KSB S 100D, UPA 200B, UPA 100C, UPA 150S, UPA 200 Booklet

...
Type Series Booklet
3400.5/4--10 G3
50 Hz
Submersible Borehole Pumps
Applications
-- Drinking and service water supply
-- Irrigation and spray irrigation
-- Lowering and maintaining ground water levels
-- Fountains
-- Mining, offshore, tank farms
-- Building services systems
-- VDS sprinkler systems
Operating Data
Capacity Q up to 840 m3/h (233 l/s)..................
Head H up to 480 m.....................
Temperature of fluid handled t up to +50 °C..
Speed n 2900 rpm....................
Supply voltage U up to 10,000 V.............
Design
Single-- or multistage centrifugal pumps in pump shroud or in ring--section design. Radial or mixed flow hydraulic systems; reduced impeller diameters also available in some cases. The stage casings of radial pumps are connected by metal straps, those of mixed flow pumps by stud bolts. Suction casing fitted between pump and motor. Suction casing equipped with strainer to protect the pump from coarse particles in the fluid. Pumps with check valve or connection branch on option. Available with threaded or flanged end on option. Particularlysuitable forverticalinstallationinnarrow deepwells.
Submersible Borehole Pumps
S 100D, UPA 100C, UPA 150S, UPA 200,
UPA 200B, UPA 250C, UPA 300,
UPA 350, BSX -- BSF, UPZ
Pump Designation (Example)
UPA 200 B -- 8 0 /5 b
Type series Minimum well diameter (mm)
(for ex.: 200 mm = 8 inches)
Design status Capacity Q
Number of stages Reduced impeller diameters
1)
UPA 200 -11 + 14: Q in l/s.
(m3/h)--(4upto10inches)
opt
(l/s) -- (12 inches and above)
Motor Designation (Example)
UMA 250 D 110 /21
Type series Well diameter (mm)
(for ex. 250 mm = 10 inches)
Design status Rated power P Number of poles Winding insulation
N
(kW)
Certification
Quality management certified to ISO 9001
1)
Available automation products:
Hyamaster (UPA 150S -- UPA 350)
hyatronic (UPA 150S -- UPA 350)
switch gear (S 100D -- UPA 350)
Complete Range
The complete submersible borehole pump range comprises pump models for flow rates up to Q = 2500 m heads up to H = 1500 m. The submersiblemotor range coverssizes for powerratings up to P = 3500 kW and voltages up to U = 10,000 V for 50 and 60 Hz. In addition, a special range is available which features submersible motors with a higher number of poles.
3
/h (695 l/s) and
50 Hz Submersible Borehole Pumps
Contents Page
The Submersible Borehole Pump Range 4.....................................
Operation with Soft Starters 5................................................
Operation with Frequency Inverter 6...........................................
Typical Installation Positions 7................................................
Submersible Borehole Pump Selection for Deep Wells 8............................
Request for Quotation (Form) 9...............................................
Head Losses in the Piping 10.................................................
Pump Sets 4 inches 11 + 23.................................................
Pump Sets 6 inches 33......................................................
Pump Sets 8 inches/10 inches 49.............................................
Pump Sets 12 inches/14 inches 69............................................
Pump Sets 16 inches and above 83 + 87......................................
Typical Tenders: 4 to 14 inches 91.............................................
Submersible Motors 96......................................................
Accessories 98.............................................................
Flow Velocity “v” Past the Motor 108...........................................
2
Submersible Borehole Pumps50 Hz
What can you expect from the “Submersible Borehole Pumps Booklet”?
The information provided can help you make a
-- quick
-- first rough selection
-- on your own to find a suitable KSB submersible borehole pump for your
application. Wehave kept the volume of the catalogue down to what we think is the absolute minimum. For the 4 to 14 inch range, you will find the following information on the pump selected:
-- pump series, size and number of stages,
-- motor series, size, power, amperage, and allowable temperature,
-- starting method, supply voltage and type of installation,
-- material variants and
-- major dimensions and weights.
You may also complete, to the extent possible, the request for quotation on page 9.
You will then receive as soon as possible a detailed quotation and, if required, additional literature on KSB submersible borehole pumps from the nearest KSB sales branch.
Benefits at a Glance
+ Full range of products + High-tech equipment + Optimum material selection + Maximum efficiency + Functional reliability + Long service life + No maintenance + “Clean” technology + Customer focus
General
Information on fields of application, available models, type of installation, direction of rotation, coating, connection to power supply and speed controlis provided inthe detailed sectionsfor the relevant type series.
Pump Efficiency
The characteristic curves for UPA 200/200B and larger pumps show pump efficiency for themaximum and optimum (reduced) impeller diameter (for ex. ”c”). The efficiency of pumps with a low number of stages or considerably reduced impeller diameter (for ex. ”d”, “e”) is lower than the value shown; it is given in the individual characteristic curves specifically prepared for the quotation.
Dry Running Protection
For use in wells with marked water level fluctuations or temporary low yield we strongly recommend installing dry running protection equipment (”Accessories”).
Application Temperatures
The submersibleborehole pumps are, as a standard, suitablefor use in water with temperatures of up to t = +30 indispensable requirementfor this isa flow velocityof v = 0.2 m/s past the motor. This requirement is met, for example, when the pump is installed in a deep well above the well screen / filter, etc. With certain restrictions, some motor sizes may also be used in water with temperaturesof up tot = +50 without an adequate cooling flow of water past the motor, i.e. v = 0 m/s (for example, when the unit is installed in a deep well below the screen / filter area or in a pump sump, etc.).
The details below provide data of adequate accuracy for the allowable temperature as a function of the type of installation, motor size and flow velocity v past the motor:
Vertical installation:
-- DN 100 / DN 150: t
allow=tmax
-- UMA 150D/200D: v= 0m/s t v 0.2 m/s t v 0.5 m/s t
-- UMA 250D:
v = 0 m/s Please consult manufacturer,......
v 0.2 m/s t v 0.5 m/s t
1)
Values taken from tables on pages 15, 16 etc., 27, 28 etc..
1)
irrespective of flow past the motor.
t
allow allow allow
allow allow
max
=t
max
t
max
=t
max
t
max
o
C and for operation
1)
-- 5oC,......
1)
,.....
1)
+5oC......
1)
,.....
1)
,+5oC......
o
C. An
Horizontal installation:
The principle is the same as for vertical installation. Exception: Pumps with UMA 250D motors.
These units must always be equipped with a flow inducer sleeve. The flow inducer sleeve is not required, if the given pump is equipped with a motor having a 10 % higher power rating.
For all pump sets: For a flow velocity of v 0.5 m/s and horizontalinstallation, check back with the manufacturer.
3
The Submersible Borehole Pump Range
" UPV 200
UPV 150S "
(6 inch)
" UPA 100C
(4 inch) p. 23 -- 32
on request
50 Hz Submersible Borehole Pumps
" UPZ
BSX - BSF
(16 inch) p. 83 -- 90 on request
(8 inch) on request
" UPA 300, 350
(12/14 inch) p. 69 -- 82
" S 100D
(4 inch) p. 11 -- 22
UPA 200 "
(8/10 inch) p. 49 -- 57
" UPA 150S
(6 inch) p. 33 -- 48
" UPA 250C
(8/10 inch) p. 62 -- 68
" UPA 200B
(8/10 inch) p. 58 -- 61
4
Submersible Borehole Pumps50 Hz
Operation of KSB submersible motor pumps with soft starters
Soft starterelectronically reduce the incoming line voltage and, hence, the initial starting torque and starting current of electric motors. During run--up they gently ramp up the applied voltage to the motor. In the case of submersible motors, the extremely slim design and consequential small moments of inertia result in special characteristics, which differ strongly from normal asynchronous motors.
12.3 Soft starter settings
Effects on submersible borehole pumps
-- Starting current approx. 40% to 65% of IArequired for direct-starting.
-- Run-up time t with approx. 0.2s to 0.5s for direct. starting.
