Figure 1: FC-70R RS-232 to USB Converter 5
Figure 2: Connecting the FC-70R RS-232 to USB Converter 6
Page 3
FC-70R - Introduction
1
1
1 Introduction
Welcome to Kramer Electronics! Since 1981, Kramer Electronics has been
providing a world of unique, creative, and affordable solutions to the vast range of
problems that confront video, audio, presentation, and broadcasting professionals
on a daily basis. In recent years, we have redesigned and upgraded most of our
line, making the best even better!
Our 1,000-plus different models now appear in 14 groups that are clearly defined by
function: GROUP 1: Distribution Amplifiers; GROUP 2: Switchers and Routers;
GROUP 3: Control Systems; GROUP 4: Format/Standards Converters; GROUP 5:
Range Extenders and Repeaters; GROUP 6: Specialty AV Products; GROUP 7:
Scan Converters and Scalers; GROUP 8: Cables and Connectors; GROUP 9:
Room Connectivity; GROUP 10: Accessories and Rack Adapters; GROUP 11:
Sierra Video Products; GROUP 12: Digital Signage; GROUP 13: Audio; and
GROUP 14: Collaboration.
Congratulations on purchasing your Kramer FC-70R RS-232 to USB Converter.
This product is used to control HSL secured products and is ideal for:
High-security organizations
Government, military and financial branches
Any organization that handles sensitive and confidential information
Page 4
2
FC-70R - Getting Started
Go to www.kramerav.com/downloads/FC-70R to check for up-to-date user
manuals, application programs, and to check if firmware upgrades are
available (where appropriate).
This equipment is to be used only inside a building. It may only be
connected to other equipment that is installed inside a building.
Caution:
There are no operator serviceable parts inside the unit
Warning:
Use only the Kramer Electronics power supply that is
provided with the unit
Warning:
Disconnect the power and unplug the unit from the wall
before installing
2 Getting Started
We recommend that you:
Unpack the equipment carefully and save the original box and packaging
materials for possible future shipment
Review the contents of this user manual
2.1 Achieving the Best Performance
To achieve the best performance:
Use only good quality connection cables (we recommend Kramer high-
performance, high-resolution cables) to avoid interference, deterioration in
signal quality due to poor matching, and elevated noise levels (often
associated with low quality cables)
Do not secure the cables in tight bundles or roll the slack into tight coils
Avoid interference from neighbouring electrical appliances that may adversely
influence signal quality
Position your FC-70R away from moisture, excessive sunlight and dust
2.2 Safety Instructions
Page 5
FC-70R - Getting Started
3
3
2.3 Recycling Kramer Products
The Waste Electrical and Electronic Equipment (WEEE) Directive 2002/96/EC aims
to reduce the amount of WEEE sent for disposal to landfill or incineration by
requiring it to be collected and recycled. To comply with the WEEE Directive,
Kramer Electronics has made arrangements with the European Advanced
Recycling Network (EARN) and will cover any costs of treatment, recycling and
recovery of waste Kramer Electronics branded equipment on arrival at the EARN
facility. For details of Kramer’s recycling arrangements in your particular country go
to our recycling pages at www.kramerav.com/support/recycling/.
Page 6
4
FC-70R - Overview
3 Overview
FC-70R is a protocol translator from RS-232 to USB signals to allow remote control
of HSL secure and non-secure products. HSL products are controlled using
keyboard, mouse and touch display (KVM combiners). FC-70R translates RS-232
control commands to enable remote control on secured KVM and KVM combiners.
The FC-70R features:
Enhanced Usability & Remote Control - Operates with HSL secure KVM, KM
and Combiner products.
Easy and Intuitive User Interface - Graphical user interface when connected
to Kramer control.
Remote Switching - When connected to Kramer Control or Kramer RC
devices.
Standards Compliance - Maintains ELA4+ and PPSV3.0 of HighSecLabs
products.
Connection Ports - Connects to HSL products via the USB port and to an
external controller via the RS−232 port.
USB Powered – Powered from the USB line. No power supply needed.
Page 7
FC-70R - Overview
5
5
#
Feature
Function
1
RS-232 Terminal Block
Connects to a control device
2
USB-B Connector
Connects to a KVM or KVM combiner being controlled
3
ON LED
Lights when the device is powered on
4
MOUSE USB-A Connector
Connects to a USB mouse
5
KB USB-A Connector
Connects to a USB keyboard
3.1 Defining the FC-70R RS-232 to USB Converter
This section defines the FC-70R.
Figure 1: FC-70R RS-232 to USB Converter
Page 8
6
FC-70R - Connecting the FC-70R
Always switch off the power to each device before connecting it to
your FC-70R. After connecting the devices to your FC-70R, connect
its power and then switch on the power to each device.
4 Connecting the FC-70R
To connect the FC-70R, as illustrated in the example in Figure 2, do the following:
1. Connect the USB-B connector on the back of the FC-70R to the USB
keyboard connection of the KVM or KVM combiner.
The FC-70R receives power over this connection.
2. Using an RS-232 cable, connect a control device (for example, an SL-1N) to
the RS-232 3-pin terminal block.
3. Connect a keyboard and mouse to the USB-A connectors.
Figure 2: Connecting the FC-70R RS-232 to USB Converter