Kramer TBUS-1-KWC Users Guide

Page 1
USER MANUAL
MODEL:
TBUS-1-KWC
Table Connection Bus with Wireless Charging Spot
P/N: 2900-300503 Rev 10 www.KramerAV.com
Page 2
Page 3
TBUS-1-KWC – Contents
i
Contents
1 Introduction 1 2 Getting Started 2
2.1 Achieving the Best Performance 2
2.2 Recycling Kramer Products 3
3 Overview 4 4 Defining TBUS-1-KWC 5
4.1 TBUS-1-KWC Optional Inner Frames 7
4.2 TBUS-1-KWC Optional Inserts 8
4.3 Power Socket Options 9
4.4 Power Cord Options 11
5 Installing TBUS-1-KWC 12
5.1 Assembling the Inner Frame 12
5.2 Installing the Inner Frame 18
5.3 Cutting an Opening in the Table 18
5.4 Inserting TBUS-1-KWC through the Cutout Opening 19
5.5 Connecting the Cables 20
5.6 Inserting the Pass-through Cables 20
5.7 Adjusting the Height of the Inner Frame 21
6 Using TBUS-1-KWC 22 7 Using the Wireless Charger 23
7.1 Using the Wireless Charger Directly 23
7.2 Using the Wireless Charger with a Receiver 24
8 Technical Specifications 26
Figures
Figure 1: TBUS-1-KWC inside a Table 4 Figure 2: TBUS-1-KWC Table Connection Bus – Front View 5 Figure 3: TBUS-1-KWC – Rear View 6 Figure 4: TBUS-1-KWC Inner Frame (P/N: 80-000299) 13 Figure 5: Installing a Kramer TOOL 14 Figure 6: Installing the T-TBLANK TOOL Blank 15 Figure 7: T-RC8IR (P/N: 80-000599) 16 Figure 8: RC-8IR Faceplate Holes Table Connection Bus 17 Figure 9: Cutout Dimensions 18 Figure 10: Inserting TBUS-1-KWC into the Prepared Opening 20 Figure 11: Cable Pass-through Insert (P/N: 80-000499) 21 Figure 12: TBUS-1-KWC Boardroom Installation 22 Figure 13: KWC-MUSB Micro USB Receiver 24 Figure 14: KWC-LTN Lightning Receiver 24 Figure 15: Receiver Underside 24
Page 4
TBUS-1-KWC - Introduction
1

1 Introduction

Welcome to Kramer Electronics! Since 1981, Kramer Electronics has been providing a world of unique, creative, and affordable solutions to the vast range of problems that confront video, audio, presentation, and broadcasting professionals on a daily basis. In recent years, we have redesigned and upgraded most of our line, making the best even better!
Our 1,000-plus different models now appear in 14 groups that are clearly defined by function: GROUP 1: Distribution Amplifiers; GROUP 2: Switchers and Routers; GROUP 3: Control Systems; GROUP 4: Format/Standards Converters; GROUP 5: Range Extenders and Repeaters; GROUP 6: Specialty AV Products; GROUP 7: Scan Converters and Scalers; GROUP 8: Cables and Connectors; GROUP 9: Room Connectivity; GROUP 10: Accessories and Rack Adapters; GROUP 11: Sierra Video Products; GROUP 12: Digital Signage; GROUP 13: Audio; and GROUP 14: Collaboration.
Thank you for purchasing the Kramer TBUS-1-KWC Table Connection Bus featuring a charging spot, which is ideal for boardrooms, conference and training rooms!
Page 5
2
TBUS-1-KWC - Getting Started

2 Getting Started

We recommend that you:
Unpack the equipment carefully and save the original box and packaging
materials for possible future shipment.
Review the contents of this user manual.
Go to www.kramerav.com/downloads/TBUS-1-KWC to check for up-to- date user manuals, application programs, and to check if firmware upgrades are available (where appropriate).

