KSB Compacta UZ14.450D, Compacta UZ11.450D, Compacta UZ11.900D, Compacta UZ10.900D, Compacta UZ12.900D Installation & Operating Manual

...
Sewage Lifting Unit
Compacta UZ, ZF, ZK
UZ - with Amarex N/KRT ZF, ZK - with Sewabloc
From series S-V/1 From series 2013w01
Installation/Operating Manual
Legal information/Copyright
Installation/Operating Manual Compacta UZ, ZF, ZK
Original operating manual
All rights reserved. The contents provided herein must neither be distributed, copied, reproduced, edited or processed for any other purpose, nor otherwise transmitted, published or made available to a third party without the manufacturer's express written consent.
Subject to technical modification without prior notice.
© KSB SE & Co. KGaA, Frankenthal 23/07/2018
Contents
3 of 64
Compacta UZ, ZF, ZK
Contents
Glossary .................................................................................................................................................. 5
1 General.................................................................................................................................................... 6
1.1 Principles ...........................................................................................................................................................6
1.2 Installation of partly completed machinery....................................................................................................6
1.3 Target group.....................................................................................................................................................6
1.4 Other applicable documents............................................................................................................................6
1.5 Symbols .............................................................................................................................................................6
2 Safety...................................................................................................................................................... 7
2.1 Key to safety symbols/markings.......................................................................................................................7
2.2 General..............................................................................................................................................................7
2.3 Intended use .....................................................................................................................................................8
2.4 Personnel qualification and training...............................................................................................................8
2.5 Consequences and risks caused by non-compliance with this manual .........................................................8
2.6 Safety awareness ..............................................................................................................................................8
2.7 Safety instructions for the operator/user........................................................................................................9
2.8 Safety information for maintenance, inspection and installation ................................................................9
2.9 Unauthorised modes of operation..................................................................................................................9
3 Transport/Temporary Storage/Disposal............................................................................................. 10
3.1 Checking the condition upon delivery..........................................................................................................10
3.2 Transport.........................................................................................................................................................10
3.3 Storage/preservation......................................................................................................................................12
3.4 Return to supplier...........................................................................................................................................13
3.5 Disposal ...........................................................................................................................................................13
4 Description............................................................................................................................................ 14
4.1 General description ........................................................................................................................................14
4.2 Designation.....................................................................................................................................................14
4.3 Name plates ....................................................................................................................................................15
4.4 Design details..................................................................................................................................................15
4.5 Configuration and function...........................................................................................................................16
4.6 Technical data of the control unit.................................................................................................................18
4.6.1 Electrical data.....................................................................................................................................18
4.6.2 Technical specifications for sensors ..................................................................................................18
4.7 Fluids handled.................................................................................................................................................19
4.8 Collecting tank................................................................................................................................................19
4.9 Noise characteristics .......................................................................................................................................20
4.10 Scope of supply...............................................................................................................................................20
4.11 Dimensions and weights ................................................................................................................................20
5 Installation at Site................................................................................................................................ 21
5.1 Safety regulations...........................................................................................................................................21
5.2 Checks to be carried out prior to installation...............................................................................................21
5.3 Installing the lifting unit................................................................................................................................22
5.3.1 Setting up the tank(s)........................................................................................................................22
5.3.2 Setting up the pump..........................................................................................................................22
5.4 Connecting the piping ...................................................................................................................................23
5.5 Cellar drainage ...............................................................................................................................................24
5.6 Connection to power supply..........................................................................................................................25
5.7 Checking the direction of rotation................................................................................................................26
6 Commissioning/Start-up/Shutdown................................................................................................... 27
6.1 Commissioning/Start-up.................................................................................................................................27
6.1.1 Prerequisites for commissioning/start-up .........................................................................................27
