Kramer PT-12 User Manual

Page 1
P/N: 2900-301020 Rev 1 www.kramerAV.com
USER MANUAL
PT-12 HDMI Controller
Page 2
Kramer Electronics Ltd.
PT-12 – Contents
i
Contents
Introduction 1
Getting Started 1 Overview 2 Typical Applications 3
Defining PT-12 HDMI Controller 4 Mounting PT-12 5 Connecting PT-12 6 Configuring PT-12 7
Configuring Using DIP-Switches 7 Configuring Automatic Power Controls 8 Defining EDID Lock 8 Modifying EDID with EDID Designer 9 Defining Color Depth and Spacing 9 Defining Audio Pass-Through 9 Setting HDCP Operation 10
Upgrading Firmware 10 Technical Specifications 11 Default EDID 12 Protocol 3000 14
Understanding Protocol 3000 14 Protocol 3000 Commands 15 Result and Error Codes 19
Page 3
Kramer Electronics Ltd.
PT-12 – Introduction
1

Introduction

Welcome to Kramer Electronics! Since 1981, Kramer Electronics has been providing a world of unique, creative, and affordable solutions to the vast range of problems that confront the video, audio, presentation, and broadcasting professional on a daily basis. In recent years, we have redesigned and upgraded most of our line, making the best even better!

Getting Started

We recommend that you:
Unpack the equipment carefully and save the original box and packaging materials for possible future shipment.
Review the contents of this user manual.
Go to www.kramerav.com/downloads/PT-12 to check for up-to-date user manuals, application programs, and to check if firmware upgrades are available (where appropriate).

Achieving Best Performance

Use only good quality connection cables (we recommend Kramer high­performance, high-resolution cables) to avoid interference, deterioration in signal quality due to poor matching, and elevated noise levels (often associated with low quality cables).
Do not secure the cables in tight bundles or roll the slack into tight coils.
Avoid interference from neighboring electrical appliances that may adversely
influence signal quality.
Position your Kramer PT-12 away from moisture, excessive sunlight and dust.

Safety Instructions

Caution:
This equipment is to be used only inside a building. It may only be connected to other equipment that is installed inside a building.
For products with relay terminals and GPI\O ports, please refer to the permitted rating for an external connection, located next to the terminal or in the User Manual.
There are no operator serviceable parts inside the unit.
Warning:
Use only the power cord that is supplied with the unit.
To ensure continuous risk protection, replace fuses only according to the rating
specified on the product label which located on the bottom of the unit.
Page 4
Kramer Electronics Ltd.
PT-12 – Introduction
2

Recycling Kramer Products

The Waste Electrical and Electronic Equipment (WEEE) Directive 2002/96/EC aims to reduce the amount of WEEE sent for disposal to landfill or incineration by requiring it to be collected and recycled. To comply with the WEEE Directive, Kramer Electronics has made arrangements with the European Advanced Recycling Network (EARN) and will cover any costs of treatment, recycling and recovery of waste Kramer
Electronics branded equipment on arrival at the EARN facility. For details of Kramer’s
recycling arrangements in your particular country go to our recycling pages at
www.kramerav.com/support/recycling.

Overview

Congratulations on purchasing your Kramer PT-12 HDMI Controller. PT-12 is a CEC-enabled TV/display ON/OFF controller and extended EDID processor for HDMI signals up to 4K@60Hz (4:2:0) resolution. When PT-12 detects an HDMI cable plug, it automatically turns ON the connected display, and automatically shuts OFF the display when signal loss is detected. PT-12 is also a processing tool for controlling the EDID functions.

Features

Automates Meeting Rooms – Simplifies meeting beginning and ending by automatically turning ON a CEC-enabled display when the presentation source is plugged in and OFF when the source is unplugged. The shutdown delay time is user-defined.
High-Performance HDMI Controller – Supports pass-through of signals up to 4K@60Hz (4:2:0) resolution with user control of signal capabilities and functions.
Selectable HDCP Authorization – Allows the user to control the appearance of an HDCP or non-HDCP input to the source to permit delivery of protection-free content, such as personal clips and charts, without HDCP encryption. HDCP protected content is not passed in non-HDCP mode.
Video Signal Control – Define color depth attributes and color space capabilities of pass-through video signal. Lock the EDID configuration to ensure proper video display.
Audio Signal Control – User defines whether to allow the full signal to pass through or to limit the audio to 2 channel LPCM.
Simple Operation – Includes DIP-switches for defining basic controller functions.
Cost-Effective Maintenance – Status LED indicators for HDMI ports and power
facilitate easy local maintenance and troubleshooting. Local device management and firmware upgrade via mini-USB port and DIP-switches, ensure lasting, field­proven deployment.
Easy Installation – Compact, fan-less PicoTOOLS® enclosure for device-back mounting, or side-by-side mounting of 4 units in a 1U rack space with the recommended Kramer rack adapter.
Page 5
Kramer Electronics Ltd.
PT-12 – Introduction
3

Typical Applications

PT-12 is ideal for the following typical applications:
Home theatre or meeting room, automatic TV ON/OFF controller.
Adapting new device compatibilities with older AV infrastructure.
Supporting AV troubleshooting.
Page 6
Kramer Electronics Ltd.
PT-12 – Defining PT-12 HDMI Controller
4

Defining PT-12 HDMI Controller

This section defines PT-12.
Figure 1: PT-12 HDMI Controller
#
Feature
Function
SERVICE Mini USB Connector
Connect to a PC/laptop to modify the EDID using EDID Designer software, control PT-12 via P3K protocol or to update the firmware.
IN LED
Lights green when an active HDMI source is connected to the input.
OUT LED
Lights green when an HDMI acceptor is connected to the output. Flashes three times upon successful load of the designed EDID and then resumes normal operation.
ON LED
Lights green when power is connected.
HDMI® IN Connector
Connect to an HDMI source.
HDMI® OUT Connector
Connect to an HDMI acceptor.
SETUP DIP-Switches
Use to configure device settings (see Configuring Using DIP-Switches on page 7).
5V DC Power Connector
Connect to the included power adapter.
1 2 3
4 5 6 7 8
Page 7
Kramer Electronics Ltd.
PT-12 – Mounting PT-12
5