-- Starting torque M torque.
-- No current or torque peaks (I switching arrangement.
-- Hydraulic pressure surges (waterhammer) upon starting and stopping of the pump can be reduced, but not fully eliminated. Therefore, soft starters are not suitable for solving water hammer problems.
This would require the use of hydraulic control equipment or a frequency inverter. To prevent effects due to power failure, additional measures are required.
increased to approx. 1s to 3s compared
H
roughly 1/4 of the direct-starting
A
), as in star-delta
A,MA
Note
Conspicuous noiseor vibrations duringrun-up could well be an indication of incorrect settings on the soft starter. This might be due to exceeded ramp--up periods, incorrect operating mode (setting), activated special functions, etc.
Parameter / Function Setting Comments
Minimum starting voltage 40% of the motors’ rated voltage Ramp time / acceleration
(run--up) time Current limitation IA/INpreset to approx. 3.5 Should only be altered with allowance for
Deceleration (run--down) time / stop ramp
Special functions, e.g.:
-- special “pump function”
-- kick--start / boost function
-- speed adjustment
-- Current contoller
-- cos ϕ- / economy function
-- delayed starting
During operation the soft starter must be bridged (bypass). This helps to avoid losses at the machine and motor to secure proper permanent operation.
120
< 4s Ramp time is nor identical with the motor
Deceleration time tA< 4s Better without a ramp.
OFF Do not use, as they tend to be troublesome,
Run--up
Operation
actual run--up time
< 4s
t
H
particulary in submersible borehole applica­tions.
Run--down
100
80 60
40
Voltage [%]
20
0
4s
Time [s]
4s
5
Pump Operation with Frequency Inverter
3
0
203
0
50 Hz Submersible Borehole Pumps
In principle, the motors of submersible borehole pumps can also be run on a frequency inverter. As submersible motors differ from conventional standardized motors in terms of bearings, moment of inertia, insulation, temperature increase, loss distributionand heat distribution, the following parameters must be observed:
-- Maximum allowable acceleration time (start ramp)
-- Maximum allowable deceleration time (stop ramp)
-- Minimum frequency
-- Maximum operating frequency
-- Maximum permissible voltage increase velocity and peak voltages
-- Control principle of frequency inverter
Maximum Allowable Acceleration Time (Start Ramp) and Deceleration Time (Stop Ramp)
The plain bearings of the submersible motor do not tolerate operation below the minimum frequency f mixed lubrication range). For this reason, the acceleration period from standstill to minimum frequency f
should not exceed 2s. The same
min
applies to the deceleration period.
(operation in
min
Minimum Frequency
Minimum frequency f
Motor size
DN 100
Vertical
installation
30 DN 150 UMA 150D
20 30 UMA 200D UMA 250D UMA 300D /2 UMA 300D /4 30 35
(Hz)
min
Horizontal
installation
30
-- --
Maximum Operating Frequency
Frequency inverter operation above the nominal frequency (50Hz /60Hz) ofthe pumpunit must beavoided soas toprevent motor overload.
Maximum Permissible Voltage Increase Velocity and Peak Voltages
Excessive voltage increase velocities and excessive peak voltages will reduce the service life of the winding insulation. For this reason, the following limits must be adhered to:
-- Maximum voltage increase velocity: du/dt 500 V/µs
-- Maximum peak voltages to earth: Low-voltage motors 1 kV: J1 insulation 600 V
J2 insulation 800 V
For motor sizes DN 100 and DN 150, the limit values for J1 insulation apply.
Note: Compliance with these limits can usually be assured by means of a sine filter or
du
/dtfilter.
Control Principle of Frequency Inverter
The control principleof the frequency inverter must correspond to linear U/f curve control. If other control principles are employed, such as field-oriented inverters, inverters with DTC or NOF,the manufacturerof the frequency invertermust ensure that thespecial requirementsof submersiblemotors (very small moment of inertia, electrical data) are taken into account.
Note: For details refer to ”Design and Selection Information for Running Submersible Borehole Pumps on Frequency Inverters”, Ref. No. 3400.0610--10.
6
Typical Installation Positions
a) Vertical Installation
(deep well, pump sump, etc.)
CAUTION:
The construction of the well head must meet the relevant regulations ofthe competent authorities! The unit must never be installed with its suction strainer exactly at the level of the well screen / filter!
Before installingthe unitin narrowdeep wells werecommend to check narrow boreholes for dimensional accuracy over their entire length, e.g. by inserting a pipe of the length and biggest outside diameter of the pump unit. Sharp bends or bottlenecks can make installation difficult or even impossible. The unit is supported on the well head by supporting clamps (low-weight unitsand lowsubmergence) ora supportingflange. The construction of the well head must meet the relevant regulations of the competent authority.
5
8
Submersible Borehole Pumps50 Hz
Cooling / Suction shroud
Fig. 2 Installation in a pump sump
3400:50
4
6
H
h
H
t
3
B
B
7
H
e
X
2
T
1
1 Submersible borehole pump
F
T
B
2 Riser pipe 3 Cable tie
9
4 Supporting flange / Well head 5 Pressure gauge 6 Shut-off valve 7 Power supply cable 8 Control box 9 Well screen / filter
D
3410:70/4
D = Inside well diameter T
= Well depth
B
= Well screen / filter depth
T
F
H
= Installation depth
e
H
= Static water level
h
= Dynamic water level (Pumping water level)
H
t
Fig. 1 Vertical installation (in deep well, pump sump, etc.)
The suspension arrangement of the pump unit must be designed and dimensionedso that allstatic anddynamic forces can be absorbed and that theriser pipe cannot slip downwards. The supporting clamps or flanges must be fastened at the well head so that they cannot shift of lift off the well head.
The unit mustnever be installed with its suction strainer exactly at the level of the well screen / filter! Excessive flow in the area of the well screen / filter entails the risk of large amounts of entrained sand clogging the well screen / filter and causing excessive wear in the pump.
Pump units installed in a pump sump must generally be equipped with a cooling or suction shroud (fig. 2).
b) Horizontal Installation
(in reservoirs, mine shafts, etc.)
CAUTION:
The instructions given in ”a) Vertical installation” shall also apply by analogy to horizontal installation, when the pump unit is fitted on mounts (pedestals / supporting frame) supplied by us. If the pump and motor are supplied ready mounted on a supporting frame, on-site alignment of pump and motor will not be necessary. If this is not the case, the relevant installation / assembly drawing must be ordered, giving the following details:
-- installation height (floor clearance),
-- spacing of supports,
-- submergence X The ground / foundation must be level and of sufficient
load-bearing capacity to accept the weight of the unit with supports.
Air intake from an inlet arranged above the water level is not permitted.
X
3410:71/2
Fig. 3 Horizontal installation (in tanks, mine shafts etc.)
1 Submersible borehole pump 2 Water storage tanks (UMA 300D and 14D motors only) 3 Pedestal 4 Expansion joint 5 Check valve
(only if pump unit does not have its own check valve) 6 Dismantling joint 7 Shut-off valve 8 Intake
7
50 Hz Submersible Borehole Pumps
Submersible Borehole Pump Selection for Deep Wells
Pump Selection
The following data are required for a first rough selection of a submersible borehole pump:
-- Capacity Q in m
-- Pressure at well head H
-- Well diameter in inches or mm
-- Temperature of fluid handled t
-- Pump head HPin m While Q, H
head H
A
to be developed by the pump needs to be calculated.
P
There are two typical applications to be considered (see the drawing on the right):
1. Pumping into an open overhead tank
HP=HA+Ht+Hv+HS[m]
where ... HA= Required pressure at well head H
= Lowest water level (dynamic water level)
t
Hv= Head losses in the checkvalve (see characteristic
H
= Head losses in riser pipe up to well head
S
H
= Installation depth
e
3
/h (l/s)
in m
A
in °C
A
, D and tAare usually specified bythe customer,the
curves for different stage numbers for UPA 150S and above).
(see page 10).
