Kramer TOOLS 900xl User Manual

Page 1
Kramer Electronics, Ltd.
USER MANUAL
Model:
900xl
Power Amplifier
Page 2
Contents
i
Contents
1 Introduction 1 2 Getting Starte d 1
2.1 Recycling Kramer Products 1
2.2 Quick Start 2
3 Overview 3 4 Your 900xl Power Amplifier 4 5 Connecting the 900xl Power Amplifier 6
5.1 Connecting a PC 7
6 Operating the 900xl Power Amplifier 7
6.1 Using the Front Panel Buttons 7
6.2 Using Serial Commands 8
7 Technical Specifications 8 8 Hex Table 9 9 Kramer Protocol 2000 9
Figures
Figure 1: 900xl Power Amplifier – Top, Front, a nd Re a r Vie ws 4 Figure 2: 900xl Power Amplifier – Underside View
5
Figure 3: Connecting the 900xl Power Amplifier
6
Figure 4: RS-232 Control Cable 7
Tables
Table 1: 900xl Power Amplifier Front, and Rear Functions 4 Table 2: 900xl Power Amplifier Underside Functions
5
Table 3: 900xl Technical Specifications
8
Table 4: 900xl Hex Table 9 Table 5: Protocol Definitions
9
Table 6: Instruction Codes for Protocol 2000
10
Page 3
Introduction
1
1 Introduction
Welcome to Kramer Electronics! Since 1981, Kramer Electronics has been providing a world of unique, creative, and affordable solutions to the vast range of problems that confront the video, audio, presentation, and broadcasting professional on a daily basis. In recent years, we have redesigned and upgraded most of our line, making the best even better! Our 1,000-plus different models now appear in 11 groups
1
Thank yo u for purchasing the Kra mer TOOLS 900xl Power Amplifier, which is ideal for:
that are clearly
defined by function.
Presentation roo ms and multimedia applications for quick, local
audio amplification
Personal audio listening (for example, a PC and portable CD
player)
The package includes the following items:
900xl Power Amplifier
12V DC power supply
This user manual
2
2 Getting Started
We recommend that you:
Unpack t he equip ment carefully and s ave the original box and
packaging materials for possible future shipment
Review the contents of this user manual
Use Kramer high performance high-resolution cables
3
2.1 Recycling Kramer Products
The Waste Electrical and Electronic Equipment (WEEE) Directive 2002/96/EC aims to reduce the amount of WEEE sent for disposal to
1 GROUP 1: Distribution Amplifiers; GROUP 2: Switchers and Routers; GROUP 3: Control Systems; GROUP 4: Format/Standards Converters; GROUP 5: Range Extenders and Repeaters; GR OUP 6: Specialty AV Products; GROUP 7: Scan Converters and Scalers; GROUP 8: Cables and Connectors; GROUP 9: Room Connectivity; GROUP 10: Accessories and Rack Adapters; GROUP 11: Sierra Products 2 Download up-to-date Kramer user manuals from our Web site at http://www.kramerelectronics.com 3 The complete list of Kramer cables is on our Web site at http://www.kramerelectronics.com
Page 4
KRAMER: SIMPLE CREATIVE TECHNOLOGY
Getting Started
2
landfill or incineration by requiring it to be collec te d and recycled. To comply with the WEEE Directive, Kramer Electronics has made arrangements with the European Advanced R ecyclin g Network (EARN) and will cover any costs of treatment, recycling and recovery of waste Kramer Electronics branded equipment on arrival at the EARN facility. For details of Kramer’s recycling arrangements in your particular country go to our recycl ing pag es at
http://www.kramerelectronics.com/support/recycling/
.
2.2 Quick Start
This quick start chart summarizes the basic setup and operation steps.
Page 5
Overview
3
3 Overview
The Kramer 900xl is a high-performance power amplifier for line-level stereo audio signals. It accepts either a stereo audio signal on an RCA connector or a stereo audio signal on a 3.5mm mini jack. It delivers a speaker output of 10 watts RMS per channel into a 4Ω load on a 10A 4-pin terminal block connector.
The 900xl includes:
Input selector buttons
Audio gain buttons for volume control
Overheating warning protection with LED indicator
A 12V DC power adapter
The 900xl is house d in a Kramer TOOLS enclos ure. To achieve the best performance:
Use only good quality connection cables
1
Do not secure the cables in tight bundles or roll the slack int o tight
coils
to avoid interference, deterioration in signal q uality due to poor matching, and elevated noise levels (often associated with low quality cables)
Avoid interference from neighboring electrical appliances that
may adversely influence signal quality
Position your Kramer 900xl awa y from moisture, exc essive
sunlight and dust
1 Available from Kramer Electronics on our Web site at http://www.kramerelectronics.com
Page 6
KRAMER: SIMPLE CREATIVE TECHNOLOGY
Your 900xl Pow e r Amplifier
4
4 Your 900xl Power Amplifier
Figure 1 , Figure 2 , Table 1, and Table 2 define the unit.