2.1 Achieving the Best Performance

To achieve the best performance:
Use only good quality connection cables (we recommend Kramer high-
performance, high-resolution cables) to avoid interference, deterioration in signal quality due to poor matching, and elevated noise levels (often associated with low quality cables).
Do not secure the cables in tight bundles or roll the slack into tight coils.
Avoid interference from neighboring electrical appliances that may adversely
influence signal quality.
Position your Kramer TBUS-1-KWC away from moisture, excessive sunlight
and dust.
This equipment is to be used only inside a building. It may only be connected to other equipment that is installed inside a building.
Do not place heavy objects on top of TBUS-1-KWC.
Page 6
TBUS-1-KWC - Getting Started
3

2.2 Recycling Kramer Products

The Waste Electrical and Electronic Equipment (WEEE) Directive 2002/96/EC aims to reduce the amount of WEEE sent for disposal to landfill or incineration by requiring it to be collected and recycled. To comply with the WEEE Directive, Kramer Electronics has made arrangements with the European Advanced Recycling Network (EARN) and will cover any costs of treatment, recycling and recovery of waste Kramer Electronics branded equipment on arrival at the EARN facility. For details of Kramer’s recycling arrangements in your particular country go to our recycling pages at www.kramerav.com/support/recycling/.
Page 7
4
TBUS-1-KWC - Overview

3 Overview

TBUS-1-KWC is a modular furniture-mounted connection bus enclosure that is
easily installed into a table or podium top. Once assembled, TBUS-1-KWC lets you connect any equipment to the room’s
presentation system installations via cable access or passive interfaces (see Figure 1). When the cables are not in use, they can be stored inside the unit, covered by the lid and out of sight.
TBUS-1-KWC features a built-in Qi standard compliant charging spot that enables you to charge your mobile device by simply placing it on the charging spot.
If your mobile device does not support wireless charging, you can connect it to a Kramer wireless charging receiver (sold separately) and then place it on the charging spot.
In addition, TBUS-1-KWC features:
A modular design, letting you tailor TBUS-1-KWC according to your
requirements.
Black or clear sandblast finish, anodized aluminum lid.
Special openings for cable pass-through.
Height adjustment screw holes to set the inner frame (ordered separately) to
the desired height.
Single or dual power socket openings that are suitable for any of the following
power sockets: for the USA, the UK, Switzerland, Germany (the Europlug), Belgium-France, Italy, Australia, Israel, Brazil, South Africa or “Universal” for use anywhere (see compatibility restrictions in Section 8).
Order the power sockets separately from Kramer Electronics
Figure 1: TBUS-1-KWC inside a Table
Page 8
TBUS-1-KWC - Defining TBUS-1-KWC
5

4 Defining TBUS-1-KWC

This section defines TBUS-1-KWC.
Figure 2: TBUS-1-KWC Table Connection Bus – Front View
#
Feature
Function
1
Black/Clear Anodized Sandblast Textured Lid
Includes an opening for cable pass-through; covers the inner frame, leaving the table surface neat and tidy.
2
Charging Spot
For mobile device wireless charging
3
Outer Rim
Fits over the table surface. A protective rubber guard protects the outer rim during shipping. Remove it before installing the unit.
4
Enclosure
Inserted into the table cutout
5
Tie Holes
Insert the self-locking tie through the holes to fix the pass­through cables to the inside walls of the unit.
6
Bracket Grooves
For attaching the two mounting brackets on opposite sides.
7
TOOL Height Adjustment Screw Holes
Used for installing Kramer TOOLs.
Page 9
6
TBUS-1-KWC - Defining TBUS-1-KWC
#
Feature
Function
8
Table Clamping Set
Mounting Brackets (2 units)
Place in the bracket slits after inserting the enclosure into the table – for securing the unit to the table surface (one for each clamp)
9
Mounting Butterfly Screws
Tighten to secure the unit to the table surface (one for each clamp)
10
Locking Butterfly Screws
Tighten to lock the mounting butterfly screw (one for each clamp)
11
Rubber Protectors
Protect the table surface when mounting the unit and ensure soft tightening to the table underside (one for each clamp)
12
Inner Frame Height Adjustment Screw Holes
For adjusting the height of the mounted inner frame 13
Power Spot Wiring
Connect to a power source (see Figure 3)
Figure 3: TBUS-1-KWC – Rear View
Page 10
TBUS-1-KWC - Defining TBUS-1-KWC
7

