Kramer KT-205WM User Manual

Page 1
P/N: 2900-301657 Rev 4 www.kramerav.com
USER MANUAL
KT-205WM
5.5" Touch Panel
Page 2
Kramer Electronics Ltd.
KT-205WM – Contents
2
Contents
Contents 2 Introduction 3
Getting Started 3 Overview 5
Defining KT-205WM 5.5" Touch Panel 6
On-Wall Mount 7
Mounting the KT-205WM 8
Mounting KT-205WM on a Wall 8 Connection Options 9
Controlling KT-205WM 10
Using Navigation Buttons or Gestures 10 Using the Home Page 11 Exiting or Starting the Kramer Control app 11
Basic Settings of KT-205WM 12
Essential First Steps 12 Setting the Date and Time 12 Connecting to Wi-Fi or Ethernet 13 Installing an 802.1X Certificate 14 Changing the Automated Firmware Update 15 Changing the Automated Kramer Control Agent Update 17 Setting the Display and Keyboard Language 18
Using the Kramer Control agent (connecting to Brain) 19
Entering the Control Interface IP & Port Number 19 The Kramer Control Agent Settings 20 Using the Kramer Control Agent’s API 22 Methods of Setting the Control Interface URL 24
Advanced Settings 28
Factory Reset & Reboot 28 Logging Activity 29
Technical Specifications 30
Page 3
Kramer Electronics Ltd.
KT-205WM – Introduction
3
Introduction
Welcome to Kramer Electronics! Since 1981, Kramer Electronics has been providing a world of unique, creative, and affordable solutions to the vast range of problems that confront the video, audio, presentation, and broadcasting professional on a daily basis. In recent years, we have redesigned and upgraded most of our line, making the best even better!
Getting Started
We recommend that you:
Unpack the equipment carefully and save the original box and packaging materials for possible future shipment.
Review the contents of this user manual.
Go to www.kramerav.com/downloads/KT-205WM to check for up-to-date user manuals, application programs, and to check if firmware upgrades are available (where appropriate).
Achieving Best Performance
Use only good quality connection cables (we recommend Kramer high-performance, high-resolution cables) to avoid interference, deterioration in signal quality due to poor matching, and elevated noise levels (often associated with low quality cables).
Do not secure the cables in tight bundles or roll the slack into tight coils.
Avoid interference from neighboring electrical appliances that may adversely influence signal
quality.
Position your Kramer KT-205WM away from moisture, excessive sunlight and dust.
Recycling Kramer Products
The Waste Electrical and Electronic Equipment (WEEE) Directive 2002/96/EC aims to reduce the amount of WEEE sent for disposal to landfill or incineration by requiring it to be collected and recycled. To comply with the WEEE Directive, Kramer Electronics has made arrangements with the European Advanced Recycling Network (EARN) and will cover any costs of treatment, recycling and recovery of waste Kramer Electronics branded equipment on arrival at the EARN facility. For details of Kramer’s recycling arrangements in your particular country go to our recycling pages at www.kramerav.com/social-responsibility/environment.
Page 4
Kramer Electronics Ltd.
KT-205WM – Introduction
4
Safety Instructions
This unit is intended to be supplied by:
UL / IEC 62368-1 certified PoE output power supply suitable for use at an ambient temperature of 40°C and an altitude of 2,000 m whose output meets ES1, and is rated 44-57 V DC, minimum 0.3 A.
UL / IEC 62368-1 certified Class II power adapter suitable for use at an ambient temperature of 40°C and an altitude of 2,000 m whose output meets ES1, and is rated 12 V DC, minimum 1.0 A.
Caution:
This equipment is to be used only inside a building. It may only be connected to other equipment that is installed inside a building.
For products with relay terminals and GPI\O ports, please refer to the permitted rating for an external connection, located next to the terminal or in the User Manual.
There are no operator serviceable parts inside the unit.
Risk of explosion if the battery is replaced by an incorrect type. Wait one-half hour after switching off
before handling parts.
Warning:
If not using PoE, use only the optional power cord that is supplied for the unit.
Do not open the unit. High voltages can cause electrical shock! Servicing by qualified personnel
only.
Laser Safety:
This product complies with FDA performance standards for laser products except for conformance with IEC 60825-1 Ed. 3., as described in Laser Notice No. 56, dated May 8, 2019.
Date of manufacture: The date code shown at the bottom of the product label represents the manufacturing date of this laser product.
CAUTION: Invisible laser radiation when open. Avoid exposure to beam. Class 1 laser product. This system must be opened only by qualified technicians to prevent accidents caused by the laser beam. CAUTION: Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure.
The ambient light sensor can automatically adjust panel brightness based on the environment. See Display Settings to enable automatic brightness. The Laser proximity sensor will detect nearby motion to wake the panel up without requiring a touch.
Page 5
Kramer Electronics Ltd.
KT-205WM – Introduction
5
Overview
Congratulations on purchasing your Kramer KT-205WM 5.5" Touch Panel.
KT-205WM is a new powerful, 5.5 inch, IPS, multi−touch, touch panel with 720x1280 resolution.
Elegantly designed for wall-mounted decorative room integration.
KT-205WM runs the latest Android 11, supports wired PoE (Power over Ethernet) and advanced
Wi−Fi connectivity options. The touch panel has a built−in speaker and camera and comes with a
wall mount. The touch panel is easy to assemble, with elegant wiring and secured mounting providing reliable operation and flexible deployment.
KT-205WM touch panel is ideal for any 24/7 Kramer-supported commercial AV or control
applications and features a user−friendly, fully customizable graphical user interface configured by Kramer software.
Exceptional Quality
Superior User Experience – IPS 720x1280 hiresolution screen with ±80° horizontal and vertical wide viewing angles, ambient light sensor and proximity sensor with advanced 10 multi–touch points and 2–finger gesture capabilities.