6.2 Operating limits..............................................................................................................................................27
Contents
4 of 64
Compacta UZ, ZF, ZK
6.2.1 Operating limits per operating mode ..............................................................................................27
6.2.2 Supply voltage....................................................................................................................................28
6.3 Commissioning/start-up of control unit........................................................................................................28
6.3.1 Lifting unit with LevelControl Basic 2...............................................................................................29
6.4 Shutdown........................................................................................................................................................30
7 Operation.............................................................................................................................................. 32
7.1 Control panel..................................................................................................................................................32
7.1.1 Indicators............................................................................................................................................32
7.1.2 Display ................................................................................................................................................33
7.1.3 Navigation keys..................................................................................................................................33
7.2 Manual-0-automatic selector switch .............................................................................................................34
7.3 Control panel..................................................................................................................................................34
7.3.1 Displaying measured value parameters............................................................................................34
7.3.2 Setting parameters ............................................................................................................................35
7.3.3 Acknowledging alerts and warnings ................................................................................................36
7.3.4 Displaying the alerts list ....................................................................................................................37
7.3.5 Replacing the rechargeable battery .................................................................................................37
8 Servicing/Maintenance........................................................................................................................ 38
8.1 General information/Safety regulations .......................................................................................................38
8.2 Servicing/inspection........................................................................................................................................38
8.2.1 Inspection contract ...........................................................................................................................39
8.2.2 Measuring the insulation resistance of the motor ..........................................................................39
8.2.3 Oil check/Oil change ..........................................................................................................................39
8.2.4 Emergency operation with one pump..............................................................................................39
8.3 Dismantling the pump ...................................................................................................................................40
8.4 Reassembly......................................................................................................................................................40
8.4.1 General instructions...........................................................................................................................40
8.4.2 Pump reassembly ...............................................................................................................................41
8.5 Tightening torques.........................................................................................................................................41
8.6 Disposal/recycling of the lifting unit .............................................................................................................41
8.7 Checklist for commissioning/inspection and maintenance ..................................................................41
9 Trouble-shooting.................................................................................................................................. 43
10 Related Documents.............................................................................................................................. 45
10.1 General assembly drawing/exploded view and list of components............................................................45
10.1.1 General assembly drawing of the lifting unit ..................................................................................45
10.1.2 Exploded view of collecting tank......................................................................................................47
10.2 Connection examples .....................................................................................................................................48
10.2.1 Compacta UZ10.450 - UZ15.450 ........................................................................................................48
10.2.2 Compacta UZ10.900 - UZ15.900 ........................................................................................................49
10.2.3 Compacta UZ20.450 - ZK56.450 ........................................................................................................50
10.2.4 Compacta UZ20.900 - ZK56.900 ........................................................................................................50
10.3 Dimensions......................................................................................................................................................52
10.4 Wiring diagrams .............................................................................................................................................53
10.4.1 LevelControl Basic 2 Type BC - dual-pump unit - DOL starting - up to 4kW - with motor
protection switch - for Compacta UZ................................................................................................53
10.4.2 LevelControl Basic 2 Type BS - dual-pump unit - DOL starting - 5.5kW and above - with motor
protection switch - for Compacta UZ................................................................................................54
10.4.3 LevelControl Basic 2 Type BS - dual-pump unit - star/delta starting - 5.5kW and above - with
motor protection switch - for Compacta UZ ....................................................................................55
10.4.4 LevelControl Basic 2 Type BS - for Compacta ZF and Compacta ZK................................................56
11 EU Declaration of Conformity............................................................................................................. 57
12 Declaration of Performance as per Regulation (EU) No. 305/2011, Annex III.................................. 58
13 Certificate of Decontamination........................................................................................................... 59
Index ..................................................................................................................................................... 60
Glossary
5 of 64
Compacta UZ, ZF, ZK
Glossary
Certificate of decontamination
A certificate of decontamination is enclosed by the customer when returning the product to the manufacturer to certify that the product has been properly drained to eliminate any environmental and health hazards arising from components in contact with the fluid handled.
DIN1986-3 and -30
German standard which stipulates technical rules for the operation, maintenance and servicing of drainage systems in buildings and on premises
Discharge line
Pipe for transporting waste water to a level above the flood level into the sewer system
DOL starting
For low power ratings (usually up to 4kW), the three-phase motor is connected directly to the mains voltage.
