KRAMER FC-6 kramer-fc-6-um-3.pdf

USER MANUAL
MODEL:
FC-6
Ethernet Gateway - RS-232/IR
P/N: 2900-300585 Rev 3
www.kramerAV.com
Contents
1 Introduction 1 2 Getting Started 2
2.1 Achieving the Best Performance 2
2.2 Safety Instructions 2
2.3 Recycling Kramer Products 3
3 Overview 4 4 Defining the FC-6 Ethernet Gateway - RS-232/IR 6 5 Performing Initial Configuration 8
5.1 Configuring the FC-6 Ethernet Gateway - RS-232/IR 8
5.2 Setting Up an Ethernet Connection on the PC 10
6 Connecting the FC-6 11
6.1 Connecting via Ethernet 12
7 Remote Operation via the Web UI 17
7.1 Browsing the Web UI 17
7.2 Displaying Connected Clients 19
7.3 Setting Device Name and Time Functions 20
7.4 Setting Communication Parameters 22
7.5 Setting Serial Port Parameters 23
7.6 Configuring IR Command Learning 24
7.7 Activating Security 25
7.8 Using the Logs Page 27
7.9 Kramer Information 28
8 Using FC-6 Operations 29
8.1 IR Learning 29
8.2 Resetting to the Factory Default Settings 30
8.3 Upgrading the Firmware 30
9 Technical Specifications 31
9.1 Data Handling Performance 32
9.2 Example Bandwidth Calculation 32
10 Default Communication Parameters 33 11 Kramer Protocol 3000 34
11.1 Kramer Protocol 3000 – Syntax 35
11.2 Kramer Protocol 3000 – Command List 38
11.3 Kramer Protocol 3000 – Detailed Commands 39
FC-6 – Contents i
Figures
Figure 1: FC-6 Controlled Devices from Remote IP-based Clients 5 Figure 2: FC-6 Ethernet Gateway - RS-232/IR 6 Figure 3: Connecting the FC-6 for Initial Configuration 8 Figure 4: Configuring a Remote Connection 10 Figure 5: Connecting the FC-6 Ethernet Gateway - RS-232/IR 11 Figure 6: Terminal Block Connections 12 Figure 7: Local Area Connection Properties Window 13 Figure 8: Internet Protocol Version 4 Properties Window 14 Figure 9: Internet Protocol Version 6 Properties Window 14 Figure 10: Internet Protocol Properties Window 15 Figure 11: General Info Page 18 Figure 12: Connected Clients Page 20 Figure 13: Device Settings Page 21 Figure 14: Communication Page 22 Figure 15: Serial Port Settings Page 23 Figure 16: IR Command Learner Page 24 Figure 17: Security Page 25 Figure 18: Security Confirmation Popup 25 Figure 19: Authentication Required Popup 26 Figure 20: Security Activated Page 26 Figure 21: Logs Page 27 Figure 22: About Us Page 28
ii FC-6 – Contents

1 Introduction

Welcome to Kramer Electronics! Since 1981, Kramer Electronics has been
providing a world of unique, creative, and affordable solutions to the vast range of
problems that confront video, audio, presentation, and broadcasting professionals
on a daily basis. In recent years, we have redesigned and upgraded most of our
line, making the best even better!
Our 1,000-plus different models now appear in 14 groups that are clearly defined by
function: GROUP 1: Distribution Amplifiers; GROUP 2: Switchers and Routers;
GROUP 3: Control Systems; GROUP 4: Format/Standards Converters; GROUP 5:
Range Extenders and Repeaters; GROUP 6: Specialty AV Products; GROUP 7:
Scan Converters and Scalers; GROUP 8: Cables and Connectors; GROUP 9:
Room Connectivity; GROUP 10: Accessories and Rack Adapters; GROUP 11:
Sierra Video Products; GROUP 12: Digital Signage; GROUP 13: Audio; and
GROUP 14: Collaboration.
Congratulations on purchasing your Kramer FC-6 Ethernet Gateway - RS-232/IR
that is ideal for:
Remote IP control of RS-232 and IR controlled devices
K-Touch multi-clients IP room control
LAN-based expansion of K-Config control system
FC-6 – Introduction 1
available (where appropriate).
Caution:
There are no operator serviceable parts inside the unit
provided with the unit
before installing

2 Getting Started

We recommend that you:
Unpack the equipment carefully and save the original box and packaging
materials for possible future shipment
Review the contents of this user manual
Go to www.kramerav.com/downloads/FC-6 to check for up-to-date user manuals, application programs, and to check if firmware upgrades are

2.1 Achieving the Best Performance

To achieve the best performance:
For optimum range and performance, use the recommended Kramer cables
available at www.kramerav.com/product/FC-6
Do not secure the cables in tight bundles or roll the slack into tight coils
Avoid interference from neighbouring electrical appliances that may adversely
influence signal quality
Position your FC-6 away from moisture, excessive sunlight and dust
This equipment is to be used only inside a building. It may only be connected to other equipment that is installed inside a building.

2.2 Safety Instructions

Warning: Use only the Kramer Electronics power supply that is
Warning: Disconnect the power and unplug the unit from the wall
2 FC-6 - Getting Started

2.3 Recycling Kramer Products

The Waste Electrical and Electronic Equipment (WEEE) Directive 2002/96/EC aims
to reduce the amount of WEEE sent for disposal to landfill or incineration by
requiring it to be collected and recycled. To comply with the WEEE Directive,
Kramer Electronics has made arrangements with the European Advanced
Recycling Network (EARN) and will cover any costs of treatment, recycling and
recovery of waste Kramer Electronics branded equipment on arrival at the EARN
facility. For details of Kramer’s recycling arrangements in your particular country go
to our recycling pages at www.kramerav.com/support/recycling/
.
FC-6 – Getting Started 3