4.1 TBUS-1-KWC Optional Inner Frames

The following inner frames can be installed in the TBUS-1-KWC enclosure:
Inner Frames for TBUS-1A
Specifications
T1AF-16 (P/N: 80-000299)
1 opening for 1 power socket 2 cable pass-through inserts 4 blank inserts
T1AF-26 (P/N: 80-000399)
1 opening for 2 power sockets 2 cable pass-through inserts 4 blank inserts
T1AF-44 (P/N: 80-000499)
2 openings for 4 power sockets 2 cable pass-through inserts 2 blank inserts
T1AF-14L (P/N: 80-000699)
1 opening for 1 power socket 1 opening for Kramer SI-1VGA / RC-3TB 2 cable pass-through inserts 2 blank inserts
Page 11
8
TBUS-1-KWC - Defining TBUS-1-KWC
Inner Frames for TBUS-1A
Specifications
T1AF-1T3 (P/N: 80-005199)
1 opening for 1 power socket 2 openings for 3 Kramer TOOLs
T1AF-14T (P/N: 80-005299)
1 opening for 1 power socket 1 opening for 1 Kramer TOOL 2 cable pass-through inserts 2 blank inserts
Custom made inner frames can be designed if required. Contact Kramer Electronics for more details.

4.2 TBUS-1-KWC Optional Inserts

Accessories
Description
Inserts
You can install any wall plate devices as well as any of the single or dual insertssee our Web site for details.
T-RC8IR (P/N: 80-000599)
1 special panel to fit the Kramer RC-8IR Control Panel into the appropriate frame (P/N 80-000399 or P/N 80-000499 instead of two power sockets)
T-4INSERT (P/N: 60-100199)
The T-4INSERT kit can be installed inside a dual power socket opening and includes:
2 single cable pass-through insert 2 dual cable pass-through insert
T-2INSERT (P/N: 80-00006699)
The T-2INSERT kit can be installed inside a single power socket opening and includes:
1 single cable pass-through insert 1 dual cable pass-through insert
Page 12
TBUS-1-KWC - Defining TBUS-1-KWC
9
Accessories
Description
T-TBLANK (P/N: 80-005099)
This TOOL blank covers a TOOL opening for the T1AF-1T3 (P/N: 80-005199) and T1AF-14T (P/N: 80-
005299) inner frames

4.3 Power Socket Options

Inner frames support installing one or more of the following power socket assemblies. Note: The Brazilian power sockets are supplied as dual power sockets in a single power socket assembly (see table below).

4.3.1 Single Power Socket Assemblies

Power Socket Type
Power Specs
Power Socket Type
Power Specs
Universal:
TS-1U (80-000899)
100-240V AC, 50/60Hz, 5A Maximum 5A per power outlet
Fully compatible with power plugs in the UK, India, Italy and Denmark, as well as with the 2-prong Europlug. Partially compatible (if the polarity is reversed) with plugs in China, Switzerland, Israel and the USA. The universal socket does not supply grounding to plugs in Central Europe and France and so you should order country specific sockets instead.
Not compatible with South African plugs.
Power Socket Type
Power Specs
Power Socket Type
Power Specs
USA:
TS-1US (80-000999)
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
UK TS-1UK (91-000022)
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
Belgium and France:
TS-1FR (80-001399)
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
Israel:
TS-1IL (80-001799)
220V AC, 50/60Hz, 5A
Maximum 5A per power outlet
Germany and EU:
TS-1DE (80-001299)
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
South Africa
TS-1ZA (80-001699)
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
Page 13
10
TBUS-1-KWC - Defining TBUS-1-KWC
Power Socket Type
Power Specs
Power Socket Type
Power Specs
Italy: TS-1IT (80-001499)
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
Australia:
TS-1AU (80-001599)
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
Switzerland
TS-1CH (80-000027)
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
Brazil TS-BR (80-000034)
100-240V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet

4.3.2 Dual Power Socket Assemblies

Dual Power Socket Assemblies:
Power Specs
Universal:
TS-2U (80-001899)
100-240V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
USA: TS-2US (80-001999)
100-240V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
Belgium and France:
TS-2FR (80-002299)
100-240V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
Germany and EU:
TS-2DE (80-002199)
100-240V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
Italy TS-2IT (80-002399)
100-240V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
Switzerland
TS-2CH (80-000026)
220V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
Page 14
TBUS-1-KWC - Defining TBUS-1-KWC
11
Dual Power Socket Assemblies:
Power Specs
UK TS-1UK (91-000023)
220V AC, 50/60Hz, 5A Maximum 5A/2.5A per power outlet
Israel:
TS-2IL (80-002699)
220V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
South Africa:
TS-2ZA (80-002599)
220V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
Australia:
TS-2AU (80-002499)
100-240V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet

4.4 Power Cord Options

You can order any of the following power cords to use with a modular TBUS:
Power Cord Type
Description
P/N
6ft/110V (North America)
C-AC/US (110V)
91-000099
6ft/125V (Japan)
C-AC/JP (125V)
91-000699
6ft/220V (Europe)
C-AC/EU (220V)
91-000199
6ft/220V (Israel)
C-AC/IL (220V)
91-000999
6ft/250V (UK)
C-AC/UK (250V)
91-000299
6ft/250V (India)
C-AC/IN (250V)
91-001099
6ft/250V/10A (China)
C-AC/CN (250V)
91-001199
6ft/250V/10A (South Africa)
C-AC/ZA (250V)
91-001299
To use one power cord for a 4-socket configuration, you can order any of the following types of power cords separately:
Power Cord Type
Description
P/N
110V Y-version (6ft), North America
C-ACY/US
91-000399
220V Y-version (6ft), Europe
C-ACY/EU
91-000499
240V Y-version (6ft), UK
C-ACY/UK
91-000599
Page 15
12
TBUS-1-KWC - Installing TBUS-1-KWC

5 Installing TBUS-1-KWC

To install TBUS-1-KWC:
1. Assemble the inner frame (see Section 5.1).
2. Install the inner frame (see Section 5.2).
3. Cut an opening in the table (see Section 5.3).
4. Insert the unit through the opening and secure it to the table (see Section 5.4).
5. Connect the cables (see Section 5.5).
6. Insert the pass-through cables (see Section 5.6).
7. Adjust the height of the inner frame (see Section 5.7).

5.1 Assembling the Inner Frame

The modules mounted on the inner frame can include single inserts and/or dual inserts as well as power sockets and various Kramer devices. This section describes how to assemble these modules.
Each module kit is supplied with detailed assembly instructions.

5.1.1 Mounting the Inserts

You can rearrange or remove any of the plates mounted on the inner frame and replace them with Kramer passive wall plates or connector modules for interfacing A/V type signals.
To mount a Kramer insert or connector module:
1. Unscrew the two screws that fasten the blank plate to the inner frame and
remove the blank plate.
Page 16
TBUS-1-KWC - Installing TBUS-1-KWC
13
2. Place the required Kramer insert over the opening, insert the two screws to fix
the Kramer insert in place, and tighten them.
Figure 4: TBUS-1-KWC Inner Frame (P/N: 80-000299)
#
Feature
Function
1
Split Brackets
Support the split grommet for the pass through-cables
2
Split Grommets
Push apart slightly to insert cables
3
Blank Plates
Four blank covers that can be replaced with wall plates as required
4
Power Socket Opening
Suitable for a single power socket or the T-2INSERT
5
Adjustable Height Screw Holes
For adjusting the height of the inner frame