Powerful Processing – i.MX8M Plus Quad Core A53, 4GB RAM, 32GB ROM processing performance, smoothly running complicated media and graphics–rich applications, such as H.265 video and audio stream encoding and decoding.
Flexible Services – Latest Android 11 operating system.
Advanced and User-friendly Operation
Easy Installation – Powering and connectivity via a single Ethernet cable.
Optional Connectivity – Wireless Bluetooth 5 and connection to USB peripheral devices.
Reliable Networking – Seamless switching between wired and wireless 802.11ac
connectivity.
Versatile Powering Options – PoE or power adapter (sold separately).
Auto Sensing – Optimized performance and operation according to automatically detected
LAN speed.
Firmware Upgrade – Define automatic updates at a predefined time of day or update manually using the USB port.
Typical Applications
KT-205WM is ideal for controlling user interfaces in meeting and conference rooms, boardrooms,
and auditoriums.
Page 6
Kramer Electronics Ltd.
KT-205WM – Defining KT-205WM 5.5" Touch Panel
6
Defining KT-205WM 5.5" Touch Panel
This section defines KT-205WM.
Figure 1: KT-205WM 5.5" Touch Panel
#
Feature
Function
Home Button
Press to wake up / darken the screen.
Recessed Restart Button
Located on the top-side. Insert a pin and hold for a few seconds to restart.
Restore Factory Reset Button
Insert a pin and hold for 22 seconds to reset the device to factory default values.
Micro USB Port
For connecting to an adjacent on-wall USB device and for firmware upgrade.
12V/1A DC Connector
Connect to the power adapter (optional, purchased separately).
LAN 1G(PoE) RJ-45 Port
Connect to the LAN for network communication.
KT-205WM is powered by PoE (power over ethernet) delivered through
the LAN port. Optionally, you can connect the power adapter too (as backup).
Display
Touch panel.
Light Sensor
Automatically adjusts the screen brightness according to the room lighting conditions.
Microphone
For audio communication, recording or conferencing.
Speaker
To output the sound.
1 2 3 4 5 6 7
8 9 10
Page 7
Kramer Electronics Ltd.
KT-205WM – Defining KT-205WM 5.5" Touch Panel
7
On-Wall Mount
Figure 2: On Wall Mount
#
Feature
Function
Screw Opening
For securing the 5.5" Touch Panel to the wall mount bracket using the supplied M2.5 screw.
M3.2 Screw Opening
For securing the wall mount bracket to the gang box.
M3.2 Screw Opening
For securing the wall mount bracket to the gang box.
11
12
13
Page 8
Kramer Electronics Ltd.
KT-205WM – Mounting the KT-205WM
8
Mounting the KT-205WM
Always be careful when attaching or removing the 5.5" Touch Panel from a mount.
Mounting KT-205WM on a Wall
To mount the device on a wall:
KT-205WM can only be mounted in portrait mode.
1. Install an in-wall gang box.
2. Attach the wall mount bracket to the installed gang box (top side up: see the indication arrows on the bracket), using two M3.2 screws provided.
The wall mount bracket works with UK, EU and US single gang boxes. Screws are provided for all
configurations.
3. Connect Ethernet and/or power cables and optionally, insert the micro-USB cable (supplied) for connecting to an adjacent external USB device.
4. Rest KT-205WM on the wall mount bracket:
a) Line up the top holders and the bottom mounting
screw hole.
b) Push the touch panel down, snapping the top
holders into place.
5. Insert one M2.5 screw below the touch panel and secure the touch panel to the wall mount bracket.
Page 9
Kramer Electronics Ltd.
KT-205WM – Mounting the KT-205WM
9
Connection Options
Connect KT-205 to power using one or both of the following options:
1. Connect the PoE-enabled LAN RJ-45 connector to your local area PoE-enabled network.
2. Connect the power adapter to the 12V DC connector on the rear side. The power adapter is optional: It can be purchased separately.
When both PoE and the power supply are connected to the touch panel, the unit is powered by the power supply.
Figure 3: Powering the Touch Panel
Page 10
Kramer Electronics Ltd.
KT-205WM – Controlling KT-205WM
10
Controlling KT-205WM
Using Navigation Buttons or Gestures
By default, KT-205WM runs the Kramer Control agent and displays its login screen at start-up. You can also use navigation buttons displayed at the bottom of the screen or setup your device to use gesture-based navigation.
Using navigation buttons
Swipe a finger upwards from the line at the bottom of the screen and release to see the navigation buttons:
- Back – Returns to the previous screen (or opens the home page if there is none).
- Home – Opens the home page, see Using the Home Page on page 11.
- Recent apps – Scroll between the active apps.
Changing the navigation system
By default, navigation buttons are used, however the touch panel can be set to use gesture navigation instead.
To change the navigation method:
1. If the touch panel is running the Kramer Control agent, exit the Kramer Control agent by entering the PIN (default 9428). If the PIN button is not displayed, swipe up from the Kramer icon at the bottom of the screen to bring up the PIN entry pop-up.
2. On the Home page, press Settings . The device’s Settings menu opens.
3. Select Advanced settings > System.
4. In the System menu, press Gestures and then System navigation.
5. Select Gesture navigation or 3-button navigation. If you are using Gesture navigation, the sensitivity is adjustable.
Using Gesture navigation
Back – Drag a finger inwards from the left or right edge of the screen.
Home – Swipe a finger upwards from the line at the bottom of the screen and release.
Recent apps – Swipe a finger upwards from the line at the bottom of the screen and hold.
Hiding the Navigation Bar
To hide/unhide the navigation bar:
1. On the Home page, press the Settings button . The device’s Settings menu opens.
2. In the Settings menu, open Player settings and enable Fullscreen mode.
Page 11
Kramer Electronics Ltd.