3 Overview

The FC-6 is an RS−232/IR multi−function control gateway, capable of plug and play
deployment over a customer Ethernet LAN for remote bidirectional RS−232 and IR
emitter control of customer devices. Multiple control clients can be IP−connected to
the FC-6 control gateway for concurrent control of two RS−232 or four IR
controllable devices, such as AV scalers, video displays, audio amplifiers, and DVD
players.
This Ethernet to serial/IR gateway bridges the gap between Ethernet infrastructures
and serial or IR communication devices by offering bidirectional Ethernet to serial
and IR conversion. All setup and maintenance of the devices is done from built-in
Web pages that are accessible using any common Web browser.
The FC-6 features:
Dual-Function I/O Ports - Remote IP−Based control of any device connected to
the control gateway dual−function I/O ports, with selectable port configuration
to bidirectional RS−232 or IR control.
Multiple IP Connected Clients - Remotely connected over customer Ethernet
network that concurrently controls any devices connected to control gateway
I/O ports.
Easy & Reliable Installation:
Plug and Play IP installation with dynamic (DHCP) address resolution
and auto device discovery over existing LAN.
Resilient powering with USB and optional PSU (not included).
Compact, designed for piggy−back installation, such as behind a TV or
display with the ability to draw power over USB.
Remote Management - Built−in web UI for remote browser−based
management and support, by multiple IP−clients over existing LAN. Easy
firmware upgrades, either remotely via existing LAN, or locally via device USB
port.
Size - Pico TOOLS™ - Mount 4 units side-by-side in a 1U rack space with the
optional RK−4PT rack adapter.
4 FC-6 - Overview
Figure 1: FC-6 Controlled Devices from Remote IP-based Clients
For example, using Kramer K-Touch control software you can design advanced
room-control and automation systems that can be operated from iOS or Android
touch devices. K-Touch can be used to perform device discovery over the network
as the FC-6 is set to be a DHCP client by default.
You can use the Kramer LAN Configurator software to discover devices that are
attached to the network, including the FC-6.
FC-6 – Overview 5
1
IR Sensor
Sensor for IR learning
directly or via a LAN (see Section 6.1)
and blue LED IRP2 indicates Tx
10)
perform a local firmware upgrade
6
ON LED
Lights green when the unit is on
7
MODE DIP-switches (Port 1 and
Switch up for RS-232, switch down for IR (the
(down))
8
Port 1 and 2 I/O 3-pin Terminal
Each terminal block connects one bidirectional
4 Defining the FC-6 Ethernet Gateway - RS-
232/IR
This section defines the FC-6.
Figure 2: FC-6 Ethernet Gateway - RS-232/IR
# Feature Function
2 LAN RJ-45 Connector
Port 1 and 2 white (upper) and
3
blue LEDs
4 RESET Button
5 SERVICE Mini USB Connector
Port 2)
Block
9 5V DC Connector
6 FC-6 - Defining the FC-6 Ethernet Gateway - RS-232/IR
Connect to an IP client PC or other controller
Show the transmission status of port 1 and port 2: When set as RS-232, the white LED indicates Tx and blue LED indicates Rx When set as IR, the white LED indicates IRP1 Tx
Press and hold while cycling the device power to reset to factory default parameters, (see Section
Connects to a PC to supply power to the device or
default setting is port 1 RS-232 (up) and port 2 IR
RS-232 port or two IR outputs
Connect to the optional 5V DC power supply, center pin positive. Not needed when the device is supplied power by the USB connection
Flashes when
receiving data
Other serial
RS-485 for Port 3
Port IO Function
FC-6 Function Table
Terminal Block Connections IO Port
G P1 P2
Default
TCP Default Port [P1/P2]
Blue Activity LED Pair
Comment
RS-232
IR Ground IR1 IR2 5000
Ground Rx Tx 9600,8,N,1 5001/2
Key:
P1 / P2 – Port 1 / Port 2
Tx – Transmit, Rx– Receive
9600, 8, N, 1 – 9600 baud, 8-bits, no parity, 1 stop bit
IR
/ IR2 – IR Port 1 / IR Port 2
1
port is transmitting &
ON when ports are transmitting IR data
configurations via Web, including
FC-6 – Defining the FC-6 Ethernet Gateway - RS-232/IR 7

5 Performing Initial Configuration

This chapter provides an overview of the initial configuration of the FC-6 comprises:
Configuring the FC-6 (see Section 5.1
Configuring an Ethernet connection on the PC (see Section 5.2)
Figure 3: Connecting the FC-6 for Initial Configuration
)

5.1 Configuring the FC-6 Ethernet Gateway - RS-232/IR

Note: The FC-6 is shipped from the factory with DHCP enabled (off by default) and
a random IP address. To connect the FC-6 on first installation, you must identify the
IP address that was automatically assigned to the FC-6. To discover the IP address
of FC-6, use K-LAN Configurator, available for download from our website at
www.kramerav.com
.
To browse the FC-6 Web UI on taking the device out of the box (using the
default settings), use the default host name, (see Section 10
Use the default host name: FC-6-xxxx, where xxxx are the last four digits of the
serial number of the device.
8 FC-6 - Performing Initial Configuration
).
To configure the FC-6:
1. Connect the Ethernet port on the rear panel of FC-6 to a PC, either directly
or via a LAN, (see Section 6.1
2. Using a Web browser and the relevant IP address, browse the General Info
home page (see Figure 11
3. Click on Device Settings to browse to the Device Settings page, (see
Figure 13
4. Enter the time and date manually, or enter the Time server address for
automatic time and date synchronization.
5. Click Save Changes.
6. Click on Communication to browse to the Communication page, (see
Figure 14
7. Enter the IP address, mask and gateway for static IP addressing and Click
Set. We suggest a meaningful host name.
Note: If you have changed the IP address from the default setting, you must
reload the General Info home page again using the new IP address.
).
).
).
).
8. Click on Serial Ports Settings to browse to the Serial Port Settings page,
(see Figure 15
9. Associate the required serial ports with their corresponding TCP/UDP
settings.
10. For each associated serial port, enter the serial port configuration
parameters using the drop-down lists under Serial Configuration.
11. Click Save Changes.
12. If required, click on Security to browse to the Security page.
13. Click ON to activate security.
The user name and password credentials popup appears.
FC-6 – Performing Initial Configuration 9
).
14. Enter the required user name and password. (The default user name is
Admin and the password is Admin).

5.2 Setting Up an Ethernet Connection on the PC

If the control application can directly connect to the Ethernet driver, select the host
IP address and port number according to your FC-6 configuration, as illustrated in
Figure 4
.
Figure 4: Configuring a Remote Connection
10 FC-6 - Performing Initial Configuration
the power to each device.
i

6 Connecting the FC-6

Always switch off the power to each device before connecting it to your FC-6. After connecting your FC-6, connect its power and then switch on
Figure 5: Connecting the FC-6 Ethernet Gateway - RS-232/IR
To connect the FC-6 as illustrated in the example in Figure 5:
1. Connect the device to a LAN or PC via the RJ-45 Ethernet connector.
2. Set DIP-switch 1 up to select RS-232.
3. Set DIP-switch 2 down to select IR.
FC-6 – Connecting the FC-6 11
Connect an RS-232-controlled device, (for example, a projector) to terminal
block 1, according to the connections shown in Figure 6
Connect an IR device (for example, an emitter/blaster) to terminal block 2,
P1 (or P2), according to the connections shown in Figure 6
.
.
RS-232
i
Port IO Function
IR Ground IR1 IR2
Figure 6: Terminal Block Connections
4. If the FC-6 does not receive power from a USB power connection, connect
the device to the power supply and connect the power adapter to the mains
electricity (not shown in Figure 5
Note: You can connect up to four IR devices or up to two RS-232 devices if both
ports are used for each setting.
Terminal Block Connections
G P1 P2
Ground Rx Tx

6.1 Connecting via Ethernet

You can connect to the FC-6 via Ethernet using either of the following methods:
Directly to the PC using a crossover cable (see Section 6.1.1
Via a network hub, switch, or router, using a straight-through cable (see
Section 6.1.2
Note: If you want to connect via a router and your IT system is based on IPv6,
speak to your IT department for specific installation instructions.
)
).
)

6.1.1 Connecting the Ethernet Port Directly to a PC

You can connect the Ethernet port of the FC-6 directly to the Ethernet port on your
PC using a crossover cable with RJ-45 connectors.
This type of connection is recommended for identifying the FC-6 with the factory configured default IP address.
After connecting to the Ethernet port, configure your PC as follows:
1. Click Start > Control Panel > Network and Sharing Center.
2. Click Change Adapter Settings.
3. Highlight the network adapter you want to use to connect to the device and
click Change settings of this connection.
12 FC-6 - Connecting the FC-6
The Local Area Connection Properties window for the selected network
adapter appears as shown in Figure 7
.
Figure 7: Local Area Connection Properties Window
4. Highlight Internet Protocol Version 4 (TCP/IPv4) and click Properties.
The Internet Protocol Properties window relevant to your IT system appears
as shown in Figure 8 or Figure 9
FC-6 – Connecting the FC-6 13
.
Figure 8: Internet Protocol Version 4 Properties W indow
Figure 9: Internet Protocol Version 6 Properties W indow
14 FC-6 - Connecting the FC-6
5. Select Use the following IP Address for static IP addressing and fill in the
details as shown in Figure 10
For TCP/IPv4 you can use any IP address in the range 192.168.1.1 to
192.168.1.255 (excluding 192.168.1.39) that is provided by your IT
department.
.
Figure 10: Internet Protocol Properties Window
6. Click OK.
7. Click Close.

