Kramer F-110 User Manual

Kramer Electronics, Ltd.
USER MANUAL
Model:
F-110
Contents
i
Contents
1 Introduction 1 2 Getting Started 1 3 Overview 2
3.1 About the Power Connect Feature 2
3.2 Shielded Twisted Pair (STP) / Unshielded Twisted Pair (UTP) 2
3.3 Achieving the Best Performance 3
4 Your F-110 XGA Line Transmitter 4 5 Connecting the F-110 5
5.1 Wiring the 9-pin Terminal Block Line Output Connector 7
5.2 Wiring the CAT 5 LINE IN / LINE OUT RJ-45 Connectors 8
6 Using the F-110 8 7 Technical Specifications 10
Figures
Figure 1: F-110 XGA Line Transmitter 4 Figure 2: Connecting the F-110 to the TP-120 6 Figure 3: Terminal Block Pinouts 7 Figure 4: CAT 5 PINOUT 8
Tables
Table 1: F-110 Features 4 Table 2: CAT 5 PINOUT 8 Table 3: F-110 Applications 8 Table 4: Technical Specifications of the F-110 10
Introduction
1
1 Introduction
Welcome to Kramer Electronics! Since 1981, Kramer Electronics has been providing a world of unique, creative, and affordable solutions to the vast range of problems that confront the video, audio, presentation, and broadcasting professional on a daily basis. In recent years, we have redesigned and upgraded most of our line, making the best even better! Our 1,000-plus different models now appear in 11 groups
1
that are clearly
defined by function. Thank you for purchasing the Kramer F-110 XGA Line Transmitter on
dual-slot wall-plate insert which is ideal for:
Presentation venues
Multimedia applications
Long range graphics distribution for schools, hospitals, security, and
stores
The F-110 can be mounted on Kramer
2
:
Wall-plate insert mounting frames for Ackermann floor boxes
TBUS table connection buses connecting surfaces
Wall plate insert frames
The package includes the following items:
F-110
Power adapter (12V DC Input) and this user manual
3
2 Getting Started
We recommend that you:
Unpack the equipment carefully and save the original box and
packaging materials for possible future shipment
Review the contents of this user manual
Use Kramer hi gh-performance high-resolution cables
4
1 GROUP 1: Distribution Amplifiers; GROUP 2: Switchers and Matrix Switchers; GROUP 3: Control Systems; GROUP 4: Format/Standards Converters; GROUP 5: Range Extenders and Repeaters; G ROUP 6: Specialty AV Products; GROUP 7: Scan Converters and Scalers; GROUP 8: Cables and Connectors; GROUP 9: Room Connectivity; GROUP 10: Accessories and Rack Adapters; GROUP 11: Sierra Products 2 The complete list of Kramer products can be found on our Web site at http://www.kramerelectronics.com 3 Download up-to-date Kramer user manuals from the Internet at http://www.kramerelectronics.com 4 The complete list of Kramer cables is on our Web site at http://www.kramerelectronics.com
KRAMER: SIMPLE CREATIVE TECHNOLOGY
Overview
2
3 Overview
The Kramer F-110 dual-slot wall-plate insert is an XGA line transmitter that accepts up to a UXGA video signal, encodes it to a twisted pair (TP) signal, and transmits the TP signal to a compatible TP receiver
1
.
In particular, the F-110:
Has a resolution of up to UXGA
Includes the Kramer Power Connect™ feature
Has a 12V DC power supply
Fits into various insert mounting surfaces
2
3.1 About the Power Connect Feature
The
Power Connect feature applies as long as the cable can carry power. This feature is available when using STP cable and the distance does not exceed 50m on standard CAT 5 cable. For longer distances, heavy gauge cable should be used
3
. For units which are connected via RJ-45 connectors, make sure that the shield of the STP cable is connected to the metal casing of the connectors on both ends of the cable. For units which are connected via terminal block connectors, the shield of the STP cable must be connected to a ground terminal on the units at both ends (use the ground terminal of the power supply connection if necessary).