KT-205WM – Controlling KT-205WM
11
Using the Home Page
Swipe a finger upwards from the line at the bottom of the screen and release to see the navigation buttons:
- Home – Opens the home page.
The Home page contains the following icons:
- Chromium browser
- Touch panel settings
- Kramer Control Agent
Exiting or Starting the Kramer Control app
KT-205WM comes with a Kramer Control agent (icon ) pre-installed app. The role of this app
is to display an interface that you defined in Kramer Control. When the touch panel starts, the Kramer Control agent runs automatically. To exit the Kramer
Control agent, enter the PIN (default 9428). If the PIN button is not displayed, swipe up from the Kramer icon at the bottom of the screen to bring up the PIN entry pop-up.
To re-open the Control Agent click the icon on the Home page. During initial installation the k-agent app may need to be started manually the first time.
Page 12
Kramer Electronics Ltd.
KT-205WM – Basic Settings of KT-205WM
12
Basic Settings of KT-205WM
Essential First Steps
To exit the Kramer Control agent, enter the PIN (default 9428). If the PIN button is not displayed, swipe up from the bottom of the screen to bring up the PIN entry pop-up.
To re-open the Control Agent click the icon on the Home page. The following are essential first steps in using the touch panel:
1. Set the device date and time; Setting the Date and Time on page 12.
2. Setup the Ethernet and/or Wi-Fi connections; Connecting to Wi-Fi or Ethernet on page 13.
3. Consider changing the time that the system checks for firmware (OS) updates;
Changing the Automated Firmware Update on page 15. By default, this is set to midnight,
change it if you have no internet access at midnight or prefer another time.
4. Consider changing the time that the system checks for Kramer Control (APK) updates;
Changing the Automated Kramer Control Agent Update on page 17. By default, this is set to
midnight, change it if you have no internet access at midnight or prefer another time.
5. Setup the Kramer Control agent’s Launch URL; See Using the Kramer Control agent
(connecting to the Brain) on page 19.
6. Change the display language (if necessary); Setting the Display and Keyboard Language on page 18.
Setting the Date and Time
The device arrives preset to New York time and you will need to set the correct time region.
To adjust the date and time settings:
1. If necessary, swipe up from the bottom of the screen to bring up the PIN entry pop-up and enter the PIN (default 9428).
2. On the Home page, press the Settings button . The device’s Settings menu opens.
3. Select Date & Time > Time zone.
4. Set the correct Region. The time will display correctly.
Page 13
Kramer Electronics Ltd.
KT-205WM – Basic Settings of KT-205WM
13
Connecting to Wi-Fi or Ethernet
Connect an Ethernet cable to the device or activate Wi-Fi and setup a connection to your Wi-Fi. If multiple network connections are used, Ethernet will be prioritized over any others.
If you are using 802.1X authentication, do Installing an 802.1X Certificate on page 14, before you connect to the internet.
Connecting Ethernet
Ethernet connections must be plugged into the back of the device, see  in Defining KT-205WM
5.5" Touch Panel on page 6. By default, the IP address of the device is set automatically by a
DHCP server.
Enabling 802.1X Authentication
1. Do Installing an 802.1X Certificate on page 14.
2. In the Settings screen, select Network & Internet > Ethernet.
3. Make sure the Ethernet is disabled and then enable Security.
802.1X authentication cannot be applied to active Ethernet connections
4. Select 802.1X settings and input the EAP (Extensible Authentication Protocol) information.
802.1X authentication is enabled.
Using a Static IP Address
1. If necessary, swipe up from the bottom of the screen to bring up the PIN entry pop-up and enter the PIN (default 9428).
2. From the Home page, open the Settings screen .
3. In the Settings screen, select Network & Internet > Ethernet.
4. Press Ethernet IP mode and select Static.
5. Enter the IP information and press Connect.
The static IP address is setup.
Connecting Wi-Fi
Enabling 802.1X Authentication
1. Do Installing an 802.1X Certificate on page 14.
2. From the Home page, open the Settings screen .
3. In the Settings screen, select Network & Internet > Wi-Fi.
4. Make sure Use Wi-Fi is enabled. The device will scan and list the Wi-Fi networks.
5. Select a Wi-Fi SSID, check Advanced options and enter the Wi-Fi information in the fields that appear, then press Connect.
6. If you are using 802.1X authentication, then add the certificate information.
802.1X is enabled.
Page 14
Kramer Electronics Ltd.
KT-205WM – Basic Settings of KT-205WM
14
Installing an 802.1X Certificate
802.1X certificates enhance the security of network authentication. KT-205WM support .pem, .pfx and .p12 certificate formats.
Installing a certificate is a two-stage process: First import the certificate, then set it up.
Importing an 802.1X Certificate
1. Copy the certificate file to an empty USB flash drive.
2. If necessary, swipe up from the bottom of the screen to bring up the PIN entry pop-up and enter the PIN (default 9428).
3. From the Home page, open the Settings screen .
4. Select Advanced settings > Security > Encryption & credentials.
Figure 4: The path to Install from storage
5. In the Encryption & credentials screen, select Install from storage: The Install a certificate screen opens.
6. Select the Wi-Fi certificate: The Recent files screen opens. To browse to the file location, press the 3 lines at the top left of the screen.
7. Select the credentials file and install it, some certificates require you to know a password.
An 802.1X certificate is imported.
Setting up an 802.1X Certificate
1. In the Settings screen, select Network & Internet > Wi-Fi.
2. Select Install from storage: The Install a certificate screen opens.
3. Select Wi-Fi certificate (also for Ethernet connections): The Recent files screen opens. To browse to the file location, press the 3 lines at the top left of the screen.
802.1X certificate is set.
After installing the certificates, see Connecting to Wi-Fi or Ethernet on page 13 for instructions on using the certificates. Ethernet must be disabled before setting-up Ethernet certificates.