Mounting PT-12

This section provides instructions for mounting PT-12. Before installing, verify that the environment is within the recommended range:
Operation temperature – 0 to 40C (32 to 104F).
Storage temperature – -40 to +70C (-40 to +158F).
Humidity – 10% to 90%, RHL non-condensing.
Caution:
Mount PT-12 before connecting any cables or power.
Warning:
Ensure that the environment (e.g., maximum ambient temperature & air flow) is compatible for the device.
Avoid uneven mechanical loading.
Appropriate consideration of equipment nameplate ratings should be used for
avoiding overloading of the circuits.
Reliable earthing of rack-mounted equipment should be maintained.
Maximum mounting height for the device using supplied brackets is 2 meters.
To mount PT-12 in a rack:
Mount the unit in a rack using the recommended rack adapter (see www.kramerav.com/product/PT-12).
To mount PT-12 on a table or shelf:
Attach the rubber feet and place the unit on a flat surface.
Fasten a bracket (included) on each side of the unit and
attach it to a flat surface.
For more information go to www.kramerav.com/downloads/PT-12.
Page 8
Kramer Electronics Ltd.
PT-12 – Connecting PT-12
6

Connecting PT-12

Always switch off the power to each device before connecting it to your PT-12. After connecting your PT-12, connect its power and then switch on the power to each device.
Figure 2: Connecting to the PT-12
To connect PT-12 as illustrated in the example in Figure 2:
1. Connect the HDMI source (for example, an AV receiver) to the HDMI IN Connector on the front panel.
2. Connect the HDMI OUT Connector to a CEC-enabled display.
3. Connect the power adapter to PT-12 and to the mains electricity (not shown in
Figure 2).
5
6
Page 9
Kramer Electronics Ltd.
PT-12 – Configuring PT-12
7

Configuring PT-12

You can configure PT-12 in the following ways:
DIP-Switches (see Configuring Using DIP-Switches on page 7).
EDID Designer Software – to modify the EDID (see Modifying EDID with EDID
Designer on page 9).
Protocol 3000 API (see Protocol 3000 Commands on page 15).

Configuring Using DIP-Switches

PT-12 enables you to control EDID lock, define signal parameters, configure display
auto power and display auto sleep, and upgrade the device firmware using the DIP­switches on the back panel.
The following table describes the PT-12 DIP-switches. By default, all switches are in the OFF (up) position.
All changes in the DIP-switch settings take effect on-the-fly, without the need for a power cycle.
#
Feature
Description
1
EDID Lock
OFF (up) – Lock the current EDID so that changes on the output do not result in changes to the EDID. ON (down) – EDID is passed-through and acquired automatically.
2
Deep Color
OFF (up) – Limit color depth to 8 bits per color. ON (down) – Pass-through color depth parameters.
3
Audio Pass-through
OFF (up) – Audio transmission is limited to 2-channel LPCM only. ON (down) – Audio transmission is passed-through.
Audio pass-through setup takes effect only when DIP-switch 1 is OFF (EDID locked), otherwise, it is ignored.
4
HDCP Operation
OFF (up) – HDCP is disabled, giving the appearance that HDCP is not supported. ON (down) – HDCP is enabled, giving the appearance of an HDCP authorized device to allow unsecured content display by all market-available computer sources.
5
Display Auto Power
OFF (up) – Display auto power is enabled. ON (down) – Display auto power is disabled.
6, 7
Display Auto Sleep
Enable/disable auto delay (before 5V output cut-off) of the connected display when no active input signal is detected.
DIP 6
DIP 7
Delay before Auto Sleep (before 5V output cut-off)
OFF
OFF
Auto Sleep is disabled
ON
OFF
5s
OFF
ON
1m
ON
ON
15m
8
CPU FW Upgrade
OFF (up) – Normal operation mode. ON (down) – CPU firmware upgrade mode.
When set to ON the device is inactive.
Page 10
Kramer Electronics Ltd.
PT-12 – Configuring PT-12
8

Configuring Automatic Power Controls

PT-12 enables you to configure the following automatic power controls for your
connected display:
Configuring Display Auto Sleep on page 8.
Configuring Display Auto Power on page 8.

Configuring Display Auto Sleep

As long as there is an active source signal, the connected display remains ON. When the active source becomes incative, a 5V signal is sent to the display to delay it from going into sleep (standby) mode. PT-12 enables you to enable/disable and set the delay time before the 5V output cuts off.
To configure the auto sleep delay:
Set DIP-switch 6 and 7 to the required position (see Configuring Using DIP-
Switches on page 7).

Configuring Display Auto Power

PT-12 features display auto power via CEC communication. This feature turns ON a
display that is in sleep mode when an active signal is detected and turns it OFF (shuts down) when the active signal becomes inactive. PT-12 enables you to enable/disable display auto power and to set the delay time before the display is turned OFF.
Enabling/Disabling Display Auto Power
To enable/disable the display auto power feature:
Set DIP-switch 5 to the required position (see Configuring Using DIP-Switches on page 7).
Setting Delay Time for Display Auto Power Shutdown
When the display auto sleep delay (see Configuring Display Auto Sleep on page 8) is set to a shorter time than the display auto power delay, the 5V does not shut OFF until display auto power turns OFF the display.
To set the delay time before display auto power shutdown:
Use the AV-SWITCHING-MODE command (see Protocol 3000 Commands on page 15).

Defining EDID Lock

PT-12 enables you to define whether to enable the EDID values to be passed through
the device and changed automatically to follow the output or to lock the EDID so that it will not be affected by changes on the output.
Page 11
Kramer Electronics Ltd.
PT-12 – Configuring PT-12
9
To define EDID lock:
Set DIP-switch 1 to the required position (see Configuring Using DIP-Switches on page 7).

Modifying EDID with EDID Designer

To download the software and user manual for EDID Designer, go to:
www.kramerav.com/product/PT-12.
To modify the EDID with Kramer EDID Designer software:
1. Connect your computer to the PT-12 SERVICE Mini USB Connector .
2. Use the Kramer EDID Designer software.