Figure 1: 900xl Power Amplifier – Top, Front, and Rear Views
Table 1: 900xl Power Amplifier Front , an d Rear Functions
#
Feature
Function
1 12V DC Connector +12V DC for powering the unit 2 RS-232 Tx Rx G Terminal Block
Connector
Connect to PC
3 L+ L– R+ R– OUT Terminal
Block Connector
Speaker output
4 IN 2 RIGHT RCA Connector Connect to stereo audio right input of source 2 5 IN 2 LEFT RCA Connector Connect to stereo audio left input of source 2 6 IN 1 3.5mm Mini-jack Connector Connect to stereo audio input of source 1 7 INPUT 1 Button Selects the input from audio source 1 8 INPUT 2 Button Selects the input from audio source 2 9 VOLUME – Button Decreases output volume 10 VOLUME + Button Increases output volume 11 OVER LED Illuminates red when devic e is ove rh eat i ng and mutes output 12 ON LED Illuminates green when receiving power
Page 7
Your 900xl Pow e r Amplifier
5
Figure 2: 900xl Power Amplifier – Underside View
Table 2: 900xl Power Amplifier Underside Functions
# Feature Function
1 LEVEL L/H Switch Input level – low / high gai n; set to low in case of distortion 2 PROG ON Switch For use when upgrading device firmware
Page 8
KRAMER: SIMPLE CREATIVE TECHNOLOGY
Connecting the 900xl Powe r Am pli fier
6
5 Connecting the 900xl Power Amplifier
To connect the 900xl, as illustra te d in Figure 3 , perform the following:
1. Connect an un balan ce d s ter eo audio source (for example, a computer audio line out) to the IN 1 mini jack connector.
2. Connect an unbalanced stereo audio source (for exam pl e, an u n balan ce d stere o au di o play er ) to th e L EF T an d RIG H T IN 2 RCA connectors.
3. Connect the SPKR OUT terminal block to a p ai r of l ou ds pe ake rs : Connect the “L+” and the “L-” terminal block connectors to the left loudspeaker, and the “R+” and the “R-” terminal block connectors to the right loudspeaker. Do not ground the loudspeakers.
4. Connect the 12V DC power adapter to the power socket and connect the adapter to the mains electricity (not shown in
Figure 3).
Figure 3: Connecting the 900xl Power Amplifier
Page 9
Operating the 900xl Power Amplifier
7
5.1 Connecting a PC
You can control the 900xl with a PC (or other controllers) via the RS-232 port using serial commands.
To connect a PC to the 900xl:
Connect the RS-232 9-pin D-sub port on your PC to the RS-232
rear panel port on the Master 900xl using a cable as sho wn in
Figure 4 :
Figure 4: RS-232 Control Cable
6 Operating the 900xl Power Amplifier
You can operate your 900xl using:
The front panel but t ons
RS-232 serial commands transmitted by a PC, touch screen
system, or other serial controller
6.1 Using the Front Panel Buttons
To operate the 900xl using the front panel buttons:
To choo s e audio input source 1 (the PC line-out as shown i n
Figure 3 ), press INPUT 1 button.
To choo s e audio input sourc e 2 (a stereo tape), press INPUT 2
button.
Adjust the output volume to the speakers us ing the VOLUME + and – buttons.
Note: In the case of output disto rtion that cannot be correc te d using the volume controls, try switc hing the LEVEL switch on the und e r side of the unit (see
Figure 2 ) from H to L and alter the output using the vol ume
control.
Page 10
KRAMER: SIMPLE CREATIVE TECHNOLOGY
Technical Specifications
8
6.2 Using Serial Commands
To operate your device using serial commands, you need to install Kramer's control software
1
For an explanation of all control commands, see sections . 8
and 9.