Effective volume
Volume in the collection tank between start and stop level that can be lifted
EN 12 056-4
European standard governing the selection, operation and maintenance of sewage lifting units within buildings and sites.
Flood level
Maximum backflow level of waste water in a drainage system
Inlet line
Pipe used for draining waste water from sanitary installations into the lifting unit
Nominal diameter DN
Identifier (inside diameter) used for characterising mating components such as pipes, pipe connections and fittings
Separator
Device for physically separating the two phases of a two-phase flow, e.g. for separating solid particles or liquid drops from flowing gases.
Sewage lifting unit
Device for collecting and automatically lifting waste water with or without faeces above the flood level
Stormwater
Water from natural precipitation which has not been contaminated by any form of use
Vent line
Pipe provided to limit pressure fluctuations within the sewage lifting unit. The vent line is led through the roof.
Waste water
Water which has been changed by some type of use, e.g. domestic waste water
Working space
The space required for performing work on the unit
1 General
6 of 64
Compacta UZ, ZF, ZK
1 General
1.1 Principles
This operating manual is valid for the type series and variants indicated on the front cover.
The manual describes the proper and safe use of this equipment in all phases of operation.
The name plate indicates the type series, the main operating data and the serial number. The serial number uniquely describes the product and is used as identification in all further business processes.
In the event of damage, immediately contact your nearest KSB Service centre to maintain the right to claim under warranty.
1.2 Installation of partly completed machinery
To install partly completed machinery supplied by KSB refer to the sub-sections under Servicing/Maintenance.
1.3 Target group
This operating manual is aimed at the target group of trained and qualified specialist technical personnel.
1.4 Other applicable documents
Table1: Overview of other applicable documents
Document Contents
Sub-supplier product literature Operating manuals and other product literature
of accessories and integrated machinery components, operating manual of waste water pump
1.5 Symbols
Table2: Symbols used in this manual
Symbol Description
Conditions which need to be fulfilled before proceeding with the
step-by-step instructions
Safety instructions
Result of an action
Cross-references
1.
2.
Step-by-step instructions
Note Recommendations and important information on how to handle the product
2 Safety
7 of 64
Compacta UZ, ZF, ZK
2 Safety
!
DANGER
All the information contained in this section refers to hazardous situations. In addition to the present general safety information the action-related safety
information given in the other sections must be observed.
2.1 Key to safety symbols/markings
Table3: Definition of safety symbols/markings
Symbol Description
!
DANGER
DANGER This signal word indicates a high-risk hazard which, if not avoided, will result in death or serious injury.
!
WARNING
WARNING This signal word indicates a medium-risk hazard which, if not avoided, could result in death or serious injury.
CAUTION
CAUTION This signal word indicates a hazard which, if not avoided, could result in damage to the machine and its functions.
Explosion protection This symbol identifies information about avoiding explosions in potentially explosive atmospheres in accordance with EU Directive 2014/34/EU (ATEX).
General hazard In conjunction with one of the signal words this symbol indicates a hazard which will or could result in death or serious injury.
Electrical hazard In conjunction with one of the signal words this symbol indicates a hazard involving electrical voltage and identifies information about protection against electrical voltage.
Machine damage In conjunction with the signal word CAUTION this symbol indicates a hazard for the machine and its functions.
2.2 General
This operating manual contains general installation, operating and maintenance instructions that must be observed to ensure safe operation of the system and prevent personal injury and damage to property.
The safety information in all sections of this manual must be complied with. The operating manual must be read and understood by the responsible specialist
personnel/operators prior to installation and commissioning. The contents of this operating manual must be available to the specialist personnel
at the site at all times. Information attached directly to the product must always be complied with and kept
in a perfectly legible condition at all times. This applies to, for example:
Arrow indicating the direction of rotationMarkings for connectionsName plate
The operator is responsible for ensuring compliance with all local regulations not taken into account in this operating manual.
2 Safety
8 of 64
Compacta UZ, ZF, ZK
2.3 Intended use
The lifting unit must not be used in potentially explosive atmospheres.The lifting unit must only be operated within the operating limits described in
the other applicable documents.
