Krown Manufacturing KBS300RX User Manual

INSTRUCTION MANUAL
KA300TX / KA300RX / KBS300RX
Alarm Monitor
KA300TX / KA300RX / KBS300RX
Alarm Monitor
PATENT PENDING
Important
Warranty
Compu-TTY, Inc. warrants that the Alarm Monitor sold by Compu-TTY, Inc. is free from defects in materials and workmanship under normal use and service for one year. This warranty is applicable only to the original purchaser of the Alarm Monitor when accom­panied by a sale receipt stating the date of purchase and the name of the company from which purchased. This warranty is in lieu and excludes all other warranties, expressed or implied, including any implied warranty of merchantability or fitness and of any obliga­tion on the part of Compu-TTY, Inc. If the Alarm Monitor shall prove the defective, then Compu-TTY, Inc shall either replace or repair the Alarm Monitor at no cost to the origi­nal purchaser within one year of the date of purchase. During the one-year period you may return the Alarm Monitor to Compu-TTY, Inc. at the following address:
Compu-TTY Inc.
3408 Indale Rd. Fort Worth, TX 76116
This warranty does not apply to the alarm monitor if it has been damaged, modified, abused or altered after the date of purchase or if it fails to operate due improper mainte­nance or inadequate AC or DC power.
In no event, shall Compu-TTY, Inc. be liable for loss of use of this product or for any indi­rect, special, incidental, or consequential damages, personal injury, property damage, or cost, or expenses incurred by the consumer or any other user of this products. This war­ranty is only applicable to a product purchased through Krown Manufacturing, Compu­TTY, or a Krown dealer. Other than state herein, there is no other warranty whether by the sample or model, by description or quantity, whether expressed or implied, and there are no implied warranties of fitness for a particular purpose or of merchantability.
Record your operation code for future reference:
OP CODE 1 _____________________________________ OP CODE 2 _____________________________________ OP CODE 3 _____________________________________
ALARM MONITOR | Instruction | 1st Edition | November 2004
Compu-TTY, Inc.
3408 Indale Road, Fort Worth, Texas 76116 Voice or TTY: (817) 738-8993 or (817) 738-2485, Fax: (817) 738-1970 E-mail: info@computty.com, Website: http://www.computty.com
CONTENTS
i. Introduction......................................................................................ii
ii. KA300 System...................................................................................1
1. How your Alarm Monitor KA300 Works ......................................2
Using KA300 for a Single Family Household.........................................................2
Install KA300 for Single Family Home...................................................................3
Time-Condition-Signal.............................................................................................4
For Hotel, Dormitory or Multi-Family Household..................................................4
Install KA3000 for Multi-Family or Hotel ..............................................................5
2. Installing Battery..............................................................................6
KA300TX, KA300RX, and KBS300RX .................................................................6
3. Setup Operation Code .....................................................................7
KA300TX Transmitter .............................................................................................7
Mounting the KA300TX on the Existing Alarm .....................................................8
KA300RX Receiver .................................................................................................8
Erase KA300RX Memory........................................................................................8
Mounting the KA300RX on the wall.......................................................................9
KBS300RX Bed Shaker Receiver............................................................................9
Bed Shaker LED Indicator.....................................................................................10
Installing the KA300 System for first time............................................................10
4Test & TroubleShooting.................................................................12
Testing ....................................................................................................................12
TroubleShooting.....................................................................................................13
5 Specification....................................................................................14
.i
i. INTRODUCTION
The alarm Monitor KA300 is developed to bridge the gap created by the existing warning devices designed only for the hearing. It provides a totally reliable source for the Deaf and Hard of Hearing to watch and to be alerted when there is a fire, smoke, propane, gas leak alarm, tornado, hurricane, severe thunder storm alert, or when a national attack warning activates its siren. You will be worry free to select any alarm system designed without considering whether it supports the hearing impaired.
You will find its lifesaving features especially with multifamily, dormitory, or hotel’s alarm system while you are asleep and the evacuating siren is activated. It also lets you know what source triggered the alarm.
It is very easy to install the KA300TX sensor directly to the existing alarm system. It could save you a great cost to equip the local Hearing Impaired compatible alarm device. Most of existing alarm devices, if it is separated from source of the smoke, will not alert you when there is a fire that happens somewhere in a multi-room build­ing or will not respond to the evacuating siren.
For a single-family household, KA300 gives you great flexibility to build your own system with multiple transmitters and multiple receivers. It operates based upon code protection. The wireless link will save you from wiring the system and help to install the whole alarm monitor system within minutes.
For maximum safety, the KA300RX main receiver works with both AC and battery backup. In AC adapter mode, KA300RX triggers the alarm with the 177,000mCd strobe light, loud siren and ultra-light 1,000mCd LEDs. If the AC power failed, the unit will go to battery backup mode. The ultra-light LED and the siren will be acti­vated. The strobe light will not work in battery backup mode.
KBS300RX is equipped with a strong bed shaker that will guaranty to wake the deep­est sleeper.
The technique of Time-Condition-Signal verifying, combined with a fine tuning threshold, substantially reduces the possibility of a nuisance alarm. The operation code can be changed easily to stop false alarms that are caused from a neighboring Alarm Monitor system.
Since you are solely responsibility for your fire and hazards protection, test the sys­tem weekly and check battery backup regularly to maintain the efficiency operation. A failed operating system will not protect you.
Please read this user manual carefully first to understand the operation of the system before planning anything and keep it for future reference.
* Keep your sale receipt with this manual in case that you need warranty service.
.ii
ii. KA300 SYSTEM
KA300RX
receiver
KBS300RX with bed shaker
KA300TX
KWA300TX
STROBE
ADAPTER INDICATOR
BATTERY LOW INDICATOR
LOUDSPEAKER
MODE SELECTOR
CHANNEL LEDS
PROGRAM
OP/LOW BATTERY
RESET
SHAKER
OPERTATION
OP.CODE/CHANNEL COVER
TEST BUTTON
ON/OFF SWITCH
OPERTATION-CODE CHANNEL COVER
ALARM MONITOR KA300 WORKS
KA300system is designed to monitor all existing acoustic alarm units in your living area and transfer it to a visual and vibration alarm. It will quickly help you to determine what source triggered the alarm and give you enough time to evacuate from the building or to locate a shelter. The KA300 is not an alarm system but it is the vital source for the Deaf and Hearing Impaired to rely upon in an emergency. In most cases, the alarm was caused by Fire, Smoke, Carbon monoxide, hurricane, tornado, earthquake, etc.
USING KA300 FOR A SINGLE FAMILY HOUSEHOLD
You must choose one operation code for KA300 system used for your house. Set all transmitters KA300TX to that operation code. All KA300TX used for a smoke detector will be set to channel one. The other will be set for channel two and three. There will be no limit for the number of transmit­ters used in the same channel setting. However, the distance from the TX to the RX will be limited to around 100 feet. If you have a KBS300RX bed shaker, you need to program the operation code for it when you program the KA300RX. You can program the bed shaker at a different time. It will be more convenient to program the operation code for both receivers at the same time.
Note: The toggle switch will be either in the ON or OFF position. We will call ON position 1 and the
OFF position 0. For example, if all 8 switches are in the ON position, we will write 1111 1111 for that setup code.
CHAPTER
1
HOW YOUR....
2
Loading...
+ 14 hidden pages