Page 15
Kramer Electronics Ltd.
KT-205WM – Basic Settings of KT-205WM
15
Changing the Automated Firmware Update
KT-205 arrives preset to check for firmware (touch panel OS) updates at midnight. If an update is
found, the device will download the update file and install it. If you prefer to run manual updates, you must manually download the update file and then install it in the touch panel.
Changing the Time of the Firmware’s Automated Update
1. If necessary, swipe up from the bottom of the screen to bring up the PIN entry pop-up and enter the PIN (default 9428).
2. From the Home page, open the Settings screen .
3. Select Firmware update and then select Remote firmware upgrade URL. Remote firmware upgrade URL is the site from which the firmware is downloaded. The upgrade URL (case sensitive):
https://cdn.kramerav.com/web/apk/transformer-Kramer-AndroidR.xml
Figure 5: The Firmware update page
4. A pop-up opens, inviting you to set the check time:
Figure 6: The Remote firmware upgrade URL page
5. To change the time that the system checks for updates, press Set check time and select a new time.
6. Press OK to close the window and then press SET.
Changing (or clearing) the URL will disable the updates.
The time of the automated firmware check is set.
Page 16
Kramer Electronics Ltd.
KT-205WM – Basic Settings of KT-205WM
16
Manually Updating the Firmware
Manual firmware updates require a downloaded firmware file from Kramer. The firmware upgrade process requires:
An empty USB flash drive to store the firmware file.
A micro-USB OTG (on the go) cable to connect the USB flash drive to the touch panel.
Access to the back of the touch panel.
You may need to remove the touch panel from its mount for this purpose. The touch panel should remain connected to a power source such as PoE or the optional power adapter (see
in Defining KT-205WM 5.5" Touch Panel on page 6).
To upgrade the firmware:
1. Download the firmware update file from the Kramer website at
www.kramerav.com/product/KT-205WM.
Verify that you are using the correct KT-205WM firmware file as there maybe more than
one firmware file available.
Do not unzip the firmware update file.
2. Copy the firmware file to an empty USB flash drive.
3. On the touch panel, open the Settings screen .
4. Select Firmware update and then select Firmware update (again).
5. Plug the USB flash drive into a micro-USB OTG cable and connect the cable to the back of the touch panel.
6. Click START FIRMWARE UPDATE.
The firmware update will then begin.
Page 17
Kramer Electronics Ltd.
KT-205WM – Basic Settings of KT-205WM
17
Changing the Automated Kramer Control Agent Update
KT-205 arrives preset to check for updates to the Kramer Control Agent at midnight every day. If
an update is found, the device will download the update file and install it.
Changing the time of the automated APK update check
1. If necessary, swipe up from the bottom of the screen to bring up the PIN entry pop-up and enter the PIN (default 9428).
2. From the Home page, open the Settings screen .
3. Select Remote APP upgrade URL. Remote APP upgrade URL is the site from which the APK is downloaded. The upgrade URL (case sensitive) is:
https://cdn.kramerav.com/web/apk/remote_app_update.xml
4. A pop-up opens, inviting you to set the check time:
Figure 7: The Remote APP upgrade URL page
5. Press Set check time to select a new time.
6. Press OK to close the window and then press SET.
Changing (or clearing) the URL will disable the updates.
The time of the automated APK update check is changed.
Page 18
Kramer Electronics Ltd.
KT-205WM – Basic Settings of KT-205WM
18
Setting the Display and Keyboard Language
To set your preferred interface language:
1. If necessary, swipe up from the bottom of the screen to bring up the PIN entry pop-up and enter the PIN (default 9428).
2. From the Home page, open the Settings screen .
3. Select Language & input.
4. Select Languages.
5. Press Add a language to select a language.
6. If you are using multiple languages, the order in which they are listed represents the priority assigned to them, change the order by dragging languages.
The keyboard language has been set.
Page 19
Kramer Electronics Ltd.
KT-205WM – Using the Kramer Control agent (connecting to Brain)
19
Using the Kramer Control agent (connecting to Brain)
The KT-205WM touch panel contains a Kramer Control agent (an app), that downloads and displays a user-designed customized interface from Kramer Control Brain. The customized interface can control all aspects of the meeting space. For more information about Kramer Brain, see www.kramerav.com/product/KT-205WM.
Figure 8: Example of a touch panel interface menu
When the touch panel starts, the Kramer Control agent runs automatically (it is pre-installed on KT-205WM). If an interface has been defined, it will be displayed. If not, it will display the Kramer Agent welcome screen where you can enter the interface’s IP.
Entering the Control Interface IP & Port Number
On the first run, the Kramer Control app requests the IP & port number of the customized Brain interface to be displayed. The hardware section of the builder’s Brain Info contains the URL (in the format IP:port#) of the customized Brain interface. If more than one interface is defined in the
Brain, the Brain’s IP and port must be followed by two parameters: /?Interface=<interface
ID>&page=<page ID>. See also Methods of Setting the Control Interface IP on page 24.
Figure 9: Interface IP Address
Kramer Control Brain port numbers
The IP and port number (and a code on SL-240 / SL-280) are entered in the format IP:port#.
1. Kramer SL-240 or SL-280: Port 8000.
2. KC-Virtual Brain 1: Port 8001.
3. KC-Virtual Brain 5: Ports 8001 – 8005 (KC-Virtual Brain 5 can define up to 5 different touch pad control interfaces, each will use a different port).
Page 20
Kramer Electronics Ltd.
KT-205WM – Using the Kramer Control agent (connecting to Brain)
20
The Kramer Control Agent Settings
By default, the Kramer Agent’s Welcome
screen (Settings) appears the first time the touch panel runs.
To open the Settings: Slide your finger from the top to the
bottom of the screen or vice versa.