For a CAT 5 cable exceeding a distance of 50m, separate power supplies should be connected to the transmitter and to the receiver simultaneously.
3.2 Shielded Twisted Pair (STP) / Unshielded Twisted Pair (UTP)
We
recommend that you use Shielded Twisted Pair (STP) cable. There are different levels of STP cable available, and we advise you to use the best quality STP cable that you can afford. Our non-skew-free cable, Kramer BC-STP is intended for analog signals where skewing is not an issue. For cases where there is skewing, our UTP skew-free cable, Kramer BC-XTP, may be used. Bear in mind, though, that we advise using STP cables where possible, since the compliance to electromagnetic interference was tested using those cables.
Although Unshielded Twisted Pair (UTP) cable might be preferred for long range applications, the UTP cable should be installed far away from electric
1 For example, the Kramer TP-120 or PT-120 2 For example, TBUS units, wall plate frames or Ackermann insert mounting frames (see section 6
)
3 CAT 5 cable is still suitable for the video/audio transmission, but not for feeding the power at these distances
Overview
3
cables, motors and so on, which are prone to create electrical interference . However, since the use of UTP cable m ight cause inconformity to electromagnetic standards, Kramer does not commit to meeting the standard with UTP cable.
3.3 Achieving the Best Perfo rmance
To ac
hieve the best performance:
Use only good quality connection cables
1
to avoid interference, deterioration in signal quality due to poor matching, and elevated noise levels (often associated with low-quality cables).
Avoid interference from neighboring electrical appliances that may
adversely influence signal quality and position your Kramer F-110 away from moisture, excessive sunlight and dust
1 Available from Kramer Electronics on our Web site at http://www.kramerelectronics.com
KRAMER: SIMPLE CREATIVE TECHNOLOGY
Your F-110 XGA Line Transmitter
4
4 Your F-110 XGA Line Transmitter
Figure 1 and Table 1 define the F-110:
Figure 1: F-110 XGA Line Transmitter
Table 1: F-110 Features
# Feature Function
1 Screw holes (4) Fix the wall plate to the connecting surface
2
PC INPUT 15-pin HD F Connector Connect to the XGA source
3 ON LED Lights green when rece iving pow er 4 12V DC + PIN1 Connect (+) to the connector for powering the unit 5 - PIN Connect (-) to the Ground 6 + PIN1 Connect (+) to the connector for powering the unit 7 - PIN Connect (-) to the Ground 8 Line output 8-pin terminal block
Connector
2
Connects to the LINE IN RJ-45 connector on t h e K r a m er PT-120 or TP-120 XGA Line Receiver
1 One set is used to power the F-110 and the other set can be used to power an adjacent insert 2 See section 5.1
Connecting the F-110
5
5 Connecting the F-110
The Kramer F-110 together with the Kramer PT-120 or TP-120 XGA line receivers constitute a VGA/XGA-to-twisted pair transmitter and receiver.
To connect the F-110, do the following:
1. Unscrew the two screws that fasten each of the two adjacent blank plates to the connecting surface and remove them.
2. Place and align the F-110 dual-slot wall-plate insert over the openi ng.
3. Connect the cables to the rear side of the insert, that is, attach the: Terminal block line output of the F-110 to the pre-installed UTP
wiring that connects to the TP receiver (with a range of more than 300ft (>100m)), see section 5.1
12V DC power supply to either one of the power terminal blocks
(connect the wire labeled “+” to the +12V pin, and the wire labeled “–” to the GND pin) taking care that the polarity is correct. You can use the second power terminal block to power an additional unit (for example, an adjacent insert on the mounting surface)
4. Insert the four screws to fix the insert in place, and tighten them.
5. Connect the UXGA source to the PC IN connector (for example, a computer graphics source).
KRAMER: SIMPLE CREATIVE TECHNOLOGY
Connecting the F-110
6
Figure 2: Connecting the F-110 to the TP-120
Connecting the F-110
7
5.1 Wiring the 9-pin Terminal Block Line Outpu t Connector
The 8-pin terminal block is an easy plug-in connector for attaching the UTP cable. Follow the colors of the color-coded sticker on these terminals for proper connection of the UTP cable. Figure 3
defines the pinouts for the
terminal block.