Only operate lifting units which are in perfect technical condition.Do not operate partially assembled lifting units.Only use the lifting unit to handle the fluids described in the product literature
of the respective design variant.
Never operate the lifting unit without the fluid to be handledObserve the minimum flow rates indicated in the data sheet or product literature
(to prevent overheating, bearing damage, etc).
Observe the minimum flow rate and maximum flow rate indicated in the data
sheet or product literature (to prevent overheating, mechanical seal damage, cavitation damage, bearing damage, etc).
Do not throttle the flow rate on the inlet side of the lifting unit (to prevent
cavitation damage)
Consult the manufacturer about any use or mode of operation not described in
the data sheet or product literature.
Never exceed the permissible application and operating limits specified in the
data sheet or product literature regarding pressure, temperature, etc.
Observe all safety information and instructions in this manual.
2.4 Personnel qualification and training
All personnel involved must be fully qualified to install, operate, maintain and inspect the equipment this manual refers to.
The responsibilities, competence and supervision of all personnel involved in installation, operation, maintenance and inspection must be clearly defined by the operator.
Deficits in knowledge must be rectified by means of training and instruction provided by sufficiently trained specialist personnel. If required, the operator can commission the manufacturer/supplier to train the personnel.
Training on the lifting unit must always be supervised by technical specialist personnel.
2.5 Consequences and risks caused by non-compliance with this manual
Non-compliance with these operating instructions will lead to forfeiture of
warranty cover and of any and all rights to claims for damages.
Non-compliance can, for example, have the following consequences:
– Hazards to persons due to electrical, thermal, mechanical and chemical
effects and explosions – Failure of important product functions – Failure of prescribed maintenance and servicing practices – Hazard to the environment due to leakage of hazardous substances
2.6 Safety awareness
In addition to the safety information contained in this manual and the intended use, the following safety regulations shall be complied with:
Accident prevention, health regulations and safety regulationsExplosion protection regulationsSafety regulations for handling hazardous substancesApplicable standards, directives and laws
2 Safety
9 of 64
Compacta UZ, ZF, ZK
2.7 Safety instructions for the operator/user
Fit protective equipment (e.g. contact guards) supplied by the operator for hot,
cold or moving parts, and check that the equipment functions properly.
Do not remove any protective equipment (e.g. contact guards) during operation.Provide the personnel with protective equipment and make sure it is used.Contain leakages (e.g. at the shaft seal) of hazardous fluids handled (e.g.
explosive, toxic, hot) so as to avoid any danger to persons and the environment. Adhere to all relevant laws.
Eliminate all electrical hazards. (In this respect refer to the applicable national
safety regulations and/or regulations issued by the local energy supply companies.)
2.8 Safety information for maintenance, inspection and installation
Modifications or alterations of the lifting unit require the manufacturer's prior
consent.
Use only original spare parts or parts authorised by the manufacturer. The use of
other parts can invalidate any liability of the manufacturer for resulting damage.
The operator ensures that maintenance, inspection and installation is performed
by authorised, qualified specialist personnel who are thoroughly familiar with the manual.
Carry out work on the lifting unit during standstill only.The pump casing must have cooled down to ambient temperature.Pump pressure must have been released and the pump must have been drained.When taking the lifting unit out of service always adhere to the procedure
described in the manual.
Decontaminate lifting units which handle fluids posing a health hazard.
(ðSection8.1,Page38)
As soon as the work has been completed, re-install and re-activate any safety-
relevant devices and protective devices. Before returning the product to service, observe all instructions on commissioning.
Make sure the lifting unit cannot be accessed by unauthorised persons (e.g.
children).
2.9 Unauthorised modes of operation
Always observe the limits stated in the product literature. The warranty relating to the operating reliability and safety of the lifting unit
supplied is only valid if the equipment is used in accordance with its intended use. (ðSection2.3,Page8)
3 Transport/Temporary Storage/Disposal
10 of 64
Compacta UZ, ZF, ZK
3 Transport/Temporary Storage/Disposal
3.1 Checking the condition upon delivery
1. On transfer of goods, check each packaging unit for damage.
2. In the event of in-transit damage, assess the exact damage, document it and notify KSB or the supplying dealer and the insurer about the damage in writing immediately.