The Kramer Agent has 3 settings:
1. Control Interface
2. Display Policy
3. Lock Tablet
Figure 10: Kramer Agent Welcome screen
Press each setting to see more options (described below).
Use the sliders to enable/disable a setting.
These settings can also be set by API calls. See Using the Kramer Agent’s API on page 22.
1. Control Interface
Press Control Interface to set the interface IP and Immersive mode.
Control Interface (slider) After entering the IP of the Control Interface, move the slider to activate the interface and exit the pop-up.
Figure 11: Control Interface options
Launch URL Enter the IP of the Control Interface or a webpage URL you want displayed on the touch panel. For more options see Methods of Setting the Control Interface IP on page 24.
Kramer Control (check box) By default, the Kramer Control box is checked, setting the tablet in Immersive Mode: In Immersive (full screen) mode, the system bars are hidden, and users must swipe up/down and enter a PIN to exit the Control Interface. If you are using a generic webpage (such as www.google.com), Immersive mode must be disabled.
2. Display Policy
Press Display Policy to view more options.
Display Policy (slider) Move the slider to activate the policy.
Set Default Brightness Level This is the % of maximum brightness that the touch panel will return to when the display is re- activated.
Figure 12: Display Policy options
Page 21
Kramer Electronics Ltd.
KT-205WM – Using the Kramer Control agent (connecting to Brain)
21
Display Timeout (Timer) Dimming – The minutes of inactivity, before dimming to 20% of maximum brightness. Display Off – The minutes of inactivity, before switching off the display (must be longer than the dimming timeout).
3. Lock Tablet (and USB)
Enable/disable the PIN that restricts access to the Kramer Control agent and USB. Press Lock Tablet to change the PIN and view more options. USB locking is optional.
Lock Tablet (slider) Move the slider to activate the locking policy defined below.
PIN to Unlock screen 9428 is the default value. Enter a new PIN to change the value.
USB Lock – Check this box for the tablet lock policy to also disable the tablet’s USB port.
Figure 13: Lock Tablet options
Page 22
Kramer Electronics Ltd.
KT-205WM – Using the Kramer Control agent (connecting to Brain)
22
Using the Kramer Control Agent’s API
The API changes Kramer Control agent settings remotely, without using the touch panel.
Note:
The touch panel must be switched on and connected to the same LAN.
If more than one interface is defined in the Brain, the Brain’s IP and port must be
followed by two parameters: /?Interface=<interface ID>&page=<page ID>. See example 2 below.
Example: Setting the Launch URL in the Control Agent
a) Open a browser window on a computer connected to the same network as the touch panel. b) Example: To set the Launch URL in the Kramer Control agent (on the touch panel), use the
following format:
https://<IP of the touch panel>:9804/launchkramerurl?<IP of the brain interface>:<port #>
Example 1 (single interface defined in Brain):
If the touch panel IP is “192.168.0.56” and the Brain interface IP is “192.168.22.53:8001”,
enter https://192.168.0.56:9804/launchkramerurl?192.168.22.53:8001 Example 2 (multiple interfaces defined in Brain):
The URL must include the full interface ID and page. Touch panel IP is “192.168.0.56” and the Brain interface IP is “192.168.2.53:8001/?interface=e84f5fb8-c5a3-4675-9006-
d79d3e6cfe59&page=5913c07a-9a41-4fac-9870-e87b1ef719df”. Enter
https://192.168.0.56:9804/launchkramerurl?192.168.2.53:8001/?interface=e84f5fb8­c5a3-4675-9006-d79d3e6cfe59&page=5913c07a-9a41-4fac-9870-e87b1ef719df
Note: Use port 9803 if the touch panel uses http and port 9804 if it uses https. After this command is sent, the touch panel will display the Brain-defined interface. See the next page for a full list of API commands.
Page 23
Kramer Electronics Ltd.
KT-205WM – Using the Kramer Control agent (connecting to Brain)
23
The following API commands can be sent to the touch panel from a browser:
Function
Command structure
Status response
(in browser)
Check if the Control agent is running
https://<IP of the touch panel>:9804/health/
“up”
Reboot the touch panel
https://<IP of the touch panel>:9804/reboot/
“Rebooting”
Pause the Control Interface and return to k-agent settings
https://<IP...>:9804/pauselaunchautourl/
URL launched is paused, Move to Main View
Resume the Control Interface
https://<IP...>l:9804/resumelaunchautourl/
“URL launched is
resumed”
Clear the Control Interface’s
URL setting
https://<IP...>:9804/reseturl/
“URL is reset now”
Set the Control Interface URL (immersive mode). *
https://<IP...>:9804/launchkramerurl?<IP of the interface>:<port#>
“Browser will be
launched with given URL.”
Define a generic URL (touch panel display a non-Brain URL such as www.google.com
https://<IP...>:9804/launchurl?<full generic URL>
“Browser will be
launched with given URL.”
Enable/disable display control
https://<IP…>:9804/displaysettingon
(or displaysettingoff)
Set the timeout to turn off the display after 4 minutes inactivity
https://<IP...>:9804/setdisplayofftimevalue=4
Set the timeout to dim the display after 2 minutes inactivity
https://<IP...>:9804/setdisplaydimtime=2
Set the display brightness in %
https://<IP...>:9804/setdisplaybrightnessvalue=100
Figure 14: Example of a successful response message.
*
If more than one interface is defined in the Brain, the Brain’s IP and port must be followed
by two parameters: /?Interface=<interface ID>&page=<page ID>.
For example:
https://192.168.0.56:9804/launchkramerurl?192.168.2.53:8001/?interface=e84f5fb8-c5a3-
4675-9006-d79d3e6cfe59&page=5913c07a-9a41-4fac-9870-e87b1ef719df
Page 24
Kramer Electronics Ltd.
