KREBS LM25, LM45 Operating Instructions Manual

Operating Instructions
KREBS LM45
(45-L)
KREBS LM25
(25T-L)
2
1
2
3
4
Spraying
Dismantling the pump
3
Before start-up
Observe the supply voltage! The voltage specifi ed on the nameplate must conform to the supply voltage.
Nominal output 60 W 120 W Delivery rate (water) 260 g/min 350 g/min Viscosity rate 120 DIN-sec 160 DIN-sec Dynamic pressure 0 - 160 bar 0 - 180 bar Vibration level 9 m/s2 9 m/s2 Container capacity approx. 0,7 l approx. 0,7 l Weight approx. approx. 1,1 kg approx. 1,4 kg Protection rating / II / II
Technical data LM25 (K25T-L) LM45 (K45-L)
For your safety
This spray gun can only be operated safely when the operating and the safety in­structions have been completely read and are strictly adhered to. It is recommended to receive practical instruction before using the machine for the fi rst time.
Do not use the spray gun if damp or if the surroundings are damp.
Always check the spray gun, power cord and plug before use. In the event of damage, repair work should only be carried out by specialist.
Ensure that there is adequate ventilation when working in confi ned spaces.
Danger of Explosion!
The spray gun must not be used in locations where explosive gases may occur.
Do not spray infl ammable or explosive liquids (e.g. petrol or spirit).
Never direct the spray jet towards people or animals. The spray material comes out of the nozzle at high pressure. Danger of injury and infection.
The noise level of the spray gun can exceed 85 dB(A), therefore wear ear protection.
Do not use the spray gun without spray material.
Only connect the power plug when the spray gun is OFF. Disconnect the power plug after use. Always disconnect the power plug before performing any work on the spray gun. Do not carry the spray gun by the power cord. Always keep the extension cable well away from the workplace. Keep the spray gun and accessories out of the reach of children. Only use original accessories and spare parts.