2. Pumping into a closed tank
Hp=HA+Ht+Hv+HS+pü[m]
where ... pü= Gauge pressure (also air cushion) in a tank
Example
Given ... QA= 120 m3/h,
=95m,
H
A
tA=+15°C, 50 Hz, 400 V and d.o.l. starting,
well diameter D = 250 mm (10 inches).
...
Found
1. step: pump type UPA 200B/250C (for Q
2. step: pump size UPA 200B - 130 (for QAtaken from selection chart on page 50)
3. step: pump set UPA 200B-130/6b + UMA 200D 45/21 (for Hp=HA+Ht+HV+HS= 95 + 4 + 0.75 + 0.26 = 100 m with H numbers on page 61). Pump efficiency: ηP= 80.5 % (without check valve)
taken from selection chart on page 4)
A
taken from characteristic curves for different stage
V
3300:54/3
Figure: Deep well with submersible borehole pump and overhead tank or closedtank at apressure above atmospheric pressureof p
ü.
8
50 Hz Submersible Borehole Pumps
Request for Quotation
We should like to test the efficiency and quality of your computer-aided quotation process. Please let us have a quotation based on the following data. (Fill in the required data and / or underline the relevant information, as far as available.)
1. Water quality
Discharge head required at theend of the piping:
Temperature °C.....................
8
Sand content g/m
..................
H = m ( bar)............. ........
3
Cut-out pressure in the pressure vessel:
Please attach water analysis, if available.
p
= bar............
Ü
2. Type of system
7
6
Well / Mine shaft / Tank Free discharge above ground Discharge into an overhead tank Discharge into a pressure vessel
c)Piping outside well head housing:
Overall length m....................
Nominal diameter mm...............
Number of bends, valves and fittings:
pcs................................
3. Deep well
Well depth(distance from ground level to
5
well base): T
=m............................
B
Inside diameter at submersible pump installation depth:
D = mm ( inches).............. ....
4
Well screen / filter:
-- Installation depth T
=m...........
F
Inside diameter reduced by incrustation
to: D = mm........................
6. Installation depth
Ground level to check valve / to connection branch:
He = m............
Caution: Do not install the submersible borehole pump at the level of the well screen / filter!
F
1 Well screen / filter 2 Well casing 3 Submersible borehole pump 4 Riser 5 Well head housing 6 Well head 7 Power supply cable 8 Overhead tank
3
2
1
3300:54/3
-- Length L
=m...................
F
4. Capacity
Q= m3/h ( l/s)............. .......
5. Total head
(including all friction losses)
H= m............................
If H is not known, please provide the following data:
a) Water level in well, measured from ground level:
-- Static water level: H
-- Dynamic water level: H (at capacity Q = m
b) Head above ground: Geodetic altitude up to the highest point of the pipeline or up to the highest water level in the overhead tank: H
=m...........................
d
=m..........
h
=m........
t
3
/h)..............
7. Power supply
Single- / three-phase alternating current. Mains voltage at well:
U= V.............................
Frequency f = Hz..................
If voltage drops cannot be precluded:
Minimum voltage ...
U
=V...........
min
8. Control box
Manual start-up / remote control / auto­matic start-up by way of float switch, pressure switch or dry running protection equipment.
Other types of switchgear: ...........
...................................
9. Starting method
D.o.l. (without / with autotransformer or soft starter) or star-delta starting.
9
Head losses in the piping
H
V
m/100 m
50 Hz Submersible Borehole Pumps
H
V
ft/100 ft
The frictionlosses givenin theabove chart roughlyapply tonew cast iron pipes.For newrolled steelor plasticpipes, multiply the values by approx. 0.8. For old, slightly rusty cast iron pipes, multiply by approx. 1.25. In pipes with incrustations, friction losses may rise to 1.7 times the value given in the chart for the
10
3300:103/3-2
diameter reduced by incrustations. For pipes subject to con­siderable incrustation, the friction losses can only be deter­mined experimentally. Example: Q = 140 m
H
V
3
/h, new DN 150 cast iron pipe.
= 3.25 m per 100 m of pipe, v = 2.2 m/sec.
50 Hz S 100D
Applications
-- Domestic and general water supply
-- Irrigation and spray irrigation
-- Lowering groundwater levels
-- Fountains
-- Pressure boosting
-- Air-conditioning systems
-- Fire protection
-- Cooling water cycles
Operating Data
Caoacity Q up to 16 m3/h Head H up to 300 m Temperature of fluid handled
tupto+30°C in continuous operation
Power Pn up to 5.5 kW
Pump Type / Design
Pump:
Stainless steel and plastic multistage centrifugal pump.
-- Additional bearing depending on the number of stages
-- Pump sizes D1 and D2 with anti-blockage feature. This con­sists of a hexagonal polyurethane disc mounted to the back of the diffuser. A PE-HD ring fitted to the impeller front side sits closeto thedisc. The impeller hub is protected by apoly­urethane ring.This design improves the starting torque of low­capacity pumps and has the effect that solid particles such as sand are propelled outside instead of clogging the pump.
Motor:
Submersible canned motor (Franklin), NEMA standard, 50 Hz
-- For single-phase alternating current (type PSC) or three­phase current
-- With short cable
-- Connection to power supply mains by means of cable con­nector (accessories)
-- D.o.l. starting, start-up frequency up to 20/h
-- Type of enclosure IP 68
-- Thermal class B
Submersible Borehole Pumps
for Well Diameters of 100 mm (4 inch)
Designation
S 100 D -- 4 / 6
Type series
Well diameter (mm)
Status
Capacity (m
Number of stages
3
/h)
Recommended Accessories
UPA Control: Control box for motor and dry running protection
by immersion electrodes. Automatic control unit: in conjunction with the Controlmatic E or Cervomatic EDP control and monitoring units, which pro­tect thepump againstdry running, ifthe waterlevel falls,S 100D can be used for automatic water supply
Certification
Quality management certified to ISO 9001
Available automation products:
Automatic control unit
Product Features
-- Pumps sizes D1 and D2 with anti-blockage feature
-- Rust-proof
-- Suitable for installation in narrow deep wells
-- High efficiency
-- Hermetically sealed motor
-- Motor designed for maximum pump output
-- Low noise level
-- For vertical, angled or horizontal installation
-- Check valve with anti-blockage valve disc
11
50 Hz S 100D
Selection Chart (Ranges on Offer) n 2900 rpm
Note:
Up to a motor rating of PN= 2.2 kW, all pump sizes can be supplied with either single-phase a.c. or three-phase current motors.
12
50 Hz S 100D
Materials
Component
Pump ...
Outer pump casing/ Suction casing / Valve housing
Stage casing CrNi steel (1.4301) Stage casing (diffuser) /
Impeller Shaft Cr-steel (1.4021) Bearing bush Nitril NBR 80 Screws, bolts and nuts CrNiMo-steel (A4--70)
Motor ...
Shaft CrNi steel (1.4305) Bearing carrier CrNi steel (1.4301) Stator case CrNi steel (1.4301)
G (Standard design)
CrNi steel (1.4301)
glass fibre reinforced Noryl
(PPO)
Bearings / Lubrication
Plain bearings, lubricated by the fluid pumped or by the motor fill liquid. Depending on the number of stages, an additional in­termediate bearing is provided in the pump. The axial thrust is balanced by a thrust bearing in the motor. The hydraulic thrust is balanced by the pump’s counter thrust bearing.
Direction of Rotation of the Pump
Clockwise rotation (viewed at the drive shaft end).
Pump End (Discharge Nozzle)
S 100D - 1, 2, 4 + 7: Internal thread G 1’’1/4(DN 32). S 100D - 12: Internal thread G 2’’ (DN 50).
Drive
Type canned motor in squirrel-....................
cage design, 2 poles
Connection NEMA standard..............
Type of enclosure IP 68........
Frequency 50 Hz..............
Type of current single-phase a.c. (1
or three-phase (3
Rated voltage U 220 ... 230 V (1~) and..........