KT-205WM – Using the Kramer Control agent (connecting to Brain)
24
Methods of Setting the Control Interface URL
When the touch panel starts, the (pre-installed) Kramer Control agent runs automatically. You will need to set up its connection with the Kramer Brain, so that it can display the desired control interface.
There are 3 possible methods of setting the interface IP in the Kramer Control agent:
1. In the Kramer Control agent (on the touch panel screen).
2. Using the API (on a remote computer connected to the same network).
3. In the Brain software (setting up the touch panel in the Brain software).
Any one of these methods can load the interface URL into the touch panel’s Kramer Control agent.
1. Entering the interface IP in the Kramer Control agent
a. Kramer Control agent opens
automatically when the touch panel starts. If no interface IP has been entered, the Kramer Agent’s Welcome screen is displayed:
If the touch panel is not displaying the Welcome screen, open the Kramer Agent app from the
touch panel’s Home page and it
will be displayed.
b. Press Control Interface; the Launch
URL pop-up appears.
Figure 15: The Kramer Agent Welcome screen
c. Enter the IP address and port of the
interface that was defined in Kramer Brain, for example
https://192.168.88.180:8001.
If more than one interface is defined in the
Brain, the Brain’s IP and port must be
followed by two parameters: /?Interface=<interface ID>&page=<page ID>.
Figure 16: The Launch URL pop-up
See also Finding the Control Interface IP on page 19 and Example of Setting the Launch
URL on page 22.
d. By default, the Kramer Control box is checked, setting the tablet in Immersive Mode: In
Immersive (full screen) mode, the system bars are hidden, and users can only exit the interface by swiping up and entering a PIN. Immersive mode is recommended for the Kramer
Control interface; Disable it if you are using a generic webpage (such as www.google.com). e. Press OK and the touch panel will load your interface. f. To exit the Control Interface and access touch panel controls, slide your fingers up from the
bottom of the screen and enter the PIN (default 9428).
Page 25
Kramer Electronics Ltd.
KT-205WM – Using the Kramer Control agent (connecting to Brain)
25
2. Controlling the Kramer Control agent by API call
This method of changing settings of the Kramer Control interface can be done remotely, without using the touch panel. For more information see Using the Kramer Control Agent’s API on page 22.
Note: The touch panel must be switched on and connected to the same LAN.
a) Open a browser window on a computer connected to the same network as the touch panel. b) To set the IP of the Control Interface displayed by the Call the touch panel in the following
format:
https://<IP of the touch panel>:9804/launchkramerurl?<IP of the brain interface>:<port #>
Example 1 (single interface defined in Brain):
If the touch panel IP is “192.168.0.56” and the Brain interface IP is “192.168.22.53:8001”,
enter https://192.168.0.56:9804/launchkramerurl?192.168.22.53:8001
Example 2 (multiple interfaces defined in Brain):
The URL must include the full interface ID and page. Touch panel IP is “192.168.0.56”
and the Brain interface IP is “192.168.2.53:8001/?interface=e84f5fb8-c5a3-4675-9006-
d79d3e6cfe59&page=5913c07a-9a41-4fac-9870-e87b1ef719df”. Enter
https://192.168.0.56:9804/launchkramerurl?192.168.2.53:8001/?interface=e84f5fb 8-c5a3-4675-9006-d79d3e6cfe59&page=5913c07a-9a41-4fac-9870-e87b1ef719df
After this command is sent, the touch pad will display the Brain-defined interface and a status response message returned to the sender.
Figure 17: Example of a successful response message.
Page 26
Kramer Electronics Ltd.
KT-205WM – Using the Kramer Control agent (connecting to Brain)
26
3. Setup the touch panel in the Brain Builder
The advantage of this method is that future changes to the interface are automatically uploaded to the tablet.
The following assumes that:
a) The interface is already setup in the Brain. b) The touch panel is active and connected to the same network as the Brain. c) The IP of the touch panel is static and DHCP assigned.
1. Preliminary Setup: In the Devices tab of the Builder screen, add the K-Agent driver as a device. It must be assigned to the same network gateway as the touch panel.
2. Navigate to the Brain control page on your computer.
3. Select the interface that you want to use on the touch panel.
4. Copy the interface’s URL from the address bar (see the image below).
5. Navigate back to the Builder, double click on the touch panel (in the Devices list) and paste the URL from the previous step to the Kramer Control URL. Assign it a Friendly Name.
Figure 18: Kramer Control URL in the Builder
6. For the Brain to be able to automatically assign the user interface to the touch panel: (see the image on the next page)
a) In the Events tab, click System Events and select “Initialization”. b) Drag the Launch Kramer URL command to the ‘Initialization’ ACTIONS area. c) Select the Friendly Name (If only one interface is defined, it will be used by default).
Page 27
Kramer Electronics Ltd.
KT-205WM – Using the Kramer Control agent (connecting to Brain)
27
Figure 19: System Events window open on Initialization actions
7. Every time the Brain reboots or connects to the touch panel the interface will be updated.
Page 28
Kramer Electronics Ltd.
KT-205WM – Advanced Settings
28
Advanced Settings
Factory Reset & Reboot
The Settings > Reset options menu enables you to perform a factory reset or to reboot the device, reset Wi-Fi or Bluetooth or reset app preferences.
Resetting to Factory Default Parameters
To reset the device to its factory default settings:
1. If necessary, swipe up from the bottom of the screen to bring up the PIN entry pop-up and enter the PIN (default 9428).
2. From the Home page, open the Settings screen .
3. Select Reset options > Erase all data (factory reset).
4. Press Erase all data. Other options available are Reboot device, Reset Wi-Fi, mobile & Bluetooth and Reset app
preferences.
Resetting with the External Reset Button
Insert a pin into the pinhole on the back  (see Defining KT-205WM 5.5" Touch Panel on page 6) and hold for 22 seconds to reset the device to factory default values.