Defining Color Depth and Spacing

PT-12 enables you to define the color depth pass-through and to force RGB color
spacing.

Defining Color Depth Pass-Through

PT-12 enables you to define whether to pass the full color depth parameters through
the device or to limit color depth to 8 bits per color.
To define color depth pass-through:
Set DIP-switch 2 to the required position (see Configuring Using DIP-Switches on page 7).

Forcing RGB Color Spacing

To force RGB color spacing:
Use the CS-CONVERT Protocol 3000 API command (see Protocol 3000
Commands on page 15).

Defining Audio Pass-Through

PT-12 enables you to define whether the full audio transmission is passed through the
device or the audio transmission is limited to 2-channel LPCM only.
To define audio pass-through:
Set DIP-switch 3 to the required position (see Configuring Using DIP-Switches on page 7).
1
Page 12
Kramer Electronics Ltd.
PT-12 – Upgrading Firmware
10

Setting HDCP Operation

PT-12 enables you to enable or disable HDCP. When HDCP is enabled, the PT-12
input appears to be HDCP compliant to the connected source, and vice versa. This allows the source to transmit a non-HDCP signal, if required.
To set HDCP operation:
Set DIP-switch 4 to the required position (see Configuring Using DIP-Switches on page 7).

Upgrading Firmware

Use Kramer K-UPLOAD software to upgrade the firmware via the PT-12 SERVICE Mini USB Connector when DIP-switch 8 set to ON (down position).
The latest version of K-UPLOAD and installation instructions can be downloaded from our website at: www.kramerav.com/support/product_downloads.asp.
Before using the micro USB port, install the Kramer USB driver, available at:
www.kramerav.com/support/product_downloads.asp.
1
Page 13
Kramer Electronics Ltd.
PT-12 – Technical Specifications
11

Technical Specifications

Inputs
1 HDMI
On a female HDMI connector
Outputs
1 HDMI
On a female HDMI connector
Ports
1 USB
On a female mini USB connector
Video
Max Resolution
4K@60Hz (4:2:0)
Max Data Rate
10.2Gbps (3.4Gbps per data channel)
Compliance
HDCP 1.4
User Interface Controls
8 DIP-switches
Indicator
HDMI In, HDMI Out, Power LEDs
Power Source
5V DC
Consumption
315mA
Environmental Conditions
Operating Temperature
0° to +40°C (32° to 104°F)
Storage Temperature
-40° to +70°C (-40° to 158°F)
Humidity
10% to 90%, RHL non-condensing
Regulatory Compliance
Vibration
ISTA 1A in carton (International Safe Transit Association)
Safety
CE
Environmental
RoHs, WEEE
Enclosure
Size
PicoTOOLS®
Type
Aluminum
Cooling
Convection ventilation
General
Net Dimensions (W, D, H)
6.22cm x 5.18cm x 2.44cm (2.45" x 2.04" x 0.96" ) W, D, H
Shipping Dimensions (W, D, H)
15.70cm x 12.00cm x 8.70cm (6.18" x 4.72" x 3.43" ) W, D, H
Net Weight
0.1kg (0.2lbs) approx.
Shipping Weight
0.6kg (1.3lbs) approx.
Accessories
Included
Power adapter, bracket kit
Specifications are subject to change without notice at www.kramerav.com
Page 14
Kramer Electronics Ltd.
PT-12 – Default EDID
12