7 Technical Specifications
900xl technical specifications are shown in Table 3:
Table 3: 900xl Technical Specifications
2
INPUTS:
1 unbalanced stereo audio on a 3.5mm mini-jack connector;
1 unbalanced stereo audio on RCA connectors OUTPUT: 1 stereo differential speaker output OUTPUT POWER: 2x10W (4Ω) INPUT SENSITIVITY: 460mV OUTPUT MUSIC POWER: 2x40W (4Ω) BANDWIDTH (-3dB): 25kHz S/N RATIO: 85dB @1kHz, 0dBu output CONTROLS: Gain range: -14 to +32dB at high-gain; -21 to +20dB at low-gain COUPLING: Input: AC; output: DC AUDIO THD + NOISE: 0.6% @0dBu output AUDIO 2nd HARMONIC: 0.35% @0dBu out put POWER SOURCE: 12V DC, 2.0A OPERATING
TEMPERATURE:
0° to +40°C (32° to 104°F)
STORAGE TEMPERATURE:
–45° to +72°C (–49° to 162°F)
HUMIDITY: 10% to 90%, RHL non-condensing DIMENSIONS: 12cm x 7.5cm x 2.5cm (4.7" x 3.0" x 1.0") W, D, H WEIGHT: 0.2kg (0.4lbs) approx. ACCESSORIES: Power supply OPTIONS: RK-3T 19" rack adapter
1 Download control software from our Web site at http://www.kramerelectronics.com 2 Specifications are subject to change without notice
Page 11
Hex Table
9
8 Hex Table
Table 4 lists the Hex values (described in sectio n 9) for the 900xl:
Table 4: 900xl Hex Table
Instruction # Hex Code Description
2. Switch Audio 02 81 81 81 Connect Input 1 to ou tput 02 82 81 81 Connect I nput 2 to ou tput
22. Gain Control
Output 1
16 81 80 81 Mute 16 81 81 81
16 81 82 81
16 81 FF 81 Maximum gain
24. Increase/Decrease
Audio Parameter
18 81 80 81 Increase output 18 81 81 81 Decrease output
9 Kramer Protocol 2000
The 900xl is compatible with Kramer’s Protocol 2000, version 0.50. This RS-232/RS-485 communication protocol uses four bytes of information as defined below. For RS-232, a null-modem connection between the machine and controller is used. The default data rate is 9600 baud, with no parity, 8 data bits, and 1 stop bit.
Note: Compatibility with Kramer ’s Protocol 2000 does not mean that a machine uses all of the commands below. Each machine uses a sub-set of Protocol 2000, according to its needs.
Table 5: Protocol Definitions
MSB
LSB
DESTINATION
INSTRUCTION
0 D N5
N4
N3
N2
N1
N0
7 6 5 4 3 2 1 0
1st byte
INPUT
1
I6
I5
I4
I3
I2
I1
I0
7 6 5 4 3 2 1
0
2nd byte
OUTPUT
1
O6
O5
O4
O3
O2
O1
O0 7 6 5 4 3 2 1 0
3rd byte
MACHINE NUMBER
1
OVR X M4
M3
M2
M1
M0 7 6 5 4 3 2 1 0
4th byte
Page 12
KRAMER: SIMPLE CREATIVE TECHNOLOGY
Kramer Protoc ol 2000
10
1st BYTE: Bit 7 – Defined as 0. D – “DESTINATION”: 0 - for sending information to the switchers (from the PC); 1 - for sending to the PC (from the switcher). N5…N0 – “INSTRUCTION” The function to be performed by the switcher (s) is defined by the INSTRUCTION (6 bits). Also, if a function is performed via the machine’s keyboard, then these bits are set with the INSTRUCTION NO. that was performed. The instruction codes are defined according to the table below (INSTRUCTION NO. is the value to be set for N5…N0).
2
nd
BYTE: Bit 7 – Defined as 1. I6…I0 – “INPUT”. When switching (i.e. instruction codes 1 and 2), the INPUT (7 bits) is set as the input number which is to be switched. Similarly, if switching is done via the machine’s front-panel, then these bits are set with the INPUT NUMBER which was switched. For other operations, these bits are defined according to the table.
3
rd
BYTE: Bit 7 – Defined as 1. O6…O0 – “OUTPUT”. When switching (ie. instruction codes 1 and 2), the OUTPUT (7 bits) is set as the output number which is to be switched. Similarly, if switching is done via the machine’s front-panel, then these bits are set with the OUTPUT NUMBER which was switched. For other operations, these bits are defined according to the table.
4
th
BYTE: Bit 7 – Defined as 1. Bit 5 – Don’t care. OVR – Machine number override. M4…M0 – MACHINE NUMBER. Used to address machines in a system via their
machine numbers.
For a single machine controlled via the serial port, always set M4…M0 = 1, and make sure that the machine itself is configured as MACHINE NUMBER = 1.
When several machines are controlled from a sin gle serial port, they are usually configured together with each machine having an individual machine number. If the OVR bit is set, then all machine numbers will accept (implement) the command, and the addressed machine will reply.
Table 6: Instruction Codes for Protocol 2000
Note: All values in the table are decimal, unless otherwise stated.