6.1.2 Connecting the Ethernet Port via a Network Hub or Switch

You can connect the Ethernet port of the FC-6 to the Ethernet port on a network
hub or switch using a straight-through cable with RJ-45 connectors.
FC-6 – Connecting the FC-6 15

6.1.3 Connecting to the FC-6 via RS-232 or IR

To connect to the FC-6 via RS-232:
Connect the RS-232, 3-pin, terminal block connectors on the rear panel of the
FC-6 using 3-wire cable (pin TX to pin 2, RX to pin 3, and G to pin 5) to the RS-
232 9-pin D-sub port on the devices to be controlled
To connect to the FC-6 via IR:
Connect an IR blaster to one of the IR Outputs and place it within 4m to 8m (13
to 26ft) and in line-of-sight of the device to be controlled
—OR—
Connect an IR emitter cable to one of the IR Outputs and stick the emitter to
the IR sensor on the device to be controlled
16 FC-6 - Connecting the FC-6

7 Remote Operation via the Web UI

The embedded Web UI can be used to remotely operate the FC-6 using a Web
browser and an Ethernet connection.
Before attempting to connect:
Perform the initial configuration in Section 5.1
Section 6.1
Ensure that your browser is supported (see Section 9)

7.1 Browsing the Web UI

To browse the Web UI pages:
1. Open your Internet browser. Type the IP address of the device (see Section
5.1) in the Address bar of your browser.
The Loading page appears followed shortly by the General Info page shown in
Figure 11
The General Info page displays the following:
Model Name
Firmware version
Device serial number
Web UI version
.
and connecting via Ethernet in
FC-6 – Remote Operation via the Web UI 17
Figure 11: General Info Page
Loading and Saving Configurations
Loading and saving configurations is used for duplicating multiple device definitions
for easy system configuration. The configurations are loaded and saved to a local
PC. Load and save is performed using the buttons at the bottom left-hand side of
the screen for all pages displayed.
To load a configuration:
1. Click Load.
The Explorer window opens.
2. Browse to the required file.
3. Select the required file and click Open.
The device is configured according to the saved preset.
18 FC-6 - Remote Operation via the Web UI
UI Page
Parameter
Sync Every Day time
TCP Port
Send Replies to New Client by Default
To save the current configuration:
1. Configure the device as required.
2. Click Save.
The Save File window opens.
3. Browse to the required location to save the file.
4. Enter the required name for the saved preset.
5. Click OK.
The current configuration is saved.
Note: When using Chrome, the file is automatically saved in the Downloads folder.
The following parameters are saved to the configuration file:
Device Settings (Figure 7.3) Model Name
Communication (Figure 7.4) UDP Port
Serial Port Setting (Figure7.5) Serial Port
Time Zone Daylight Savings Time mode Use Time Server mode Time Server Address
Protocol IP Port TCP Keep Alive Parity Data Bits Baud Rate Stop Bits

7.2 Displaying Connected Clients

The Connected Clients page (Figure 12) allows you to view the following details of
any client devices connected via Ethernet to the FC-6:
IP address
Its connection port
FC-6 – Remote Operation via the Web UI 19
Method of connection
Whether or not Send Replies is enabled for the port
Figure 12: Connected Clients Page

7.3 Setting Device Name and Time Functions

The Device Settings page (Figure 13) allows you to view the model name and time
server status. You can also modify the following fields:
Device name
Device time, date, and time zone
Use a timeserver to set the time and date automatically using a (if the device is
connected to the Internet), including the Time Zone and daylight savings time
20 FC-6 - Remote Operation via the Web UI
Figure 13: Device Settings Page
The FC-6 has a built-in clock that can synchronize with a Time Server if required.
To enable Time Server synchronization:
1. Browse to the Device Settings page by clicking Device Settings.
The Device Settings page is displayed as shown in Figure 13
.
2. Click the Use Time Server ON button.
3. Enter the IP address of the Time Server.
4. Enter the time of day FC-6 synchronizes with the Time Server.
5. Click Save Changes.
FC-6 – Remote Operation via the Web UI 21

7.4 Setting Communication Parameters

The communication page allows you to:
Turn DHCP for the device on and off
Edit the IP settings for static IP addressing
Note: The default IP address setting for the device is DHCP.
Figure 14: Communication Page
After modifying any of the IP settings, click Set to save the changes.
22 FC-6 - Remote Operation via the Web UI

7.5 Setting Serial Port Parameters

The Serial Port Settings page allows you to:
Set the following Ethernet parameters for each Ethernet port:
Select TCP or UDP
IP port label
TCP keep-alive time
TCP keep alive time – 0-3600sec (default 60sec) internal time, after
which detected idle connection is disconnected
Set the following serial parameters for each serial port:
Parity
Data bits
Baud rate
Stop bits
Select whether or not to send replies on the port to the new client
Figure 15: Serial Port Settings Page
FC-6 – Remote Operation via the Web UI 23
Feature
Function
Learning Timeout
Set the time to elapse before the learning mode is exited if no command is received
Start Learning Button
Press to start the l earning process.
light and the FC-6 is not available for normal operation.
Spinner
press the Test button to start the test
Button
Clear/Copy Buttons
Press to clear or copy the command received
Press Load to retrieve a previously saved command. Press Save to save the current command

7.6 Configuring IR Command Learning

The IR Command Learner page allows you to teach the FC-6 IR commands. These
can be saved for later use.
Note: While learning is in progress, the four IR Out LEDS light and the FC-6 is not
available for normal operation.
Figure 16: IR Command Learner Page
Command Name Field Enter the required name for the command
Command Received Window
Test Button and Port Selection
Retrieve Last Command
Load/Save Buttons
24 FC-6 - Remote Operation via the Web UI
Note: While learning is in progress, the four IR Out LEDS
Displays the command string received during the process. This command can be copied/pasted to another application
Select the port on which to test the learned command and
Press to retrieve that last command learned

7.7 Activating Security

The Security page allows you to turn logon authentication on or off.
Figure 17: Security Page
When security is on, access to the Web pages is granted only on submission of a
valid user and password. The default user ID is Admin and the password is Admin.
To activate Web page security:
1. On the Security page, click ON.
The confirmation popup is displayed as shown in Figure 18
Figure 18: Security Confirmation Popup
2. Click OK.
The Authentication Required popup is displayed as shown in Figure 19
FC-6 – Remote Operation via the Web UI 25
.
.
Figure 19: Authentication Required Popup
3. Enter the default username and password.
4. Click OK.
5. Wait until the Web UI has reloaded. Click the Security tab.
The page show in Figure 20
is displayed.
Figure 20: Security Activated Page
6. If required, click OFF to turn security off, or change the password and click
Change.
26 FC-6 - Remote Operation via the Web UI

7.8 Using the Logs Page

The Logs page allows you to:
View current logs
Configure the logs
Filter the logs
Figure 21: Logs Page
The display may not update automatically. Click Refresh to update the display.
Use the Log Filter check-boxes to select which events to display from the log. Use
the Log Config check-boxes to select which events are recorded.
FC-6 – Remote Operation via the Web UI 27

7.9 Kramer Information

The About Us page displays the Web page version and the Kramer company
details.
Figure 22: About Us Page
28 FC-6 - Remote Operation via the Web UI

8 Using FC-6 Operations

This section explains how to use IR learning, reset the device and upgrade device
firmware.