Default EDID

Monitor
Model name............... PT-12
Manufacturer............. KMR
Plug and Play ID......... KMR1200
Serial number............ n/a
Manufacture date......... 2015, ISO week 255
Filter driver............ None
-------------------------
EDID revision............ 1.3
Input signal type........ Digital
Color bit depth.......... Undefined
Display type............. RGB color
Screen size.............. 520 x 320 mm (24.0 in)
Power management......... Standby, Suspend, Active off/sleep
Extension blocs.......... 1 (CEA-EXT)
-------------------------
DDC/CI................... Supported
MCCS revison............. 2.1
Display technology....... TFT
Controller............... STMicro 0x9301
Firmware revision........ 2.1
Firmware flags........... 0x006645CC
Active power on time..... Not supported
Power consumption........ Not supported
Current frequency........ 74.20kHz, 60.20Hz
Color characteristics
Default color space...... Non-sRGB
Display gamma............ 2.20
Red chromaticity......... Rx 0.674 - Ry 0.319
Green chromaticity....... Gx 0.188 - Gy 0.706
Blue chromaticity........ Bx 0.148 - By 0.064
White point (default).... Wx 0.313 - Wy 0.329
Additional descriptors... None Timing characteristics
Horizontal scan range.... 30-83kHz
Vertical scan range...... 56-76Hz
Video bandwidth.......... 170MHz
CVT standard............. Not supported
GTF standard............. Not supported
Additional descriptors... None
Preferred timing......... Yes
Native/preferred timing.. 1280x720p at 60Hz (16:10)
Modeline............... "1280x720" 74.250 1280 1390 1430 1650 720 725 730 750 +hsync +vsync
Standard timings supported 720 x 400p at 70Hz - IBM VGA 720 x 400p at 88Hz - IBM XGA2 640 x 480p at 60Hz - IBM VGA 640 x 480p at 67Hz - Apple Mac II 640 x 480p at 72Hz - VESA 640 x 480p at 75Hz - VESA 800 x 600p at 56Hz - VESA 800 x 600p at 60Hz - VESA 800 x 600p at 72Hz - VESA 800 x 600p at 75Hz - VESA 832 x 624p at 75Hz - Apple Mac II 1024 x 768i at 87Hz - IBM 1024 x 768p at 60Hz - VESA 1024 x 768p at 70Hz - VESA 1024 x 768p at 75Hz - VESA 1280 x 1024p at 75Hz - VESA 1152 x 870p at 75Hz - Apple Mac II 1280 x 1024p at 75Hz - VESA STD 1280 x 1024p at 85Hz - VESA STD 1600 x 1200p at 60Hz - VESA STD 1024 x 768p at 85Hz - VESA STD 800 x 600p at 85Hz - VESA STD 640 x 480p at 85Hz - VESA STD 1152 x 864p at 70Hz - VESA STD 1280 x 960p at 60Hz - VESA STD EIA/CEA-861 Information
Revision number.......... 3
IT underscan............. Supported
Basic audio.............. Supported
YCbCr 4:4:4.............. Supported
YCbCr 4:2:2.............. Supported
Native formats........... 1
Detailed timing #1....... 1920x1080p at 60Hz (16:10)
Modeline............... "1920x1080" 148.500 1920 2008 2052 2200 1080 1084 1089 1125 +hsync +vsync
Detailed timing #2....... 1920x1080i at 60Hz (16:10)
Modeline............... "1920x1080" 74.250 1920 2008 2052 2200 1080 1084 1094 1124 interlace +hsync +vsync
Detailed timing #3....... 1280x720p at 60Hz (16:10)
Modeline............... "1280x720" 74.250 1280 1390 1430 1650 720 725 730 750 +hsync +vsync
Detailed timing #4....... 720x480p at 60Hz (16:10)
Modeline............... "720x480" 27.000 720 736 798 858 480 489 495 525 -hsync -vsync
CE audio data (formats supported) LPCM 2-channel, 16/20/24 bit depths at 32/44/48 kHz CE video identifiers (VICs) - timing/formats supported 1920 x 1080p at 60Hz - HDTV (16:9, 1:1) 1920 x 1080i at 60Hz - HDTV (16:9, 1:1) 1280 x 720p at 60Hz - HDTV (16:9, 1:1) [Native] 720 x 480p at 60Hz - EDTV (16:9, 32:27) 720 x 480p at 60Hz - EDTV (4:3, 8:9) 720 x 480i at 60Hz - Doublescan (16:9, 32:27) 720 x 576i at 50Hz - Doublescan (16:9, 64:45) 640 x 480p at 60Hz - Default (4:3, 1:1) NB: NTSC refresh rate = (Hz*1000)/1001 CE vendor specific data (VSDB) IEEE registration number. 0x000C03
CEC physical address..... 1.0.0.0
Page 15
Kramer Electronics Ltd.
PT-12 – Default EDID
13
Maximum TMDS clock....... 165MHz
CE speaker allocation data
Channel configuration.... 2.0
Front left/right......... Yes
Front LFE................ No
Front center............. No
Rear left/right.......... No
Rear center.............. No
Front left/right center.. No Rear left/right center... No
Rear LFE................. No
Report information
Date generated........... 2/16/2016
Software revision........ 2.60.0.972
Data source.............. Real-time 0x0041
Operating system......... 6.1.7601.2.Service Pack 1
Raw data 00,FF,FF,FF,FF,FF,FF,00,2D,B2,00,12,00,00,00,00,FF,19,01,03,80,34,20,78,EA,B3,25,AC,51,30,B4,26, 10,50,54,FF,FF,80,81,8F,81,99,A9,40,61,59,45,59,31,59,71,4A,81,40,01,1D,00,72,51,D0,1E,20,6E,28, 55,00,07,44,21,00,00,1E,00,00,00,FD,00,38,4C,1E,53,11,00,0A,20,20,20,20,20,20,00,00,00,FC,00,50, 54,2D,32,43,20,20,20,20,20,20,20,20,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,01,CD, 02,03,1B,F1,23,09,07,07,48,10,05,84,03,02,07,16,01,65,03,0C,00,10,00,83,01,00,00,02,3A,80,18,71, 38,2D,40,58,2C,45,00,07,44,21,00,00,1E,01,1D,80,18,71,1C,16,20,58,2C,25,00,07,44,21,00,00,9E,01, 1D,00,72,51,D0,1E,20,6E,28,55,00,07,44,21,00,00,1E,8C,0A,D0,8A,20,E0,2D,10,10,3E,96,00,07,44,21, 00,00,18,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,47
Page 16
Kramer Electronics Ltd.
PT-12 – Protocol 3000
14

Protocol 3000

Kramer devices can be operated using Kramer Protocol 3000 commands sent via serial or Ethernet ports.

Understanding Protocol 3000

Protocol 3000 commands are a sequence of ASCII letters, structured according to the following.
Command format:
Prefix
Command Name
Constant (Space)
Parameter(s)
Suffix
#
Command
Parameter
<CR>
Feedback format:
Prefix
Device ID
Constant
Command Name
Parameter(s)
Suffix
~
nn @ Command
Parameter
<CR><LF>
Command parameters – Multiple parameters must be separated by a comma (,). In addition, multiple parameters can be grouped as a single parameter using brackets ([ and ]).
Command chain separator character – Multiple commands can be chained in the same string. Each command is delimited by a pipe character (|).
Parameters attributes Parameters may contain multiple attributes. Attributes are indicated with pointy brackets (<…>) and must be separated by a period (.).
The command framing varies according to how you interface with PT-12. The following figure displays how the # command is framed using terminal communication software (such as Hercules):
Page 17
Kramer Electronics Ltd.
PT-12 – Protocol 3000
15

