VS-21DTP Quick Start (P/N: 2900-300924QS REV 1)
VS-21DTP Quick Start Guide
This guide helps you install and use your VS-21DTP for the first time.
Go to www.kramerav.com/downloads/VS-21DTP to download the latest user manual and check if
firmware upgrades are available.
VS-21DTP 2xHDMI to HDBT Standby Switcher/POE
ACTIVE INPUT LEDs (1 to 2)
Lights green when the input is active. Both LEDs flash when no input is active.
Lights green when DIP-switch 1 is set to PRIORITY (down).
Lights green when DIP-switch 1 is set to LAST CONNECTED (up).
Lights green when the unit provides PoE.
Lights green when the unit is powered on via power adapter or PoE.
INPUT HDMI Connectors (1 to 2)
Connect to an HDMI source.
Connect to an HDBaseT receiver (for example, TP-580R) and provide or
accept power (bidirectional PoE).
LAST CONN/PRIORITY DIP-switch 1
Set DIP-switch 1 up (off) to select the Last Connected input.
Set DIP-switch 1 down (on) to select the Priority input determined by
DIP-switch 2.
Set DIP-switch 2 up (off) to define INPUT 1 as the default (priority) input.
Set DIP-switch 2 down (on) to define INPUT 2 as the default (priority) input.
REMOTE 3-pin Terminal Block Connector
Connects to optional contact closure switches 1 or 2 for manual switching (by
momentary contact between the desired pin and the G pin).
48V DC Power Terminal Block Connector
Connect to the Kramer power adapter.
Step 1: Check what’s in the box
Step 2: Get to know your VS-21DTP
Install VS-21DTP using one of the following methods:
Attach the rubber feet and place the unit on a flat surface.
Fasten a bracket (included) on each side of the unit and attach it to a flat surface.
For more information go to www.kramerav.com/downloads/VS-21DTP.
Mount the unit in a rack using an optional RK-3T rack adapter.
INPUT 1 is the default priority setup and is automatically switched to the
output.
INPUT 2 is the default priority setup and is automatically switched to the
output.
The last connected source is switched to the output (a reactivated or
reconnected source becomes the new “Last Connected” source).
Momentarily connect REMOTE IN 1 to PIN G (ground).
Momentarily connect REMOTE IN 2 to PIN G (ground).
There are no operator serviceable parts inside the unit.
Use only the power cord that is supplied with the unit.
Do not open the unit. High voltages can cause electrical shock! Servicing by qualified personnel only.
Disconnect the power and unplug the unit from the wall before installing.
See www.KramerAV.com for updated safety information.
Step 3: Install VS-21DTP
Step 4: Connect the inputs and outputs
Always switch OFF the power on each device before connecting it to your VS-21DTP. For best results, we recommend that you
always use Kramer high-performance cables to connect AV equipment to VS-21DTP.
DIP-switches Setup:
A switch that is down is on; a switch that is up is off. By default, both switches are up (off).
Video Switching Selection:
Contact Closure Switches (Manual Override):
Controlling via the remote contact closure pushbuttons overrides all DIP-switch settings and automatic switching until the manually
selected source disconnects, becomes inactive or the VS-21DTP is powered off.
Step 5: Connect the power
Connect the 48V DC power supply to VS-21DTP and plug it into the mains electricity or accept power over Ethernet (PoE) from an
HDBaseT receiver via PoE.
Safety Instructions