Feature
The Motion Detector is a KRC Zigbee enabled device which is fully compatible
with any KRC product
This Motion Detector can control our modules via controller setting. Inclusion of
this
Motion Detector on Wireless Controller menu allows remote
turn-on of connected modules when the detector is triggered.
The Motion Detector is designed with include ambient light level and sensitivity
adjustments , in order to fulfill the purpose of security and home automation.
When the detector is cooperated with security appliances, it is acting
as a security device by detecting changes in infra-red radiation levels. If a person
moves within or across the device field of vision, a trigger radio signal will be
transmitted to cause full alarm condition in order to frighten intruders away.
Alternatively, when the detector is worked with home automation appliances, the
detector can be set to perform the role of home automation device by detecting
both changes in infra-red radiation levels and percentage of lux levels. Once night
falls,the percentage of ambient illumination is lower than preset value. If a person
moves within or across the device field of vision, a trigger radio signal will be
transmitted so as to turn on the connected lightings for better illumination.
The PIR Detector adopts a CR123A , 3.0V Lithium battery which under normal
conditions will have typical life in excess of 1 year. When the battery level drops
to an unacceptable level, device will notify backgroune. When this occurs the
batteries should be replaced as soon as possible.
.
Product Specification
Power:CR123A battery
Working current:38mA
Detection type :Passive
Operating temperature:0~40℃
Humidity:95%RH

Product Overview
Battery
TamperSW
Choosing a Mounting Location
The PIR Detector is suitable for mounting in dry interior locations only.
The recommended position for a PIR Detector is in the corner of a room mounted
at
a height between 2 and 2.5m. At this height, the detector will have a maximum
range of up to 16m with a field of view of 90°

Troubleshooting
Symptom Possible Cause Recommendation
LED cannot be displayed
correct polarity
The detector not working Check if mounting Reposition its mounting
location is proper location
Remove the source of
interference
Run out of battery
power
Check if reverse battery
polarity
Replace a new battery
Refit the battery with
Federal Communication Commission Interference Statement
This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may
cause
harmful interference to radio communications. However, there is no guarantee
that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be
determined
by turning the equipment off and on, the user is encouraged to try to correct the
interference by one of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and
(2)
this device must accept any interference received, including interference that may
cause undesired operation.
FCC Caution: Any changes or modifications not expressly approved by the party
responsible for compliance could void the user's authority to operate this
equipment.
This transmitter must not be co-located or operating in conjunction with any other
antenna or transmitter.
Non-modification Statement:
Changes or modifications not expressly approved by the part y responsible for compliance
could void the user's authority to operate the equipment.
FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with minimum distance
20cm between the radiator & your body.