Page 1
Kramer Electronics, Ltd.
Preliminary
USER MANUAL
Model:
VP-300THD
1:2 XGA/HD DA/CAT 5 Transmitter
Page 2
Contents
1 Introduction 1 2 Getting Started 1
2.1 Quick Start 2
3 Overview 3
3.1 About the Power Connect Feature 4
3.2 Shielded Twisted Pair (STP) / Unshielded Twisted Pair (UTP) 4
4 Your VP-300THD 1:2 XGA/HD DA/CAT 5 Transmitter 5 5 Connecting the VP-300THD 6
5.1 Wiring the CAT 5 LINE IN / LINE OUT RJ-45 Connectors 8
6 Technical Specifications 8
Figures
Figure 1: VP-300THD 1:2 XGA/HD DA/CAT 5 Transmitter 5 Figure 2: VP-300THD 1:2 XGA/HD DA/CAT 5 Transmitter (Underside) 6 Figure 3: Connecting the VP-300THD 7 Figure 4: CAT 5 PINOUT 8
Tables
Table 1: VP-300THD 1:2 XGA/HD DA/CAT 5 Transmitter Features 5 Table 2: VP-300THD 1:2 XGA/HD DA/CAT 5 Transmitter (Underside) Features 6 Table 3: CAT 5 PINOUT 8 Table 4: Technical Specifications of the VP-300THD (with 30m CAT 5 cable) 8
i
Page 3
Introduction

1 Introduction

Welcome to Kramer Electronics! Since 1981, Kramer Electronics has been providing a world of unique, creative, and affordable solutions to the vast range of problems that confront the video, audio, presentation, and broadcasting professional on a daily basis. In recent years, we have redesigned and upgraded most of our line, making the best even better! Our 1,000-plus different models now appear in 11 groups
1
that are clearly
defined by function.
Thank you for purchasing the Kramer VP-300THD 1:2 XGA/HD DA/CAT 5 Transmitter, which is ideal for:
Presentation and multimedia applications
Long range graphics distribution for schools, hospitals, security, and
stores
Each package includes the following items:
The VP-300THD 1:2 XGA/HD DA/CAT 5 Transmitter
Power supply (12V DC)
This user manual
2

2 Getting Started

We recommend that you:
Unpack the equipment carefully and save the original box and
packaging materials for possible future shipment
Review the contents of this user manual
Use Kramer high performance high-resolution cables
3
1 GROUP 1: Dis tribution Amplifiers; GROUP 2: Switc hers and Matrix Swi tchers; GROUP 3: Co ntrol Systems;
GROUP 4: Format/Standards Converters; GROUP 5: Range Extenders and Repeaters; GROUP 6: Specialty AV Products;
GROUP 7: Scan C onverters and Scalers; GROUP 8: Cables and Connectors; GROUP 9: Room Connectivity;
GROUP 10: Accessories and Rack Adapters; GROUP 11: Sierra Products
2 Download up-to-date Kramer user manuals from our Web site at http://www.kramerelectronics.com
3 The complete list of Kramer cables is on our Web site at http://www.kramerelectronics.com
1
Page 4
Getting Started

2.1 Quick Start

This quick start chart summarizes the basic setup and operation steps.
Step 1: Connect the input and the outputs
Connect the input
Connect the input
1
Connect the outputs
Connect the outputs
2
Connect the CAT 5 cable between the
Connect the CAT 5 cable between the
3
transmitter (VP-300THD) and the
transmitter (VP-300THD) and the
receiver (TP-120)
receiver (TP-120)
VP-300THD
VGA
Display
VGA
Projector
3
VGA
Display
2
CAT 5
OUTPUT1
OUTPUT2
TP-120
LINEOUT
3
VP-300THD
Computer Graphics Source
1
1:2XGA/HD /CAT5TransmitterDA
VGA
Step 2: Connect the power
Step 3: If required:
m
Set the polarity and the ID bit using the underside switches
m
Set the polarity and the ID bit using the underside switches
2
KRAMER: SIMPLE CREATIVE TECHNOLOGY
Page 5