Protocol 3000 Commands

Function
Description
Syntax
Parameters/Attributes
Example
#
Protocol handshaking.
Validates the Protocol 3000 connection and gets the machine number.
Step-in master products use this command to identify the availability of a device.
COMMAND
#<CR>
FEEDBACK
~nn@ok<CR><LF>
#<CR>
AV-SW­TIMEOUT
Set display auto power shutdown (via CEC communication) delay after active signal stops.
COMMAND
#AV-SW-TIMEOUTswitching_mode,time_out<CR>
FEEDBACK
~nn@AV-SW-TIMEOUTswitching_mode,time_out<CR><LF>
switching_mode – Switching mode
8 – display auto power shutdown
time_out – Delay in seconds
0 - 60000
Set the display auto shutdown for 60 seconds after the active signal stops:
#AV-SW-TIMEOUT8,60<CR>
AV-SW­TIMEOUT?
Get display auto power shutdown (via CEC communication) delay after active signal stops.
COMMAND
#AV-SW-TIMEOUT?switching_mode<CR>
FEEDBACK
~nn@AV-SW-TIMEOUTswitching_mode,time_out<CR><LF>
switching_mode – Switching mode
8 – display auto power shutdown
time_out – Delay in seconds
0 - 60000
Get the display auto shutdown delay time:
#AV-SW-TIMEOUT?8<CR>
BUILD-DATE?
Get device build date.
COMMAND
#BUILD-DATE?<CR>
FEEDBACK
~nn@BUILD-DATEdate,time<CR><LF>
date – Format: YYYY/MM/DD where
YYYY = Year MM = Month DD = Day
time – Format: hh:mm:ss where
hh = hours mm = minutes ss = seconds
Get the device build date:
#BUILD-DATE?<CR> CEC-MODE?
Get the CEC mode status.
COMMAND
#CEC-MODE?<CR>
FEEDBACK
~nn@CEC-MODEcec_mode<CR><LF>
cec_mode – CEC mode
0 – CEC mode switched off and
automatic TV power function disabled
1 – CEC mode switched on and
automatic TV power function enabled
Get the CEC mode status:
#CEC-MODE?<CR>
CPEDID
Copy EDID data from the output to the input EEPROM.
Destination bitmap size depends on device properties (for 64 inputs it is a 64-bit word).
Example: bitmap 0x0013 means inputs 1,2 and 5 are loaded with the new EDID.
In certain products Safe_mode is an optional parameter. See the HELP command for its availability.
COMMAND
#CPEDIDedid_io,src_id,edid_io,dest_bitmap<CR>
or
#CPEDIDedid_io,src_id,edid_io,dest_bitmap,safe_mode<CR>
FEEDBACK
~nn@CPEDIDedid_io,src_id,edid_io,dest_bitmap<CR><LF>
~nn@CPEDIDedid_io,src_id,edid_io,dest_bitmap,safe_mode<C
R><LF>
edid_io – EDID source type (usually
output)
0 – Input 1 – Output 2 – Default EDID 3 – Custom EDID
src_id – Number of chosen source
stage
0 – Default EDID source 1 – Output 1
edid_io – EDID destination type
(usually input)
0 – Input 1 – Output 2 – Default EDID 3 – Custom EDID
dest_bitmap Bitmap representing
destination IDs. Format: XXXX…X,
where X is hex digit. The binary form of every hex digit represents corresponding destinations.
0 – indicates that EDID data is not
copied to this destination.
1 – indicates that EDID data is copied
to this destination.
safe_mode – Safe mode
0 – device accepts the EDID as is
without trying to adjust
1 – device tries to adjust the EDID
(default value if no parameter is sent)
Copy the EDID data from the Output 1 (EDID source) to the Input:
#CPEDID1,1,0,0x1<CR>
Copy the EDID data from the default EDID source to the Input:
#CPEDID2,0,0,0x1<CR>
CS-CONVERT
Set the “force RGB color space” convert mode.
COMMAND
#CS-CONVERTout_index,cs_mode<CR>
FEEDBACK
~nn@CS-CONVERTout_index,cs_mode<CR><LF>
out_index – Number that indicates
the specific output: 1
cs_mode – Index in resolution table
0 – Color space pass (default) 1 – Enable “force RGB color space”
convert mode
Enable “force RGB color
space” convert mode for
output 1:
#CS-CONVERT1,1<CR>
CS-CONVERT?
Get the “force RGB color space” convert mode
status.
COMMAND
#CS-CONVERT?out_index<CR>
FEEDBACK
~nn@CS-CONVERTout_index,cs_mode<CR><LF>
out_index – Number that indicates
the specific output: 1
cs_mode – Index in resolution table
0 – Color space pass (default) 1 – Enable “force RGB color space”
convert mode
Get the “force RGB color space” convert mode status for
channel 1:
#CS-CONVERT1<CR>
DISPLAY?
Get output HPD status.
COMMAND
#DISPLAY?out_index<CR>
FEEDBACK
~nn@DISPLAYout_index,status<CR><LF>
out_index – Number that indicates
the specific output: 1
status – HPD status according to
signal validation
0 – Signal or sink is not valid 1 – Signal or sink is valid 2 – Sink and EDID is valid
Get the output HPD status of Output 1:
#DISPLAY?1<CR>
Page 18
Kramer Electronics Ltd.
PT-12 – Protocol 3000
16
Function
Description
Syntax
Parameters/Attributes
Example
DPSW-STATUS?
Get the DIP-switch state.
COMMAND
#DPSW-STATUS?dip_id<CR>
FEEDBACK
~nn@DPSW-STATUSdip_id,status<CR><LF>
dip_id – 1 to 8 (number of DIP
switches)
status – Up/down
0 – Up 1 – Down
Get the DIP-switch 2 status:
#DPSW-STATUS?2<CR>
FACTORY
Reset device to factory default configuration.
This command deletes all user data from the device. The deletion can take some time.
Your device may require powering off and powering on for the changes to take effect.
COMMAND
#FACTORY<CR>
FEEDBACK
~nn@FACTORYok<CR><LF>
Reset the device to factory default configuration:
#FACTORY<CR>
GEDID
Get EDID support on certain input/output.
COMMAND
#GEDIDio_mode,in_index<CR>
FEEDBACK
~nn@GEDIDio_mode,in_index,size<CR><LF>
io_mode – Input/Output
0 – Input 1 – Output
in_index – Number that indicates the
specific input: 1
size – Size of data to be sent from
device, 0 means no EDID support
Get EDID support information for input 1:
#GEDID1,1<CR>
HDCP-MOD?
Get HDCP mode.
Set HDCP working mode on the device input:
HDCP supported ­HDCP_ON [default].
HDCP not supported ­HDCP OFF.
HDCP support changes following detected sink ­MIRROR OUTPUT.
COMMAND
#HDCP-MOD?in_index<CR>
FEEDBACK
~nn@HDCP-MODin_index,mode<CR><LF>
in_index – Number that indicates the
specific input: 1-N (N= the total number of inputs)
mode – HDCP mode:
0 – HDCP Off 3 – HDCP defined according to the
connected output
Get the input HDCP-MODE of IN 1 HDMI:
#HDCP-MOD?1<CR>
HDCP-STAT?
Get HDCP signal status.
io_mode =1 – get the HDCP signal status of the sink device connected to the specified output.
