KRAMER ELECTRONICS LTD.
USER MANUAL
MODEL:
TBUS -201xl
Pop-up Table Connection Bus

Contents
1 Introduction 1
2 Getting Started 2
2.1 Achieving the Best Performance 2
2.1 Recycling Kramer Products 3
3 Overview 4
4 Defining the TBUS-201xl 5
4.1 The TBUS-201xl Connecting Surface 6
4.2 Power Socket Options 7
5 Installing the TBUS-201xl 9
5.1 Cutting an Opening 9
5.2 Installing the Power Socket 11
5.3 Inserting the TBUS-201xl through the Cut-Out Opening 12
5.4 Connecting the Cables 12
6 Technical Specifications 13
Figures
Figure 1: TBUS-201xl Pop-up Table Connection Bus 4
Figure 2: Defining the Parts of the TBUS-201xl Pop-up Table Connection Bus 5
Figure 3: TBUS-201xl Connecting Surface 6
Figure 4: Cut out Dimensions (not to scale) 10
Figure 5: TBUS-201xl Universal Power Socket Housing 11
Figure 6: Power socket installed 11

TBUS-201xl - Introduction
1 Introduction
Welcome to Kramer Electronics! Since 1981, Kramer Electronics has been
providing a world of unique, creative, and affordable solutions to the vast range of
problems that confront video, audio, presentation, and broadcasting professionals
on a daily basis. In recent years, we have redesigned and upgraded most of our
line, making the best even better!
Our 1,000-plus different models now appear in 14 groups that are clearly defined
by function: GROUP 1: Distribution Amplifiers; GROUP 2: Switchers and Routers;
GROUP 3: Control Systems; GROUP 4: Format/Standards Converters; GROUP 5:
Range Extenders and Repeaters; GROUP 6: Specialty AV Products; GROUP 7:
Scan Converters and Scalers; GROUP 8: Cables and Connectors; GROUP 9:
Room Connectivity; GROUP 10: Accessories and Rack Adapters; GROUP 11:
Sierra Video Products; GROUP 12: Digital Signage; GROUP 13: Audio; and
GROUP 14: Collaboration.
Thank you for purchasing the Kramer TBUS-201xl Pop-up Table Connection Bus,
which is ideal for boardrooms, conference and training rooms!

TBUS-201xl - Getting Started
2 Getting Started
We recommend that you:
Unpack the equipment carefully and save the original box and packaging
materials for possible future shipment
Review the contents of this user manual
Go to http://www.kramerelectronics.com/support/product_downloads.asp
to check for up-to-date user manuals, application programs, and to check
if firmware upgrades are available (where appropriate).
2.1 Achieving the Best Performance
To achieve the best performance:
Use only good quality connection cables (we recommend Kramer high-
performance, high-resolution cables) to avoid interference, deterioration in
signal quality due to poor matching, and elevated noise levels (often
associated with low quality cables)
Do not secure the cables in tight bundles or roll the slack into tight coils
Avoid interference from neighboring electrical appliances that may adversely
influence signal quality
Position your Kramer TBUS-201xl away from moisture, excessive sunlight
and dust
This equipment is to be used only inside a building. It may only be
connected to other equipment that is installed inside a building.
Do not place heavy objects on top of the TBUS-201xl.

TBUS-201xl - Getting Started
2.1 Recycling Kramer Products
The Waste Electrical and Electronic Equipment (WEEE) Directive 2002/96/EC
aims to reduce the amount of WEEE sent for disposal to landfill or incineration by
requiring it to be collected and recycled. To comply with the WEEE Directive,
Kramer Electronics has made arrangements with the European Advanced
Recycling Network (EARN) and will cover any costs of treatment, recycling and
recovery of waste Kramer Electronics branded equipment on arrival at the EARN
facility. For details of Kramer’s recycling arrangements in your particular country
go to our recycling pages at http://www.kramerelectronics.com/support/recycling/.

3 Overview
The TBUS-201xl is a furniture-mounted pop-up connection bus that is easily
installed into a table or podium top. The TBUS-201xl interface enables you to
connect any equipment to systems installed in a room via the following passthrough connectors:
1 PC on a 15-pin HD connector
1 HDMI connector
1 stereo audio on a 3.5mm connector
1 Ethernet RJ-45 connector
When not in use, you can lower the TBUS-201xl flush into the table. The example
in Figure 1 shows the TBUS-201xl in a table or podium top with a universal power
socket.
Figure 1: TBUS-201xl Pop-up Table Connection Bus
In addition, the TBUS-201xl is:
Easily opened and closed by pressing down gently on the lid due to its tilting
angular construction, pneumatic lift and mechanical latching mechanism. It
can be raised (when in use) or lowered (when not in use)
Suitable for any of the following power sockets: for the USA, the UK,
Germany (the Europlug), Belgium-France, Switzerland, Italy, Australia,
Brazil, Israel, South Africa or “Universal” for use anywhere (see compatibility
restrictions in Section 4.2)
Order the power sockets separately from Kramer Electronics