380 ... 400 V (3~) Rated power P
Voltage fluctuation up to ± 5 % acc. to VDE........
Frequency of starts up to 20/h.......
Min. delay before restarting 3 min. A starter for single-phase a.c. motors in PSC design (with
integrated run capacitor and motorprotection) is included inthe scope of supply.
N
up to 2.2 kW for 1~ and............
up to 5.5 kW for 3~
µ)...........
µ)
Connection to Power Supply
All DN 100 motors are factory-equipped as follows: 1 x 1.5 mflatcable, quality 4x 1.5 mm2(3 phases + 1 earthcon­ductor). Exception: DN 100 motors with a rating of 5.5 kW, 3~, are equipped as follows: 2.5 m cable, quality 4 x 1.5 mm
Connection of extensioncable (any length)by meansof a cable connector
Connected at the factory by means of a standard cable con-
nector (non-separable, shrink tube)
Ident. No. 40 980 708
For cable quality 4 x 1.5 mm
Ident. No. 39 020 536
For cable quality 4 x 4 mm
Connected at the factory with Franklin cable connector
(separable, sealing compound)
Ident. No. 90 049 385
For cable quality 4 x 1.5 mm
2
or 4 x 2.5 mm
2
2
up to 4 x 2.5 mm
2
.
2
2
Installation
Vertical and, depending on the number of stages, also angled and horizontal installation.
Starting Mode
Only direct on line.
Temperatures
The S 100D submersible borehole pump is designed for use in water with temperatures of up to t = + 30
o
C.
Variants Available on Request
-- Higher fluid temperatures
-- Higher voltages up to 500 V
-- Other frequencies
13
Design Features
50 Hz S 100D
Easy to commission and service
D Vent valve for operation with automatic
control units such as Controlmatic E or Cervomatic EDP
D Easy to install thanks to plug--type
connection of power cable of Franklin submersible motor
D The cable guard is easy to fit and remove.
High operating reliability and long service life
D Maintenance--free and wear--protected
pump bearings
D Special guide feature prevents jamming
or tilting of the check valve
D Cable guard protects cables from damage.
Highly corrosion--resistant
D Suction casing, check valve
housing and outer casing made of stainless steel
D Hydraulic system made of glass
fibre reinforced Noryl
14
S 100D -- 1 ...
(motor)
ith
for well diameters of 100 mm (4 inch) Pumps with submersible motors for ...
-- Temperature of fluid handled up to + 30oC............
-- Current / Operating voltage 1~/230 V..................
or 3~/400 V.......................................
-- Starting direct......................................
50 Hz S 100D
Rated power
Current intensity for
...
Installa-
2)
tion
Oper-
ation
w
control
unit
3
Pump unit S 100D
P
kW
1~
230 V
1)
N
I
N
A
3~
400 V
I
N
A
1/ 7 0.37 3.4 1.3 v+h x 1/ 9 0.37 3.4 1.3 v+h x 1/12 0.55 3.4 1.3 v+h x 1/14 0.55 4.3 1.7 v+h x 1/16 0.55 4.3 1.7 v+h x 1/20 0.75 4.3 1.7 v+h x 1/25 1.10 5.7 2.2 v x 1/30 1.10 5.7 2.2 v x 1/35 1.50 8.6 3.2 v x 1/40 1.50 8.6 3.2 v x 1/50 2.20 10.6 4.0 v x
1)
Capacitor run motors (PSC motors) with starter.
2)
v = vertical and h = inclined / horizontal.
3)
Always check and make sure that the operating pressure of Controlmatic / Cervomatic units is not exceeded.
4)
3~ only
3)4)
Note : Use a cooling shroud for horizontal installation.
)
3)
3)
3)
3)
3)
3)
Capacity
Dimensions / Weights / Ident. Numbers / Horizontal Installation
1~/ 230 V 3~/ 400 V
Pump unit S 100D
1/ 7
1/ 9
1/ 12
1/ 14
1/ 16
1/ 20
1/ 25
1/ 30
1/ 35
1/ 40
1/ 50
For information on cooling shroud refer to page 20.
L
A
mm
575
625
720
795
810
925
1100
1210
1395
1505
1805
m
kg
11. 5
11.7
13.4
13.6
13.8
14.3
16.3
16.8
20.0
20.6
22.7
A
Ident No. A
39 022 528
39 022 529
39 022 530
39 022 531
39 022 532
39 022 533
39 022 534
39 022 535
39 022 536
39 022 537
39 022 538
mm
371
425
508
552
597
687
-- -- -- --
-- -- -- --
-- -- -- --
-- -- -- --
-- -- -- --
L
A
mm
555
605
700
755
780
870
1045
1150
1310
1450
1705
m
kg
10.7
10.9
12.2
12.4
12.6
13.1
14.9
15.4
17.4
18.0
20.3
A
Ident No. A
39 022 565
39 022 566
39 022 567
39 022 568
39 022 569
39 022 570
39 022 571
39 022 572
39 022 573
39 022 574
39 022 575
mm
362
416
492
537
582
672
-- -- -- --
-- -- -- --
-- -- -- --
-- -- -- --
-- -- -- --
C
G1”1/4
Accessories: UPA Control for dry running protection using 1 or 3 immersion electrodes, see page 21.
15
S 100D -- 2 ...
p
for well diameters of 100 mm (4 inch)
50 Hz S 100D
Pumps with submersible motors for ...
-- Temperature of fluid handled up to + 30
-- Current / Operation voltage 1~/230 V..................
or. 3~/400 V......................................
-- Starting direct......................................
Pump unit S 100D
Rated power
(motor)
P
kW
N
Current intensity
for ...
1~
230 V
I
N
A
1)
3~
400 V
I
N
A
Instal-
lation
2)
Opera-
tion with
control
unit
3
2/ 7 0.37 3.4 1.3 v+h x 2/11 0.55 4.3 1.7 v+h x 2/15 0.75 5.6 2.2 v+h x 2/18 1.1 8.6 3.2 v+h x 2/20 1.1 8.6 3.2 v+h x 2/22 1.1 8.6 3.2 v+h x 2/27 1.5 10.6 4.0 v+h x 2/30 1.5 10.6 4.0 v x 2/33 2.2 15.5 5.9 v x 2/38 2.2 15.5 5.9 v x 2/44 2.2 15.5 5.9 v x 2/50 3.0 -- 7.8 v x
1)
Capacitor run motors (PSC motors) with starter.
2)
v = vertical and h = inclined / horizontal.
3)
Always check and make sure that the operating pressure of Controlmatic / Cervomatic units is not exceeded.
4)
3~ only
3)
3)
3)
3)
3)
3)
3)
3)
3)4)
Note : Use a cooling shroud for horizontal installation.
o
C............
)
Capacity
Dimensions / Weights / Ident. Numbers / Horizontal Installation
1~/ 230 V 3~/ 400 V
Pump unit S 100D
2/ 7
2/11
2/15
2/18
2/20
2/22
2/27
2/30
2/33
2/38
2/44
2/50
For information on cooling shroud refer to page 20.
L
A
mm
570
695
815
940
985
1030
1175
1235
1425
1535
1670
-- -- -- -- --
m
A
kg
11. 3
13.0
14.8
17.7
17.8
18.0
19.5
19.9
23.6
24.1
24.6
-- -- -- -- --
Ident No. A
39 022 539
39 022 540
39 022 541
39 022 542
39 022 543
39 022 544
39 022 545
39 022 546
39 022 547
39 022 548
39 022 549
-- -- -- -- --
mm
371
484
589
684
729
775
901
-- -- -- --
-- -- -- --
-- -- -- --
-- -- -- --
-- -- -- --
L
A
mm
550
665
790
880
925
970
1120
1180
1325
1435
1570
1770
m
kg
10.5
11.8
13.4
15.1
15.2
15.4
17.1
17.5
19.0
19.5
20.0
23.6
A
Ident No. A
39 022 576
39 022 577
39 022 578
39 022 579
39 022 580
39 022 581
39 022 582
39 022 583
39 022 584
39 022 585
39 022 586
39 022 587
mm
362
470
574
655
701
746
873
-- -- -- --
-- -- -- --
-- -- -- --
-- -- -- --
-- -- -- --
C
G1”1/4
Accessories: UPA Control for dry running protection using 1 or 3 immersion electrodes, see page 21. 16
S 100D -- 4 ...
p
for well diameters of 100 mm (4 inch)
50 Hz S 100D
Pumps with submersible motors for ...