io_mode =0 – get the HDCP signal status of the source device connected to the specified input.
COMMAND
#HDCP-STAT?io_mode,in_index<CR>
FEEDBACK
~nn@HDCP-STATio_mode,in_index,status<CR><LF>
io_mode – Input/Output
0 – Input 1 – Output
in_index – Number that indicates the
specific input: 1-N (N= the total number of inputs)
status – Signal encryption status -
valid values On/Off
0 – HDCP Off 1 – HDCP On
Get the output HDCP-STATUS of IN 1:
#HDCP-STAT?0,1<CR>
HELP
Get command list or help for specific command.
COMMAND
#HELP<CR>
#HELPcmd_name<CR>
FEEDBACK
1. Multi-line:
~nn@Devicecmd_name,cmd_name…<CR><LF>
To get help for command use: HELP (COMMAND_NAME)<CR><LF>
~nn@HELPcmd_name:<CR><LF>
description<CR><LF>
USAGE:usage<CR><LF>
cmd_name – Name of a specific
command
Get the command list:
#HELP<CR>
To get help for AV-SW-TIMEOUT: HELPav-sw-timeout<CR>
Page 19
Kramer Electronics Ltd.
PT-12 – Protocol 3000
17
Function
Description
Syntax
Parameters/Attributes
Example
LDEDID
Write EDID data from external application to device.
When the unit receives the LDEDID command it replies with READY and enters the special EDID packet wait mode. In this mode the unit can receive only packets and not regular protocol commands.
If the unit does not receive correct packets for 30 seconds or is interrupted for more than 30 seconds before receiving all packets, it sends timeout error
~nn@LDEDIDerr01<C
R><LF> and returns to
the regular protocol mode. If the unit received data that is not a correct packet, it sends the corresponding error and returns to the regular protocol mode.
COMMAND
Multi-step syntax
FEEDBACK
Step 1:
#LDEDIDedid_io,dest_bitmask,edid_size,safe_mode<CR>
Response 1:
~nn@LDEDIDedid_io,dest_bitmask,edid_size,safe_modeready
<CR><LF>
or
~nn@LDEDIDerrnn<CR><LF>
Step 2: If ready was received, send EDID_DATA Response 2:
~nn@LDEDIDedid_io,dest_bitmask,edid_size,safe_modeok<CR
><LF>
or
~nn@LDEDIDerrnn<CR><LF>
edid_io – EDID destination type
(usually input)
0 – Input 1 – Output 2 – Default EDID 3 – Custom EDID
dest_bitmask – Bitmap representing
destination IDs. Format: 0x********, where * is ASCII presentation of hex digit. The binary presentation of this number is a bit mask for destinations.
Setting ‘1’ means EDID data has to be
copied to this destination
edid_size – EDID data size safe_mode – Safe mode
0 – Device accepts the EDID as is
without trying to adjust
1 – Device tries to adjust the EDID
edid_data – Data in protocol packets
Using the Packet Protocol
Send a command: LDRV, LOAD,
IROUT, LDEDID Receive Ready or ERR### If Ready:
a. Send a packet,
b. Receive OK on the last packet,
c. Receive OK for the command
Packet structure:
Packet ID (1, 2, 3…) (2 bytes in
length)
Length (data length + 2 for CRC)
– (2 bytes in length)
Data (data length -2 bytes)
CRC – 2 bytes
01
02
03
04
05 Packet ID
Length
Data
CRC
5. Response: ~nnnnok<CR><LF>
(Where NNNN is the received
packet ID in ASCII hex digits.)
Write the EDID data from an external application to the HDMI In 1 input without adjustment attempts:
#LDEDID0,0x1,2340,0<CR
>
Write the EDID data from an external application to HDMI In 1 and PC In inputs with adjustment attempts:
#LDEDID0,0x5,2340,1<CR
>
MODEL?
Get device model.
This command identifies equipment connected to PT-12 and notifies of identity changes to the connected equipment. The Matrix saves this data in memory to answer REMOTE-INFO requests.
COMMAND
#MODEL?<CR>
FEEDBACK
~nn@MODELmodel_name<CR><LF>
model_name – String of up to 19
printable ASCII chars
Get the device model:
#MODEL?<CR>
NAME
Set machine (DNS) name.
The machine name is not the same as the model name. The machine name is used to identify a specific machine or a network in use (with DNS feature on).
COMMAND
#NAMEmachine_name<CR>
FEEDBACK
~nn@NAMEmachine_name<CR><LF>
machine_name – String of up to 15
alpha-numeric chars (can include hyphen, not at the beginning or end)
Set the DNS name of the device to room-442:
#NAMEroom-442<CR>
NAME?
Get machine (DNS) name.
The machine name is not the same as the model name. The machine name is used to identify a specific machine or a network in use (with DNS feature on).
COMMAND
#NAME?<CR>
FEEDBACK
~nn@NAMEmachine_name<CR><LF>
machine_name – String of up to 15
alpha-numeric chars (can include hyphen, not at the beginning or end)
Get the DNS name of the device:
#NAME?<CR> NAME-RST
Reset machine (DNS) name to factory default.
Factory default of machine (DNS) name is
“KRAMER_” + 4 last
digits of device serial number.
COMMAND
#NAME-RST<CR>
FEEDBACK
~nn@NAME-RSTok<CR><LF>
Reset the machine name (S/N last digits are 0102):
#NAME­RSTkramer_0102<CR>
PROT-VER?
Get device protocol version.
COMMAND
#PROT-VER?<CR>
FEEDBACK
~nn@PROT-VER3000:version<CR><LF>
version – XX.XX where X is a
decimal digit
Get the device protocol version:
#PROT-VER?<CR>
RESET
Reset device.
To avoid locking the port due to a USB bug in Windows, disconnect USB connections immediately after running this command. If the port was locked, disconnect and reconnect the cable to reopen the port.
COMMAND
#RESET<CR>
FEEDBACK
~nn@RESETok<CR><LF>
Reset the device:
#RESET<CR>
Page 20
Kramer Electronics Ltd.
PT-12 – Protocol 3000
18
Function
Description
Syntax
Parameters/Attributes
Example
SIGNAL?
Get input signal status.
COMMAND
#SIGNAL?in_index<CR>
FEEDBACK
~nn@SIGNALin_index,status<CR><LF>
in_index – Number that indicates the
specific input: 1-N (N= the total number of inputs)
status – Signal status according to
signal validation:
0 – Off 1 – On
Get the input signal lock status of IN 1:
#SIGNAL?1<CR>
SN?
Get device serial
number.
COMMAND
#SN?<CR>
FEEDBACK
~nn@SNserial_num<CR><LF>
serial_num – 14 decimal digits,
factory assigned
Get the device serial number:
#SN?<CR>
VERSION?
Get firmware version number.
COMMAND
#VERSION?<CR>
FEEDBACK
~nn@VERSIONfirmware_version<CR><LF>
firmware_version – XX.XX.XXXX
where the digit groups are: major.minor.build version
Get the device firmware version number:
#VERSION?<CR>
Page 21
Kramer Electronics Ltd.
PT-12 – Protocol 3000
19