TBUS-201xl - Defining the TBUS-201xl
4 Defining the TBUS-201xl
Figure 2: Defining the Parts of the TBUS-201xl Pop-up Table Connection Bus
Black anodized or brushed
anodized aluminum semiautomatic lid
Covers the connecting surface, leaving the table surface
neat and tidy
2
Fits over the table surface
Enables the closing and opening of the lid by slightly
pressing it

TBUS-201xl - Defining the TBUS-201xl
Mounting Clamp Slits (four
sets on each side)
Insert the mounting clamps to the slits when installing the
TBUS-201xl
To ensure soft tightening to the table underside
For securing the TBUS-201xl to the table
Locking Butterfly Nuts (2)
Tighten to lock the mounting butterfly screw
Mounting Butterfly Nuts (2)
Tighten to secure the unit to the table surface
Mounting Clamps (2 units)
Place in the clamp slits after inserting the enclosure into
the table – for securing the unit to the table surface
Secures the power cable so it does not accidently
disconnect when opening the lid
Enables automatic lifting and smooth closing of the lid
Power Socket Opening
Screw Holes (4)
For installing/replacing the power socket
4.1 The TBUS-201xl Connecting Surface
Figure 3 defines the connecting surface and includes the universal power socket
(sold separately) for illustration purposes only (note that although ‘TBUS-201’ is
printed on the panel, the name of the modular product is TBUS-201xl):
Figure 3: TBUS-201xl Connecting Surface
Connect to an HDMI source
Connect to a computer graphics source
Connects to an unbalanced stereo audio source

TBUS-201xl - Defining the TBUS-201xl
Connects to the PC or other Controller through computer
networking
Suitable for various power sockets (see Section 4.2)
Pops up when gently pressing the lid
4.2 Power Socket Options
A choice of power sockets is available for purchase in several versions, including
power sockets for the USA, Brazil, Germany (the Europlug), UK, Switzerland,
Belgium-France, Italy, South Africa, Israel and Australia. A “Universal” socket for
general use is also available (see the compatibility restrictions in the table below).
Note that the photos below are for illustration purposes only.
TS-201U (80-000043)
100-240V AC, 50/60Hz, 5A
Maximum 5A per power
outlet
Fully compatible with power plugs in the
UK, India, Italy and Denmark, as well as
with the 2-prong Europlug.
Partially compatible (if the polarity is
reversed) with plugs in China, Switzerland,
Israel and the USA. The universal socket
does not supply grounding to plugs in Central
Europe and France and so you should order
country specific sockets instead.
Not compatible with South African plugs.
TS-201US (80-000046)
100-125V AC, 50/60Hz, 5A
Maximum 5A per power
outlet
TS-201IT (80-000047)
100-240V AC, 50/60Hz, 5A
Maximum 5A per power
outlet
TS-201DE (80-000044)
100-240V AC, 50/60Hz, 5A
Maximum 5A per power
outlet
TS-201AU (80-000050)
100-240V AC, 50/60Hz, 5A
Maximum 5A per power
outlet
TS-201FR (80-000045)
100-240V AC, 50/60Hz, 5A
Maximum 5A per power
outlet
TS-201IL (80-000053)
100-240V AC, 50/60Hz, 5A
Maximum 5A per power
outlet

TBUS-201xl - Defining the TBUS-201xl
TS-201ZA (80-000052)
100-240V AC, 50/60Hz, 5A
Maximum 5A per power
outlet
TS-201BR (80-000051)
100-240V AC, 50/60Hz, 5A
Maximum 5A per power
outlet
TS-201CH (80-000049)
100-240V AC, 50/60Hz, 5A
Maximum 5A per power
outlet
TS-201GB (80-000048)
100-240V AC, 50/60Hz, 5A
Maximum 5A per power
outlet

TBUS-201xl - Installing the TBUS-201xl
5 Installing the TBUS-201xl
To install the TBUS-201xl perform the following steps:
1. Cut an opening in the table (see Section 5.1).
2. Install the power socket (see Section 5.2).
3. Insert the TBUS-201xl through the cut-out opening (see Section 5.3).
4. Connect the cables (see Section 5.4).
5.1 Cutting an Opening
The metal cutout template (supplied) defines the surface you have to cut out to
install your TBUS-201xl.
The thickness of the table should be 3in (76mm) or less.
To cut an opening in the table:
1. Before cutting the opening, confirm the dimensions of the cutout template
and make sure that they have not changed.
2. Place the included cut out template (that is included with your TBUS-201xl)
on the surface of the table exactly where you want to install the
TBUS-201xl.
3. Attach the template to the table with the included screws (if using the cut out
template).
4. Following the inside edge of the template, cut a hole in the table surface
with a sabre or keyhole saw according to the dimensions shown in Figure 4
(not to scale).