3 Overview

Overview
The VP-300THD is a high-performance distribution amplifier for computer
graphics video signals
1
with resolutions ranging from VGA through UXGA and higher as well as HDTV. It takes one input, provides correct buffering and isolation, and distributes the signal to two computer graphics video or HDTV outputs and one twisted pair output.
The VP-300THD features:
HDTV compatibility
H & V sync polarity switches for improved HDTV compatibility with
the CAT 5 outputs
ID bit control
A resolution of up to WUXGA and 1080p
A transmission range of more than 300 feet (more than 100 meters)
The Power Connect feature (see section 3.1
)
12V DC power
To achieve the best performance:
Use only good quality connection cables
2
to avoid interference, deterioration in signal quality due to poor matching, and elevated noise levels (often associated with low quality cables).
Avoid interference from neighboring electrical appliances that may
adversely influence signal quality and position your Kramer
VP-300THD away from moisture, excessive sunlight and dust
1 Note that the CAT5 connector excludes audio
2 Available from Kramer Electronics on our Web site at http://www.kramerelectronics.com
3
Page 6
Overview

3.1 About the Power Connect Feature

The Power Connect feature applies as long as the cable can carry power. This feature is available when using STP cable and the distance does not exceed 50m on standard CAT 5 cable. For longer distances, heavy gauge cable should be used
1
. For units which are connected via RJ-45 connectors, make sure that the shield of the STP cable is connected to the metal casing of the connectors on both ends of the cable. For units which are connected via terminal block connectors, the shield of the STP cable must be connected to a ground terminal on the units at both ends (use the ground terminal of the power supply connection if necessary).
For a CAT 5 cable exceeding a distance of 50m, separate power supplies
should be connected to the transmitter and to the receiver simultaneously.

3.2 Shielded Twisted Pair (STP) / Unshielded Twisted Pair (UTP)

We
recomm
end that you use Shielded Twisted Pair (STP) cable. There are different levels of STP cable available, and we advise you to use the best quality STP cable that you can afford. Our non-skew-free cable, Kramer
BC-STP is intended for analog signals where skewing is not an issue. For cases where there is skewing, our UTP skew-free cable, Kramer BC-XTP,
may be used. Bear in mind, though, that we advise using STP cables where possible, since the compliance to electromagnetic interference was tested using those cables.
Although Unshielded Twisted Pair (UTP) cable might be preferred for long range applications, the UTP cable should be installed far away from electric cables, motors and so on, which are prone to create electrical interference. However, since the use of UTP cable might cause inconformity to electromagnetic standards, Kramer does not commit to meeting the standard with UTP cable.
1 CAT 5 cable is still suitable for the video/audio transmission, but not for feeding the power at these distances
4
KRAMER: SIMPLE CREATIVE TECHNOLOGY
Page 7
Your VP-300THD 1:2 XGA/HD DA/CAT 5 Transmitter

4 Your VP-300THD 1:2 XGA/HD DA/CAT 5 Transmitter

Figure 1 and Table 1 define the VP-300THD:
433
2
5
1
6
1
2
5
Figure 1: VP-300THD 1:2 XGA/HD DA/CAT 5 Transmitter
Table 1: VP-300THD 1:2 XGA/HD DA/CAT 5 Transmitter Features
# Feature Function
1 OUTPUT 1 15-pin HD
Connector 2 OUTPUT 2 15-p in HD C o nn e c to r Connect to the XGA acceptor 2 3 LINE OUT RJ-45 Connector Connects to1 the LINE IN RJ-45 connector
4
12V DC
Connect to the XGA acceptor 1
on the TP-120 XGA Line Receiver +12V DC connector for powering the unit
2
Figure 2 and Table 2 define the underside of the VP-300THD:
4
6
1 Using a UTP CAT5 cable with RJ-45 connectors at both ends (the PINOUT is defined in Table 3 and Figure 4)
2 Refer to the separate user manual: PT-110, PT-120, TP-120, WP-110, which can be do wnloaded from the Internet at this
URL: http://www.kramerelectronics.com
5
Page 8
Connecting the VP-300THD
Figure 2: VP-300THD 1:2 XGA/HD DA/CAT 5 Transmitter (Underside)
Table 2: VP-300THD 1:2 XGA/HD DA/CAT 5 Transmitter (Underside) Features
# Feature Function
1 HS Switch Slide the switch to the right to change the HS polarity to NEG. (NEGATIVE) polarity1;
slide the switch to the left
2 VS Switch Slide the switch to the right to change the VS polarity to NEG. (NEGATIVE) polarity1;
slide the switch to the left
3 ID BIT Switch Slide to the right to set to ON3; to the left to set to OFF
2
(to NORMAL) to retain the polarity
2
(to NORMAL) to retain the polarity