A second pinhole on the top  restarts the device when a pin is inserted for a few seconds.
Page 29
Kramer Electronics Ltd.
KT-205WM – Advanced Settings
29
Logging Activity
By default, the device does not log activity. Logging can be useful for debugging or monitoring use.
Activating Logging
To activate logging:
1. If necessary, swipe up from the bottom of the screen to bring up the PIN entry pop-up and enter the PIN (default 9428).
2. From the Home page, open the Settings screen .
3. Select Log > Log Location and select one of Store to internal storage, Store to SD card or Do not store.
Logging is activated.
Accessing an Internally Stored Log File
A USB flash drive and OTG cable are required to copy an internally stored log file.
To access an internally stored log file:
1. In the root directory of the flash drive, create a folder called “_dump_debug_log”.
2. Connect the OTG cable to the micro-USB connection on the back of the device.
3. Connect the flash drive to the OTG cable.
4. The device will automatically download the log file to the USB device and issue a confirmation message “Saved log file to USB storage”.
The log is accessed.
Page 30
Kramer Electronics Ltd.
KT-205WM – Technical Specifications
30
Technical Specifications
Ports 1 Micro USB
On a Micro USB (AB) OTG connector
1 Ethernet
On an RJ-45 female connector, 10/100/1000M with PoE 802.3at
Platform Operating System
Android Version 11
CPU
ARM Quad Core Cortex-A53 up to 1.8Ghz (64 bit)
Memory RAM
LPDDR4 4GB
Internal
32GB eMMC (flash)
Display
Touch Panel Type
Multi-touch
Size
5.5”
Resolution
720x1280 RGB pixels 350cd/m2 brightness, 1000:1 contrast ratio
Wireless Connectivity
Wi-Fi
Wi-Fi 6, 802.11 a/b/g/n/ax/ax
Bluetooth
BT 5.0
Video Video Formats
H.264, H.265, VC-1, MPEG-4, VP8, VP9
Image Codecs
JPEG, BMP, GIF, PNG
Audio
Speakers
1x 1W
Codecs
MPEG, OGG, AAC
Microphone
2 built-in.
Power PoE (Power over
Ethernet)
44 to 57V DC 0.3A Complies with IEEE 802.3af PoE standard
Optional Power Adapter
12V DC 1.0 A Note: Operating temperature: 0~40°C
Controls
Restart
On top, recessed
Restore factory settings
On back, recessed
Home
In top
LED
Side-light
Can indicate room status (requires 3rd party integration).
Environmental conditions
Operating Temperature
0~40°C (32~104°F)
Storage Temperature
-20~60°C
Operating Humidity
5% to 85%
Storage Humidity
5% to 90%
Regulatory Compliance
Safety
CE, FCC, UL, UKCA
Environmental
RoHs, WEEE
Dimensions Touch Panel (W,D,H)
81mm x 25mm x 143mm / 3.15” x 0.98” x 5.63”
Wall Mount
1 gang
Weight
Touch Panel
0.2kg / 0.4lbs (approximate)
Shipping carton Dimensions (W,D,H)
148mm x 78mm x 235mm / 5.83” x 3.07” x 9.25”
Weight
0.5kg / 1.1lbs (approximate)
Accessories Optional
Power adapter.
Included
On-wall mount unit and screws
Specifications are subject to change without notice at www.kramerav.com
Page 31
Kramer Electronics Ltd.
KT-205WM – Technical Specifications
31
The warranty obligations of Kramer Electronics Inc. (“Kramer Electronics”) for this product are limited to the terms set forth below:
What is Covered
This limited warranty covers defects in materials and workmanship in this product.
What is Not Covered
This limited warranty does not cover any damage, deterioration or malfunction resulting from any alteration, modification, improper or unreasonable use or maintenance, misuse, abuse, accident, neglect, exposure to excess moisture, fire, improper packing and shipping (such claims must be presented to the carrier), lightning, power surges, or other acts of nature. This limited warranty does not cover any damage, deterioration or malfunction resulting from the installation or removal of this product from any installation, any unauthorized tampering with this product, any repairs attempted by anyone unauthorized by Kramer Electronics to make such repairs, or any other cause which does not relate directly to a defect in materials and/or workmanship of this product. This limited warranty does not cover cartons, equipment enclosures, cables or accessories used in conjunction with this product. Without limiting any other exclusion herein, Kramer Electronics does not warrant that the product covered hereby, including, without limitation, the technology and/or integrated circuit(s) included in the product, will not become obsolete or that such items are or will remain compatible with any other product or technology with which the product may be used.
How Long this Coverage Lasts
The standard limited warranty for Kramer products is seven (7) years from the date of original purchase, with the following exceptions:
1. All Kramer VIA hardware products are covered by a standard three (3) year warranty for the VIA hardware and a standard three (3) year warranty for firmware and software updates; all Kramer VIA accessories, adapters, tags, and dongles are covered by a standard one (1) year warranty.
2. Kramer fiber optic cables, adapter-size fiber optic extenders, pluggable optical modules, active cables, cable retractors, ring mounted adapters, portable power chargers, Kramer speakers, and Kramer touch panels are covered by a standard one (1) year warranty. Kramer 7-inch touch panels purchased on or after April 1st, 2020 are covered by a standard two (2) year warranty.
3. All Kramer Calibre products, all Kramer Minicom digital signage products, all HighSecLabs products, all streaming, and all wireless products are covered by a standard three (3) year warranty.
4. All Sierra Video MultiViewers are covered by a standard five (5) year warranty.
5. Sierra switchers & control panels are covered by a standard seven (7) year warranty (excluding power supplies and fans that are covered for three (3) years).
6. K-Touch software is covered by a standard one (1) year warranty for software updates.
7. All Kramer passive cables are covered by a lifetime warranty.
Who is Covered
Only the original purchaser of this product is covered under this limited warranty. This limited warranty is not transferable to subsequent purchasers or owners of this product.