3.2 Transport
DANGER
Lifting unit falling off the pallet
Risk of injury from falling lifting unit!
Always transport the lifting unit in a horizontal position.Give due attention to the weight data, centre of gravity and fastening points.Never suspend the lifting unit by its power cable.Use suitable and permitted transport equipment, e.g. crane, forklift or pallet
truck.
Table4: Weight Compacta UZ - Amarex N/KRT [kg]
Sizes Weight
Per pump Lifting unit
1)
UZ10.450D UZ10.900D
85 85
305 380
UZ11.450D UZ11.900D
87 87
315 390
UZ12.450D UZ12.900D
142 142
400 485
UZ13.450D UZ13.900D
153 153
420 505
UZ14.450D UZ14.900D
180 180
470 555
UZ15.450D UZ15.900D
180 180
470 555
UZ20.450D UZ20.900D
165 165
465 540
UZ21.450D UZ21.900D
175 175
485 560
UZ22.450D UZ22.900D
213 213
561 646
UZ23.450D UZ23.900D
213 213
564 646
UZ24.450D UZ24.900D
213 213
561 646
UZ25.450D UZ25.900D
213 213
561 646
UZ26.450D UZ26.900D
213 213
561 646
UZ27.450D UZ27.900D
180 180
495 570
1) Weight of the lifting unit without water fill
3 Transport/Temporary Storage/Disposal
11 of 64
Compacta UZ, ZF, ZK
Sizes Weight
Per pump Lifting unit
1)
UZ28.450D UZ28.900D
180 180
495 570
UZ29.450D UZ29.900D
180 180
495 570
Table5: Weight Compacta ZF - Sewabloc [kg]
Sizes Weight
Per pump Lifting unit
2)
ZF30.450D ZF30.900D
195 195
525 600
ZF31.450D ZF31.900D
204 204
543 618
ZF32.450D ZF32.900D
204 204
543 618
ZF33.450D ZF33.900D
275 275
695 770
ZF34.450D ZF34.900D
335 335
695 770
ZF35.450D ZF35.900D
335 335
695 770
ZF36.450D ZF36.900D
335 335
695 770
ZF40.450D ZF40.900D
117 117
369 444
ZF41.450D ZF41.900D
121 121
377 452
ZF42.450D ZF42.900D
134 134
403 478
ZF43.450D ZF43.900D
141 141
417 492
ZF44.450D ZF44.900D
141 141
417 492
ZF45.450D ZF45.900D
170 170
475 550
ZF46.450D ZF46.900D
182 182
499 574
ZF47.450D ZF47.900D
121 121
377 452
ZF48.450D ZF48.900D
130 130
395 470
ZF49.450D ZF49.900D
135 135
405 480
Table6: Weight Compacta ZK - Sewabloc [kg]
Sizes Weight
Per pump Lifting unit
3)
ZK50.450D ZK50.900D
128 128
391 466
ZK51.450D ZK51.900D
128 128
391 466
2) Weight of the lifting unit without water fill
3) Weight of the lifting unit without water fill
3 Transport/Temporary Storage/Disposal
12 of 64
Compacta UZ, ZF, ZK
Sizes Weight
Per pump Lifting unit
3)
ZK52.450D ZK52.900D
135 135
405 480
ZK53.450D ZK53.900D
135 135
405 480
ZK54.450D ZK54.900D
135 135
405 480
ZK55.450D ZK55.900D
141 141
417 492
ZK56.450D ZK56.900D
141 141
417 492
ü The lifting unit has been checked for in-transit damage.
1. Select suitable transport equipment (in acc. with weights table).
2. Transport the tank/pump to the place of installation.
3. Remove the transport fixtures.
4. Use suitable lifting equipment to place the tank/pump down at the place of installation (as shown).
Fig.1: Transporting the tank - Amarex/KRT - Sewabloc
3.3 Storage/preservation
If commissioning is to take place some time after delivery, we recommend that the following measures be taken for storing the lifting unit:
CAUTION
Damage during storage due to frost, humidity, dirt, UV radiation or vermin
Corrosion/contamination of the lifting unit!