8.1 IR Learning

At the start and end of learning a message is sent to all attached clients.
To perform IR learning, the IR remote control must be approximately five to seven
centimeters (2” and 2.7”) from the FC-6 front panel.
Note: While learning is in progress, the FC-6 is not available for normal operation.
To teach the FC-6 an IR command:
1. Put the FC-6 in IR Learning mode either by sending the Protocol 3000
command, (see Section 11.2) or by using the Web pages, (see Section 7.6
The device is no longer in normal operation, and the FC-6 sends an IR
Learning start message to all connected clients.
).
2. Using the IR remote control, send the required command to the FC-6.
The FC-6 processes the IR detected signal and generates the signal-
associated pronto code to be used by the driver. When using the Web page
for IR learning, the FC-6 also displays the learned command code on
screen. (This command can be copied/pasted to other applications, for
example, control software when creating a driver.) The FC-6 then sends the
IR Learning stop message to all connected clients to indicate return to
normal operation.
3. Optional—Test the command if using the IR Learning Web page.
Test results are displayed on screen.
4. Save the learned command.
FC-6 – Using FC-6 Operations 29

8.2 Resetting to the Factory Default Settings

To reset the device to its factory default settings:
1. Turn off the power to the device.
2. Press and hold the Reset button on the front panel.
3. Turn on the power to the device while holding down the Reset button for a
few seconds.
4. Release the button.
The device is reset to the factory default settings.

8.3 Upgrading the Firmware

For instructions on upgrading the firmware see the “Kramer K-Upload User
Manual”.
30 FC-6 - Using FC-6 Operations
2 RS-232 bidirectional serial or
1 mini USB connector
For programming
1200, 2400, 4800, 9600, 19200, 38400, 57600, 15200bps
RS-232 communication
Transparent up to 115200bps
IR
IR emitter cable range
80m (260ft)
IR output frequencies
20kHz to 1.2MHz
IR input frequencies
20kHz to 60kHz
Maximum data handling of device
Up to 150kbps (summed on all ports, see
Section 9.1)
Maximum simultaneous IP-client connections
40 Power
Power consumption
5V DC, 300mA Operating temperature
0° to +40°C (32° to 104°F)
Storage temperature
–40° to +70°C (–40° to 158°F)
Humidity
10% to 90%, RHL non-condensing
Safety
CE
Environmental
RoHs, WEEE
Enclosure type
Aluminum
Net dimensions
6.22cm x 5.18cm x 2.44cm (2.45" x 2.0" x
1.0") W, D, H.
Net weight
0.084kg (3.0ozs) approx.
W, D, H.
Shipping weight
0.43kg (0.94lbs) approx.
Included
3ft USB cable, bracket set
5V DC power adapter,
www.kramerav.com/product/FC-6

9 Technical Specifications

Ports
Serial Serial port baud rates
Data and Connections
Cooling Convection ventilation
Environmental Conditions
Regulatory Compliance Vibration
General
4 IR (selectable)
1 LAN
1 IR sensor
On 3-pin terminal blocks
On an RJ-45 connector
For IR learning
ISTA 1A in carton (International Safe Transit Association)
Accessories
Specifications are subject to change without notice at www.kramer av.com
FC-6 – Technical Specifications 31
Shipping dimensions
Optional
15.7cm x 12cm x 8.7cm (6.2" x 4.7" x 3.4")
19“ rack adapter, IR and serial cables – see

9.1 Data Handling Performance

The FC-6 is designed to support mainly AV-relevant RS-232 communication.
These devices must have overall data bandwidth limits high enough in most AV
installations to support the required communication bandwidth.
In extremely demanding cases, we recommend that you take into account the
bandwidth limitations.
The total sustained data bandwidth that each device can handle for all ports
simultaneously is 150kbps.

9.2 Example Bandwidth Calculation

The FC-6 has two serial ports. Each serial port can support up to:
150kbps / 2 = 75kbps
If each protocol command is 100 bytes, (that is, 800 bits), you can safely send and
receive a minimum of 96 commands per second on each serial port. This is shown
using the following calculation:
(150kbps * 1024) / 800 bits / 2 = 96
The same calculation applies to all devices. A similar calculation applies when
fewer ports are used at the same time where a higher bandwidth per port can be
achieved.
In critical applications requiring a lossless data transfer, we recommend that
communication on all the other ports is stopped when making a long file transfer (for
example, when performing a firmware upgrade via one of the serial ports).
32 FC-6 - Technical Specifications
RS-232
Protocol 3000
Baud Rate:
115200
Data Bits:
8
Stop Bits:
1
Parity:
None
Ethernet
DHCP:
Off
IP Address:
192.168.1.39
FC-6-xxxx
number of the device
Subnet Mask:
255.255.0.0
Gateway:
192.168.0.1
TCP Device Port
5000
TCP Serial Port 1:
5001
TCP Serial Port 2:
5002
UDP Device Port:
50000
Web Page Access
User name:
Admin
Password:
Admin

10 Default Communication Parameters

Note: The FC-6 is shipped from the factory with DHCP enabled (off) and a random
IP address. After performing a factory reset, the DHCP and the IP address are set
to the values shown below.
Host Name:
where xxxx are the last four digits of the serial
Default Logon Authentication
FC-6 – Default Communication Parameters 33

11 Kramer Protocol 3000

The FC-6 can be operated using the Kramer Protocol 3000 serial commands. The
command framing varies according to how you interface with the FC-6. For
example, a basic video input switching command that routes a layer 1 video signal
to HDMI out 1 from HDMI input 2 (ROUTE 1,1,2), is entered as follows:
Terminal communication software, such as Hercules:
The framing of the command varies according to the terminal communication software.
K-Touch Builder (Kramer software):
34 FC-6 - Kramer Protocol 3000
Start
Address (optional)
Body
Delimiter
#
Destination_id@
Message
CR
Start
Body
Delimiter
Command SP
CR
Start
Address
Body
Delimiter
Command_3 Parameter3_1,Parameter3_2,…|…
K-Config (Kramer configuration software):
All the examples provided in this section are based on using the K-Config software.
You can enter commands directly using terminal communication software (e.g.,
Hercules) by connecting a PC to the serial or Ethernet port on the FC-6. To enter
CR press the Enter key (LF is also sent but is ignored by the command parser).
Commands sent from various non-Kramer controllers (e.g., Crestron) may require
special coding for some characters (such as, /X##). For more information, refer to
your controller’s documentation.