Result and Error Codes

Syntax

In case of an error, the device responds with an error message. The error message syntax:
~NN@ERR XXX<CR><LF> – when general error, no specific command
~NN@CMD ERR XXX<CR><LF> – for specific command
NN – machine number of device, default = 01
XXX – error code

Error Codes

Error Name
Error Code
Description
P3K_NO_ERROR
0
No error
ERR_PROTOCOL_SYNTAX
1
Protocol syntax
ERR_COMMAND_NOT_AVAILABLE
2
Command not available
ERR_PARAMETER_OUT_OF_RANGE
3
Parameter out of range
ERR_UNAUTHORIZED_ACCESS
4
Unauthorized access
ERR_INTERNAL_FW_ERROR
5
Internal FW error
ERR_BUSY
6
Protocol busy
ERR_WRONG_CRC
7
Wrong CRC
ERR_TIMEDOUT
8
Timeout
ERR_RESERVED
9
(Reserved)
ERR_FW_NOT_ENOUGH_SPACE
10
Not enough space for data (firmware, FPGA…)
ERR_FS_NOT_ENOUGH_SPACE
11
Not enough space – file system
ERR_FS_FILE_NOT_EXISTS
12
File does not exist
ERR_FS_FILE_CANT_CREATED
13
File can’t be created
ERR_FS_FILE_CANT_OPEN
14
File can’t open
ERR_FEATURE_NOT_SUPPORTED
15
Feature is not supported
ERR_RESERVED_2
16
(Reserved)
ERR_RESERVED_3
17
(Reserved)
ERR_RESERVED_4
18
(Reserved)
ERR_RESERVED_5
19
(Reserved)
ERR_RESERVED_6
20
(Reserved)
ERR_PACKET_CRC
21
Packet CRC error
ERR_PACKET_MISSED
22
Packet number isn't expected (missing packet)
ERR_PACKET_SIZE
23
Packet size is wrong
ERR_RESERVED_7
24
(Reserved)
ERR_RESERVED_8
25
(Reserved)
ERR_RESERVED_9
26
(Reserved)
ERR_RESERVED_10
27
(Reserved)
ERR_RESERVED_11
28
(Reserved)
ERR_RESERVED_12
29
(Reserved)
ERR_EDID_CORRUPTED
30
EDID corrupted
ERR_NON_LISTED
31
Device specific errors
ERR_SAME_CRC
32
File has the same CRC – no changed
ERR_WRONG_MODE
33
Wrong operation mode
ERR_NOT_CONFIGURED
34
Device/chip was not initialized
Page 22
The warranty obligations of Kramer Electronics Inc. (“Kramer Electronics”) for this product are limited to the terms set forth below:
What is Covered
This limited warranty covers defects in materials and workmanship in this product.
What is Not Covered
This limited warranty does not cover any damage, deterioration or malfunction resulting from any alteration, modification, improper or unreasonable use or maintenance, misuse, abuse, accident, neglect, exposure to excess moisture, fire, improper packing and shipping (such claims must be presented to the carrier), lightning, power surges, or other acts of nature. This limited warranty does not cover any damage, deterioration or malfunction resulting from the installation or removal of this product from any installation, any unauthorized tampering with this product, any repairs attempted by anyone unauthorized by Kramer Electronics to make such repairs, or any other cause which does not relate directly to a defect in materials and/or workmanship of this product. This limited warranty does not cover cartons, equipment enclosures, cables or accessories used in conjunction with this product. Without limiting any other exclusion herein, Kramer Electronics does not warrant that the product covered hereby, including, without limitation, the technology and/or integrated circuit(s) included in the product, will not become obsolete or that such items are or will remain compatible with any other product or technology with which the product may be used.
How Long this Coverage Lasts
The standard limited warranty for Kramer products is seven (7) years from the date of original purchase, with the following exceptions:
1. All Kramer VIA hardware products are covered by a standard three (3) year warranty for the VIA hardware and a standard three (3) year warranty for firmware and software updates; all Kramer VIA accessories, adapters, tags, and dongles are covered by a standard one (1) year warranty.
2. Kramer fiber optic cables, adapter-size fiber optic extenders, pluggable optical modules, active cables, cable retractors, ring mounted adapters, portable power chargers, Kramer speakers, and Kramer touch panels are all covered by a standard one (1) year warranty.
3. All Kramer Cobra products, all Kramer Calibre products, all Kramer Minicom digital signage products, all HighSecLabs products, all streaming, and all wireless products are covered by a standard three (3) year warranty.
4. All Sierra Video MultiViewers are covered by a standard five (5) year warranty.
5. Sierra switchers & control panels are covered by a standard seven (7) year warranty (excluding power supplies and fans that are covered for three (3) years).
6. K-Touch software is covered by a standard one (1) year warranty for software updates.
7. All Kramer passive cables are covered by a ten (10) year warranty.
Who is Covered
Only the original purchaser of this product is covered under this limited warranty. This limited warranty is not transferable to subsequent purchasers or owners of this product.
What Kramer Electronics Will Do
Kramer Electronics will, at its sole option, provide one of the following three remedies to whatever extent it shall deem necessary to satisfy a proper claim under this limited warranty:
1. Elect to repair or facilitate the repair of any defective parts within a reasonable period of time, free of any charge for the necessary parts and labor to complete the repair and restore this product to its proper operating condition. Kramer Electronics will also pay the shipping costs necessary to return this product once the repair is complete.
2. Replace this product with a direct replacement or with a similar product deemed by Kramer Electronics to perform substantially the same function as the original product. If a direct or similar replacement product is supplied, the original product’s end warranty date remains unchanged and is transferred to the replacement product.