Store the lifting unit in a frost-proof, roofed area.
CAUTION
Wet, contaminated or damaged openings and connections
Leakage or damage of the lifting unit!
Only open the openings of the lifting unit at the time of installation.
Store the lifting unit in a dry, protected room where the atmospheric humidity is as constant as possible.
3 Transport/Temporary Storage/Disposal
13 of 64
Compacta UZ, ZF, ZK
3.4 Return to supplier
1. Drain the lifting unit as described in the manual.
2. Always flush and clean the lifting unit, particularly if it has been used for handling noxious, explosive, hot or other hazardous fluids.
3. If the unit has handled fluids whose residues could lead to corrosion damage in the presence of atmospheric humidity or could ignite upon contact with oxygen, the unit must also be neutralised and blown through with anhydrous inert gas to ensure drying.
4. Always complete and enclose a certificate of decontamination when returning the lifting unit. (ðSection13,Page59) Always indicate any safety and decontamination measures taken.
NOTE
If required, a blank certificate of decontamination can be downloaded from the following web site: www.ksb.com/certificate_of_decontamination
3.5 Disposal
WARNING
Fluids handled, consumables and supplies which are hot and/or pose a health hazard
Hazard to persons and the environment!
Collect and properly dispose of flushing fluid and any fluid residues.Wear safety clothing and a protective mask if required.Observe all legal regulations on the disposal of fluids posing a health hazard.
1. Dismantle the lifting unit. Collect greases and other lubricants during dismantling.
2. Separate and sort the pump materials, e.g. by:
- Metals
- Plastics
- Electronic waste
- Greases and other lubricants
3. Dispose of materials in accordance with local regulations or in another controlled manner.
4 Description
14 of 64
Compacta UZ, ZF, ZK
4 Description
4.1 General description
Floodable sewage lifting unit
The sewage lifting unit consists of either one or two collecting tanks, two pump
sets and the unit control system.
NOTE
The flow velocity in the discharge line must not be less than 0.7m/s and not higher than 2.3 m/s.
NOTE
The effective volume of the lifting unit must be greater than the volumetric content of the discharge line up to the backflow loop.
4.2 Designation
Example: Compacta UZ X 12.450 D
Table7: Designation key
Code Description
Compacta Type series UZ Type of lifting unit
U Floodable AmarexKRT submersible motor pump,
Fimpeller Z Dual-pump unit F Dry-installed Sewabloc volute casing pump,
Fimpeller K Dry-installed Sewabloc volute casing pump,
Kimpeller
X Special design 12 Hydraulics code 450 Total volume of collecting tank [litres]
450, 900
D Three-phase motor
Control unit
Example: BC 2 400 D V N A 100 B 2
Table8: Designation key
Code Description
BC Type
BC Basic Compact
2 Number of pumps 400 Electrical voltage, e.g. 400V, resulting in the number of
wires (e.g. 400V, 4wires or 5wires)
D Starting method
D DOL starting
V Sensor 0-5V N Without ATEX function A Installation option with rechargeable battery 100 Rated current x 10 (e.g. 10A)
4 Description
15 of 64
Compacta UZ, ZF, ZK
Code Description
B Pump variant 2 Country-specific version
4.3 Name plates
Examples:
Pump For the pump name plate refer to the installation/operating manual of the waste
water pump.
Tank
1
2
3
4
5
6
7 8
Johann-Klein-Straße 9
Deutschland
67227 Frankenthal
KSB SE & Co. KGaA
1 Type series, size 2 Serial No. 3 Maximum flow rate 4 Maximum head 5 Principles of construction and
testing
6 Year/week of construction
7 Notified body / year of
introduction
8 Declaration of performance
reference No.