11.1 Kramer Protocol 3000 – Syntax

11.1.1 Host Message Format

11.1.1.1 Simple Command
Command string with only one command without addressing:
#
11.1.1.2 Command String
Formal syntax with commands concatenation and addressing:
# Destination_id@
FC-6 – Kramer Protocol 3000 35
Parameter_1,Parameter_2,…
Command_1 Parameter1_1,Parameter1_2,…| Command_2 Parameter2_1,Parameter2_2,…|
CR
Start
Address (optional)
Body
Delimiter
CR LF
Start
Address (optional)
Body
Delimiter
~
@
Command SP [Param1 ,Param2 …] result
CR LF

11.1.2 Device Message Format

~ Sender_id@ Message
11.1.2.1 Device Long Response
Echoing command:
Sender_id
CR = Carriage return (ASCII 13 = 0x0D) LF = Line feed (ASCII 10 = 0x0A) SP = Space (ASCII 32 = 0x20)

11.1.3 Command Terms

Command
A sequence of ASCII letters ('A'-'Z', 'a'-'z' and '-').
Command and parameters must be separated by at least one space.
Parameters
A sequence of alphanumeric ASCII characters ('0'-'9','A'-'Z','a'-'z' and some special
characters for specific commands). Parameters are separated by commas.
Message string
Every command entered as part of a message string begins with a message
starting character and ends with a message closing character.
Note: A string can contain more than one command. Commands are separated by
a pipe ( '|' ) character.
Message starting character
'#' – For host command/query
'~' – For device response
Device address (Optional, for K-NET)
K-NET Device ID followed by '@'
Query sign
'?' follows some commands to define a query request.
36 FC-6 - Kramer Protocol 3000
Message closing character
CR – For host messages; carriage return (ASCII 13)
CRLF – For device messages; carriage return (ASCII 13) + line-feed (ASCII 10)
Command chain separator character
When a message string contains more than one command, a pipe ( '|' ) character
separates each command.
Spaces between parameters or command terms are ignored.

11.1.4 Entering Commands

You can directly enter all commands using a terminal with ASCII communications
software, such as HyperTerminal, Hercules, etc. Connect the terminal to the serial
or Ethernet port on the Kramer device. To enter CR press the Enter key.
( LF is also sent but is ignored by command parser).
For commands sent from some non-Kramer controllers like Crestron, some
characters require special coding (such as, /X##). Refer to the controller manual.

11.1.5 Command Forms

Some commands have short name syntax in addition to long name syntax to allow
faster typing. The response is always in long syntax.

11.1.6 Chaining Commands

Multiple commands can be chained in the same string. Each command is delimited
by a pipe character (“|”). When chaining commands, enter the message starting
character and the message closing character only once, at the beginning of the
string and at the end.
Commands in the string do not execute until the closing character is entered.
A separate response is sent for every command in the chain.

11.1.7 Maximum String Length

64 characters
FC-6 – Kramer Protocol 3000 37
Command
Description
#
Protocol handshaking
BUILD-DATE
Read device build date
COM-ROUTE
Set/get tunneling port routing
COM-ROUTE-ADD
Add communication route tunnel connection
COM-ROUTE-REMOVE
Remove communication route tunnel connection
DEL
Deletes a file
DIR
List files
ETH-PORT
Sets protocol port
ETH-TUNNEL
Get parameters for open tunnels
FACTORY
Restart the machine with the default
FORMAT
Format the file system
FS-FREE
Print free file space
GET
Get file content
HELP
List of commands
LOGIN
Set/get protocol permission
LOGOUT
Demotes the terminal security level to minimum
MACH-NUM
Set device ID
MODEL
Read device model
NAME
Set/get device (DNS) name
NAME-RST
Reset device name to default
NET-DHCP
Set/get DHCP mode
NET-GATE
Set/get gateway IP
NET-IP
Set/get device IP address
NET-MAC
Get the MAC address
NET-MASK
Set/get the device subnet mask
PASS
Set/get the password for login level
PORT-LOCK
Set/get the port lock state
PORT-TYPE
Set/get the port type
PROT-VER
Get protocol version
RESET
Reset device
SECUR
Set/get current security state
SN
Get device serial number
TIME
Set/get the time
TIME-LOC
Set/get local time offset from UTC/GMT
TIME-SRV
Set/get time synchronization from server
UART
Set/get a port serial parameters
VERSION
Get firmware version number

11.2 Kramer Protocol 3000 – Command List

38 FC-6 - Kramer Protocol 3000
#
Description
Syntax
#CR
Response
~nn@SP OKCR LF
Response Triggers
K-Config Example
“#”,0x0D
Functions
Permission
Transparency
Set: - -
-
BUILD-DATE?
Description
Syntax
#BUILD-DATE?CR
Response
~nn @BUILD-DATESPdate SPtimeCR LF
date – Format: YYYY/MM/DD where YYYY = Year, MM = Month, DD = Day
hh:mm:ss
K-Config Example
“#BUILD-DATE?”,0x0D

11.3 Kramer Protocol 3000 – Detailed Commands

This section lists the detailed commands applicable to the FC-6.

11.3.1 #

Functions Permission Transparency
Set:
Get: - - -
Set: Protocol handshaking
Get: - -
Parameters
Notes
Validates the Protocol 3000 connection and gets the machine number Step-in master products use this command to identify the availability of a device
End User Public

11.3.2 BUILD-DATE?

Get:
Set: - -
Get: Get device build date
Parameters
time – Format:
Response Triggers
Notes
FC-6 – Kramer Protocol 3000 39
where hh = hours, mm = minutes, ss = seconds
End User Public
Functions
Permission
Transparency
Get:
COM-ROUTE?
End User
Internal
Get tunneling port routing
~nn @COM-ROUTE
Parameters
COM_Num – machine dependent, * (get all route tunnels)
TCP client ("/0")
Notes
This command sets tunneling port routing. Every com port can send or receive data from the ETH port. All com ports can be configured to the same ETH port.
Set COM1 as RS-232, port 1, Eth port 1, send replies, keep alive 30 seconds “#COM-ROUTE 1,1,1,1,30”,0x0D

11.3.3 COM-ROUTE

Set:
Description Syntax
Set tunneling
Set:
port routing
Get:
Response
portType – 1 (UDP), 2 (TCP) ETHPort - TCP/UDP port number ETH_rep_en - 0 (COM port does not send replies to new clients), 1 (COM port sends replies to new
clients) TCP_keep_alive_timing - 0-3600 seconds - every x seconds the device sends an empty string to
Response Triggers
K-Config Example
#COM-ROUTE
COM_Num,portType,ETHPort,ETH_rep_en,TCP_keep_alive_timing␍
#COM-ROUTE?COM_Num
COM_Num,portType,ETHPort,ETH_rep_en,TCP_keep_alive_timing␍␊
40 FC-6 - Kramer Protocol 3000
Functions
Permission
Transparency
COM-ROUTE-ADD
Get: - -
-
C
COM-ROUTE-ADD
COMNum - machine dependent
Timeout - Keep alive timeout in seconds (1 to 3600)
Notes
Add COM1 port as TCP, port 1, Eth port 1, send replies, keep alive 30 seconds “#COM-ROUTE-ADD 1,1,1,1,30”,0x0D

11.3.4 COM-ROUTE-ADD

Set:
Description Syntax
Set:
Get: - -
Response
~nn @
Parameters
portType - 1 (UDP), 2 (TCP) ETHPort - TCP/UDP port number ETHRepEn - 0 (COM port does not send replies to new clients), 1 (COM port sends replies to new clients)
Response Triggers
K-Config Example
Add a communication route tunnel connection
ComNum,PortType,EthPort,EthRepEn,Timeout␍␊
Administrator Internal
#COM-ROUTE-ADD
omNum,PortType,EthPort,EthRepEn,Timeout␍
FC-6 – Kramer Protocol 3000 41
Functions
Permission
Transparency
COM-ROUTE-REMOVE
Get: - -
-
Remove a communication route tunnel connection
Response
~nn @COM-ROUTE-REMOVE
ComNum – machine dependent
Notes
Remove comm port 1.
“#COM-ROUTE-REMOVE 1”,0x0D
DEL
Get: - -
-
#DELSP file_nameCR
Get:
~nn @DELSPfile_name CR
Parameters
“DEL test”,0x0D