-- Temperature of fluid handled up to + 30
-- Current / Operating voltage 1~/230 V..................
or 3~/400 V......................................
-- Starting direct......................................
Pump unit S 100D
Rated power
(motor)
P
kW
N
Current intensity
for ...
1~
230 V
I
N
A
1)
3~
400 V
I
N
A
Instal-
lation
2)
Opera-
tion with
control
unit
3)
4/ 3 0.37 3.4 1.3 v+h x 4/ 6 0.55 4.3 1.7 v+h x 4/ 8 0.75 5.7 2.2 v+h x 4/11 1.10 8.6 3.2 v+h x 4/16 1.50 10.6 4.0 v+h x 4/21 2.20 15.5 5.9 v+h x 4/24 2.20 15.5 5.9 v x 4/33 3.00 -- -- -- 7.8 v x 4/40 3.70 -- -- -- 9.1 v x
1)
Capacitor run motors (PSC motors) with starter.
2)
v = vertical and h = inclined / horizontal.
3)
Always check and make sure that the operating pressure of Controlmatic / Cervomatic units is not exceeded.
4)
3~ only
3)4)
3)4)
3)4)
3)4)
3)4)
Note : Use a cooling shroud for horizontal installation.
o
C............
Capacity
Dimensions / Weights / Ident. Numbers / Horizontal Installation
1~ / 230 V 3~ / 400 V
Pump unit S 100D
4/ 3
4/ 6
4/ 8
4/11
4/16
4/21
4/24
4/33
4/40
For information on cooling shroud refer to page 20.
L
A
mm
505
610
690
820
975
1180
1255
-- -- -- --
-- -- -- --
m
kg
11. 5
13.4
15.1
18.2
20.1
24.8
25.3
-- -- -- --
-- -- -- --
A
Ident No. A
39 022 550
39 022 551
39 022 552
39 022 553
39 022 554
39 022 555
39 022 556
-- -- -- -- --
-- -- -- -- --
mm
333
399
489
594
734
900
-- -- -- --
-- -- -- --
-- -- -- --
L
A
mm
485
580
665
760
920
1080
1155
1595
1805
m
kg
10.7
12.2
13.7
15.6
17.7
20.2
20.7
25.5
33.0
A
Ident No. A
39 022 588
39 022 589
39 022 590
39 022 591
39 022 592
39 022 593
39 022 594
39 022 595
39 022 596
mm
324
384
475
566
706
847
-- -- -- --
-- -- -- --
-- -- -- --
C
G1”1/4
Accessories: UPA Control for dry running protection using 1 or 3 immersion electrodes, see page 21.
17
S 100D -- 7 ...
p
for well diameters of 100 mm (4 inch)
50 Hz S 100D
Pumps with submersible motors for ...
-- Temperature of fluid handled up to + 30
-- Current / Operating voltage 1~/230 V..................
or 3~/400 V.......................................
-- Starting direct......................................
Pump unit S 100D
Rated power
(motor)
P
kW
N
Current intensity
for ...
1~
230 V
I
N
A
1)
3~
400 V
I
N
A
Instal-
lation
2)
Opera-
tion with
control
unit
3)
7/ 4 0.75 5.7 2.2 v+h x 7/ 6 1.10 8.6 3.2 v+h x 7/ 8 1.50 10.6 4.0 v+h x 7/11 2.20 15.5 5.9 v+h x 7/13 2.20 15.5 5.9 v+h x 7/18 3.00 -- -- -- 7.8 v+h x 7/23 3.70 -- -- -- 9.1 v x 7/28 5.50 -- -- -- 13.7 v x 7/33 5.50 -- -- -- 13.7 v x
1)
Capacitor run motors (PSC motors) with starter.
2)
v = vertical and h = inclined / horizontal.
3)
Always check and make sure that the operating pressure of Controlmatic / Cervomatic units is not exceeded.
4)
3~ only
4)
4)
4)
3)4)
3)4)
3)4)
3)4)
Note : Use a cooling shroud for horizontal installation.
o
C............
Capacity
Dimensions / Weights / Ident. Numbers / Horizontal Installation
1~ / 230 V 3~ / 400 V
Pump unit S 100D
7/ 4 7/ 6 7/ 8 7/11 7/13 7/18 7/23
7/28
7/33
For information on cooling shroud refer to page 20.
L
A
mm
611
736
831
1011
1076
-- -- -- --
-- -- -- --
-- -- -- --
-- -- -- --
m
kg
14.6
17.7
19.1
23.1
23.6
-- -- -- --
-- -- -- --
-- -- -- --
-- -- -- --
A
39 022 557
39 022 558
39 022 559
39 022 560
39 022 561
Ident No. A
mm
421
517
599
740
808
-- -- -- -- --
-- -- -- -- --
-- -- -- -- --
-- -- -- -- --
-- -- -- --
-- -- -- --
-- -- -- --
-- -- -- --
L
A
mm
586
676
776
911
976
1211
1516
1881
2051
m
kg
13.2
15.1
16.7
18.5
19.0
23.1
30.8
38.3
39.4
A
Ident No. A
39 022 597
39 022 598
39 022 599
39 022 600
39 022 601
39 022 602
39 022 603
39 022 604
39 022 605
mm
407
489
571
687
755
958
-- -- -- --
-- -- -- --
-- -- -- --
C
G1”1/4
Accessories: UPA Control for dry running protection using 1 or 3 immersion electrodes, see page 21. 18
S 100D -- 12 ...
p
for well diameters for 100 mm (4 inch)
50 Hz S 100D
Pumps with submersible motors for ...
-- Temperature of fluid handled up to + 30
-- Current / Operation voltage 1~/230 V..................
or 3~/400 V.......................................
-- Starting direct......................................
Pump unit S 100D
Rated
power
(motor)
P
N
kW
Current intensity
for ...
1~
230 V
I
400 V
1)
N
A
3~
I
A
Installa-
tion
2)
Operation
with
control
unit
3)
N
12 / 4 1.1 8.6 3.2 v+h x 12 / 6 1.5 10.6 4.0 v+h x 12 / 10 2.2 15.5 5.9 v+h x 12 / 13 3.0 -- -- -- 7.8 v x 12 / 17 3.7 -- -- -- 9.1 v x
4)
3)4)
12 / 21 5.5 -- -- -- 13.7 v -- -- -­12 / 25 5.5 -- -- -- 13.7 v -- -- --
1)
Capacitor run motors (PSC motors) with starter.
2)
v = vertical and h = inclined / horizontal.
3)
Always check and make sure that the operating pressure of Controlmatic / Cervomatic units is not exceeded.
4)
3~ only
Note : Use a cooling shroud for horizontal installation.
o
C............
Capacity
Dimensions / Weights / Ident. Numbers / Horizontal Installation
1~ / 230 V 3~ / 400 V
Pump unit S 100D
12 / 4
12 / 6
12 /10
12 /13
12 /17
12 /21
12 /25
For information on cooling shroud refer to page 20.
L
A
mm
865
1000
1295
-- -- --
-- -- --
-- -- --
-- -- --
m
kg
17.3
19.3
24.6
-- -- --
-- -- --
-- -- --
-- -- --
A
Ident No. A
39 022 562
39 022 563
39 022 564
-- -- --
-- -- --
-- -- --
-- -- --
mm
613
739
991
-- -- --
-- -- --
-- -- --
-- -- --
L
A
mm
805
945
1195
1425
1815
2185
2400
m
kg
14.7
16.9
20.0
24.2
32.2
40.2
42.0
A
Ident No. A
39 022 606
39 022 607
39 022 608 39 022 609 39 022 610
39 022 611
39 022 612
mm
585
707
938
-- -- --
-- -- --
-- -- --
-- -- --
C
G2”
Accessories: UPA Control for dry running protection using 1 or 3 immersion electrodes, see page 21.