5.1.2 Mounting the Power Socket Assemblies

To mount the power socket, place the power socket under the frame in its appropriate place and tighten with the two screws (supplied).
Power socket kits are supplied with assembly instructions.
Page 17
14
TBUS-1-KWC - Installing TBUS-1-KWC

5.1.3 Mounting a Kramer TOOL

To mount a TOOL (for example, to the T1AF-14T), as shown in Figure 5:
1. Screw the spacers to their designated places (one on each side).
2. Insert the TOOL, from beneath, through the TOOL opening.
3. Screw the screws (one on each side) through the frame holes and spacers.
Figure 5: Installing a Kramer TOOL
Page 18
TBUS-1-KWC - Installing TBUS-1-KWC
15

5.1.4 Installing the TOOL Blank

To install the T-TBLANK, as shown in Figure 6:
1. Insert the T-TBLANK from beneath, through the TOOL opening.
2. Screw the screws (one on each side) through the frame.
Figure 6: Installing the T-TBLANK TOOL Blank
Page 19
16
TBUS-1-KWC - Installing TBUS-1-KWC

5.1.5 Mounting the Special Panel for RC-8IR

The Kramer T-RC8IR for TBUS-1-KWC Table Connection bus is used to fit the Kramer RC-8IR Control Panel into the appropriate frame (P/N 80-000399 or P/N 80-000499 instead of two power sockets).
Figure 7: T-RC8IR (P/N: 80-000599)
Page 20
TBUS-1-KWC - Installing TBUS-1-KWC
17
To replace the RC-8IR faceplate:
1. Unscrew the two faceplate attachment screws and remove the RC-8IR
faceplate before installing the T-RC8IR.
Figure 8: RC-8IR Faceplate Holes Table Connection Bus
2. Place the T-RC8IR over the RC-8IR enclosure so that both face plate holes
are aligned with the face plate holes on the RC-8IR enclosure and the IR IN receiver fits into the IR IN opening.
3. Insert the faceplate screws through the T-RC8IR and RC-8IR enclosure
faceplate holes, and tighten.
To install the T-RC8IR:
1. Insert the T-RC8IR assembly through the dual power socket opening from beneath.
2. Use the two power socket screws to tighten the T-RC8IR assembly in place.

5.1.6 Installing the SI-1VGA / RC-3TB

To install the SI-1VGA / RC-3TB module, place it under the designated opening in the T1AF-14L (P/N: 80-000699) and then screw and tighten it in place using the two screws supplied with the inner frame.
Page 21
18
TBUS-1-KWC - Installing TBUS-1-KWC

5.2 Installing the Inner Frame

To install the inner frame:
1. Place the inner frame inside the TBUS-1-KWC enclosure.
2. Set the required height using your fingers to bring the inner frame to the desired position, screw and tighten it in place using the height adjustment screws (supplied with the inner frame).
Inner frame kits come with assembly instructions.

5.3 Cutting an Opening in the Table

To cut an opening in the table:
1. Place the included cutout template (that is included with your TBUS-1-KWC)
on the surface of the table exactly where you want to install the TBUS-1-KWC.
2. Attach the template to the table with the included screws (if using the cutout
template).
3. Following the inside edge of the template, cut a hole in the table surface with
a sabre or keyhole saw according to the dimensions shown in Figure 9 (not to scale).
The thickness of the table should be 76 mm / 3 inches or less.
Figure 9: Cutout Dimensions
Page 22
TBUS-1-KWC - Installing TBUS-1-KWC
19
4. Unscrew and remove the template from the surface of the table and clean the table surface. Take care not to damage the table. If needed, you can download a full-scale template from our Web site.
Kramer Electronics is not responsible for any damage caused to the table.

