Installation Instructions and Homeowner’s Manual
ANSI/UL1278. MOVABLE AND WALL-OR CEILING HUNG ELECTRIC ROOM HEATERS
INSTALLER: DO NOT DISCARD THIS MANUAL-LEAVE FOR HOME OWNER
WARNING! IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE MAY RESULT
CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
FOR YOUR SAFETY
DO NOT STORE
OR USE GASOLINE OR OTHER
FLAMMABLE VAPORS OR LIQUIDS
IN THE VICINITY OF THIS OR ANY
OTHER APPLIANCE
EF4901
EF5002
EF5003
ES5001
EF5109
Freestanding
Electric Fire
lace
KW-VL063-01W-0604
Kozy-World ®
![](/html/fc/fc79/fc79e25033a8dd9a2bfd1c85089e68de1843e35255f71f9ef315b6553bf29b76/bg2.png)
TABLE OF CONTENTS
PLEASE READ THE INSTALLATION & OPERATION INSTRUCTIONS BEFORE
USING THIS APPLIANCE
IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to
follow these instructions may result in a possible electric shock, fire hazard and will void the
warranty.
Important instructions ………………………………………………………...2
General……………………………………………………………………….2
Locating Your Electric Fireplace……………………………………………2
Clearance To Combustibles………………………………………………...3
Electrical Connections…..…………………………………………………..3
Electrical Specifications……………………………………………………..3
Service Instructions………………………………………………………………..3
Replacing Light Bulbs………………...……………………………………..3
Glass Information…………………………………………………………….4
Maintenance of Motors………………………………………………………4
Electrical Wiring Diagram……………………………………………………4
Operating Instructions……………………………...……………………………...5
On/Off Switch………………………………………………………………….5
Heater Control……………………………………………………………….. 5
Instructions for power………………………………………………………...5、6
Specifications………………………………………………………………….6
Replacement Parts List (EF5002 or EF5003) …………………………………..7
Replacement Parts List (EF4901) ………………………………………………..8
Replacement Parts Pictures…………………………………………………9
Replacement Parts List (ES5001)………………………………………………..10
Replacement Parts Pictures…………………………………….………….11
Replacement Parts List (EF5109) ……………………………………………….12
Replacement Parts Pictures………………………………………………..13
Installing The Legs…………………………………………………………………14
![](/html/fc/fc79/fc79e25033a8dd9a2bfd1c85089e68de1843e35255f71f9ef315b6553bf29b76/bg3.png)
IMPORTANT INSTRUCTIONS
GENERAL
2
1. Read all instructions before using this appliance.
2. This appliance is hot when in use. T o avoid burns, do
not let bare skin touch hot surfaces. Keep
combustible materials, such as furniture, pillows,
bedding, papers, clothes, and curtains at least 3
feet(1m.) from the front of this appliance.
3. CAUTION: Extreme caution is
necessary when any heater is used
by or near children or invalids and
whenever the heater is left Operating
and unattended.
4. Always unplug heater when not in
use.
5. Do not operate any heater with a
damaged cord or plug or after the
heater malfunctions, has been
dropped or damaged in any manner.
6. Any repairs to this appliance should be carried out by
a qualified service person.
7. Under no circumstances should this electric fireplace
be modified. Parts having to be removed fo
servicing must be replaced prior to operating this
electric fireplace again
.
8. Do not use outdoors.
9. This heater is not intended for use in bathrooms,
laundry areas or similar indoor locations. Never use
this appliance near a bathtub or other wate
container.
10. Do not run cord under carpeting. Do not cover cord
with throw rugs, runners or the like.
Arrange cord
away from traffic areas and where it will not be
tripped over.
11. To disconnect this appliance, turn controls to the of
position and remove plug from outlet.
12. Connect to properly grounded outlets only.
13. When this appliance is installed, it must be
electrically grounded in accordance with local
codes with the current CSA C22.1 Canadian local
codes of for USA installations. Follow local codes
and National Electrical Code,
ANSI/NFP
NO.70 and Canadian Cord: CZ 22.2 NO.0.
14. Do not insert or allo w foreign objects to enter an
ventilation or exhaust opening as this may cause
electric shock, fire or damage to the appliance.
15. To prevent fire, do not block air intakes or exhaust
in any manner. Do not use on soft surfaces, such
as a bed, where openings may become blocked.
16. This appliance has hot and arcing or sparking
parts inside. Do not use it in areas where gasoline,
paint, or flammable liquids are used or stored. This
electric fireplace should not be used as a drying
rack for clothing, Also, do not have Christmas
stockings or decorations hung on or near it.
17. Use this appliance only as described in this
manual. All other uses not recommended by the
manufacturer may cause fire, electric shock, o
injury.
18. Avoid the use of an extension cord because it ma
overheat and cause a fire hazard. However if you
must use an extension cord, the cord shall be
NO.16, 1900 Watts. The extension cord must be a
three wire cord with grounding type plug and cord
connector.