11.3.5 COM-ROUTE-REMOVE

Set:
Description Syntax
Set:
Get: - -
ComNum␍␊
Parameters
Response Triggers
K-Config Example
Administrator Internal
#COM-ROUTE-REMOVE␠ComNum␍

11.3.6 DEL

Functions Permission Transparency
Set:
Description Syntax
Set: Delete file
Response
Administrator Public
file_name - name of file to delete (file names are case-sensitive)
Response Triggers
K-Config Example
Delete a file named “test”.
42 FC-6 - Kramer Protocol 3000
Functions
Permission
Transparency
DIR
Get: - -
-
#DIRCR
Get: - -
TAB
SPbytes. CR LF
“DIR”,0x0D
Functions
Permission
Transparency
ETH-PORT
Get:
ETH-PORT?
End User
Public
#ETH-PORTSP portType,ETHPortCR
#ETH-PORT?SP portTypeCR
Response
~nn @ETH-PORTSPportType, ETHPort CR LF
portType - 1 (UDP), 2 (TCP)
“ETH-PORT 2,1”,0x0D

11.3.7 DIR

Set:
Description Syntax
Set: List files in device
Response
Multi-line:
~nn @DIRCR LF
file_nameTAB file_sizeSPbytes, SPID:SP file_idCR LF
free_size
Parameters
file_name - name of file file_size - file size in bytes. A file can take more space on device memory file_id - internal ID for file in file system free_size - free space in bytes in device file system
Response Triggers
K-Config Example
Administrator Public

11.3.8 ETH-PORT

Set:
Description Syntax
Set: Set Ethernet port protocol
Get: Get Ethernet port protocol
Administrator Public
Parameters
ETHPort - TCP/UDP port number
Response Triggers
K-Config Example
Set ETH port 1 to UDP.
FC-6 – Kramer Protocol 3000 43
Functions
Permission
Transparency
Set: - - - Get:
ETH-TUNNEL?
Administrator
Internal
Set:
Get:
#ETH-TUNNEL?
TunnelId – tunnel ID number: 1-64 (depends on number of tunnel connections), * (all tunnel
Wired – 0 (non-wired connection), 1 (wired connection)
The response displays each tunnel in a separate line.
“ETH-TUNNEL? 1”,0x0D

11.3.9 ETH-TUNNEL

Description Syntax
Get parameters for open tunnels
Response
~nn @ETH-TUNNEL
TunnelId,ComNum,PortType,EthPort,EthIp,RemotPort,EthRepEn,Wired␍␊
Parameters
connections)
ComNum – UART number portType - 1 (UDP), 2 (TCP) ETHPort – TCP/UDP port number EthIp – client IP address RemotPort – remote port number EthRepEn – 0 (COM port does not send replies to new clients), 1 (COM port sends replies to new
clients)
Response Triggers
Notes
K-Config Example
TunnelId␍
44 FC-6 - Kramer Protocol 3000
Functions
Permission
Transparency
FACTORY
Get: - -
-
#FACTORYCR
Get: - -
~nn @FACTORYSPOK CR LF
Notes
Your device may require powering off and powering on for the changes to take effect.
“#FACTORY”,0x0D
FORMAT
Get: - -
-
#FORMATCR
Get: - -
~nn @FORMATSPOK CR LF
“#FORMAT”,0x0D

11.3.10 FACTORY

Set:
Description Syntax
Set: Reset device to factory default configuration
Response
Parameters
Response Triggers
This command deletes all user data from the device. The deletion can take some time.
K-Config Example
End User Public

11.3.11 FORMAT

Functions Permission Transparency
Set:
Description Syntax
Set: Format file system
Response
Administrator Public
Parameters
Response Triggers
Notes
Response could take several seconds until formatting completes
K-Config Example
FC-6 – Kramer Protocol 3000 45
Functions
Permission
Transparency
-
Get:
FS-FREE?
Administrator
Public
Get:
Get file system free space
#FS-FREE?CR
~nn @FS_FREESPfree_size CR LF
free_size - free size in device file system in bytes
K-Config Example
“#FS-FREE?”,0x0D
Set: - -
-
GET
Description
Syntax
#GETSP file_nameCR
Response
~nn @GETSP
SPOK CR LF
file_name - name of file to get contents
Response Triggers
Get a file named “test”. “#GET test”,0x0D

11.3.12 FS-FREE

Set:
Description Syntax
Set: - -
Response
Parameters
Response Triggers
- -

11.3.13 GET

Functions Permission Transparency
Get:
Set: - -
Get: Get file
Multi-line:
~nn @GETSPfile_name,file_size SPREADYCR LF
contents
file_name
Parameters
Administrator Public
contents - byte stream of file contents file_size - size of file (device sends it in response to give user a chance to get ready)
K-Config Example
46 FC-6 - Kramer Protocol 3000
Functions
Permission
Transparency
-
Get:
HELP
End User
Public
1. #HELPCR
#HELPSP
~nn @HELPSP
:CR LF
CR LFUSAGE:
CR LF
To get help for a specific command use: HELPSPCOMMAND_NAME CR LF
“#HELP”,0x0D

11.3.14 HELP

Set:
Description Syntax
Set: - -
Get:
Response
1. Multi-line: ~ nn@Device available protocol 3000 commands:CR LFcommand, SP command...CR LF
2. Multi-line:
Parameters
COMMAND_NAME – name of a specific command
Response Triggers
Notes
K-Config Example
Get command list or help for specific command
command
- -
2.
description
COMMAND_NAMECR
usage
FC-6 – Kramer Protocol 3000 47
Functions
Permission
Transparency
LOGIN
Get:
LOGIN?
Not Secure
Public
#LOGINSP login_level,passwordCR
#LOGIN?CR
Response
~nn @LOGIN SP
CR LF
Parameters
PASS
Response Triggers
enable the permission system in order to use the device
Set the protocol permission level to Admin (when the password defined in the PASS command is 33333):
“#LOGIN Admin,33333”,0x0D

11.3.15 LOGIN

Set:
Description S ynta x
Set: Set protocol permission
Get: Get current protocol permission level
Set: ~nn @LOGINSPlogin_level,password SP OKCR LF
or ~nn @LOGIN SPERR SP 004CR LF (if bad password entered)
Get:
login_level – level of permissions required: User, Admin password – predefined password (by
Notes
When the permission system is enabled, LOGIN enables running commands with the User or Administrator permission level When set, login must be performed upon each connection The permission system works only if security is enabled with the SECUR command. It is not mandatory to
K-Config Example
login_level
command). Default password is an empty string
Not Secure Public
48 FC-6 - Kramer Protocol 3000
Functions
Permission
Transparency
LOGOUT
Get: - -
-
#LOGOUTCR
Get: - -
~nn @LOGOUTSPOK CR LF
Notes
“#LOGOUT”,0x0D
Set:
MACH-NUM
End User
Public
Set:
Set machine number (device ID)
#MACH-NUMSP machine_number CR
~nn @MACH-NUMSPmachine_number CR LF
Parameters
The new machine number is only set after restarting the device.
K-Config Example
“#MACH-NUM 4”,0x0D