INSTRUCTION
DEFINITION FOR SPECIF IC I NST RUCTI ON
NOTE
#
DESCRIPTION
INPUT
OUTPUT
0
RESET MACHINE
0 0 1
2 SWITCH AUDIO Set equal to audio input
which is to be switched (0 = disconnect)
Set equal to audio output which is to be switched (0 = to all the outputs)
2
6 REQUEST STATUS OF AN
AUDIO OUTPUT
Set as SETUP # Equal to output number whose
status is reqd
4, 3
12
REQUEST VIDEO / AUDIO
TYPE SETTING
Set as SETUP #, or
set to 126 or 127 to request if machine has
this function
0 - for video
1 - for audio 2 - for VGA
3, 4, 6 22
SET AUDIO PARAMETER
Equal to output number
whose parameter is to be
set = 1
Set as parameter value
0–127
2, 11
24
INCREASE / DECREASE AUDIO
PARAMETER
Equal to output number
whose parameter is to be increased / decreased by 1
0 - increase output
1 - decrease output
24
25 REQUEST AUDIO PARAMETER Equal to output number
whose parameter is requested
0 6, 20, 24
57 SET AUTO-SAVE I3 - no save
I4 - auto-save
0 12, 2
61
IDENTIFY MACHINE
2 - audio machine name
4 - audio software version 6 - RS422 controller version 7 - remote control name 8 - remote software version 9 - Protocol 2000 revision
0 - Request first 4 digits
1 - Request first suffix
13
62 DEFINE MACHINE 1 - number of inputs
2 - number of outputs 3 - number of setups
2 - for audio
14
Page 13
Kramer Protoc ol 2000
11
NOTES on the above table:
NOTE 1 – When the master switcher is reset, (e.g. when it is turned on), the reset code is sent to the PC. If this code is sent to the switchers, it will reset according to the present power-down settings.
NOTE 2 – These are bi-directional definitions. That is, if the switcher receives the code, it will perform the instruction; and if the instruction is performed (due to a keystroke operation on the front panel), then these c odes are sent. For example, if th e HEX code 02 82 81 81 was sent from the PC, then the switcher (machine 3) w ill switch input 1 to output 1. If the user switched input 1 to output 1 via the front panel keypad, then the switcher will send HEX codes: 42 81 81 81 to the PC. When the PC sends one of the commands in this group to the switcher, then, if the instruction is valid, the switcher replies by sending to the PC the same four bytes that it was sent (except for the first byte, where the DESTINATION bit is set high).
NOTE 3 – SETUP # 0 is the pres ent setting. SETUP # 1 and higher are the settings saved in the switcher 's memory, (i.e. those used for Store and Recall).
NOTE 4 – The reply to a "RE QUEST" instruction is as follows: the same instruction and INPUT codes as were sent are returned, and the OUTPUT is assigned the value of the requested parameter.
NOTE 6 – If INPUT is set to 127 for these instructions, then, if the function is defined on this machine, it replie s with OUTPUT=1. If the function is not defined, then the machine replies with OUTPUT=0, or with an error (invalid instruction code).
If the INPUT is set to 126 for these instructions, then, if possible, the machine will return the current setting of this function, even for the case that the function is not defined.
NOTE 11 – For machines where the audio parameter is programmable.
NOTE 12 – Under normal conditions, the machine's present status is saved each time a change is made. The "power-down"
save (auto-save) may be disabled using this code. Note that whenever the machine is turned on, the auto-save function is set.
NOTE 13 – This is a request to identify the switcher/s in the system. If the OUTPUT is set as 0, and the INPUT is set as 1, 2, 5 or 7, the machine will send its name. The reply is the decimal value of the INPUT and OUTPUT.
If the request for identification is sent with the INPUT set as 3 or 4, the appropriate machine will send its software version number. Again, the reply would be the d ecimal value of the INPUT and OUTPUT - the INPUT representing the nu mber in front of the decimal point, and the O UTPUT representing the number after it. For example, for version 3.5, the reply to the request to send the version number would be (HEX codes): 7D 83 85 81 (i.e. 128dec+ 3dec for 2nd byte, 128dec+ 5dec for 3rd byte).
NOTE 14 – The number of inputs and outputs refers to the specific machine which is bein g addressed, not to the system. For example, if six 16X16 matrices are configured to make a 48X32 system (48 inputs, 32 outputs), the reply to the HEX code 3E 82 81 82 (i.e. request the number of outputs) would be HEX codes 7E 82 90 82 i.e. 16 outputs
Page 14
Page 15
Kramer Electronics, Ltd.
Web site: www.kramerelectronics.com
E-mail: info@kramerel.com
P/N: 2900-000344 REV 5
For the latest information on our products and a list of Kramer
distributors, visit our Web site:
www.kramerelectronics.com
where updates to this user manual may be found.
We welcome your questions, comments and feedback.
Caution
Safety Warning:
Disconnect the unit from the power supply before opening/servicing.
P/N:
2900-000344
Rev:
5
Loading...