The Kramer RC-5B2 and RC-5B4 Dual Inserts
This user manual is written for the end user. Refer to the separate K-CONFIG
Configuration Guide (available online) for details of how to install and configure the
Room Controller. The guide provides information about how to set up the system
and is updated on a regular basis. For the latest online guide, go to
http://www.kramerelectronics.com/support/?soft=k-config
Figure 1: RC-5B2 and RC-5B4 Front Panel
Figure 2: RC-5B2 and RC-5B4 Rear Panel
Two/four programmable, backlit buttons
For installing the insert
Connect to a computer for firmware upgrade
and for assigning a K-Net ID number
When the unit is connected via K-NET to a Master Room Controller,
you can upgrade the firmware via the USB or ETH ports of the Master
Room Controller
Connect to grounding wire
For factory use (internal switch)
Switch to ON for K-NET line
termination (internal switch)
Connect each terminal to the relevant one
on the Master K-Net unit or to another
AUX unit.
Figure 3: Grounding Connection Components
Congratulations on purchasing your Kramer RC-5B2 and RC-5B4 dual inserts with RGB buttons,
which can be used as auxiliary controllers when connected via K-NET™ to a Master room controller
(for example, the SV-552 SummitView™ Processor / Switcher or one of the Kramer SL series
controllers).
K-NET is a proprietary Kramer protocol for communication between Kramer products.
The RC-5B2 and RC-5B4 packages include labels (P/N: 2808-300008) that are used as light
diffusers and therefore need to be inserted inside each button (even to “blank” buttons).
Defining the RC-5B2 and RC-5B4 Dual Inserts
The RC-5B2 and RC-5B4 dual inserts feature:
Front panel, RGB backlit buttons: two for the RC-5B2 and four for the RC-5B4
7 colors are available for backlit buttons (to be configured by the system integrator).
Two K-NET ports and a USB serial port for setting the K-Net ID and for firmware upgrade
The RC-5B2 and RC-5B4 do not require a separate power supply.
Mounting the Kramer Insert
To mount a Kramer insert or connector module:
1. Place the Kramer insert over the opening.
2. Insert the four screws (two on each side) to fix the Kramer insert in place, and tighten them.
Grounding the RC-5B2 and RC-5B4
The grounding screw is used to earth the chassis of the unit to the ground of the building preventing
static electricity from impacting on the performance of the unit.
To ground the RC-5B2 and RC-5B4:
1. Connect the Ring Tongue terminal to the building grounding point wire (it is recommended to
use a green-yellow AWG#18 (0.82mm2) wire, crimped with a proper hand-tool).
2. Insert the M3x6 screw through the toothed lock washers and the tongue terminal in the order
shown above.
3. Insert the M3x6 screw (with the two toothed lock washers and ring tongue terminal) into the
grounding screw hole and tighten the screw.
To install the button caps and labels:
1. Unscrew the two faceplate screws and remove the faceplate.
2. Remove the button cap.
3. Remove the required labels from the supplied button label sheet.
4. Hold the button cap so that it is oriented as shown in Figure 4 with the “wings” on the left and
right sides.
5. Insert the label inside the cap
Overview
The RC-5B2 and RC-5B4 dual inserts are auxiliary remote control panels for Master Room
Controllers for control of A/V equipment in a room.
Figure 4: Button Cap Orientation Before and After the Insertion of a Label
6. Repeat for all caps.

7. Retaining the orientation, place the button caps on the
buttons of the RC-5B2 / RC-5B4.
8. Place the faceplate on the RC-5B2 / RC-5B4 so that the two
screw mounting holes are aligned.
9. Insert the two mounting screws and tighten with a
screwdriver.
Figure 5: Placing the
Button Cap
Using the RC-5B2 and RC-5B4 K-NET Auxiliary Control Panel
2 K-NET on terminal block connectors; 1 USB for programming
0° to +55°C (32° to 131°F)
-45° to +72°C (-49° to 162°F)
10% to 90%, RHL non-condensing
5cm x 2.4cm x 4.7cm (1.97" x 0.94" 1.85") W, D, H.
Specifications are subject to change without notice
Go to our Web site at http://www.kramerelectronics.com to access the list of resolutions
KR AM E R EL EC TR ON IC S L TD .
Installation
Instructions
MODELS:
RC-5B2 Dual Insert
K-NET™ Auxiliary Control Panel
RC-5B4 Dual Insert
K−NET™ Auxiliary Control Panel
For the latest information on our products and a list of Kramer
distributors, visit our Web site where updates to these
installation instructions may be found.
We welcome your questions, comments, and feedback.
Web site: www.kramerelectronics.com
E-mail: info@kramerel.com
SAFETY WARNING
Disconnect the unit from the power
supply before opening and servicing
The installation process is not detailed in this user manual. This user manual is applicable once the
unit is installed and configured (by authorized Kramer technical personnel or by an external system
integrator), and includes:
Setting up the labels on the buttons, according to your specific requirements
Configuration of the Master room controller via the K-Config Windows®-based configuration
software
Since the auxiliary panel is used as a remote controller for Master Room Controllers via the
proprietary communication channel K-NET (as illustrated in Figure 6):
It requires only a K-NET connection to the Master Room controller
A power supply unit is not required
The auxiliary panel can be programmed only via the Master Room controller (for example, the
Kramer SV-551 SummitView™ Processor/Switcher)
Figure 6: connected to the SV-551 SummitView™ Processor / Switcher
Technical Specifications