5.4 Inserting TBUS-1-KWC through the Cutout Opening

To install TBUS-1-KWC in the opening:
1. Remove the protective rubber guard from around the outer rim of the TBUS-1-KWC housing. Beware of the sharp edge!
2. Carefully insert the unit into the prepared opening (see Figure 10).
3. Attach the power supply under the table using the power supply bracket (supplied with the package).
4. Take the support brackets under the table and place them into the support bracket grooves on both sides of the unit (see Figure 2, item 6).
5. Verify proper alignment of the unit before tightening the mounting screws.
6. Tighten both mounting butterfly screws upward until they reach the table surface (from underneath). Tighten firmly (see Figure 10).
Page 23
20
TBUS-1-KWC - Installing TBUS-1-KWC
7. Tighten the locking butterfly screws downward until tight against the mounting bracket.
Figure 10: Inserting TBUS-1-KWC into the Prepared Opening

5.5 Connecting the Cables

Connect the Charging spot to the power supply and the power supply to the mains electricity (the power cord is purchased separately, see Section 4.3).
To connect the cables when replacing blank inserts with connector inserts (for example, VGA, audio, HDMI and so on):
1. Insert the cables to their appropriate connectors from underneath.
2. Secure the cables to the tie holes on TBUS-1-KWC. Do not secure the cables too tightly or too loosely. Leave a small amount of slack.

5.6 Inserting the Pass-through Cables

To insert the pass through cables (for example, to connect a laptop):
1. Remove the two screws attaching the split pass-through bracket.
2. Remove the split grommet.
3. Insert the cable through the rectangular opening.
Page 24
TBUS-1-KWC - Installing TBUS-1-KWC
21
4. Open the split grommet slightly and insert the required cables.
5. Place the split bracket around the grommet and position this assembly over the inner frame.
6. Place the two screws appropriately and tighten the split bracket together with the grommet and inserted cables to the inner frame.
7. Insert the self-locking ties through the tie holes to secure the cables to the inside walls of the enclosure.
Figure 11: Cable Pass-through Insert (P/N: 80-000499)

5.7 Adjusting the Height of the Inner Frame

If needed, you can adjust the inner frame height to accommodate large or bulky cables.
To adjust the inner frame height:
1. Remove the height adjustment screws, while supporting the surface from underneath with your fingers.
2. Raise or lower the inner frame to the required height, insert the screws, and tighten them in place.
Page 25
22
TBUS-1-KWC - Using TBUS-1-KWC

6 Using TBUS-1-KWC

Once TBUS-1-KWC is installed, you can easily customize it to suit your own requirements by plugging in the required A/V equipment, as illustrated in the example in Figure 12.
Figure 12: TBUS-1-KWC Boardroom Installation
Page 26
TBUS-1-KWC - Using the Wireless Charger
23

7 Using the Wireless Charger

The wireless charger can be used in one of the following ways:
Using the Wireless Charger Directly see section 7.1
Using the Wireless Charger with a Receiver see section 7.2

7.1 Using the Wireless Charger Directly

If your mobile device supports wireless charging, you can charge it directly on top of the charging spot.
You can charge only one mobile device at a time.
To use the wireless charger directly:
1. Make sure that the charging spot power cable is connected.
2. Place it on the charging spot until it is fully charged.
Page 27
24
TBUS-1-KWC - Using the Wireless Charger