19
50 Hz S 100D
ootoupto05(
)
Ø115(130)x500
9006549
1
p
Ø115(130)x800
9006549
3
Scope of Supply for Single--phase A.C. Motors DN 100 (1~)
A starter for single-phase a.c. motors in PSC design (with integrated run capacitor and motorprotection) is included inthe scope of supply.
Permissible Cable Lengths
Uupto3%,directstartingandtupto+30
Current /
Voltage
1~/
230 V
(PSC)
3~/
400 V
Motor rating
kW 1.5 2.5 4.0 6.0
0.37
0.55
0.75
1.10
1.50
2.20
0.37
0.55
0.75
1.10
1.50
2.20
3.00
3.70
5.50
72 m 60 m 47 m 30 m 26 m 20 m
752 m 483 m 368 m 242 m 194 m 131 m 100 m
80 m 55 m
Cable lengths for
cable cross--section in ... mm
120 m 100 m
79 m 50 m 43 m 32 m
614 m 403 m 322 m 218 m 165 m 135 m
90 m
o
C
2
190 m 159 m 125 m
80 m 68 m 52 m
--
--
645 m 516 m 350 m 265 m 215 m 143 m
284 m 236 m 186 m 118 m 101 m
77 m
--
--
--
--
--
--
--
-­525 m 397 m 323 m 215 m
Technical Data -- Cooling Shroud
Pump unit S 100D
1/7 to 1/20 1/25 to 1/30
2/7 to 2/15 4/3 to 4/8 7/4
1/35 to 1/50 v 2/18 to 2/27
2/30 4/11 to 4/16
7/6 to 7/8 12/4 to 12/6
2/33 to 2/50 4/21 4/24 to 4/33 7/11 to 7/18 12/10 12/13
4/40 v 7/23 to 7/33
12/17 to 12/25
1)
v = vertical, h = inclined / horizontal
Installation1)Dimension (dia. x length)
and motor type (kW)
v+h
v
v+h v+h v+h
v+h
v
v+h v+h v+h
v
v+h
v v+h v+h
v
v
v
Ø115 (130) x 400 for motor up to 0.75 kW (1~) or up to 0.75 kW (3~) Weight 1.5 kg
Ø115 (130) x 500 90 065 491 for motor up to 1.5 kW (1~) or up to 1.5 kW (3~) Weight 1.7 kg
Ø115 (130) x 625 for motor up to 2.2 kW (1~) or up to 3.0 kW (3~) Weight 2.0 kg
Ø115 (130) x 800 90 065 493 for motor up to 5.5 kW (3~) Weight 2.5 kg
Cooling Shroud Ident No.
90 065 490
90 065 492
Strainer Ident No.
90 065 494
Ø115x117
0.3 kg
Support feet Ident No.
90 065 495
Set = 2 pc.
0.6 kg
20
50 Hz S 100D
Accessories: UPA Control for Dry Running Protection (using 3 immersion electrodes)
S 100D-1/.. 1~ S 100D-1/... 3~
Relais
Télémécanique
(A)
2.5to4.0 (3) X 40 980 891 1.0to1.6 (3) X 40 980 887
4.0to6.0 (3) X 40 980 893 1.6to2.5 (3) X 40 980 889
5.5to8.0 (3) X 40 990 895 2.5to4.0 (3) X 40 980 891
7.0to10 (3) X 40 980 897
9.0to13 (3) X 40 980 899
Electrode
(Qty.)
S 100D-2/.. 1~ S 100D-2/... 3~
Relais
Télémécanique
(A)
2.5to4.0 (3) X 40 980 891 1.0to1.6 (3) X 40 980 887
4.0to6.0 (3) X 40 980 893 1.6to2.5 (3) X 40 980 889
5.5to8.0 (3) X 40 990 895 2.5to4.0 (3) X 40 980 891
7.0to10 (3) X 40 980 897 5.5to8.0 (3) X 40 980 895
9.0to13 (3) X 40 980 899 12 to 18 (3) X 40 984 811
Electrode
(Qty.)
7
14
9
16
12
20
7 11 15
253035
18 20 22
Relais
40
50
Ident No.
33 38
27
44
30
Ident No.
Télémécanique
(A)
Relais
Témécanique
(A)
Electrode
(Qty.)
Electrode
(Qty.)
7
14
9
12
30
11 15
7
35 40
to
50
18
33 44
to
50
30
Ident No.
Ident No.
S 100D-4/.. 1~ S 100D-4/... 3~
Relais
Télémécanique
(A)
2.5to4.0 (3) X 40 980 891 1.0to1.6 (3) X 40 980 887
4.0to6.0 (3) X 40 980 893 1.6to2.5 (3) X 40 980 889
5.5to8.0 (3) X 40 990 895 2.5to4.0 (3) X 40 980 891
7.0to10 (3) X 40 980 897 5.5to8.0 (3) X 40 980 895
9.0to13 (3) X 40 980 899 7.0 to 10 (3) X 40 980 897 12 to 18 (3) X 40 984 811
Electrode
(Qty.)
3 6 8
11 16
21 24
Ident No.
Relais
Télémécanique
(A)
Electrode
(Qty.)
681116212433
3
40
Ident No.
S 100D-7/.. 1~ S 100D-7/... 3~
Relais
Télémécanique
(A)
5.5to8.0 (3) X 40 990 895 1.6to2.5 (3) X 40 980 889
7.0to10 (3) X 40 980 897 2.5to4.0 (3) X 40 980 891
9.0to13 (3) X 40 980 899 5.5to8.0 (3) X 40 980 895 12 to 18 (3) X 40 984 811 7.0to10 (3) X 40 980 897
Electrode
(Qty.)
4 6 8
11
13
Ident No.
Relais
Télémécanique
(A)
12 to 18 (3) X 40 984 811
Electrode
(Qty.)
4
11
6
13
8
18
28 33
23
Ident No.
S 100D-12/.. 1~ S 100D-12/... 3~
Relais
Télémécanique
(A)
7.0to10 (3) X 40 980 897 2.5to4.0 (3) X 40 980 891
9.0to13 (3) X 40 980 899 5.5to8.0 (3) X 40 980 895 12 to 18 (3) X 40 984 811 7.0to10 (3) X 40 980 897
Electrode
(Qty.)
4 6 10 Ident No.
Relais
Télémécanique
(A)
12 to 18 (3) X 40 984 811
Electrode
(Qty.)
4 6
13
21
17
10
25
Ident No.
21
50 Hz S 100D
22
UPA 100C
Applications
-- Domestic and general water supply
-- Irrigation and spray irrigation
-- Lowering ground water levels
-- Fountains
-- Pressure boosting
-- Air-conditioning systems
-- Fire protection
-- Cooling water cycles
Operating Data
Maximal capacities Q up to 15 m3/h Maximal Head H up to 400 m Maximum fluid temperature t 30 °C Motor ratings P Maximum permissible
amount of suspended sand: 50 g/m
up to 7.5 kW
N
3
Pump Type / Design
Multistage centrifugal pump with components made of
stainless steel and additional bearing for eachstage. The stage casings are connected by means of tie bolts on radial pumps, and by means of studs on mixed--flow pumps. Submersible canned motor: Franklin Electric pre-filled motors, corrosion free, NEMA shaft end, 50 Hz
-- Single-phase and three-phase motor type Super Stainless
-- With separate lead
-- Direct starting, max starts per hour: 20
-- Type of enclosure: IP 68
-- Insulation: Class B
Submersible Borehole Pumps
for Well Diameters of
100 mm (4 inches)
Pump Designation
Type series Minimum well diameter (mm) Design status Capacity Q Number of stages
opt
(m3/h)
Certification
Quality management certified to ISO 9001
UPA 100 C –4 6
Product Features
-- Very sturdy design
-- All components made of stainless steel
-- Suitable for installation in narrow deep wells
-- High efficiency
-- Totally enclosed motor
-- Motor designed for maximum pump output
-- Low noise level
-- For vertical or horizontal installation
-- Check valve protected against blocking
-- Pre-filled motor; no risk of contamination of the pumped water
23
UPA 100C
Selection Chart (Ranges on offer) n 2900 rpm
UPA 100C 2
UPA 100C 3
UPA 100C 4
UPA 100C 7
UPA 100C 12
24
UPA 100C
Materials
Component
Pump ...
