Kramer WP-110xl User Manual

Page 1
KRAMER ELECTRONICS LTD.
USER MANUAL
MODEL:
WP-1 10xl
UXGA/Data Line Transmitter
P/N: 2900-300294 Rev 2
Page 2
Page 3
WP-110xl – Contents
i
Contents
1 Introduction 1 2 Getting Started 2
2.1 Achieving the Best Performance 2
2.2 Safety Instructions 3
2.3 Shielded Twisted Pair/Unshielded Twisted Pair 3
2.4 Recycling Kramer Products 3
3 Overview 4
3.1 About the Power Connect™ Feature 4
4 Defining the WP-110xl UXGA/Data Line Transmitter 5 5 Connecting and Installing the WP-110xl 7
5.1 Grounding the Wall Plate 8
5.2 Wiring the TP LINE OUT RJ-45 Connector 9
6 Capturing the EDID 10
6.1 Capturing the EDID from a Display Device 10
6.2 Loading the Default EDID 11
7 Technical Specifications 13
Figures
Figure 1: WP-110xl UXGA/Data Line Transmitter 5 Figure 2: Connecting the WP-110xl UXGA/Data Line Transmitter 7 Figure 3: Ground Connection 8 Figure 4: TP PINOUT 9 Figure 5: WP-110xl US Wall Plate 11 Figure 6: WP-110xl EU Wall Plate 12
Page 4
WP-110xl - Introduction
1
1 Introduction
Welcome to Kramer Electronics! Since 1981, Kramer Electronics has been providing a world of unique, creative, and affordable solutions to the vast range of problems that confront video, audio, presentation, and broadcasting professionals on a daily basis. In recent years, we have redesigned and upgraded most of our line, making the best even better!
Our 1,000-plus different models now appear in 11 groups that are clearly defined by function: GROUP 1: Distribution Amplifiers; GROUP 2: Switchers and Routers; GROUP 3: Control Systems; GROUP 4: Format/Standards Converters; GROUP 5: Range Extenders and Repeaters; GROUP 6: Specialty AV Products; GROUP 7: Scan Converters and Scalers; GROUP 8: Cables and Connectors; GROUP 9: Room Connectivity; GROUP 10: Accessories and Rack Adapters and GROUP 11: Sierra Products.
Congratulations on purchasing your Kramer WP-110xl UXGA/Data Line Transmitter, which is ideal for the following typical applications:
Presentation and multimedia applications Long range graphics distribution for schools, hospitals, stores and security
applications
Page 5
2
WP-110xl - Getting Started
2 Getting Started
We recommend that you:
Unpack the equipment carefully and save the original box and packaging
materials for possible future shipment
Review the contents of this user manual
Go to
http://www.kramerelectronics.com/support/product_downloads.asp
to check for up-to-date user manuals, application programs, and to check if firmware upgrades are available (where appropriate).
2.1 Achieving the Best Performance
To achieve the best performance:
Use only good quality connection cables (we recommend Kramer high-
performance, high-resolution cables) to avoid interference, deterioration in signal quality due to poor matching, and elevated noise levels (often associated with low quality cables)
Do not secure the cables in tight bundles or roll the slack into tight coils Avoid interference from neighboring electrical appliances that may adversely
influence signal quality
Position your Kramer WP-110xl away from moisture, excessive sunlight and
dust
This equipment is to be used only inside a building. It may only be connected to other equipment that is installed inside a building.
i
!
Page 6
WP-110xl - Getting Started
3
2.2 Safety Instructions
Caution:
There are no operator serviceable parts inside the unit
Warning:
Use only the Kramer Electronics input power wall adapter that is provided with the unit
Warning:
Disconnect the power and unplug the unit from the wall before installing
2.3 Shielded Twisted Pair/Unshielded Twisted Pair
We recommend that you use Shielded Twisted Pair (STP) cable, and stress that the compliance to electromagnetic interference was tested using STP cable. There are different levels of STP cable available, and we advise you to use the best quality STP cable that you can afford. Our non-skew-free cable, Kramer BC-STP is intended for analog signals where skewing is not an issue.
In cases where there is skewing, our Unshielded Twisted Pair (UTP) skew-free cable, Kramer BC-XTP, may be advantageous, and UTP cable might also be preferable for long range applications. In any event when using UTP cable, it is advisable to ensure that the cable is installed far away from electric cables, motors and so on, which are prone to create electrical interference.
