RPS GEAR DRIVEN SPRINKLER SETTING INSTRUCTIONS
CHANGING A NOZZLE
1
REMOVING THE NOZZLE RETENTION SCREW
Use the hex key end “A” of the universal tool to remove
the nozzle retention screw by turning counter-clockwise
to remove and clockwise to re-install.
2
PULL UP THE RISER
Insert the “B” end of the universal tool in the keyhole on the
top of the nozzle turret and turn the key 1/4 turn to insure
that the key does not slip out of the keyhole when you pull
it up.Firmly pull up the entire spring-loaded riser to access
the nozzle socket.Hold the riser assembly with one hand.
3
REMOVING THE NOZZLE
With the nozzle retention screw removed, the nozzle may
be removed by either turning on the water (wear safety
glasses when using this method), or by pulling outward
on the nozzle prongs with a pair of needle-nose pliers.
4
INSTALLING A NOZZLE
Press the desired nozzle into the nozzle socket.Make
sure the nozzle number is visible and the nozzle “prongs”
are up.Then, re-install the nozzle retention screw.
NOTE: The nozzle retention screw is also a break-up
screw and used to adjust the distance of the spray.
SETTING THE ARC ADJUSTMENT
NOTE: The RPS gear dr iven sprinkler has a fixed right start
and an adjustable left stop.
1
POSITIONING NOZZLE TURRET TO ITS “RIGHT START”
Place your finger on the top center of the nozzle turret.
Rotate the turret counter-clockwise to the left stop to
complete any interrupted rotation cycle. Rotate the nozzle
turret clockwise to the “right start.” This is the fixed side of
the arc.The nozzle turret must be held in this position for
arc adjustments.The “right start” does not change.
NOTE: The RPS is factory preset with a 180° arc setting, and includes a pre-installed #3 nozzle.
KEY IN KEYHOLE
NOZZLE
TURRET
NOZZLE
RETENTION
SCREW
NOZZLE
SOCKET
NOZZLE
RETENTION
SCREW
KEYHOLE
ARC SET
ADJUSTMENT
NOZZLE TURRET TOP
2
ADJUSTING THE RIGHT (FIXED) SIDE OF ARC
If the right side of the arc is not properly aligned, the sprinkler may spray in areas not intended for watering such
as driveways or adjacent properties. The r ight side arc can easily be realigned.
OPTION 1:
REPOSITION CAN ON THE FITTING.
Turn the spr inkler can and the fitting below it left or right to the desired position. This may require temporary
removal of the soil around the sprinkler to allow you to grip the sprinkler can.
OPTION 2:
REMOVE INTERNAL RISER ASSEMBLY AND REPOSITION.
Unscrew the top counter-clockwise and remove the internal riser assembly from the can. Once removed with
nozzle turret at its “right start,” reposition riser assembly so that nozzle arrow points to the desired start position.
Replace riser assembly back in the can and screw on the top.
At this point you have realigned the right arc stop, and you can adjust the left arc to an appropriate setting.
ARC
D
ADJUSTMENT
KEY
HEX FOR
A
NOZZLE
RETENTION
SCREW
UNIVERSAL TOOL
NOZZLE
NOZZLE
PRONGS
C
FLAT BLADE
SCREWDRIVER
B
PULL UP KEY
LEFT RIGHT
LEFT
STOP
RIGHT
START

3
ADJUSTING THE LEFT (VARIABLE) SIDE OF THE ARC
INCREASING
THE ARC: Insert the plastic key end “D” of the universal
tool into the arc set adjustment slot.While holding the nozzle turret at
the “right start,” turn the universal tool clockwise. Each full 360° turn
of the universal tool will increase the arc 90°.Adjust to any arc between
40° and 360°.The universal tool will stop turning, or there will be
ratcheting noise, when the maximum arc of 360° has been reached.
DECREASING
THE ARC: Inser t the plastic key end “D” of the universal
tool into the arc set adjustment slot.While holding the nozzle turret at
the right start, tur n the universal tool counter-clockwise. Each full 360°
turn of the universal tool will decrease the arc 90°. Adjust to any arc
between 40° and 360°. The universal tool will stop turning, or there will
be a ratcheting noise, when the minimum arc of 40° has been reached.
SPRINKLER INSTALLATION
1
INSTALL AND BURY
Do not use pipe dope.Thread the sprinkler on the pipe. Bury the
sprinkler flush to grade. NOTE: Gear driven sprinklers and pop-up
sprays should not be installed on the same watering zone.
2
INSPECTING THE FILTER
Unscrew the top and lift the complete sprinkler assembly out of the
housing can.The filter is located on the bottom of the sprinkler
assembly and can be easily pulled out, cleaned and re-installed.
3
WINTERIZA TION TIPS
When using an air compressor to remove water from the system
please note the following:
1) Do not exceed 30 PSI.
2) Always introduce air into the system gradually to avoid air
pressure surges. Sudden release of compressed air into the
sprinkler can cause damage.
3) Each zone should run no longer than 1 minute on air. Spr inklers
turn 10 to 12 times faster on air than on water. Over spinning
rotors on air can cause damage to the internal components.
INSTRUCCIONES DE AJUSTE DEL ASPERSOR DE TURBINA RPS
SPRINKLER
ASSEMBLY
HOUSING
CAN
KEY IN KEYHOLE
LEFT
UNIVERSAL TOOL
PULL UP KEY
FLAT BLADE
SCREWDRIVER
ARC
ADJUSTMENT
KEY
HEX FOR
NOZZLE
RETENTION
SCREW
A
C
B
D
OBSERVACIÓNES: El RPS viene configurado previamente de fábrica con un
ajuste del sector a 180° e incluye la tobera n.° 3 preinstalada.
CAMBIO DE LA TOBERA
1
CÓMO QUITAR EL TORNILLO DE SUJECIÓN
Utilice el extremo “A”de la llave hexagonal de la herramienta universal,
para quitar el tornillo de sujeción de la tobera gire en el sentido contrario
al de las agujas del reloj, y en el sentido de las agujas del reloj para
volverlo a colocar.
2
EXTENSIÓN DE LA TURBINA EMERGENTE
Inserte el extremo “B” de la herramienta universal en el orificio situado en
la parte superior de la cabeza giratoria y gire la llave 1/4 de vuelta para
asegurarse de que la llave no se sale del agujero cuando levante
el aspersor.Tire con fuerza para acceder a la tobera y sujete el vástago
con una mano para poder acceder al cambio de tobera.
HERRAMIENTA UNIVERSAL
LLAVE PARA
D
AJUSTE DEL
SECTOR
LLAVE
A
HEXAGONAL
DESATORNILLADOR
C
DE PUNTA PLANA
B
LLAVE PARA
EXTENDER LA
TURBINA
ORIFICIO
AJUSTE
DEL SECTOR
TAPA
TORNILLO
´
DE SUJECION
DE LA TOBERA