Cervomatic EDP
D Easy to install thanks to plug--type
connection of power cable of Franklin
submersible motor
D The cable guard is easy to fit and remove.
High operating reliability and
long service life
D Maintenance--free and wear--protected
pump bearings
D Special guide feature prevents jamming
or tilting of the check valve
D Cable guard protects cables from damage.
Highly corrosion--resistant
D Suction casing, check valve
housing and outer casing made of
stainless steel
D Hydraulic system made of glass
fibre reinforced Noryl
14
S 100D -- 1 ...
(motor)
ith
for well diameters of 100 mm (4 inch)
Pumps with submersible motors for ...
-- Temperature of fluid handledup to + 30oC............
-- Current / Operating voltage1~/230 V..................
or 3~/400 V.......................................
Maximal capacitiesQup to 15 m3/h
Maximal HeadHup to 400 m
Maximum fluid temperaturet30 °C
Motor ratingsP
Maximum permissible
amount of suspended sand:50 g/m
up to 7.5 kW
N
3
Pump Type / Design
Multistage centrifugal pump with components made of
stainless steel and additional bearing for eachstage. The stage
casings are connected by means of tie bolts on radial pumps,
and by means of studs on mixed--flow pumps.
Submersible canned motor: Franklin Electric pre-filled
motors, corrosion free, NEMA shaft end, 50 Hz
-- Single-phase and three-phase motor type Super Stainless
-- With separate lead
-- Direct starting, max starts per hour: 20
-- Type of enclosure: IP 68
-- Insulation: Class B
Submersible Borehole Pumps
for Well Diameters of
100 mm (4 inches)
Pump Designation
Type series
Minimum well diameter (mm)
Design status
Capacity Q
Number of stages
opt
(m3/h)
Certification
Quality management certified to ISO 9001
UPA 100 C –4 6
Product Features
-- Very sturdy design
-- All components made of stainless steel
-- Suitable for installation in narrow deep wells
-- High efficiency
-- Totally enclosed motor
-- Motor designed for maximum pump output
-- Low noise level
-- For vertical or horizontal installation
-- Check valve protected against blocking
-- Pre-filled motor; no risk of contamination of the
pumped water
23
UPA 100C
Selection Chart (Ranges on offer)n ≈ 2900 rpm
UPA 100C 2
UPA 100C 3
UPA 100C 4
UPA 100C 7
UPA 100C 12
24
UPA 100C
Materials
Component
Pump ...
Diffuser
Upper diffuser
Lower diffuser
Impeller
Pump shaft with Nema
coupling
Suction casing
Suction filter
Discharge casing
Spacer sleeve
Hook
Seal ringNBR + AISI 316
Upper bearing bushNBR + AISI 316
Intermediate bearing bushNBR
Val ve fac eNBR + AISI 316
Motor ...
Shaftstainless steel AISI 304 SS
Bearing housingstainless steel AISI 304 SS
Stator casestainless steel AISI 304 SS
C1 (stainless steel)
stainless steel AISI 304
Direction of Rotation of the Pump
Clockwise rotation (when looking at at the drive shaft end).
Drive
Typesubmersible canned motor
ConnectionNEMA standard
EnclosureIP 68
Frequency f50 Hz
Type of currentsingle-phase and three-phase
Rated voltage U1~ 230 V,
3~ 400 V,
Rated power P
Voltage fluctuationsup to +/-- 10 %
Frequency of startsup to 20 / h
Min. delay
before restarting3 min
A start box withintegrated phase-shiftingcapacitor andthermal
protection is included in the scope of supply of single-phase
pump sets in PSC design.
N
up to 7.5 kW
Starting Mode
Direct on line.
Temperatures
The UPA 100 Csubmersible boreholepump isdesigned foruse
in water with temperatures of up to +30 °C.
Permissible Cable Lengths
∆U up to 3 % and temperatures up to +30 °C.
Discharge Nozzle
UPA 100C
2 -- 3 -- 4:Rp 1’’
7--12Rp2’’
1
/
2
Installation
Vertical or horizontal installation without restriction.
In order to guarantee the dissipation of the motor heat it will be
necessary to install a device guiding the flow along the motor
(cooling jacket, flow inducer sleeve, etc.) in horizontal
installation.