2.4 Recycling Kramer Products
The Waste Electrical and Electronic Equipment (WEEE) Directive 2002/96/EC aims to reduce the amount of WEEE sent for disposal to landfill or incineration by requiring it to be collected and recycled. To comply with the WEEE Directive, Kramer Electronics has made arrangements with the European Advanced Recycling Network (EARN) and will cover any costs of treatment, recycling and recovery of waste Kramer Electronics branded equipment on arrival at the EARN
facility. For details of Kramer’s recycling arrangements in your particular country
go to our recycling pages at http://www.kramerelectronics.com/support/recycling/.
!
Page 7
4
WP-110xl - Overview
3 Overview
The WP-110xl is a high-performance, twisted pair (TP) transmitter for computer graphics signals over extended distances using CAT 5/6 cable.
The WP-110xl comes in three models: WP-110xl 69mm US version, WP-110xl 80/86mm European versions.
More specifically, the WP-110xl features:
Resolution up to WUXGA, 1080p HDTV compatibility up to 1080p Extended transmission range of up to 250m (820ft) EDID Capture copies and stores the EDID from a display device Increased level of protection against noise, spikes and interference in
adverse environments
3.1 About the Power Connect™ Feature
The Power Connect™ feature here means that only one unit in a system, the transmitter or receiver, needs to be connected to a power source when the
devices are within 60m (197ft) of each other. The Power Connect™ feature
applies as long as the cable can carry power and the distance does not exceed 60m on standard TP cable. (Heavier gauge cable may be used to extend the Power Connect™ range).
Page 8
WP-110xl - Defining the WP-110xl UXGA/Data Line Transmitter
5
4 Defining the WP-110xl UXGA/Data Line
Transmitter
This section defines the WP-110xl.
Figure 1: WP-110xl UXGA/Data Line Transmitter
Page 9
6
WP-110xl - Defining the WP-110xl UXGA/Data Line Transmitter
#
Feature
Function
1
PC IN 15-pin HD connector
Connects to the computer graphics source
2
ON LED
Lights when powered on
3
+12V/GND Terminal Block
Connects to the 12V DC power supply, (see
Section 3.1)
4
LINE OUTPUT RJ-45 Connector
Connects to the twisted pair line
5
Ground Terminal
Crimp terminal connects to earth
Page 10
WP-110xl - Connecting and Installing the WP-110xl
7
5 Connecting and Installing the WP-110xl
Always switch off the power to each device before connecting it to your WP-110xl. After connecting your WP-110xl, connect its power and then switch on the power to each device.
To connect the WP-110xl as illustrated in the example in Figure 2:
1. Connect a twisted pair line to the LINE OUTPUT RJ-45 connector.
2. Ground the wall plate (see Section 5.1).
3. Connect the 12V DC power supply to the 12V and GND terminals taking care to keep the correct polarity, (if required, see Section 3.1).
4. Install the WP-110xl into a suitable wall box or rack mount.
5. Connect a computer graphics source (for example, a PC) to the PC IN 15-pin HD connector.
Figure 2: Connecting the WP-110xl UXGA/Data Line Transmitter
i
Page 11
8
WP-110xl - Connecting and Installing the WP-110xl
5.1 Grounding the Wall Plate
Grounding the WP-110xl is recommended. The grounding wire is connected to the rear of the chassis of the unit. The grounding screw is used to earth the unit to the ground of the building. This helps prevent static electricity from interfering with product performance.
To connect the grounding to the WP-110xl as shown in Figure 3:
1. Crimp the ring-tongue terminal to the building grounding point wire.
(We recommend that you use a green-yellow #18 AWG wire (0.82mm2) crimped with a proper hand-tool).
2. Insert the M3x6 screw through the toothed lock washers and the ring-tongue terminal in the order shown above.
3. Insert the M3x6 screw (with the two toothed lock washers and ring-tongue terminal in place) into the grounding screw hole on the rear of the WP-110xl and tighten the screw.