11.3.16 LOGOUT

Set:
Description Syntax
Set: Cancel current permission level
Response
Parameters
Response Triggers
Logs out from User or Administrator permission levels
K-Config Example
Not Secure Public

11.3.17 MACH-NUM

Functions Permission Transparency
Get:
Description Syntax
Get: - -
Response
- -
machine_number – New machine number
Response Triggers
Notes
FC-6 – Kramer Protocol 3000 49
Functions
Permission
Transparency
-
Get:
MODEL?
End User
Public
Get:
Get device model
#MODEL?CR
~nn @MODELSPmodel_name CR LF
model_name – String of up to 19 printable ASCII chars
Notes
to the connected equipment. The Matrix saves this data in memory to answer RE MOTE-INFO requests
“#MODEL?”,0x0D

11.3.18 MODEL

Set:
Description Syntax
Set: - -
Response
Parameters
Response Triggers
This command identifies equipment connected to Step-in master products and notifies of identity changes
K-Config Example
- -
50 FC-6 - Kramer Protocol 3000
Functions
Permission
Transparency
NAME
Get:
NAME?
End User
Public
#NAMESP machine_nameCR
#NAME?CR
Response
~nn @NAME? SP
CR LF
Parameters
The machine name is not the same as the model name. The machine name is used to identify a specific machine or a network in use (with DNS feature on)
“#NAME FC-6-4321”,0x0D
Set:
NAME-RST
Administrator
Public
Get: - -
-
Reset machine (DNS) name to Get: - -
~nn @NAME-RSTSPOK CR LF
Parameters
K-Config Example
“#NAME-RST”,0x0D

11.3.19 NAME

Set:
Description Syntax
Set: Set machine (DNS) name
Get: Get machine (DNS) name
Set: ~nn @NAMESPmachine_name CR LF
Get:
machine_name - string of up to 15 alpha-numeric chars (can include hyphen, not at the beginning or end)
Response Triggers
Notes
K-Config Example
Set machine name to FC-6-4321:
machine_name
Administrator Public

11.3.20 NAME-RST

Functions Permission Transparency
Description Syntax
Set:
factory default
#NAME-RSTCR
Response
Response Triggers
Notes
Factory default of machine (DNS) name is “KRAMER_” + 4 last digits of device serial number
FC-6 – Kramer Protocol 3000 51
Functions
Permission
Transparency
NET-DHCP
Get:
NET-DHCP?
End User
Public
#NET-DHCPSP modeCR
#NET-DHCP?CR
Response
~nn @NET-DHCPSP
CR LF
mode – 0 (do not use DHCP. Use the IP address set by the factory or the NET-IP command), 1 (try to use
NET-IP
Consult your network administrator for correct settings
K-Config Example
“#NET-DHCP 1”,0x0D
Set:
NET-GATE
Administrator
Public
NET-GATE?
Set:
Set gateway IP
#NET-GATESP
CR
#NET-GATE?CR
~nn @NET-GATESPip_address CR LF
Parameters
xxx.xxx.xxx.xxx
A network gateway connects the device via another network, possibly over the Internet. Be careful of security problems. Consult your network administrator for correct settings.
“#NET-GATE 192.168.000.001”,0x0D

11.3.21 NET-DHCP

Set:
Description Syntax
Set: Set DHCP mode
Get: Get DHCP mode
mode
Parameters
DHCP. If unavailable, use the IP address set by the factory or the
Response Triggers
Notes
Connecting Ethernet to devices with DHCP may take more time in some networks To connect with a randomly assigned IP by DHCP, specify the device DNS name (if available) using the NAME command. You can also get an assigned IP by direct connection to USB or RS-232 protocol port if available
Enable DHCP mode, if available:
Administrator Public
command)

11.3.22 NET-GATE

Functions Permission Transparency
Get:
Description Syntax
Get: Get gateway IP
Response
End User Public
ip_address
ip_address – gateway IP address, in the following format:
Response Triggers
Notes
K-Config Example
Set the gateway IP address to 192.168.0.1:
52 FC-6 - Kramer Protocol 3000
Functions
Permission
Transparency
NET-IP
Get:
NET-IP?
End User
Public
#NET-IPSP ip_addressCR
#NET-IP?CR
Response
~nn @NET-IPSP
CR LF
ip_address – IP address, in the following format: xxx.xxx.xxx.xxx
Set the IP address to 192.168.1.39:
“#NET-IP 192.168.001.039”,0x0D
-
Get:
NET-MAC?
End User
Public
Get:
Get MAC address
#NET-MAC?CR
~nn @NET-MACSPmac_address CR LF
XX-XX-XX-XX-XX-XX
Notes
“#NET-MAC?”,0x0D

11.3.23 NET-IP

Set:
Description Syntax
Set: Set IP address
Get: Get IP address
ip_address
Parameters
Response Triggers
Notes
Consult your network administrator for correct settings
K-Config Example
Administrator Public

11.3.24 NET-MAC

Functions Permission Transparency
Set:
Description Syntax
Set: - -
Response
- -
Parameters
mac_address – unique MAC address. Format:
Response Triggers
K-Config Example
FC-6 – Kramer Protocol 3000 53
where X is hex digit
Functions
Permission
Transparency
NET-MASK
Get:
NET-MASK?
End User
Public
#NET-MASKSP net_maskCR
#NET-MASK?CR
Response
~nn @NET-MASKSP
CR LF
net_mask - format: xxx.xxx.xxx.xxx
Consult your network administrator for correct settings
“#NET-MASK 255.255.000.000”,0x0D
Set:
PASS
Administrator
Public
PASS?
Description
Syntax
Set:
Set password for login level
#PASSSP login_level,passwordCR
#PASS?SP login_levelCR
~nn @PASSSP
CR LF
login_level – level of login to set: User, Admin
“#PASS Admin,33333”,0x0D

11.3.25 NET-MASK

Set:
Description Syntax
Set: Set subnet mask
Get: Get subnet mask
net_mask
Parameters
Response Triggers
The subnet mask limits the Ethernet connection within the local network
Notes
K-Config Example
Set the subnet mask to 255.255.0.0:
Administrator Public

11.3.26 PASS

Functions Permission Transparency
Get:
Get: Get password for login level
Response
login_level,password
Parameters
Administrator Public
password – password for the login_level. Up to 15 printable ASCII chars.
Response Triggers
Notes
The default password is an empty string
K-Config Example
Set the password for the Admin protocol permission level to 33333:
54 FC-6 - Kramer Protocol 3000
Functions
Permission
Transparency
PORT-LOCK
Get:
PORT-LOCK?
End User
Public
#PORT-LOCK
Get the port lock state
#PORT-LOCK?
@PORT-LOCK
Parameters
PortNumber - port number (1-n) LockState - lock (1), unlock (0)
Lock port 3.
“#PORT-LOCK 3, 1”,0x0D
PORT-TYPE
Get:
PORT-TYPE?
End User
Public
#PORT-TYPE?
@PORT-TYPE
PortNumber - Port number: 1-n
485Term - 485 termination state: 1 (enable), 0 (disable)
Change port 3 to relay and name it blinds:
“#PORT-TYPE 3,3,blinds”,0x0D