5 Connecting the VP-300THD

You can use the VP-300THD and, for example, the TP-120 to configure an XGA/HD DA/CAT 5 Transmitter and Receiver system.
To connect the VP-300THD with the TP-120, as the example in Figure 3
illustrates, do the following:
1. On the VP-300THD 1:2 XGA/HD DA/CAT 5 Transmitter, connect the:
Computer graphics (XGA / HD) source (for example, a computer)
to the INPUT 15-pin HD connector
OUTPUT 1 and OUTPUT 2 15-pin HD connectors to up to
4
acceptors (for example, to a display and to a projector, respectively)
1 Downgoing syncs
2 By default, both switches are set to the left
3 The default. Enabling the notebook or laptop to output a VGA signal to an external VGA monitor
4 When both outputs are not required, connect only the output that is required and leave the other output unconnected
6
KRAMER: SIMPLE CREATIVE TECHNOLOGY
two
Page 9
Connecting the VP-300THD
2. On the TP-120 XGA Line Receiver, connect the XGA OUT 15-pin HD
connector to the XGA / HD acceptor (for example, a display).
3. Connect the LINE OUT RJ-45 connector on the VP-300THD to the LINE IN RJ-45 connector on the TP-120, via UTP cabling (with a range of more
than 300ft (more than 100 meters)), see section 3.2
.
4. Connect the 12V DC power adapter to the power socket on the
VP-300THD, and plug the adapter into the mains electricity socket.
Similarly, connect the other 12V DC power adapter to the power socket on
the TP-120, and plug that adapter into the mains electricity socket.
5. On the VP-300THD, if required: Set the ID BIT switch to ON
1
Set the VS and HS switches
on the underside
6. On the TP-120, if required: Adjust
2
the video output signal level and/or cable compensation
equalization level
Set the H SYNC and V SYNC switches
3
, on the underside
VP-300THD
VGA
Display
VGA
Projector
VGA
Display
CAT 5
OUTPUT1
OUTPUT2
TP-120
LINEOUT
VP-300THD
Computer Graphics Source
Figure 3: Connecting the VP-300THD
1 By default, both switches are set to the left (to NORMAL) to retain the VS and HS polarit y
2 Use a screwdriver to carefully rotate the trimmer, adjusting the appropriate level
3 By default, both switches are set down (for normal V SYNC and H SYNC polarity)
1:2XGA/HD /CAT5TransmitterDA
VGA
7
Page 10
Technical Specifications
r
r

5.1 Wiring the CAT 5 LINE IN / LINE OUT RJ-45 Connectors

Table 3
and Figure 4 define the UTP CAT 5 PINOUT, using a straight pin
to pin cable with RJ-45 connectors:
Table 3: CAT 5 PINOUT
EIA /TIA 568A EIA /TIA 568B
PIN Wire Colo
1 Green / White 1 Orange / White 2 Green 2 Orange 3 Orange / White 3 Green / White 4 Blue 4 Blue 5 Blue / White 5 Blue / White 6 Orange 6 Green 7 Brown / White 7 Brown / White 8 Brown 8 Brown
Pair 1 4 and 5 Pair 1 4 and 5 Pair 2 3 and 6 Pair 2 1 and 2 Pair 3 1 and 2 Pair 3 3 and 6 Pair 4 7 and 8 Pair 4 7 and 8
PIN Wire Colo
Figure 4: CAT 5 PINOUT