Variants Available on Request
-- Higher fluid temperatures
-- Voltages above 500 V
-- Other frequencies
Type of current /
Voltage
1~ 230 V
50 Hz
3~ 400 V
50 Hz
Drive
rating
kW1.52.54.06.010.0
0.37
0.55
0.75
1.10
1.50
2.20
0.37
0.55
0.75
1.10
1.50
2.20
3.30
3.70
4.00
5.50
7.50
Length of cable in m for cross-
section in ... mm
72
120
100
79
50
43
32
--
-614
403
322
218
165
135
124
90
63
190
159
125
80
68
52
--
--
-645
516
350
265
215
195
143
100
60
47
30
26
20
752
483
368
242
194
131
100
80
74
55
38
2
248
236
186
118
101
77
--
--
--
--
-525
397
323
295
215
150
--
--
--
--
--
--
--
--
--
--
--
--
--
--
-597
415
25
Design Features
Optimised operating costs:
Check valve, built into the dis-
charge chamber, designed for low
loss of head.
Hydraulic profiles are optimized for
the attainment of high efficiencies.
UPA 100C
Resistance to corrosion and abrasion, i.e. the same inherent qualities
of stainless steel.
Oversized intermediate bearings
located at each pump stage to
align the shaft, specially designed
to optimize lubrication.
Coupling and flange suitable
for motors with pump mounting dimensions in accordance with NEMA standards.
Reliable in service:
Very strong construction: minimum
thickness of stainless sheet steel of
1 mm, 6 spot welding on each vane,
special top bearing for every pump.
Friendly service:
Great ease of dismantling and as-
sembly.
Easy-to-replace wear-rings and
bearings.
26
UPA 100C
aed
aed
UPA 100C 2 -- ...
D1
ØD1max:
Pump = 96.5 mm
Pump with motor
= 98.0 mm
-- 7 2
-- 6 6
-- 6 0
-- 5 4
-- 4 7
-- 4 0
-- 3 5
-- 3 0
-- 2 1
-- 1 7
-- 1 3
-- 8
UPA 100C 2 -- ...
(Tolerances to ISO 2548
Class C, Annex B)
-- 2 5
-- 6
RatedRated Rated current for
power
P
kW
0.37
0.37
0.55
0.75
1.1
1.1
1.5
1.5
2.2
2.2
2.2
3.0
3.0
3.0
power
(Motor)
P
N
HP
0.5
0.5
0.75
1.5
1.5
1~
220 V
N
I
3.2
3.6
5.7
1
6.9
8.0
8.9
2
9.5
2
11. 1
3
12.1
3
14.5
3
15.9
4
4
4
3~
400 V
1)
N
I
0.9
1.1
1.5
2.0
2.8
3.0
3.3
3.8
5.1
5.4
5.6
6.8
7.2
7.5
N
A
Operating range:
=0.5--2.5m3/h
Q
min
= End of characteristic curve
Q
max
A
--
--
--
(Motor)
Pump set
UPA 100C 2 --..
6
8
13
17
21
25
30
35
40
47
54
60
66
72
1)
Capacitor run motors (PSC motors) with starter.
Dimensions / Weights / Ident. Numbers
Pump set
UPA 100C 2 --..
6
8
13
17
21
25
30
35
40
47
54
60
66
72
A ≈ mm
349
397
517
623
711
807
928
1048
1169
1338
1506
1651
1796
1941
B ≈ mmC ≈ mmIdent. No.B ≈ mmC ≈ mmIdent. No.mA≈ kg
242
242
271
299
327
327
356
356
460
460
460
--
--
--
For horizontal installation, a device guiding the flow along the motor (cooling shroud, flow inducer sleeve, etc.) will be required.
1~ / 220 V3~ / 400 V
591
639
788
922
1038
1134
1284
1404
1629
1798
1966
--
--
--
90 065 300
90 065 301
90 065 302
90 065 303
90 065 304
90 065 305
90 065 306
90 065 307
90 065 308
90 065 309
90 065 310
--
--
--
223
223
242
271
299
299
327
327
356
356
356
423
423
423
572
620
759
894
1010
1106
1255
1375
1525
1694
1862
2074
2219
2364
90 065 387
90 065 388
90 065 389
90 065 390
90 065 391
90 065 392
90 065 393
90 065 394
90 065 395
90 065 396
90 065 397
90 065 398
90 065 399
90 065 400
11. 1
11.7
14.3
17.0
19.5
20.8
23.7
25.4
28.1
29.5
32.6
37.0
38.9
40.9
Accessories: UPA Control for dry running protection see page 32.
27
UPA 100C 3 -- ...
aed
aed
D1
ØD1max:
Pump = 96.5 mm
Pump with motor
= 98.0 mm
-- 6 8
-- 6 2
-- 5 7
-- 5 1
-- 4 4
-- 3 6
-- 3 0
-- 2 5
-- 2 2
-- 1 8
-- 1 5
-- 1 2
-- 9
-- 6
UPA 100C
UPA 100C 3 -- ...