11.3.27 PORT-LOCK

Set:
Description Syntax
Set: Set the port lock
Get:
Response
~nn
Response Triggers
Notes
K-Config Example
PortNumber,LockState␍␊
End User Public
PortNumber,LockState␍
PortNumber␍

11.3.28 PORT-TYPE

Functions Permission Transparency
Set:
Description Syntax
Set: Change the port type
Get: Get the port type
Response
~nn
Parameters
PortNumber,PortType,PortName,485Term␍␊
End User Public
#PORT-TYPE␠PortNumber,PortType,PortName,
485Term␍
PortNumber␍
PortType - 0 (RS-232), 4 (IR) PortName - A string describing the port type
Response Triggers
Notes
485Term is effective only when the port type is UART
K-Config Example
FC-6 – Kramer Protocol 3000 55
Functions
Permission
Transparency
-
Get:
PROT-VER?
End User
Public
Get:
Get device protocol version
#PROT-VER?CR
~nn @PROT-VERSP3000:version CR LF
version - XX.XX where X is a decimal digit
Notes
“#PROT-VER?”,0x0D
Set:
RESET
Administrator
Public
-
Set:
Reset device
#RESETCR
~nn @RESETSPOK CR LF
Parameters
To avoid locking the port due to a USB bug in Windows, disconnect USB connections immediately after running this command. If the port was locked, disconnect and reconnect the cable to reopen the port.
“#RESET”,0x0D

11.3.29 PROT-VER

Set:
Description Syntax
Set: - -
Response
Parameters
Response Triggers
K-Config Example
- -

11.3.30 RESET

Functions Permission Transparency
Get:
Description Syn tax
Get: - -
Response
- -
Response Triggers
Notes
K-Config Example
56 FC-6 - Kramer Protocol 3000
Functions
Permission
Transparency
SECUR
Get:
SECUR?
Not Secure
Public
#SECURSP security_modeCR
#SECUR?CR
Response
~nn @SECURSP
CR LF
security_mode – 1 (On / enable security), 0 (Off / disable security)
SECUR
Enable the permission system.
“#SECUR 0”,0x0D
Get:
SN?
End User
Public
Get:
Get device serial number
#SN?CR
~nn @SNSPserial_number CR LF
Notes
“#SN?”,0x0D

11.3.31 SECUR

Set:
Description Syn tax
Set: Start/stop security
Get: Get current security state
security_mode
Parameters
Response Triggers
Notes
The permission system works only if security is enabled with the
K-Config Example
Administrator Public
command

11.3.32 SN

Functions Permission Transparency
Set: - - -
Description Syntax
Set: - -
Response
Parameters
serial_number – 11 decimal digits, factory assigned
Response Triggers
This device has a 14 digit serial number, only the last 11 digits are displayed
K-Config Example
FC-6 – Kramer Protocol 3000 57
Functions
Permission
Transparency
TIME
Get:
TIME?
End User
Public
#TIMESP day_of_week,date,timeCR
Get:
Get device time and date
#TIME?CR
~nn @TIMESPday_of_week,date,time CR LF
day_of_week - one of: SUN, MON, TUE, WED, THU, FRI, SAT
hh:mm:ss
Response Triggers
K-Config Example
“#TIME TUE,01-07-2015,09:45:00”,0x0D

11.3.33 TIME

Set:
Description Syntax
Set: Set device time and date
Response
Parameters
date - format: DD-MM-YYYY time - format:
Notes
The year must be 4 digits The device does not validate the day of week from the date Time format - 24 hours Date format - Day, Month, Year
Set the time to 09:45, Tuesday, 01-July-2015.
Administrator Public
58 FC-6 - Kramer Protocol 3000
Functions
Permission
Transparency
TIME-LOC
Get:
TIME-LOC?
End User
Public
#TIME-LOCSP UTC_off,DayLightCR
#TIME-LOC?CR
Response
~nn @TIME-LOCSP
CR LF
UTC_off - offset of device time from UTC/GMT (without daylight time correction)
If the time server is configured, device time calculates by adding UTC_off to UTC time (that it got from the
TIME command sets the device time without considering these settings
K-Config Example
“#TIME-LOC 2,0”,0x0D

11.3.34 TIME-LOC

Set:
Description Syn tax
Set: Set local time offset from UTC/GMT
Get: Get local time offset from UTC/GMT
UTC_off,DayLight
Parameters
DayLight - 0 - no daylight saving time, 1 - daylight saving time
Response Triggers
Notes
time server) + 1 hour if daylight savings time is in effect
Set the time offset to GMT +2, standard time
End User Public
FC-6 – Kramer Protocol 3000 59
Functions
Permission
Transparency
TIME-SRV
Get:
TIME-SRV?
End User
Public
#TIME-SRVSP
CR
#TIME-SRV?CR
~nn @TIME-SRVSP
CR LF
mode - 0 (OFF), 1 (ON)
- ON/OFF
Connect the device to a time server at a given IP address, activate and sync at 6AM
“#TIME-SRV 1,xxx.xxx.xxx.xxx,06”,0x0D

11.3.35 TIME-SRV

Set:
Description Syntax
Set: Set time server
Get: Get time server
Response
mode, time_server_IP, time_server_Sync_Hour,server_status
Parameters
time_server_IP - time server IP address time_server_Sync_Hour - hour in day for time server sync
server_status
Response Triggers
Notes
This command is needed for setting UDP timeout for the current client list
K-Config Example
Administrator Public
mode,time_server_IP,time_server_Sync_Hour,
60 FC-6 - Kramer Protocol 3000
Functions
Permission
Transparency
UART
Get:
UART?
End User
Public
#UARTSP
CR
Get:
Get com port configuration
#UART?SP COM_NumCR
UARTSP COM_Num,baud_rate,data_bit,parity,stop_bit CR LF
LF
COM_Num - 1-2
Response Triggers
“#UART 1,9600,8,N,1,0”0x0D

11.3.36 UART

Set:
Description Synta x
Set: Set com port configurati on
Response
Set: ~nn @
Get:
~nn @
UARTSP COM_Num,baud_rate,data_bit,parity,stop_bit,serial1_type,485_term CR
Parameters
baud_rate - 9600 - 115200 data_bit - 7-8 parity - N (none), O (odd), E (even), M (mark), S (space) stop_bit - 1-2 serial1_type - 0 (RS-232) 485_term - 1/0 (optional - this exists exist only when serial1_type = 485)
Notes
K-Config Example
Configure RS-232 com port 1 to 9600 baud, 8 data bits, no parity, 1 stop bit
Administrator Public
COM_Num,baud_rate,data_bit,parity,stop_bit
FC-6 – Kramer Protocol 3000 61
Functions
Permission
Transparency
Get:
VERSION?
End User
Public
Get:
Get firmware version number
#VERSION?CR
~nn @VERSIONSPfirmware_version CR LF
firmware_version – XX.XX.XXXX where the digit groups are: major.minor.build version
Notes
“#VERSION?”,0x0D

11.3.37 VERSION

Set: - - -
Description Syntax
Set: - -
Response
Parameters
Response Triggers
K-Config Example
62 FC-6 - Kramer Protocol 3000
P/N:
2900-300585
Rev:
3
SAFETY WARNING
Disconnect the unit from the power supply before opening and servicing
For the latest information on our products and a list of Kramer distributors, visit our Web site to find updates to this user manual.
We welcome your questions, comments, and feedback.
www.kramerAV.com
info@kramerAV.com