Figure 3: Ground Connection
#
Item
1
M3x6 Screw
2
M3 Toothed lock washers
3
M3 Ring tongue terminal
Page 12
WP-110xl - Connecting and Installing the WP-110xl
9
5.2 Wiring the TP LINE OUT RJ-45 Connector
This section defines the TP pinout, using a straight pin-to-pin cable with RJ-45 connectors.
EIA /TIA 568B
Figure 4: TP PINOUT
PIN
Wire Color
1
Orange / White
2
Orange
3
Green / White
4
Blue
5
Blue / White
6
Green
7
Brown / White
8
Brown
Page 13
10
WP-110xl - Capturing the EDID
6 Capturing the EDID
The WP-110x can capture an EDID from a connected display or can load a default EDID when no display is available or the unit cannot capture the EDID from the connected display.
6.1 Capturing the EDID from a Display Device
To capture an EDID from a display:
1. Using a Philips screwdriver, remove the four screws holding the faceplate to the PCB assembly.
2. Using a short cable (for example, Kramer model number C-MGM/MGM-1), connect the PC IN input 15-pin HD connector on the WP-110xl to the 15-pin HD connector of the display and turn the display on.
3. Connect the 12V DC power adapter to the power terminal block (see
Figure 1) on the WP-110xl and connect the adapter to the mains electricity.
4. Press the EDID capture button (item 1 on Figure 5 and Figure 6). The EDID status LED (item 2 on Figure 5 and Figure 6) flashes slowly several times. The new EDID is captured when the LED stops flashing and lights solid.
Note: If the status LED flashes quickly for a few seconds and then stays on solid, the WP-110xl could not capture the EDID and loaded the default EDID instead.
5. Unplug the power adapter from the mains and disconnect it from the WP-110xl.
6. Replace the faceplate and secure the four screws removed in Step 1.
Page 14
WP-110xl - Capturing the EDID
11
6.2 Loading the Default EDID
To load the default EDID:
1. Using a Philips screwdriver, remove the four screws holding the faceplate to the PCB assembly.
2. Do not connect a display to the PC IN input 15-pin HD connector.
3. Connect the 12V DC power adapter to the power terminal block (see
Figure 1) on the WP-110xl and connect the adapter to the mains electricity.
4. Press the EDID capture button (item 1 on Figure 5 and Figure 6). The EDID status LED (item 2 on Figure 5 and Figure 6) flashes quickly for a few seconds and then stays on solid.
5. Unplug the power adapter from the mains and disconnect it from the WP-110xl.
6. Replace the faceplate and secure the four screws removed in Step 1.
Figure 5: WP-110xl US Wall Plate
Page 15
12
WP-110xl - Capturing the EDID
Figure 6: WP-110xl EU Wall Plate
Page 16
WP-110xl - Technical Specifications
13
7 Technical Specifications
INPUT:
1 VGA / UXGA on a 15-pin HD connector
OUTPUT:
1 RJ-45 LINE OUTPUT connector
VIDEO RESOLUTION:
Up to WUXGA, 1080p
RANGE:
Up to 250m (820ft)
COUPLING:
AC
POWER CONSUMPTION:
12V DC, 70mA
OPERATING TEMPERATURE:
0° to +40°C (32° to 104°F)
STORAGE TEMPERATURE:
-40° to +70°C (-40° to 158°F)
HUMIDITY:
10% to 90%, RHL non-condensing
WALL PLATE SIZE:
2 gang EU/US
DIMENSIONS:
2 gang USA: 11.4cm x 3.5 cm x 11.4cm (4.49" x 1.4" x
4.49", W, D, H) 2 gang Europe: 15.2cm x 3.5cm x 8.0/8.6cm (5.98" x
1.4" x 3.15/3.39", W, D, H)
WEIGHT:
0.14kg (0.31lbs) approx.
ACCESSORIES:
Power supply
OPTIONS:
19” rack adapters for EU and US wall plates; Kramer on-wall boxes
Specifications are subject to change without notice at http://www.kramerelectronics.com
Page 17
Page 18
For the latest information on our products and a list of Kramer distributors, visit our Web site where updates to this user manual may be found.
We welcome your questions, comments, and feedback.
Web site: www.kramerelectronics.com E-mail: info@kramerel.com
P/N:
2900-300294
Rev:
2
!
SAFE TY WARNI NG Disconnect the unit from the power supply before opening and servicing
Loading...