Please read through these instructions carefully
before installing or operating. Following the installation,
pass the instructions on to the operator. This unit must
be installed and commissioned in accordance with the
regulations and standards in force. These instructions can
also be found at www.docuthek.com.
Explanation of symbols
• , , , ... = Action
▷ = Instruction
Liability
We will not be held liable for damage resulting from nonobservance of the instructions and non-compliant use.
Safety instructions
Information that is relevant for safety is indicated in the
instructions as follows:
All interventions may only be carried out by qualified gas
technicians. Electrical interventions may only be carried
out by qualified electricians.
Conversion, spare parts
All technical changes are prohibited. Only use OEM spare
parts.
Changes to edition 06.
The following chapters have been changed:
– BGT SA-9U/1DP connection diagram
– Certification
GB-1
GB
F
NL
I
E
Checking the usage
PFA 700
Fieldbus interface for interworking of up to nine automatic
burner control units PFU 760 or PFU 780 to industrial communication networks using PROFIBUS DP. The PFA700
can be plugged into the pre-wired module subrack BGT
SA-9U/1DP, together with the automatic burner control
units.
PFA 70
Fieldbus interface for interworking of up to eight automatic
burner control units PFU 780 to industrial communication networks using PROFIBUS DP. The PFA710 can
be plugged into the pre-wired module subrack BGT SA8U/1DP, together with the automatic burner control units.
PFA 700, PFA 70
This function is only guaranteed when used within the
specified limits – see page 7 (Technical data). Any
other use is considered as non-compliant.
Type code
CodeDescription
PFAFieldbus interface
700
0
7
T
Mains voltage: 220/240 V AC
N
ZSpecial version
Part designations
For connecting:
PFU 760
PFU 780
110/120 V AC
BGT SA-9U/DP
Pre-wired module subrack for a fieldbus interface PFA700
with nine further slots for automatic burner control units
PFU 760 or PFU 780.
BGT SA-8U/DP
Pre-wired module subrack for a fieldbus interface PFA710
with eight further slots for automatic burner control units
PFU 780.
BGT SA-9U/DP, BGT SA-8U/DP
This function is only guaranteed when used within the
specified limits – see page 7 (Technical data). Any
other use is considered as non-compliant.
Type code
CodeDescription
BGT19" module subrack
SAFor PFA and PFU
-9U
-8U
Slots: 9 × for PFU
8 × for PFU
/DP1 PFA with PROFIBUS DP
Part designations
3
1
2
1
6
1
3
2
4
6
5
7
8
LED display for program status and error messages
Reset/Information button
On/Off button
4 Type label
5 Connection for opto-adapter
6 Screws for attachment to the subrack
7 Code switches for address setting
8 CD with device master data (GSD file)
Input voltage and ambient temperature – see type label.
Input and output voltage, enclosure and ambient temperature – see type label.
BGT SA
GB-2
GB
F
NL
I
E
Installing the BGT
483 mm
1, 2
A
P
DI
on
on
on
1, 2
A
P
DI
on
on
on
1, 2
1, 2
A
P
DI
on
on
on
1, 2
A
P
DI
on
on
on
1, 2
1, 2
A
P
DI
on
on
on
1, 2
1, 2
1, 2
A
P
DI
on
on
on
1, 2
1, 2
A
P
DI
on
on
on
1, 2
1, 2
A
P
DI
on
on
on
1, 2
1, 2
A
P
DI
on
on
on
1, 2
1, 2
A
P
DI
on
on
on
1, 2
1, 2
A
P
on
on
CAUTION
Please observe the following to ensure that the PFA and
the automatic burner control units PFU are not damaged
during operation:
– It must be ensured that the module subrack is well
ventilated in order to avoid overheating.
– In the case of several module subracks mounted on
top of one another, we recommend removing the perforated plates A from between the module subracks,
and inserting a rack-mounted fan B underneath the
module subracks.
88 88 88 88 88 88 88 88 8888
88 88 88 88 88 88 88 88 8888
A
Wiring the BGT
Disconnect the system from the electrical power sup-
ply.
▷
Use a resistor with low impedance at high frequencies
for grounding the BGT.
▷
Ensure an equipotential bond between the various
slaves.
▷Switch on the terminal resistor on the first (PLC) and
last (BGT/PFA) station on the Profibus plug– see page
12 (Profibus plug for PFA).
▷ There are four digital inputs (X10.1 to X10.4) and four
digital outputs (X10.6 to X10.9) available.
▷Load per input: 24 V DC, ± 10%, <10mA.▷Load per output: relay contact, max. 1 A, 24 V (not
fused internally).
BGT SA-9U/DP
Wire as shown on the circuit diagram, see page 8
(BGT SA-9U/1DP connection diagram).
BGT SA-8U/DP
Wire as shown on the circuit diagram, see page 10
(BGT SA-8U/1DP connection diagram).
88 88 88 88 88 88 88 88 8888
Setting the PFA
▷
All the unit-specific parameters for the PFA are saved
in a device master data file (GSD file, see www.
docutheck.com).
Copy device master data for the PFA into the program-
B
mable logic controller (PLC).
▷
The steps required to copy the file are described in
the instructions for the PLC.
A
Configure the PROFIBUS DP using the appropriate
tools for the PLC you are using.
▷
The PFA will automatically identify the baud rate (max.
1.5 Mbit/s).
132
mm
200 mm
58
mm
465 mm
▷ The max. range depends on the baud rate:
Baud rateRange
[kBit/s][m] [yd]
93.7512001300
187.510001090
500400545
1500200220
▷ The ranges may be increased by using repeaters. Do
not connect more than three repeaters in series.
DANGER
Electric shocks can be fatal! Module subracks must be
integrated in the equipotential bonding system.
Ready for operation
Burner start-up signal
Start-up signal, pilot burner
Start-up signal, main burner
Purge
External air valve control
Burner operating signal
Operating signal, pilot burner
Operating signal, main burner
Fault signal
Reset
Input signal
Output signal
Address setting
Set the Profibus address on the PFA using the code
switches.
114 dec
1
0
0
F
2
9
3
E
4
D
8
5
C
7
6
B
7
A
6
8
9
PFU 8
PFU 9
PFA
1
2
3
4
PFA
PFA
PFA
PFA
1
2
3
4
5
▷
At the factory, the Profibus address on the PFA is
set to 04.
Installing the PFA
1
▷Ensure that the PFA is correctly inserted.
1
2
3
4
Replacing the PFA
▷
The old PFA 700 (Order No. 84395100 – see type
label) can be replaced with the new PFA 700 (Order
No. 84395101 or 84395102) in the module subrack
BGT SA-9U/1DP (Order No. 84402283).
84395100
1
2
3
4
▷ To increase the EMC interference immunity, the new
Profibus plug supplied must be used for the new PFAs
(Order No. 84395101 or 84395102).
Check the voltage.
4 Read off the Profibus address on the old PFA.
5 Accept and set the Profibus address on the new PFA
– see page 4 (Address setting).
6 Install the new PFA – see page 4 (Installing the
PFA).
7 Check the operating parameters for manual mode on
the new PFA and adjust where applicable.
8 Replace the Profibus plug on the BGT with the Profi-
bus plug with shielding capacitor – see page 12
(Profibus plug for PFA).
GB-4