Figure 3: Terminal Block Pinouts
Notes:
Use the connector clips only when removing wires, not when inserting
them
Each wire should protrude 9mm (0.35") from the plastic insulation so
that it can be easily connected. To prevent the wires crossing, be sure that each wire is fully inserted
Orange / Whit e
Green / White
Brown / White
Brown
Green
Blue / White
Blue
Orange
KRAMER: SIMPLE CREATIVE TECHNOLOGY
Using the F-110
8
5.2 Wiring the CAT 5 LINE IN / LINE OUT RJ-45 Connectors
Table 2
and Figure 4 define the UTP CAT 5 PINOUT, on the RJ-45
connector:
Table 2: CAT 5 PINOUT
Figure 4: CAT 5 PINOUT
EIA /TIA 56 8A EIA /TIA 56 8B
PIN Wire Color PIN Wire Color
1 Green / White 1 Orange / White 2 Green 2 Orange 3 Orange / White 3 Green / White 4 Blue 4 Blue 5 Blue / White 5 Blue / White 6 Orange 6 Green 7 Brown / White 7 Brown / White 8 Brown 8 Brown
Pair 1 4 and 5 Pair 1 4 and 5 Pair 2 3 and 6 Pair 2 1 and 2 Pair 3 1 and 2 Pair 3 3 and 6 Pair 4 7 and 8 Pair 4 7 and 8
6 Using the F-110
Table 3 shows examples of how the F-110 dual-slot wall-plate insert can be
installed in various applications.
Table 3: F-110 Applications
F-110 installed in a wall plate insert frame (for ex ample, the Kramer FRAME 1G/US):
Using the F-110
9
F-110 installed in an Ackermann floor box frame (for example, the Kramer FLA-12):
F-110 installed in a TBUS connecting surface (for example, a Kramer TBUS):
KRAMER: SIMPLE CREATIVE TECHNOLOGY
Technical Specifications
10
7 Technical Specifications
Table 4 lists the technical specifications:
Table 4: Technical Specifications1 of the F-110
INPUT: 1 VGA / UXGA on a 15-pin HD connector OUTPUT: 1 CAT 5 LINE OUTPUT on an 8-pin terminal block connector RESOLUTION: Up to UXGA MAX. OUTPUT LEVEL: 2Vpp DIFF. GAIN2: 6.3% (worst case) DIFF. PHASE2 0.3 Deg (worst case) K-FACTOR2: <0.05% S/N RATIO2: 69.5dB , 5MHz CONTROLS: ON power LED COUPLING: DC POWER SOURCE: 12V DC 250mA, feeding receiver DIMENSIONS: 5cm x 2.4cm x 4.7cm (1.97" x 0.94 " 1.85") W, D, H WEIGHT: 0.14kg (0.31lbs) approx. ACCESSORIES: Power supply
1 Specifications are subject to change without notice 2 For the transmitter/receiver pair
11
LIMITED WARRANTY
WHO IS PROTECTED?
WHA T IS COVERED AND WHAT IS NOT COVERED
WHAT WE WILL PAY FOR AND WHAT WE WILL NOT PAY FOR
HOW YOU CAN GET WARRANTY SERVICE
LIMIT A TION O F IMPLIED W ARRAN TIES
EXCLUSION OF DAMAGES
CAUTION!
W e warrant this product free from defects in material and workmanship under the following terms.
HOW LONG IS THE W ARRANTY
Labor and parts are warranted for seven years from the date of the first customer purchase.
