K-Rain RPS Setting Instructions Manual

RPS GEAR DRIVEN SPRINKLER SETTING INSTRUCTIONS
CHANGING A NOZZLE
1
REMOVING THE NOZZLE RETENTION SCREW
Use the hex key end “A” of the universal tool to remove the nozzle retention screw by turning counter-clockwise to remove and clockwise to re-install.
2
PULL UP THE RISER
3
REMOVING THE NOZZLE
With the nozzle retention screw removed, the nozzle may be removed by either turning on the water (wear safety glasses when using this method), or by pulling outward on the nozzle prongs with a pair of needle-nose pliers.
4
INSTALLING A NOZZLE
Press the desired nozzle into the nozzle socket.Make sure the nozzle number is visible and the nozzle “prongs” are up.Then, re-install the nozzle retention screw. NOTE: The nozzle retention screw is also a break-up screw and used to adjust the distance of the spray.
SETTING THE ARC ADJUSTMENT
NOTE: The RPS gear dr iven sprinkler has a fixed right start and an adjustable left stop.
1
POSITIONING NOZZLE TURRET TO ITS “RIGHT START”
Place your finger on the top center of the nozzle turret. Rotate the turret counter-clockwise to the left stop to complete any interrupted rotation cycle. Rotate the nozzle turret clockwise to the “right start.” This is the fixed side of the arc.The nozzle turret must be held in this position for arc adjustments.The “right start” does not change.
NOTE: The RPS is factory preset with a 180° arc setting, and includes a pre-installed #3 nozzle.
KEY IN KEYHOLE
NOZZLE TURRET
NOZZLE RETENTION SCREW
NOZZLE SOCKET
NOZZLE RETENTION SCREW
KEYHOLE
ARC SET ADJUSTMENT
NOZZLE TURRET TOP
2
ADJUSTING THE RIGHT (FIXED) SIDE OF ARC
If the right side of the arc is not properly aligned, the sprinkler may spray in areas not intended for watering such as driveways or adjacent properties. The r ight side arc can easily be realigned.
OPTION 1:
REPOSITION CAN ON THE FITTING.
Turn the spr inkler can and the fitting below it left or right to the desired position. This may require temporary removal of the soil around the sprinkler to allow you to grip the sprinkler can.
OPTION 2:
REMOVE INTERNAL RISER ASSEMBLY AND REPOSITION.
Unscrew the top counter-clockwise and remove the internal riser assembly from the can. Once removed with nozzle turret at its “right start,” reposition riser assembly so that nozzle arrow points to the desired start position. Replace riser assembly back in the can and screw on the top.
At this point you have realigned the right arc stop, and you can adjust the left arc to an appropriate setting.
ARC
D
ADJUSTMENT KEY
HEX FOR
A
NOZZLE RETENTION SCREW
UNIVERSAL TOOL
NOZZLE NOZZLE PRONGS
C
FLAT BLADE SCREWDRIVER
B
PULL UP KEY
LEFT RIGHT
LEFT STOP
RIGHT START
3
ADJUSTING THE LEFT (VARIABLE) SIDE OF THE ARC INCREASING
THE ARC: Insert the plastic key end “D” of the universal
tool into the arc set adjustment slot.While holding the nozzle turret at the “right start,” turn the universal tool clockwise. Each full 360° turn of the universal tool will increase the arc 90°.Adjust to any arc between 40° and 360°.The universal tool will stop turning, or there will be ratcheting noise, when the maximum arc of 360° has been reached.
DECREASING
THE ARC: Inser t the plastic key end “D” of the universal
tool into the arc set adjustment slot.While holding the nozzle turret at the right start, tur n the universal tool counter-clockwise. Each full 360° turn of the universal tool will decrease the arc 90°. Adjust to any arc between 40° and 360°. The universal tool will stop turning, or there will be a ratcheting noise, when the minimum arc of 40° has been reached.
SPRINKLER INSTALLATION
1
INSTALL AND BURY
Do not use pipe dope.Thread the sprinkler on the pipe. Bury the sprinkler flush to grade. NOTE: Gear driven sprinklers and pop-up sprays should not be installed on the same watering zone.
2
INSPECTING THE FILTER
Unscrew the top and lift the complete sprinkler assembly out of the housing can.The filter is located on the bottom of the sprinkler assembly and can be easily pulled out, cleaned and re-installed.
3
WINTERIZA TION TIPS
When using an air compressor to remove water from the system please note the following:
1) Do not exceed 30 PSI.
2) Always introduce air into the system gradually to avoid air
pressure surges. Sudden release of compressed air into the sprinkler can cause damage.
3) Each zone should run no longer than 1 minute on air. Spr inklers turn 10 to 12 times faster on air than on water. Over spinning rotors on air can cause damage to the internal components.
INSTRUCCIONES DE AJUSTE DEL ASPERSOR DE TURBINA RPS
SPRINKLER ASSEMBLY
HOUSING CAN
KEY IN KEYHOLE
LEFT
UNIVERSAL TOOL
PULL UP KEY
FLAT BLADE SCREWDRIVER
ARC ADJUSTMENT KEY
HEX FOR NOZZLE RETENTION SCREW
A
C
B
D
OBSERVACIÓNES: El RPS viene configurado previamente de fábrica con un ajuste del sector a 180° e incluye la tobera n.° 3 preinstalada.
CAMBIO DE LA TOBERA
1
CÓMO QUITAR EL TORNILLO DE SUJECIÓN
Utilice el extremo “A”de la llave hexagonal de la herramienta universal, para quitar el tornillo de sujeción de la tobera gire en el sentido contrario al de las agujas del reloj, y en el sentido de las agujas del reloj para volverlo a colocar.
2
EXTENSIÓN DE LA TURBINA EMERGENTE
Inserte el extremo “B” de la herramienta universal en el orificio situado en la parte superior de la cabeza giratoria y gire la llave 1/4 de vuelta para asegurarse de que la llave no se sale del agujero cuando levante el aspersor.Tire con fuerza para acceder a la tobera y sujete el vástago con una mano para poder acceder al cambio de tobera.
HERRAMIENTA UNIVERSAL
LLAVE PARA
D
AJUSTE DEL SECTOR
LLAVE
A
HEXAGONAL
DESATORNILLADOR
C
DE PUNTA PLANA
B
LLAVE PARA EXTENDER LA TURBINA
ORIFICIO
AJUSTE DEL SECTOR
TAPA
TORNILLO
´
DE SUJECION DE LA TOBERA
Loading...