3. Issue a refund of the original purchase price less depreciation to be determined based on the age of the product at the time remedy is sought under this limited warranty.
What Kramer Electronics Will Not Do Under This Limited Warranty
If this product is returned to Kramer Electronics or the authorized dealer from which it was purchased or any other party authorized to repair Kramer Electronics products, this product must be insured during shipment, with the insurance and shipping charges prepaid by you. If this product is returned uninsured, you assume all risks of loss or damage during shipment. Kramer Electronics will not be responsible for any costs related to the removal or re­installation of this product from or into any installation. Kramer Electronics will not be responsible for any costs related to any setting up this product, any adjustment of user controls or any programming required for a specific installation of this product.
How to Obtain a Remedy Under This Limited Warranty
To obtain a remedy under this limited warranty, you must contact either the authorized Kramer Electronics reseller from whom you purchased this product or the Kramer Electronics office nearest you. For a list of authorized Kramer Electronics resellers and/or Kramer Electronics authorized service providers, visit our web site at www.kramerav.com or contact the Kramer Electronics office nearest you. In order to pursue any remedy under this limited warranty, you must possess an original, dated receipt as proof of purchase from an authorized Kramer Electronics reseller. If this product is returned under this limited warranty, a return authorization number, obtained from Kramer Electronics, will be required (RMA number). You may also be directed to an authorized reseller or a person authorized by Kramer Electronics to repair the product. If it is decided that this product should be returned directly to Kramer Electronics, this product should be properly packed, preferably in the original carton, for shipping. Cartons not bearing a return authorization number will be refused.
Limitation of Liability
THE MAXIMUM LIABILITY OF KRAMER ELECTRONICS UNDER THIS LIMITED WARRANTY SHALL NOT EXCEED THE ACTUAL PURCHASE PRICE PAID FOR THE PRODUCT. TO THE MAXIMUM EXTENT PERMITTED BY LAW, KRAMER ELECTRONICS IS NOT RESPONSIBLE FOR DIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM ANY BREACH OF WARRANTY OR CONDITION, OR UNDER ANY OTHER LEGAL THEORY. Some countries, districts or states do not allow the exclusion or limitation of relief, special, incidental, consequential or indirect damages, or the limitation of liability to specified amounts, so the above limitations or exclusions may not apply to you.
Exclusive Remedy
TO THE MAXIMUM EXTENT PERMITTED BY LAW, THIS LIMITED WARRANTY AND THE REMEDIES SET FORTH ABOVE ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, REMEDIES AND CONDITIONS, WHETHER ORAL OR WRITTEN, EXPRESS OR IMPLIED. TO THE MAXIMUM EXTENT PERMITTED BY LAW, KRAMER ELECTRONICS SPECIFICALLY DISCLAIMS ANY AND ALL IMPLIED WARRANTIES, INCLUDING, WITHOUT LIMITATION, WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IF KRAMER ELECTRONICS CANNOT LAWFULLY DISCLAIM OR EXCLUDE IMPLIED WARRANTIES UNDER APPLICABLE LAW, THEN ALL IMPLIED WARRANTIES COVERING THIS PRODUCT, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, SHALL APPLY TO THIS PRODUCT AS PROVIDED UNDER APPLICABLE LAW. IF ANY PRODUCT TO WHICH THIS LIMITED WARRANTY APPLIES IS A “CONSUMER PRODUCT” UNDER THE MAGNUSON-MOSS WARRANTY ACT (15 U.S.C.A. §2301, ET SEQ.) OR OTHER APPLICABLE LAW, THE FOREGOING DISCLAIMER OF IMPLIED WARRANTIES SHALL NOT APPLY TO YOU, AND ALL IMPLIED WARRANTIES ON THIS PRODUCT, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR THE PARTICULAR PURPOSE, SHALL APPLY AS PROVIDED UNDER APPLICABLE LAW.
Other Conditions
This limited warranty gives you specific legal rights, and you may have other rights which vary from country to country or state to state. This limited warranty is void if (i) the label bearing the serial number of this product has been removed or defaced, (ii) the product is not distributed by Kramer Electronics or (iii) this product is not purchased from an authorized Kramer Electronics reseller. If you are unsure whether a reseller is an authorized Kramer Electronics reseller, visit our web site at www.kramerav.com or contact a Kramer Electronics office from the list at the end of this document. Your rights under this limited warranty are not diminished if you do not complete and return the product registration form or complete and submit the online product registration form. Kramer Electronics thanks you for purchasing a Kramer Electronics product. We hope it will give you years of satisfaction.
Page 23
www.KramerAV.com info@KramerAV.com
P/N:
2900-301020
Rev:
1
SAFETY WARNING
Disconnect the unit from the power supply before opening and servicing
For the latest information on our products and a list of Kramer distributors, visit our Web site where updates to this user manual may be found.
We welcome your questions, comments, and feedback.
The terms HDMI, HDMI High-Definition Multimedia Interface, and the HDMI Logo are trademarks or registered trademarks of HDMI Licensing Administrator, Inc. All brand names, product names, and trademarks are the property of their respective owners.
Loading...