7.2 Using the Wireless Charger with a Receiver

You can charge only one mobile device at a time.
When charging a mobile device, do not place any metal or magnetic objects over the receiver.
Charging a mobile device using the receiver in the vicinity of pacemakers, hearing aids, or similar medical electronic devices may interfere with the function of these devices.
Make sure the receivers are used in a cool and well-ventilated environment and away from flammable and explosive objects.
Avoid using the receivers in extreme temperatures or high humidity.
Kramer KWC-MUSB and KWC-LTN wireless charging receivers (sold separately) can be used with Kramer Wireless Charging (KWC) products for mobile devices that DO NOT have a built-in wireless charging receiver.
The KWC-MUSB Micro USB receiver (Figure 13) and KWC-LTN lightning receiver (Figure 14) are wireless power receivers that utilize electromagnetic induction to charge mobile devices wirelessly and are compatible with the Qi standard for wireless chargers (with security eyeholes).
Figure 13: KWC-MUSB
Micro USB Receiver
Figure 14: KWC-LTN
Lightning Receiver
Figure 15: Receiver
Underside
Page 28
TBUS-1-KWC - Using the Wireless Charger
25
To use the wireless charger with a receiver:
1. Connect your mobile device to either a KWC-MUSB Micro USB receiver or a KWC-LTN lightning receiver, as required.
2. Place the mobile device with the attached receiver centered on the charging spot (correct side facing the charging spot, see Figure 15) until it is fully charged.
Page 29
26
TBUS-1-KWC - Technical Specifications

8 Technical Specifications

POWER SOURCE (AC power limits):
Single Socket Assemblies:
Universal
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
Fully compatible with power plugs in the UK, India, Italy and Denmark, as well as with the 2-prong Europlug. Partially compatible (if the polarity is reversed) with plugs in China, Switzerland, Israel and the USA. The universal socket does not supply grounding to plugs in Central Europe and France (you should order country specific sockets instead). Not compatible with South African plugs.
USA
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
Germany and EU
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
Belgium and France
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
Italy
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
Australia
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
Israel
220V AC, 50/60Hz, 5A
Maximum 5A per power outlet
South Africa
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
Switzerland
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
UK
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
Brazil
100-240V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
Dual Power Kit Assemblies:
Universal
100-240V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
USA
100-240V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
Belgium and France
100-240V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
Germany and EU
100-240V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
Italy
100-240V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
Israel
220V AC, 50/60Hz, 5A
Maximum 5A/2.5A per power outlet
Switzerland
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
UK
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
Australia
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
South Africa
100-240V AC, 50/60Hz, 5A
Maximum 5A per power outlet
FUSE RATING:
T 6.3A 250V
Page 30
TBUS-1-KWC - Technical Specifications
27
POWER CONSUMPTION:
Charging spot: 12V DC, 1.25A
CHARGING EFFICIENCY:
73%
CHARGING POWER OUTPUT:
900 mA Max
SAFETY REGULATORY COMPLIANCE:
CE compliant
STANDARD:
Qi
OPERATING TEMPERATURE RANGE:
+5 to +45 Deg. Centigrade
OPERATING HUMIDITY RANGE:
10 to 90% RHL, non-condensing
STORAGE TEMPERATURE RANGE:
-20 to +70 Deg. Centigrade
STORAGE HUMIDITY RANGE:
5 to 95% RHL, non-condensing
DIMENSIONS:
22.1cm x 18.2cm x 13cm (8.17" x 5.88" x 5.13") W, D, H
WEIGHT:
Gross weight: 2.3kg (5.07lbs) approx.
TBUS-1-KWC with table clamps: 1.75kg (3.6lbs) approx.; Metal
template: 0.125kg (0.28lbs) approx.
ACCESSORIES:
Six self-locking ties, metal template, power supply, power supply bracket
OPTIONS:
Power cord, inner frames, passive wall plates and interfaces, power socket kits
Specifications are subject to change without notice at www.kramerav.com
Page 31
Page 32
P/N:
2900-300503
Rev:
10
SAFETY WARNING
Disconnect the unit from the power supply before opening and servicing
For the latest information on our products and a list of Kramer distributors, visit our Web site where updates to this user manual may be found.
We welcome your questions, comments, and feedback.
The terms HDMI, HDMI High-Definition Multimedia Interface, and the HDMI Logo are trademarks or registered trademarks of HDMI Licensing Administrator, Inc. All brand names, product names, and trademarks are the property of their respective owners.
www.KramerAV.com info@KramerAV.com
Loading...