Diffuser Upper diffuser Lower diffuser Impeller Pump shaft with Nema coupling Suction casing Suction filter Discharge casing Spacer sleeve Hook
Seal ring NBR + AISI 316 Upper bearing bush NBR + AISI 316 Intermediate bearing bush NBR Val ve fac e NBR + AISI 316
Motor ...
Shaft stainless steel AISI 304 SS Bearing housing stainless steel AISI 304 SS Stator case stainless steel AISI 304 SS
C1 (stainless steel)
stainless steel AISI 304
Direction of Rotation of the Pump
Clockwise rotation (when looking at at the drive shaft end).
Drive
Type submersible canned motor Connection NEMA standard Enclosure IP 68 Frequency f 50 Hz Type of current single-phase and three-phase Rated voltage U 1~ 230 V,
3~ 400 V, Rated power P Voltage fluctuations up to +/-- 10 % Frequency of starts up to 20 / h Min. delay before restarting 3 min
A start box withintegrated phase-shiftingcapacitor andthermal protection is included in the scope of supply of single-phase pump sets in PSC design.
N
up to 7.5 kW
Starting Mode
Direct on line.
Temperatures
The UPA 100 Csubmersible boreholepump isdesigned foruse in water with temperatures of up to +30 °C.
Permissible Cable Lengths
U up to 3 % and temperatures up to +30 °C.
Discharge Nozzle
UPA 100C 2 -- 3 -- 4: Rp 1’’ 7--12 Rp2’’
1
/
2
Installation
Vertical or horizontal installation without restriction. In order to guarantee the dissipation of the motor heat it will be necessary to install a device guiding the flow along the motor (cooling jacket, flow inducer sleeve, etc.) in horizontal installation.
Variants Available on Request
-- Higher fluid temperatures
-- Voltages above 500 V
-- Other frequencies
Type of current /
Voltage
1~ 230 V
50 Hz
3~ 400 V
50 Hz
Drive rating
kW 1.5 2.5 4.0 6.0 10.0
0.37
0.55
0.75
1.10
1.50
2.20
0.37
0.55
0.75
1.10
1.50
2.20
3.30
3.70
4.00
5.50
7.50
Length of cable in m for cross-
section in ... mm
72
120 100
79 50 43 32
--
-­614 403 322 218 165 135 124
90 63
190 159 125
80 68 52
--
--
-­645 516 350 265 215 195 143 100
60 47 30 26 20
752 483 368 242 194 131 100
80 74 55 38
2
248 236 186 118 101
77
--
--
--
--
-­525 397 323 295 215 150
--
--
--
--
--
--
--
--
--
--
--
--
--
--
-­597 415
25
Design Features
Optimised operating costs: Check valve, built into the dis-
charge chamber, designed for low loss of head.
Hydraulic profiles are optimized for the attainment of high efficiencies.
UPA 100C
Resistance to corrosion and abra­sion, i.e. the same inherent qualities of stainless steel.
Oversized intermediate bearings located at each pump stage to align the shaft, specially designed to optimize lubrication.
Coupling and flange suitable for motors with pump mount­ing dimensions in accor­dance with NEMA standards.
Reliable in service: Very strong construction: minimum
thickness of stainless sheet steel of 1 mm, 6 spot welding on each vane, special top bearing for every pump.
Friendly service: Great ease of dismantling and as-
sembly. Easy-to-replace wear-rings and
bearings.
26
UPA 100C
aed
aed
UPA 100C 2 -- ...
D1
ØD1max: Pump = 96.5 mm
Pump with motor = 98.0 mm
-- 7 2
-- 6 6
-- 6 0
-- 5 4
-- 4 7
-- 4 0
-- 3 5
-- 3 0
-- 2 1
-- 1 7
-- 1 3
-- 8
UPA 100C 2 -- ...
(Tolerances to ISO 2548 Class C, Annex B)
-- 2 5
-- 6
Rated Rated Rated current for power
P kW
0.37
0.37
0.55
0.75
1.1
1.1
1.5
1.5
2.2
2.2
2.2
3.0
3.0
3.0
power
(Motor)
P
N
HP
0.5
0.5
0.75
1.5
1.5
1~
220 V
N
I
3.2
3.6
5.7
1
6.9
8.0
8.9
2
9.5
2
11. 1
3
12.1
3
14.5
3
15.9 4 4 4
3~
400 V
1)
N
I
0.9
1.1
1.5
2.0
2.8
3.0
3.3
3.8
5.1
5.4
5.6
6.8
7.2
7.5
N
A
Operating range:
=0.5--2.5m3/h
Q
min
= End of characteristic curve
Q
max
A
--
--
--
(Motor)
Pump set
UPA 100C 2 --..
6 8 13 17 21
25 30 35 40 47
54 60 66 72
1)
Capacitor run motors (PSC motors) with starter.
Dimensions / Weights / Ident. Numbers
Pump set
UPA 100C 2 --..
6
8
13
17
21
25
30
35
40
47
54
60
66
72
A mm
349
397
517
623
711
807
928
1048
1169
1338
1506
1651
1796
1941
B mm C mm Ident. No. B mm C mm Ident. No. mA≈ kg
242
242
271
299
327
327
356
356
460
460
460
--
--
--
For horizontal installation, a device guiding the flow along the motor (cooling shroud, flow inducer sleeve, etc.) will be required.
1~ / 220 V 3~ / 400 V
591
639
788
922
1038
1134
1284
1404
1629
1798
1966
--
--
--
90 065 300
90 065 301
90 065 302
90 065 303
90 065 304
90 065 305
90 065 306
90 065 307
90 065 308
90 065 309
90 065 310
--
--
--
223
223
242
271
299
299
327
327
356
356
356
423
423
423
572
620
759
894
1010
1106
1255
1375
1525
1694
1862
2074
2219
2364
90 065 387
90 065 388
90 065 389
90 065 390
90 065 391
90 065 392
90 065 393
90 065 394
90 065 395
90 065 396
90 065 397
90 065 398
90 065 399
90 065 400
11. 1
11.7
14.3
17.0
19.5
20.8
23.7
25.4
28.1
29.5
32.6
37.0
38.9
40.9
Accessories: UPA Control for dry running protection see page 32.
27
UPA 100C 3 -- ...
aed
aed
D1
ØD1max: Pump = 96.5 mm
Pump with motor = 98.0 mm
-- 6 8
-- 6 2
-- 5 7
-- 5 1
-- 4 4
-- 3 6
-- 3 0
-- 2 5
-- 2 2
-- 1 8
-- 1 5
-- 1 2
-- 9
-- 6
UPA 100C
UPA 100C 3 -- ...
(Tolerances to ISO 2548 Class C, Annex B)
Rated Rated power
(Motor)
Pump set
UPA 100C 3 --..
6 9 12 15 18
22 25 30 36 44
51 57 62 68
1)
Capacitor run motors (PSC motors) with starter.