Only the first purchase customer may enforce th is warranty.
W e will p ay labor and ma terial ex pense s for cov ered i tems. W e will not pay for the fol lowing:
The liability of Kramer for any effective products is limited to the repair or replacement of the product at our option. Kramer shall not be liable fo r:
This warranty gives you specific legal rights, and you may also have other rights, which vary from place to place.
All products returned to Kramer for service must have prior approval. This may be obtained from your dealer.
This equipment has been tested to determine compliance with the requirements of:
EN-50081: "Electromagnetic compatibility (EMC);
generic emission standard. Residential, commercial and light industry" EN-50082: "Electromagnetic compatibility (EMC) generic immunity standard.
Part 1: Residential, commercial and light industry environment". CFR-47: FCC* Rules and Regulations:
Part 15: “Radio frequency devices
Subpart B Unintentional radiators”
Except as below, this warranty covers all defects in material or workmanship in this product. The following are not covered by the warranty:
1. Any product which is not distributed by us or which is not purchased from an authorized Kramer dealer. If you are uncertain as
to whether a dealer is authorized, please contact Kramer at one of the agents listed in the Web site www.kramerelectronics.com.
2. Any product, on which the serial number has been defaced, modified or removed, or on which the WARRANTY VOID
TAMPERED stic ke r ha s be en torn,
3. Damag e, deter ioration o r malfun ction re sulting fr om:
i) Accident, misuse, abuse, neglect, fire, water, lightning or other acts of nature ii) Produc t modifi cation , or failu re to fo llow ins truction s supp lied wit h the pro duct iii) Repair o r attemp ted re pair by an yone no t auth orized by Kramer iv) Any shipme nt of the pr oduct ( claims m ust be presente d to the c arrie r) v) Remova l or inst allati on of th e produ ct vi) Any other caus e, whic h does n ot rela te to a pro duct d efect vii) Cartons, equipment enclosures, cables or accessories used in conjunction with the product
1. Remo val or in stallatio ns char ges.
2. Costs of initial t echnical ad justments (set -up), i ncluding adjustment of user controls or programming . These co sts are th e
respon sibili ty of the Kramer dealer from whom the pro duct w as purc hased.
3. Shipping char ges.
1. To obtain service on you product, you must take or ship it prepaid to any authorized Kramer service center.
2. Whenever warranty service is required, the orig inal dated invoice (or a copy) must be presented as proof of warranty
coverage, and should be included in any shipment of the product. Please also include in any mailing a contact name, company, address, and a description of the problem(s).
3. For the name of the nearest Kramer authorized service center, consult your authorized dealer.
All implied warranties, including warranties of merchantability and fitness for a particular purpose, are limited i n duration to the length of this warranty.
1. Damage to other property caused by defects in this product, damages based upon inconvenience, loss of use of the product, loss
of time, commercial loss; or:
2. Any other d ama ges, w hethe r inci dent al, con seq uenti al or o the rwise. Som e count ries may not allow limit ations on how lon g an
implied warranty lasts and/or do not allow the exclusion or limitation of incidental or consequential damages, so the above limita tions and exclus ions ma y not app ly to yo u.
Servicing the machines can only be done by an authorized Kramer technician. Any user who makes changes or modifications to the unit without the express ed approval of the manufacturer will void user authority to operate the equipment.
Please use recommended interconnection cables to connect the machine to other components.
IF reattached, removed or otherwise interfered with.
* FCC and CE approved using STP cable (for twisted pair products)
NOTE:
Part 1:
Kramer Electronics, Ltd.
Web site: www.kramerelectronics.com
E-mail: info@kramerel.com
P/N: 2900-000718 REV 3
For the latest information on our products and a list of Kramer
distributors, visit our Web site: www.kramerelectronics.com
where updat
es to this user manual may be found.
We welcome your questions, comments and feedback.
Caution
Safety Warning:
Disconnect the unit from the power supply before opening/servicing.
Loading...