KRUSMAN 7023 Instructions For Installation, Use And Maintenance Manual

Instructions for Installation, Use and Maintenance
KRUSMAN- Portable Tank Shower Systems
(EN-15154-3:2009, EN-15154-4:2009 and ANSI Norm Z358.1-2009)
(Product displayed is for illustration purposes only and may differ slightly)
Series: Portable Safety Tank Showers Article Number: 7023
1
Table of contents
General Caution ....................................................................................................................................... 3
Accessories / Options for Safety Showers ............................................................................................... 3
Guarantee ................................................................................................................................................ 3
Safety ....................................................................................................................................................... 3
Hazards Resulting from Non-observance of Safety Precautions ............................................................. 4
Safety Precautions for the Operating Company.................................................................................. 4
Safety Precautions for Use, Maintenance, Inspection and Installation Work .................................... 4
Impermissible Modes of Operation .................................................................................................... 4
Range of Applications ...................................................................................................................... 5
Storage and Transport ............................................................................................................................. 5
Dimensions of the trailer ..................................................................................................................... 5
Installation ............................................................................................................................................... 6
Requirements for the Installation Site ................................................................................................ 6
Proximity Switch connection ............................................................................................................... 7
Filling ................................................................................................................................................... 8
Initial Start-up ...................................................................................................................................... 8
Use ........................................................................................................................................................... 9
Body Showers with pull rod ................................................................................................................ 9
Models with Optional Eye Shower ...................................................................................................... 9
Models with Optional Heater .............................................................................................................. 9
Inspections / Malfunctions ................................................................................................................ 10
Weekly Inspection or after installation on site ............................................................................. 10
Semi-Annual Inspection ................................................................................................................. 10
Annual Inspection .......................................................................................................................... 10
Water Quality ................................................................................................................................ 10
Malfunctions / Trouble shooting ....................................................................................................... 11
Disposal ............................................................................................................................................. 11
Replacement Parts and Accessories .................................................................................................. 11
EC Declaration of Conformity ............................................................................................................ 11
Certificate of conformity for water bowsers ..................................................................................... 11
Letter of conformity .............................................................................................................................. 12
2
General Caution
The requirements set forth in all applicable legal requirements through May 2004 are taken into account in these instructions for use. In the event that any applicable laws are changed, we shall not update these instructions for use unless commissioned to do so. These instructions for use do not replace the legally required work directive which must be prepared by the operating company for the safety shower.
Accessories / Options for Safety Showers
Safety shower systems can be ordered with options (accessories). If any of the below listed options have been ordered, please refer to separately furnished, supplementary instructions for installation, use and maintenance.
Switch for emergency alarm Alarm light/horn Immersion bath heater Chiller unit Anti-bacterial additive solution
Guarantee
Our liability for defective equipment is specified in our terms and conditions of delivery. We assume no liability for damages resulting from non-observance of the instructions for use and maintenance, or from non-observance of the specified conditions of use. Only products which are free of defects, and which demonstrate the characteristics specified by ourselves, are permitted to leave our factory. Proper functioning is thus assured if the instructions for use and maintenance are carefully observed.
Safety
These instructions for use and maintenance contain essential information which must be observed during use, maintenance and repair. These instructions for use and maintenance must therefore be read by trained personnel before the safety shower is placed into service, and a work directive must be prepared by the operating company which makes reference to these instructions for use, as well as local and company specific circumstances, and trained personnel must be accordingly instructed before working on or with the safety shower.
The safety precautions included in these instructions for use, non-observance of which may be hazardous for human beings and the environment, are identified with the general warning symbol in accordance with accident prevention regulation BGV A 8:
3
Or with the following symbol for warnings regarding electrical voltage.
The word is added to safety precautions whose non-observance may be hazardous for the respective technical equipment and its functions.
It is absolutely essential to observe all instructions which are attached directly to the safety shower systems, and to keep them in a readily and legible condition.
Hazards Resulting from Non-observance of Safety Precautions
Non-observance of safety precautions may be hazardous to human beings, as well as the respective technical equipment. Non-observance of safety precautions may render the guarantee null and void, and may bar any possible claims for damage.
All safety precautions listed in these instructions for use and maintenance, all applicable legal regulations and accident prevention regulations, and the work directive and safety precautions issued by the operating company must be observed.
Safety Precautions for the Operating Company
Technical safety equipment must be kept in an operationally reliable condition. The functional reliability of the power supply for the frost guard may not be impaired. Safety shower systems must be installed such that the user has direct access to the shower.
Safety Precautions for Use, Maintenance, Inspection and Installation Work
The operating company must assure that all maintenance and installation work is executed
by authorised, qualified, trained personnel.
Work may only be performed on the electrical system (if included) by trained electricians
after it has been disconnected from all sources of electrical power – see also the applicable accident prevention regulation, VDE regulations and regulations issued by your local power utility (only applies to safety shower systems equipped with electrical accessories).
When locating the unit consider there are no other dangerous risks around the object. When
the system is being operated a lot of water is released from the shower and eye wash, which can be hazardous if located near certain things like electricity etc...
Impermissible Modes of Operation
The technical safety equipment integrated into KRUSMAN safety shower systems, e.g. heater, alarm switch, illumination, actuating mechanism etc., must always be kept in good working order. It is impermissible for the operating company to neglect any of its respective legal responsibilities, for example:
Non-issuance of the required work directive and/or Neglecting to prepare a hazard analysis and/or Non-observance of specified maintenance work, inspection work and periodic testing and/or
4