Control unit
1
2
3
4
5
6
7
ZNI 1448xa
2014w07
BD706005
BC2400DFNO100
IP 54
Made in Germany
Ue: 3/N/PE/AC 400 V 50 HZ
Ie: 6,3 - 10,0 A
LevelControl Basic 2
Johann-Klein-Straße 9
Deutschland
67227 Frankenthal
KSB SE & Co. KGaA
Fig.2: Example of name plate
1 Designation 2 Product code 3 Nominal voltage 4 Nominal current 5 Circuit diagram number 6 Year/week of construction 7 Enclosure
4.4 Design details
Lifting unit
Design
Sewage lifting unit to EN12050-1Ready-to-connect dual-pump stationGas and water-proof plastic collecting tank, sensors and control unit
– UZ, ZF, ZK900 battery design with two collecting tanks
Compacta UZ:
Floodable sewage lifting unit
4)
Two vertically installed submersible waste water pumps
4) Max. flooding height: 2 metres, max. flooding period: 7 days (does not apply to control unit). The lifting unit must be cleaned and serviced after it has been flooded.
4 Description
16 of 64
Compacta UZ, ZF, ZK
Compacta ZF, ZK:
Two dry-installed vertical waste water volute casing pumps
Drive
Surface-cooledThree-phase motorThermal class FElectrical voltage 400V (three-phase motor)Frequency 50 HzDOL starting (from 5.5kW star-delta starting)
Compacta UZ:
Submersible motor made by KSB, IP68 enclosureMonitoring by temperature switches in the winding
Compacta ZF, ZK:
Standardised motor made by KSB, IP55 enclosureMonitoring via three PTC thermistors
Impeller type
Free-flow impellerVarious application-oriented impeller types
Bearings
Grease-packed, maintenance-free rolling element bearings
Shaft seal
Two bi-directional mechanical seals with oil reservoir filled with environmentally
friendly oil
4.5 Configuration and function
1
3
7
8
2
4
6
5
Fig.3: Compacta
1 Inlet 2 Level sensor 3 Transport and
float protection
4 Pump
5 Vent connection 6 Hand hole cover 7 Tank 8 Discharge line
4 Description
17 of 64
Compacta UZ, ZF, ZK
Design The lifting unit is provided with several horizontal inlet nozzles(1). The pump(4)
pumps the fluid handled into the vertical discharge line(8).
Function The fluid to be handled flows into the lifting unit through horizontal inlet nozzles(1)
and is collected in a gas-, odour- and water-tight plastic tank(7). When the level sensor detects a defined fill level, the fluid is automatically pumped off to a level above the flood level and towards the public sewer by either one or two pumps(4).
Sealing Two bi-directional mechanical seals supplied with environmentally-friendly oil.
Control unit
DANGER
Flooding of control unit
Danger of death from electric shock!
Operate the control unit in flood-proof rooms only.
LevelControl Basic 2 Type BasicCompact (BC)
Pump control and monitoring unit in compact plastic housingFor either one or two pumpsWith displayLevel detection via:
– Level sensor 0-5V
DOL starting
2
3
1
Fig.4: Type Basic Compact (BC)
1 Control panel 2 Master switch (optional) 3 Manual-0-automatic switch
LevelControl Basic 2 Type Basic Control Cabinet (BS)
Pump control and monitoring unit in sheet steel housingFor either one or two pumpsWith displayLevel detection via:
– Level sensor 0-5V
DOL starting or star/delta starting
4 Description
18 of 64
Compacta UZ, ZF, ZK
1
2
3
Fig.5: Type Basic Control Cabinet (BS)
1 Master switch 2 Control panel 3 Manual-0-automatic switch
NOTE
The control units are not explosion-proof, and therefore must only be operated outside potentially explosive atmospheres.
The control unit is always located outside the potentially explosive atmosphere and may only be installed in a flood-proof room.
4.6 Technical data of the control unit
4.6.1 Electrical data
NOTE
The rated current must not be exceeded. Higher currents and power ratings are available on request.