What Kramer Electronics Will Do
Kramer Electronics will, at its sole option, provide one of the following three remedies to whatever extent it shall deem necessary to satisfy a proper claim under this limited warranty:
1. Elect to repair or facilitate the repair of any defective parts within a reasonable period of time, free of any charge for the necessary parts and labor to complete the repair and restore this product to its proper operating condition. Kramer Electronics will also pay the shipping costs necessary to return this product once the repair is complete.
2. Replace this product with a direct replacement or with a similar product deemed by Kramer Electronics to perform substantially the same function as the original product. If a direct or similar replacement product is supplied, the original product’s end warranty date remains unchanged and is transferred to the replacement product.
3. Issue a refund of the original purchase price less depreciation to be determined based on the age of the product at the time remedy is sought under this limited warranty.
What Kramer Electronics Will Not Do Under This Limited Warranty
If this product is returned to Kramer Electronics or the authorized dealer from which it was purchased or any other party authorized to repair Kramer Electronics products, this product must be insured during shipment, with the insurance and shipping charges prepaid by you. If this product is returned uninsured, you assume all risks of loss or damage during shipment. Kramer Electronics will not be responsible for any costs related to the removal or re-installation of this product from or into any installation. Kramer Electronics will not be responsible for any costs related to any setting up this product, any adjustment of user controls or any programming required for a specific installation of this product.
How to Obtain a Remedy Under This Limited Warranty
To obtain a remedy under this limited warranty, you must contact either the authorized Kramer Electronics reseller from whom you purchased this product or the Kramer Electronics office nearest you. For a list of authorized Kramer Electronics resellers and/or Kramer Electronics authorized service providers, visit our web site at www.kramerav.com or contact the Kramer Electronics office nearest you. In order to pursue any remedy under this limited warranty, you must possess an original, dated receipt as proof of purchase from an authorized Kramer Electronics reseller. If this product is returned under this limited warranty, a return authorization number, obtained from Kramer Electronics, will be required (RMA number). You may also be directed to an authorized reseller or a person authorized by Kramer Electronics to repair the product. If it is decided that this product should be returned directly to Kramer Electronics, this product should be properly packed, preferably in the original carton, for shipping. Cartons not bearing a return authorization number will be refused.
Limitation of Liability
THE MAXIMUM LIABILITY OF KRAMER ELECTRONICS UNDER THIS LIMITED WARRANTY SHALL NOT EXCEED THE ACTUAL PURCHASE PRICE PAID FOR THE PRODUCT. TO THE MAXIMUM EXTENT PERMITTED BY LAW, KRAMER ELECTRONICS IS NOT RESPONSIBLE FOR DIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM ANY BREACH OF WARRANTY OR CONDITION, OR UNDER ANY OTHER LEGAL THEORY. Some countries, districts or states do not allow the exclusion or limitation of relief, special, incidental, consequential or indirect damages, or the limitation of liability to specified amounts, so the above limitations or exclusions may not apply to you.
Exclusive Remedy
TO THE MAXIMUM EXTENT PERMITTED BY LAW, THIS LIMITED WARRANTY AND THE REMEDIES SET FORTH ABOVE ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, REMEDIES AND CONDITIONS, WHETHER ORAL OR WRITTEN, EXPRESS OR IMPLIED. TO THE MAXIMUM EXTENT PERMITTED BY LAW, KRAMER ELECTRONICS SPECIFICALLY DISCLAIMS ANY AND ALL IMPLIED WARRANTIES, INCLUDING, WITHOUT LIMITATION, WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IF KRAMER ELECTRONICS CANNOT LAWFULLY DISCLAIM OR EXCLUDE IMPLIED WARRANTIES UNDER APPLICABLE LAW, THEN ALL IMPLIED WARRANTIES COVERING THIS PRODUCT, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, SHALL APPLY TO THIS PRODUCT AS PROVIDED UNDER APPLICABLE LAW. IF ANY PRODUCT TO WHICH THIS LIMITED WARRANTY APPLIES IS A “CONSUMER PRODUCT” UNDER THE MAGNUSON -MOSS WARRANTY ACT (15 U.S.C.A. §2301, ET SEQ.) OR OTHER APPLICABLE LAW, THE FOREGOING DISCLAIMER OF IMPLIED WARRANTIES SHALL NOT APPLY TO YOU, AND ALL IMPLIED WARRANTIES ON THIS PRODUCT, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR THE PARTICULAR PURPOSE, SHALL APPLY AS PROVIDED UNDER APPLICABLE LAW.
Other Conditions
This limited warranty gives you specific legal rights, and you may have other rights which vary from country to country or state to state. This limited warranty is void if (i) the label bearing the serial number of this product has been removed or defaced, (ii) the product is not distributed by Kramer Electronics or (iii) this product is not purchased from an authorized Kramer Electronics reseller. If you are unsure whether a reseller is an authorized Kramer Electronics reseller, visit our web site at www.kramerav.com or contact a Kramer Electronics office from the list at the end of this document. Your rights under this limited warranty are not diminished if you do not complete and return the product registration form or complete and submit the online product registration form. Kramer Electronics thanks you for purchasing a Kramer Electronics product. We hope it will give you years of satisfaction.
Page 32
www.kramerav.com info@kramerav .com
P/N:
2900-301657
Rev:
4
SAFETY WARNING
Disconnect the unit from the power supply before opening and servicing
For the latest information on our products and a list of Kramer distributors, visit our website where updates to this user manual may be found.
We welcome your questions, comments, and feedback.
The terms HDMI, HDMI High-Definition Multimedia Interface, and the HDMI Logo are trademarks or registered trademarks of HDMI Licensing Administrator, Inc. All brand names, product names, and trademarks are the property of their respective owners.
Loading...