TBUS-201xl - Installing the TBUS-201xl
Figure 4: Cut out Dimensions (not to scale)
5. Unscrew and remove the template from the surface of the table and clean
the table surface.
Take care not to damage the table.
If needed, you can download a full-scale template from our Web site.
Kramer Electronics is not responsible for any damage caused to the
table.

TBUS-201xl - Installing the TBUS-201xl
5.2 Installing the Power Socket
Figure 5 shows an example of the Universal power socket housing which is one of
the optional power sockets for the TBUS-201xl, see Section 4.2.
Figure 5: TBUS-201xl Universal Power Socket Housing
To install the power socket:
1. Close the TBUS-201xl lid.
2. Carefully insert the power socket housing so that the power socket fits into
the power socket opening on the connecting surface and the four standoffs
fit the four screw holes on the TBUS-201xl.
When positioned correctly, the IEC socket faces downwards.
3. Screw the four screws included in the power socket kit into the designated
holes to fix the power socket housing in place (see Figure 6).
Figure 6: Power socket installed

TBUS-201xl - Installing the TBUS-201xl
4. Unscrew the power connector lock.
5. Connect the IEC power cord to the IEC socket.
6. Insert the power cord into the power connector lock and tighten the screw
(see Figure 2, item 12) to secure the power cable.
5.3 Inserting the TBUS-201xl through the Cut-Out Opening
To install the TBUS-201xl, do the following:
1. Carefully insert the unit into the prepared opening.
2. Take the support clamps under the table and place them into the support
clamp late slits at the desired height (on both the front and rear sides of the
unit).
3. Make sure that the upper outer rim is situated parallel to the edge of the
table.
4. Insert the mounting screws through the holes in the mounting clamps.
Tighten the mounting butterfly nuts to secure the unit to the table surface
and then lock with the mounting butterfly screw.
5.4 Connecting the Cables
1. Connect the appropriate cables from underneath.
2. Secure the cables.
Do not keep the cord too tight or too loose.
Once you have connected the unit to the mains power and connected the proper
cables, you may use the unit.

TBUS-201xl - Technical Specifications
6 Technical Specifications
1 HDMI connector, 1 Ethernet RJ-45 connector,
1 15-pin HD connector, 1 3.5mm mini jack
POWER SOURCE
(AC power limits):
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
Fully compatible with power plugs in the UK, India, Italy
and Denmark, as well as with the 2-prong Europlug.
Partially compatible (if the polarity is reversed) with
plugs in China, Switzerland, Israel and the USA. The
universal socket does not supply grounding to plugs in
Central Europe and France (you should order country
specific sockets instead).
Not compatible with South African plugs.
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
220V AC, 50/60Hz, 5A
Maximum 5A per power outlet
220V AC, 50/60Hz, 5A
Maximum 5A per power outlet
220V AC, 50/60Hz, 5A
Maximum 5A per power outlet
220V AC, 50/60Hz, 5A
Maximum 5A per power outlet
220V AC, 50/60Hz, 5A
Maximum 5A per power outlet
OPERATING TEMPERATURE RANGE:
+5 to +45 Deg. Centigrade
OPERATING HUMIDITY RANGE:
10 to 90% RHL, non-condensing
STORAGE TEMPERATURE RANGE:
5 to 95% RHL, non-condensing
Including the outer rim: 14.5cm x 13.2cm x 17.3cm
(5.71" x 5.2" x 6.81") W, D, H
Without the outer rim: 13.3cm x 12.0cm x 17.3cm (5.24"
x 4.72" x 6.81") W, D, H
0.85kg (1.87lbs) approx.
1.2kg (2.65lbs) approx. with mounting brackets
1.4 kg (3.1lbs) approx. packed product
Power socket kits, power cord
Specifications are subject to change without notice at http://www.kramerelectronics.com

For the latest information on our products and a list of Kramer distributors, visit
our Web site where updates to this user manual may be found.
We welcome your questions, comments, and feedback.
Web site: www.kramerelectronics.com
E-mail: info@kramerel.com
SAFETY WARNING
Disconnect the unit from the power
supply before opening and servicing