KP Electronic Systems KPBSR100N INSTALLATION MANUAL

BSR100N™ Programming Guide
General
VHF
Band
136-174 MHz
Frequency Range
12.5 KHz
Channel Spacing
Fully PC programming
Programming
Part 15.109 Subpart (B) radiated spurious emissions. Part
FCC rules and reg. under 10-15 VDC
Operating Voltage
Tx/Rx mod, Tx timer, power trouble, LD, Low Bat, Ovrl., CM, RSSI
Diagnostics
Receiver
-116dBm @ 12 dB SINAD
Sensitivity analogy
-119dBm
MDS sensitivity
60 dB for 12.5 KHz
Adj. Ch. Selectivity
>60dB
Intermodulation response
70dB
Spurious and image rejection
250 mV p-p
Audio out signal
120ma
RX current consumption
Transmitter
10w
Nominal output power
Power 50+10log (Pout)= 60dB or 70 dB whichever is less
Spurious/Harmonics requirements
2.2 kHz, (0.7V p-p 1kHz signal)
Deviation for input audio signal
±2.5 ppm @ -30ºC to 60ºC
Frequency stability at operating temp. range
2.8A+-10%
Tx Current consumption max
Physical dimension
169x150x44 mm (6.6"x5.9"x1.7)
Size
0.65 Kg (1.44 Lbs)
Weight
Rsint001
Using KP’s GUP5000™ Utility Program, the BSR100N™ parameter values listed below can be programmed or modified. An RSINT001 adapter connects between BSR100 and a PC (see Figure 3).
Receiver frequency (MHz)
TX time out (0-240 sec.)
Figure 3: BSR100N™
PC Connection Configuration
Operating Instructions
Connecting BSR100N™ to GUP5000
(utility program)
Loading Parameter Values
Changing Parameter Values
Updating Parameter Value Changes
Confirming Parameter Value Changes
Activating Self Test
Connecting BSR100N™ to GUP5000
1. Connect BSR100N™ to a PC using the
RSINT001 adapter (see Figure 3).
2. Click StartPrograms KP UtilitiesGUP5000.
The GUP5000 main screen displays, showing the device type, version, Status device diagnostic, and parameters.
See Example in figure 4.
Figure 4: Gup5000™ Main Screen
Loading Parameter Values
Parameter values must be loaded after connecting the GUP5000™ utility software.
To Load Parameter Values
1. From the GUP5000 main screen, click Prompt ? (Alt P).
2. Click Read (Alt R). The name of the device type, version, and suitable parameters are displayed.
Changing Parameter Values
Parameter values can be changed, as required:
Type the new parameter value in the
designated parameter text box.
Updating Parameter Value Changes
1. Click Send (Alt S). The Send Warning dialog box displays “Are you sure?”
2. Choose one:
Click Yes, to update parameter
changes.
OR
Click No, to return to the
GUP5000 main screen without updating changes.
Figure 5: Gup5000™ Modulation Table
Confirming Parameter Changes
Ensure that any parameter value changes made are updated.
To Confirm Parameter Changes
From the GUP5000 main screen, click Read (Alt R).
The GUP5000 main screen displays the updated parameter values.
Performing SELF TEST
After parameter values are loaded, Perform SELF TEST:
1.Disconnect BSR100N™ from the PC
2.Press the Self- Test button.
3.Observe the Self-Test Led.
(Refer to Table 2 for SELF-TEST results.)
On-Screen HELP
To view a brief explanation of any BSR100N™ parameter, click the required parameter text box. The cursor will appear in the designated text box, and the valid parameter range, with a brief explanation, displays at the bottom of the screen.
Technical Specification
90