(Tolerances to ISO 2548
Class C, Annex B)
RatedRated
power
(Motor)
Pump set
UPA 100C 3 --..
6
9
12
15
18
22
25
30
36
44
51
57
62
68
1)
Capacitor run motors (PSC motors) with starter.
P
kW
0.37
0.55
0.75
1.1
1.1
1.5
1.5
2.2
2.2
3.0
3.0
3.7
3.7
4.0
N
power
(Motor)
P
N
HP
0.5
0.75
1.0
1.5
1.5
2.0
2.0
3.0
3.0
4.00
4.0
5.0
5.0
5.5
Rated current for
1~
220 V
I
N
3.6
5.7
6.9
8.7
8.9
9.8
11. 1
12.5
15.9
3~
400 V
1)
I
A
N
A
1.1
1.5
2.0
2.9
3.0
3.6
3.8
5.2
5.6
--
7.0
--
7.2
--
8.8
--
9.1
--
10.00
Operating range:
Q
=1.0--3.5m3/h
min
= End of characteristic curve
Q
max
Dimensions / Weights / Ident. Numbers
Pump set
UPA 100C 3 --..
6
9
12
15
18
22
25
30
36
44
51
57
62
68
A ≈ mm
349
421
493
566
638
734
807
928
1072
1265
1434
1579
1699
1844
B ≈ mmC ≈ mmIdent. No.B ≈ mmC ≈ mmIdent. No.
242
271
299
327
327
356
356
460
460
--
--
--
--
--
1~ / 220 V3~ / 400 V
591
692
792
883
965
1090
1163
1388
1532
--
--
--
--
--
90 065 311
90 065 312
90 065 313
90 065 314
90 065 315
90 065 316
90 065 317
90 065 318
90 065 319
mA≈ kg
223
242
271
299
299
327
327
356
--
--
--
--
--
356
423
423
545
545
583
572
663
764
865
937
1061
1134
1284
1428
1688
1857
2124
2244
2427
90 065 401
90 065 402
90 065 403
90 065 404
90 065 405
90 065 406
90 065 407
90 065 408
90 065 409
90 065 410
90 065 411
90 065 412
90 065 413
90 065 414
11. 1
13.1
15.4
17.1
18.5
21.1
22.1
25.1
27.2
32.3
34.7
41.5
43.2
48.3
For horizontal installation, a device guiding the flow along the motor (cooling shroud, flow inducer sleeve, etc.) will be required.
Accessories: UPA Control for dry running protection see page 32.
28
UPA 100C
aed
aed
UPA 100C 4 -- ...
D1
ØD1max:
Pump = 96.5 mm
Pump with motor
= 98.0 mm
RatedRated
power
(Motor)
Pump set
UPA 100C 4 --..
4
7
9
14
19
24
29
34
39
45
50
54
60
66
72
1)
Capacitor run motors (PSC motors) with starter.
P
kW
0.37
0.55
0.75
1.1
1.5
2.2
2.2
3.0
3.0
3.7
3.7
4.0
5.5
5.5
5.5
N
power
(Motor)
P
N
HP
0.5
0.75
1.0
1.5
2.0
3.0
3.0
4.0
4.0
5.0
5.0
5.5
7.5
7.5
7.5
Rated current for
1~
220 V
I
N
A
3.6
5.7
6.9
8.9
11. 1
12.8
15.9
--
--
--
--
--
--
--
--
-- 7 2
UPA 100C 4 -- ...
(Tolerances to ISO 2548
-- 6 6
-- 6 0
-- 5 4
-- 5 0
-- 4 5
-- 3 9
-- 3 4
-- 2 9
-- 2 4
-- 1 9
-- 1 4
-- 9
-- 7
-- 4
3~
400 V
1)
I
N
A
1.1
1.5
2.0
3.0
3.8
5.3
5.6
7.0
7.2
8.8
9.1
10.0
11. 5
12.5
13.2
Operating range:
=1.0--5.0m3/h
Q
min
= End of characteristic curve
Q
max
Class C, Annex B)
Dimensions / Weights / Ident. Numbers
Pump set
UPA 100C 4 --..
4
7
9
14
19
24
29
34
39
45
50
54
60
66
72
A ≈ mm
300
373
421
542
662
783
903
1024
1145
1289
1410
1506
1651
1796
1941
B ≈ mmC ≈ mmIdent. No.B ≈ mmC ≈ mmIdent. No.