Table9: Electrical data of the LevelControl Basic 2 control unit
Characteristic Value
Rated operating voltage 3 ~ 400 V AC +10 % -15 % Mains frequency 50 Hz ± 2% Enclosure 400V: IP54 Rated insulation voltage 500V AC Rated current per motor
(standard models)
Type BS:
1.6A / 2.5A / 4A / 6.3A / 10A / 14A / 18A / 23A / 25A / 40A / 63A
4.6.2 Technical specifications for sensors
Analog level sensor
Input voltage 0-5V
Motor protection sensors
Max. 2 bimetal switches (thermal circuit breaker) for each pump, 24V, motor
monitoring, PTC data analysis for Compacta ZF, ZK
Max. 1 moisture monitor for each Amarex N/KRT pump
Process inputs
1 x external alarm input, 24V, via volt-free contact1 x remote acknowledgement, 24V, via volt-free contact
4 Description
19 of 64
Compacta UZ, ZF, ZK
Process outputs
1 x volt-free signalling output (250V, 1A, changeover contact)1 x signalling output (12.6 to 13.2V), e.g. for connecting a horn, alarm
combination or alarm strobe light (12V connection)
Rechargeable battery
Connection for rechargeable battery, for mains-independent power supply of:
ElectronicsSensorsAlarm equipment
Battery life/charging time
Battery life:
Approx. 10 hours when supplying the integrated piezo buzzer 85dB(A),
electronics, and sensors
Approx. 4 hours when supplying external alarm equipment (e.g. horn, alarm
combination, or alarm strobe light)
Charging time
Approx. 11 hours (if battery is fully discharged)
4.7 Fluids handled
WARNING
Pumping of impermissible fluids
Hazardous to persons and the environment!
Only discharge permissible fluids into the public sewer system.Check the suitability of pump/system materials.
Permissible
fluids
According to DIN1986-3 the following fluids can be discharged into sewer systems: Water contaminated by domestic use, human and - as far as required and permitted ­animal faeces together with the necessary flushing water as well as stormwater in
case no other way of disposal is possible.
5)
Impermissible
fluids
Substances / water which must not be discharged into the sewer system are, amongst others:
Solid matter, fibres, tar, sand, cement, ash, coarse paper, paper towels, cardboard, debris, garbage, offal, grease, oil.
Waste water from installations situated above the flood level (EN12056-1). Waste water containing hazardous substances (DIN1986-100), e.g. greasy waste
water from large-scale catering kitchens. For drainage of greasy water a grease separator to DIN4040-1 must be fitted.
4.8 Collecting tank
The collecting tank is designed for unpressurised operation; that means the waste water is stored in the tank in unpressurised condition and is then pumped into the sewer system.
Size Total volume
Effective volume
Litres Litres
UZ450 450 290 UZ900 900 580
5) Other types of waste water, e.g. industrial waste water, must not be discharged into the local sewer system without prior treatment.
4 Description
20 of 64
Compacta UZ, ZF, ZK
4.9 Noise characteristics
The sound pressure level depends on the local conditions and the duty point. It is ≤70dB(A).
4.10 Scope of supply
Depending on the model, the following items are included in the scope of supply: Sewage lifting unit consisting of:
Either one or two gas-, odour- and water-tight collecting tanks made of impact-
resistant plastic material, with two waste water pumps
Flexible hose connections and hose clipsAutomatic level transmitterElectronic control unit
4.11 Dimensions and weights
available For dimensions and weights please refer to the outline drawing of the lifting unit.
Control unit Table10: Dimensions and weights
LevelControl Maximum current Size
H × B × T
[kg]
[A] [mm]
Basic 1 10 135 × 171 × 107 3 Basic 2 BC 10 400 × 281 × 135 3 Basic 2 BS1 10 400 × 300 × 155 10
14 600 × 400 × 200 14 18 600 × 400 × 200 14 23 600 × 400 × 200 14 25 600 × 400 × 200 14 40 800 × 600 × 200 18 63 800 × 600 × 200 18
Basic 2 BS2 10 400 × 300 × 155 16
14 800 × 600 × 200 19 18 800 × 600 × 200 19 23 800 × 600 × 200 19 25 800 × 600 × 200 19 40 800 × 600 × 200 24 63 800 × 600 × 200 26