P
kW
0.37
0.55
0.75
1.1
1.1
1.5
1.5
2.2
2.2
3.0
3.0
3.7
3.7
4.0
N
power
(Motor)
P
N
HP
0.5
0.75
1.0
1.5
1.5
2.0
2.0
3.0
3.0
4.00
4.0
5.0
5.0
5.5
Rated current for
1~
220 V
I
N
3.6
5.7
6.9
8.7
8.9
9.8
11. 1
12.5
15.9
3~
400 V
1)
I
A
N
A
1.1
1.5
2.0
2.9
3.0
3.6
3.8
5.2
5.6
--
7.0
--
7.2
--
8.8
--
9.1
--
10.00
Operating range: Q
=1.0--3.5m3/h
min
= End of characteristic curve
Q
max
Dimensions / Weights / Ident. Numbers
Pump set
UPA 100C 3 --..
6
9
12
15
18
22
25
30
36
44
51
57
62
68
A mm
349
421
493
566
638
734
807
928
1072
1265
1434
1579
1699
1844
B mm C mm Ident. No. B mm C mm Ident. No.
242
271
299
327
327
356
356
460
460
--
--
--
--
--
1~ / 220 V 3~ / 400 V
591
692
792
883
965
1090
1163
1388
1532
--
--
--
--
--
90 065 311
90 065 312
90 065 313
90 065 314
90 065 315
90 065 316
90 065 317
90 065 318
90 065 319
mA≈ kg
223
242
271
299
299
327
327
356
--
--
--
--
--
356
423
423
545
545
583
572
663
764
865
937
1061
1134
1284
1428
1688
1857
2124
2244
2427
90 065 401
90 065 402
90 065 403
90 065 404
90 065 405
90 065 406
90 065 407
90 065 408
90 065 409
90 065 410
90 065 411
90 065 412
90 065 413
90 065 414
11. 1
13.1
15.4
17.1
18.5
21.1
22.1
25.1
27.2
32.3
34.7
41.5
43.2
48.3
For horizontal installation, a device guiding the flow along the motor (cooling shroud, flow inducer sleeve, etc.) will be required.
Accessories: UPA Control for dry running protection see page 32.
28
UPA 100C
aed
aed
UPA 100C 4 -- ...
D1
ØD1max: Pump = 96.5 mm
Pump with motor = 98.0 mm
Rated Rated power
(Motor)
Pump set
UPA 100C 4 --..
4 7 9 14 19
24 29 34 39 45
50 54 60 66 72
1)
Capacitor run motors (PSC motors) with starter.
P kW
0.37
0.55
0.75
1.1
1.5
2.2
2.2
3.0
3.0
3.7
3.7
4.0
5.5
5.5
5.5
N
power
(Motor)
P
N
HP
0.5
0.75
1.0
1.5
2.0
3.0
3.0
4.0
4.0
5.0
5.0
5.5
7.5
7.5
7.5
Rated current for
1~
220 V
I
N
A
3.6
5.7
6.9
8.9
11. 1
12.8
15.9
--
--
--
--
--
--
--
--
-- 7 2
UPA 100C 4 -- ...
(Tolerances to ISO 2548
-- 6 6
-- 6 0
-- 5 4
-- 5 0
-- 4 5
-- 3 9
-- 3 4
-- 2 9
-- 2 4
-- 1 9
-- 1 4
-- 9
-- 7
-- 4
3~
400 V
1)
I
N
A
1.1
1.5
2.0
3.0
3.8
5.3
5.6
7.0
7.2
8.8
9.1
10.0
11. 5
12.5
13.2
Operating range:
=1.0--5.0m3/h
Q
min
= End of characteristic curve
Q
max
Class C, Annex B)
Dimensions / Weights / Ident. Numbers
Pump set
UPA 100C 4 --..
4
7
9
14
19
24
29
34
39
45
50
54
60
66
72
A mm
300
373
421
542
662
783
903
1024
1145
1289
1410
1506
1651
1796
1941
B mm C mm Ident. No. B mm C mm Ident. No.
242
271
299
327
356
460
460
--
--
--
--
--
--
--
--
For horizontal installation, a device guiding the flow along the motor (cooling shroud, flow inducer sleeve, etc.) will be required.
Accessories: UPA Control for dry running protection see page 32.
1~ / 220 V 3~ / 400 V
542
644
720
869
1018
1243
1363
--
--
--
--
--
--
--
--
90 065 320
90 065 321
90 065 322
90 065 323
90 065 324
90 065 325
90 065 326
--
--
--
--
--
--
--
--
223
242
271
299
327
356
356
423
423
545
545
583
698
698
698
523
615
692
841
989
1139
1259
1447
1568
1834
1955
2089
2349
2494
2639
90 065 415
90 065 416
90 065 417
90 065 418
90 065 419
90 065 420
90 065 421
90 065 422
90 065 423
90 065 424
90 065 425
90 065 426
90 065 427
90 065 428
90 065 429
mA≈ kg
10.5
12.5
14.5
17.4
20.4
23.5
25.2
29.4
31.1
38.0
39.7
44.3
51.6
53.7
55.7
29
UPA 100C
aed
aed
UPA 100C 7 -- ...
D1
ØD1max: Pump = 96.5 mm
Pump with motor = 98.0 mm
Rated Rated power
(Motor)
Pump set
UPA 100C 7 --..
3 4 6 9 13
16 19 23 26 29
32 34 39 44 49
54 59 64
1)
Capacitor run motors (PSC motors) with starter.
P
kW
0.37
0.55
0.75
1.1
1.5
2.2
2.2
3.0
3.0
3.7
3.7
4.0
5.5
5.5
5.5
7.5
7.5
7.5
N
power
(Motor)
P
N
HP
0.5
0.75
1.0
1.5
2.0
3.0
3.0
4.0
4.0
5.0
5.0
5.5
7.5
7.5
7.5
10.0
10.0
10.0
Rated current for
1~
220 V
I
N
3.6
5.7
6.9
8.9
11. 1
12.8
15.9
3~
400 V
1)
I
A
N
A
1.1
1.5
2.0
3.0
3.8
5.2
5.6
--
6.6
--
7.2
--
8.3
--
9.1
--
10.0
--
11. 5
--
12.5
--
13.2
--
17.5
--
18.3
--
19.1
Operating range: Q
=2.0--8.0m3/h
min
= End of characteristic curve
Q
max
Dimensions / Weights / Ident. Numbers
Pump set
UPA 100C 7 --..
3
4
6
9
13
16
19
23
26
29
32
34
39
44
49
54
59
64
A mm
276
300
349
421
517
590
662
759
831
903
976
1024
1145
1266
1386
1506
1628
1748
B mm C mm Ident. No. B mm C mm Ident. No.
242
271
299
327
356
460
460
--
--
--
--
--
--
--
--
--
--
--
1~ / 220 V 3~ / 400 V
519
571
648
748
873
1050
1122
--
--
--
--
--
--
--
--
--
--
--
90 065 327
90 065 328
90 065 329
90 065 330
90 065 331
90 065 332
90 065 333
UPA 100C 7 -- ...
-- 6 4
-- 5 9
-- 5 4
-- 4 9
-- 4 4
-- 3 9
-- 3 4
-- 3 2
-- 2 9
-- 2 6
-- 2 3
-- 1 9
-- 1 6
-- 1 3
-- 9
-- 6
-- 4
-- 3
223
242
271
299
327
356
--
--
--
--
--
--
--
--
--
--
--
356
423
423
545
545
583
698
698
698
774
774
774
500
542
620
720
844
946
1118
1182
1254
1448
1521
1607
1843
1964
2084
2280
2402
2522
(Tolerances to ISO 2548 Class C, Annex B)
90 065 430
90 065 431
90 065 432
90 065 433
90 065 434
90 065 435
90 065 436
90 065 437
90 065 438
90 065 439
90 065 440
90 065 441
90 065 442
90 065 443
90 065 444
90 065 445
90 065 446
90 065 447
mA≈ kg
10.2
11.5
13.5
15.8
18.5
21.0
22.0
25.9
27.0
33.0
34.0
37.9
45.0
46.8
48.6
53.9
55.7
59.5
For horizontal installation, a device guiding the flow along the motor (cooling shroud, flow inducer sleeve, etc.) will be required. Accessories: UPA Control for dry running protection see page 32.
30
Loading...
+ 80 hidden pages