BSR100N™ Programming Guide
Part 15.109 Subpart (B)
radiated spurious
emissions. Part
FCC rules and reg.
under
10-15 VDC
Tx/Rx mod, Tx timer,
power trouble, LD, Low
Bat, Ovrl., CM, RSSI
Spurious and image
rejection
Power 50+10log
(Pout)= 60dB or 70 dB
whichever is less
Spurious/Harmonics
requirements
2.2 kHz, (0.7V p-p
1kHz signal)
Deviation for input
audio signal
Frequency stability
at operating temp.
range
Tx Current
consumption max
169x150x44 mm
(6.6"x5.9"x1.7)
Using KP’s GUP5000™ Utility Program,
the BSR100N™ parameter values listed
below can be programmed or modified.
An RSINT001 adapter connects between
BSR100 and a PC (see Figure 3).
Transmit frequency (MHz)
Receiver frequency (MHz)
TX time out (0-240 sec.)
Figure 3: BSR100N™
PC Connection Configuration
Operating Instructions
Connecting BSR100N™ to GUP5000™
(utility program)
Loading Parameter Values
Changing Parameter Values
Updating Parameter Value Changes
Confirming Parameter Value Changes
Activating Self Test
Connecting BSR100N™ to
GUP5000™
1. Connect BSR100N™ to a PC using the
RSINT001 adapter (see Figure 3).
2. Click StartPrograms
KP UtilitiesGUP5000.
The GUP5000 main screen displays,
showing the device type, version, Status
device diagnostic, and parameters.
See Example in figure 4.
Figure 4: Gup5000™ Main Screen
Loading Parameter Values
Parameter values must be loaded after
connecting the GUP5000™ utility software.
To Load Parameter Values
1. From the GUP5000 main screen, click
Prompt ? (Alt P).
2. Click Read (Alt R). The name of the
device type, version, and suitable
parameters are displayed.
Changing Parameter Values
Parameter values can be changed, as required:
Type the new parameter value in the
designated parameter text box.
Updating Parameter Value Changes
1. Click Send (Alt S).
The Send Warning dialog box
displays “Are you sure?”
2. Choose one:
Click Yes, to update parameter
changes.
OR
Click No, to return to the
GUP5000 main screen without
updating changes.
Figure 5: Gup5000™ Modulation Table
Confirming Parameter Changes
Ensure that any parameter value changes
made are updated.
To Confirm Parameter Changes
From the GUP5000 main screen, click Read
(Alt R).
The GUP5000 main screen displays the
updated parameter values.
Performing SELF TEST
After parameter values are loaded,
Perform SELF TEST:
1.Disconnect BSR100N™ from the
PC
2.Press the Self- Test button.
3.Observe the Self-Test Led.
(Refer to Table 2 for SELF-TEST results.)
On-Screen HELP
To view a brief explanation of any
BSR100N™ parameter, click the required
parameter text box. The cursor will appear
in the designated text box, and the valid
parameter range, with a brief explanation,
displays at the bottom of the screen.
Technical Specification
90