6 Technical Specifications

This section includes the technical specifications
Table 4: Technical Specifications of the VP-300THD (with 30m CAT 5 cable)
INPUT: 1 XGA on an 15-pin HD connector OUTPUTS: 2 XGA on 15-pin HD connectors; 1 RJ-45 connector MAX. OUTPUT
2
LEVEL
: RESOLUTION: Up to UXGA DIFF. GAIN2: 0.03% (XGA), 2.6% (CAT 5) DIFF. PHASE2: 0.05Deg (XGA), 0.28 Deg (CAT 5) K-FACTOR2: <0.05% (XGA), 0.1% (CAT 5) S/N RATIO2: 75dB (XGA), 71dB (CAT 5) CONTROLS2: LEVEL: –9.1dB to 2.3dB (CAT 5)
COUPLING2: DC (XGA), AC (CAT 5) POWER SOURCE: 12V DC, 280mA DIMENSIONS: 12cm x 7.5cm x 2.5cm (4.7" x 2.95" x 0.98") W, D, H WEIGHT: 0.3 kg. (0.67 lbs.) approx. ACCESSORIES: Power supply OPTION: RK-3T 19" rack adapter
2.3Vpp (XGA), 1.4Vpp (CAT 5)
EQ.: 0 to 35dB (CAT 5)
1
of the VP-300THD.
1 Specifications are subject to change without notice
2 “CAT 5” specifications refer to a VP-300THD to TP-120 configuration
8
KRAMER: SIMPLE CREATIVE TECHNOLOGY
Page 11
LIMITED WARRANTY
Kramer Electronics (hereafter ) warrants this product free from defects in material and workmanship under the following terms.
HOW LONG IS THE W ARRANTY
Labor and parts are warranted for seven years from the date of the first customer purchase.
WHO IS PROTECTED?
Only the first purchase customer may enforce this warranty.
WHAT IS COVERED AND WHA T IS NO T COVERED
Except as below, this warranty c overs all defects in material or workma nship in this product. The following are not c overed by the warranty:
1. Any product which is not distributed by Kramer, or which is not purchased from an authorized Kramer dealer. If you are uncertain as to whether a d ealer is authorized, please contact Kramer at one of the agents listed in the Web site www.kramerelectronics.com.
2. Any product, on which the serial number has been defaced, modified or removed, or on which the WA RRANTY VOID
TAMPERED sticker has been torn,
IF reattached, removed or otherwise interfered with.
3. Damage, deterioration or malfunction resulting from:
i) Accident, misuse, abuse, neglect, fire, water, lightning or other acts of nature ii) Prod uct modif ication, o r failure to follo w instruc tions supp lied wi th the prod uct iii) Repair or attempted repair by anyone not authorized by Kramer iv) Any shipment of the product (claims must be presented to the carrier) v) Removal or installation of the product vi) Any other cause, which does not relate to a product defect vii) Cartons, equipment enclosures, cables or accessories used in conjunction with the product
WHAT WE WILL PAY FOR AND WHAT WE WILL NOT PAY FOR
We will pay labor and material expenses for covered items. We will not pay for the following:
1. Removal or installations charges.
2. Costs of initial technical adjustments (set-up), including adjustment of user controls or programming. These costs are the
responsibility of the Kramer dealer from whom the product was purchased.
3. Shipping charges.
HOW YOU CAN GET WARRANTY SERVICE
1. To obtain service on you product, you must take or ship it prepaid to any authorized Kramer service center.
2. Whenever warranty service is required, the original dated invoice (or a copy) must be presented as proof of warranty
coverage, and should be included in any shipment of the product. Please also include in any mailing a contact name, company, address, and a description of the problem(s).
3. For the name of the nearest Kramer authorized service center, consult your authorized dealer.
LIMITATION OF IMPLIED WARRANTIES
All implied warranties, including warranties of merchantability and fitness for a particular purpose, are limited in duration to the leng th of th is warra nty.
EXCLUSION OF DAMAGES
The liability of Kramer for any effective products is limited to the repair or replacement of the product at our option. Kramer shall not be liable for:
1. Damage to other property caused by defects in this product, damages based upon inconvenience, loss of use of the product, loss
of time, commerc ial loss; or:
2. Any other damages, whether incidental, consequential or otherwise. Some countries may not allow limitations on how long an
implied warranty lasts and/or do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations and exclusions may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights, which vary from place to place.
NOTE:
All products returned to Kramer for service must have prior approval. This may be obtained from your dealer.
This equipment has been tested to determine compliance with the requirements of:
EN-50081: "Electromagnetic compatibility (EMC);
Residential, commercial and light industry" EN-50082: "Electromagnetic compatibility (EMC) generic immunity standard.
CFR-47: FCC* Rul es and Regulations:
CAUTION!
generic emission standard. Part 1:
Part 1: Residential, commercial and light industry environment".
Part 15: “Radio frequency devices Subpar t B Uninten tional radia tors”
Servicing the machines can only be done by an authorized Kramer technician. Any user who makes changes or modifications to the unit without the expressed approval of the manufacturer will void user authority to operate the equipment.
Use the supplied DC power supply to feed power to the machine.
Please use recommended interconnection cables to connect the machine to other components. * FCC and CE approved using STP cable (for twisted pair products)
Kramer
9
Page 12
For the latest information on our products and a list of Kramer
distributors, visit our Web site: www.kramerelectronics.com,
where updates to this user manual may be found.
We welcome your questions, comments and feedback.
Safety Warning:
Disconnect the unit from the power supply before opening/servicing.
Caution
P/N:
2900-000182
Rev:
3
Kramer Electronics, Ltd.
Web site: www.kramerelectronics.com
E-mail: info@kramerel.com
P/N: 2900-000182 REV 3
Loading...