
675R/T Kit Quick Start Guide
This guide helps you install and use your 675R/T for the first time.
Go to www.kramerav.com/downloads/675R/T to download the latest user manual and check if firmware
upgrades are available.
Step 1: Check what’s in the box
675T HDMI Optical Transmitter
2 Power adapters and cords
675R HDMI Optical Receiver
2 OSP-MM1 Fiber Optic SFP+ Transceivers
Step 2: Get to know your 675R/T
675T
Lights green when a connected source device (with an active HDMI signal) is
detected.
Flashes 4 times green when resetting the device.
Off when a connected source device with an active signal is not detected.
Lights green when both a connected HDMI source (with an active HDMI signal) and
a connected far-end HDMI acceptor are detected.
Off if either the source or the acceptor is not connected, or an active signal is not
present.
Light green when OUT IN SFP+ is connected and an active optical link is detected.
Light red when OUT IN SFP+ is connected, but an active optical link is not detected.
Off when OUT IN SFP+ is disconnected.
Lights green when the device receives power.
Connect to an HDMI source.
Connect the fiber optic cable to the plugged-in SFP+ optical module connector.
Press and hold to reset settings to factory default values.
Connect to a PC to perform firmware upgrade (via K-Upload).
12V DC connector for powering the unit.

Lights green when a connected far-end source device (with an active HDMI signal)
is detected.
Off when a connected source device with an active signal is not detected.
Lights green when both a connected HDMI source (with an active HDMI signal) and
a connected HDMI acceptor are detected.
Off if either the source or the acceptor is not connected, or an active signal is not
present.
Light green when OUT IN SFP+ is connected, and an active optical link is detected.
Light red when OUT IN SFP+ is connected but an active optical link is not detected.
Off when OUT IN SFP+ is disconnected.
Lights green when the device receives power.
Connect to an HDMI acceptor.
OUT IN SFP+ Connector opening
Connect the fiber optic cable to the plugged-in SFP+ optical module connector.
Connect to a PC to perform firmware upgrade (via K-Upload).
12V DC connector for powering the unit.
Step 3: Install 675R/T
Install 675R/T using one of the following methods:
• Attach the rubber feet and place the unit on a flat surface.
• Fasten a bracket (included) on each side of the unit and attach it to a flat surface
(see www.kramerav.com/downloads/675R/T).
• Mount the unit in a rack using the recommended rack adapter
(see www.kramerav.com/downloads/675R/T).
• Ensure that the environment (e.g., maximum ambient temperature &
air flow) is compatible for the device.
• Avoid uneven mechanical loading.
• Appropriate consideration of equipment nameplate ratings should be
used for avoiding overloading of the circuits.
• Reliable earthing of rack-mounted equipment should be maintained.
• Maximum mounting height for the device is 2 meters.
Step 4: Connect the inputs and outputs
Always switch OFF the power on each device before connecting it to your 675R/T. For best results, we recommend that you
always use Kramer high-performance cables to connect AV equipment to 675R/T.
Make sure that you always cross-connect the fiber connections, Rx OUT to Tx IN and Rx IN to Tx OUT, as unidirectional optical
transmission is carried on simplex fiber strands.

To install/replace the OSP-MM1 or other Kramer recommended SFP+
transceiver:
1. Pull the bail out and remove the currently installed transceiver,
insert the protective cap and store in a safe place.
2. Make sure the bail of the new transceiver is pushed up, in the
closed position.
3. Insert the new transceiver into the relevant optical device SFP+ slot
and push it in until it clicks.
4. Remove the protective cap and store it in a safe place for future
use.
Warning: Connecting the SFP+ transceiver to an LC(APC) fiber
connector may cause poor performance and damage the connector!
Refer to www.kramerav.com/downloads/OSP-MM1 for more information.
Warning: Class 1 Laser Product
• Invisible laser radiation present.
• Avoid long-term viewing of laser.
• Avoid the use of magnifying viewing aids or instruments (such as binoculars, telescopes, microscopes and
magnifying lenses, but not spectacles or contact lenses).
• Avoid placing optical devices in the emitted beam that could cause the concentration of the laser radiation to be
increased.
Step 5: Connect the power
Connect the power cords to 675T and 675R and plug into the mains electricity.
Safety Instructions (See www.kramerav.com for updated safety information).
Caution:
• There are no operator serviceable parts inside the unit.
Warning:
• Use only the power cord that is supplied with the unit.
• Disconnect the power and unplug the unit from the wall before installing.

Technical Specifications
On a female HDMI connector
On a female micro USB connector
On a female HDMI connector
On a female micro USB connector
4096x2160@60Hz 4K@60 (4:4:4)
Multi-mode (MM) or single-mode (SM)
Kramer 10Gbps SFP+ IEEE 802.3ae compliant
modules (OSP-MM1 modules included)
Max Reach over OM3 MM Fiber
Max Reach over OS1 SM Fiber
IN, OUT, LINK and ON LED indicators; 675T:
RESET button
12V DC, 675T: 280mA; 675R: 220mA
0° to +40°C (32° to 104°F)
-40° to +70°C (-40° to 158°F)
10% to 90%, RHL non-condensing
2 OSP-MM1 fiber optic transceivers, 2 power
adapters, 2 power cords and 2 bracket sets
Specifications are subject to change without notice at www.kramerav.com
The terms HDMI, HDMI High-Definition Multimedia Interface, and the HDMI Logo are trademarks or registered trademarks of HDMI Licensing Administrator, Inc.