242
271
299
327
356
460
460
--
--
--
--
--
--
--
--
For horizontal installation, a device guiding the flow along the motor (cooling shroud, flow inducer sleeve, etc.) will be required.
Accessories: UPA Control for dry running protection see page 32.
1~ / 220 V3~ / 400 V
542
644
720
869
1018
1243
1363
--
--
--
--
--
--
--
--
90 065 320
90 065 321
90 065 322
90 065 323
90 065 324
90 065 325
90 065 326
--
--
--
--
--
--
--
--
223
242
271
299
327
356
356
423
423
545
545
583
698
698
698
523
615
692
841
989
1139
1259
1447
1568
1834
1955
2089
2349
2494
2639
90 065 415
90 065 416
90 065 417
90 065 418
90 065 419
90 065 420
90 065 421
90 065 422
90 065 423
90 065 424
90 065 425
90 065 426
90 065 427
90 065 428
90 065 429
mA≈ kg
10.5
12.5
14.5
17.4
20.4
23.5
25.2
29.4
31.1
38.0
39.7
44.3
51.6
53.7
55.7
29
UPA 100C
aed
aed
UPA 100C 7 -- ...
D1
ØD1max:
Pump = 96.5 mm
Pump with motor
= 98.0 mm
RatedRated
power
(Motor)
Pump set
UPA 100C 7 --..
3
4
6
9
13
16
19
23
26
29
32
34
39
44
49
54
59
64
1)
Capacitor run motors (PSC motors) with starter.
P
kW
0.37
0.55
0.75
1.1
1.5
2.2
2.2
3.0
3.0
3.7
3.7
4.0
5.5
5.5
5.5
7.5
7.5
7.5
N
power
(Motor)
P
N
HP
0.5
0.75
1.0
1.5
2.0
3.0
3.0
4.0
4.0
5.0
5.0
5.5
7.5
7.5
7.5
10.0
10.0
10.0
Rated current for
1~
220 V
I
N
3.6
5.7
6.9
8.9
11. 1
12.8
15.9
3~
400 V
1)
I
A
N
A
1.1
1.5
2.0
3.0
3.8
5.2
5.6
--
6.6
--
7.2
--
8.3
--
9.1
--
10.0
--
11. 5
--
12.5
--
13.2
--
17.5
--
18.3
--
19.1
Operating range:
Q
=2.0--8.0m3/h
min
= End of characteristic curve
Q
max
Dimensions / Weights / Ident. Numbers
Pump set
UPA 100C 7 --..
3
4
6
9
13
16
19
23
26
29
32
34
39
44
49
54
59
64
A ≈ mm
276
300
349
421
517
590
662
759
831
903
976
1024
1145
1266
1386
1506
1628
1748
B ≈ mmC ≈ mmIdent. No.B ≈ mmC ≈ mmIdent. No.
242
271
299
327
356
460
460
--
--
--
--
--
--
--
--
--
--
--
1~ / 220 V3~ / 400 V
519
571
648
748
873
1050
1122
--
--
--
--
--
--
--
--
--
--
--
90 065 327
90 065 328
90 065 329
90 065 330
90 065 331
90 065 332
90 065 333
UPA 100C 7 -- ...
-- 6 4
-- 5 9
-- 5 4
-- 4 9
-- 4 4
-- 3 9
-- 3 4
-- 3 2
-- 2 9
-- 2 6
-- 2 3
-- 1 9
-- 1 6
-- 1 3
-- 9
-- 6
-- 4
-- 3
223
242
271
299
327
356
--
--
--
--
--
--
--
--
--
--
--
356
423
423
545
545
583
698
698
698
774
774
774
500
542
620
720
844
946
1118
1182
1254
1448
1521
1607
1843
1964
2084
2280
2402
2522
(Tolerances to ISO 2548
Class C, Annex B)
90 065 430
90 065 431
90 065 432
90 065 433
90 065 434
90 065 435
90 065 436
90 065 437
90 065 438
90 065 439
90 065 440
90 065 441
90 065 442
90 065 443
90 065 444
90 065 445
90 065 446
90 065 447
mA≈ kg
10.2
11.5
13.5
15.8
18.5
21.0
22.0
25.9
27.0
33.0
34.0
37.9
45.0
46.8
48.6
53.9
55.7
59.5
For horizontal installation, a device guiding the flow along the motor (cooling shroud, flow inducer sleeve, etc.) will be required.
Accessories: UPA Control for dry running protection see page 32.
30