19.
SAVE THESE INSTRUCTIONS.
LOCATING YOUR ELECTRIC
FIREPLACE
Your new freestanding electric fireplace may be
installed virtually anywhere in your home.
However when choosing a location for your
new electric fireplace, ensure that the general
instructions are followed. For best effect results, install
the electric fireplace out of direct sunlight.
![](/html/fc/fc79/fc79e25033a8dd9a2bfd1c85089e68de1843e35255f71f9ef315b6553bf29b76/bg4.png)
SERVICE INSTRUCTIONS
CLEARANCE TO COMBUSTIBLES
ELECTRICAL CONNECTION
15 AMP, 120 Volt,60Hz circuit with a properly grounded
outlet is required. Preferably, the stove will be on a
dedicated circuit. Other appliances on the same circuit
may cause the circuit breaker to trip or the fuse to blo
when the heater is on operation. The unit comes standard
with a 6’ (1828mm) long three wire cord exiting from the
rear of the fireplace. Plan the installation to avoid the use
of an extension cord. If an extention cord must be used, it
must be a minumum 16 AWG three wire with grounding
type plug connector and rated no less than 1900 Watts.
Back………………0”/0mm
Sides……………..0”/0mm
Floor……………..0”/0mm
Top……………….24”/610mm
WARNING: Electrical outlet wiring
must comply with local building
codes and all other applicable
regulations to reduce the risk o
fire, electrical shock and injury.
WARNING: Do not use this
fireplace if any part of it has been
under water. Immediately call a
qualified service technician to
inspect the fireplace and replace
any part of the electrical system i
necessary.
ELECTRICAL SPECIFICATIONS
Voltage………………120 VAC/60Hz
T ota l Amps…………..1 1.3 Amps
Total Watts…………..1345 Watts
Heater Ratings………1200 Watts
WARNING: Disconnect powe
maintenance or cleaning to
reduce the risk of fire, electrical
shock or personal injury
REPLACING LIGHT BULBS
This fireplace uses two clear 120 Volt, 60 Watt, E-12
socket base light bulbs (small base, chandelier candle
type).The 60 Watt bulbs are located under the log
set/ember bed. For convenience, if one of the bulbs
burns out, it may be a good idea to replace both of the
light bulbs.
1. Turn off power to the unit by unplugging the powe
cord.
2. Let fireplace cool if it has been operating.
3. Remove the two fixing self-tapping screws on the
screen. Pull the screen upward a little bit, and then
out.
4. Remove the screws that secure the log set in
position.
5. Examine the bulbs to determine which bulbs need to
be replaced.
6. While holding the socket, unscrew the defective
bulb(s).
WARNING: Do not exceed 60
Watts per bulb. Use of higher
rated bulbs may result in a fire
causing property damage and
personal injury.
3
7. Install the new light bulb(s) by holding the socket
and screwing them.
8. Reinstall the log set and screen. Follow the
above procedure in reverse order.
9. The diameter of the pilot light bulb is 5mm. If the
pilot light bulb need to be replaced, follow steps
1,2,3,4 above. Then use the pilot light bulb
socket
w/wiring assembly replace the primar
pilot part, and connect wires according to
primary connection . Then follow step 8 above.
![](/html/fc/fc79/fc79e25033a8dd9a2bfd1c85089e68de1843e35255f71f9ef315b6553bf29b76/bg5.png)
MAINTENANCE OF MOTORS
The motors used on the fan and flame generato
assembly are prelubricated for extended bearing life
and require no further lubrication. However, periodic
cleaning/vacuuming of the fan/heater unit is
recommended.
WARNING: Make sure that the
power is turned off before
proceeding.
ELECTRICAL WIRING DIAGRAM
ny electrical repairs or rewiring of this unit should be carried out by a licensed electrician in accordance
with national and local codes.
If repairing or replacing any electrical component or wiring, the original wire
routing, color coding and securing location must be followed.
GLASS INFORMATION
1. Under no circumstances should this
product be operated with missing o
broken glass.
2. Do not strike or slam the glass.
3. Do not use abrasive cleaners to clean the
glass.
4. Replacement glass is available from the
manufacturer and replacement should be
carried out by a qualified service person.
4
![](/html/fc/fc79/fc79e25033a8dd9a2bfd1c85089e68de1843e35255f71f9ef315b6553bf29b76/bg6.png)
Operating Instructions
This section provides easy step by step instructions for operating your fireplace.
1. Make sure the unit is unplugged from the power source。
2. Plug the fireplace into a 15AMP/120volt outlet. If the cord does not reach, you may use an
extension cord rated for a minimum of 1900 watts.
To access the controls, open the bottom of the fireplace at the front of the unit (see Figure A).
A. MAIN ON/OFF SWITCH
The on/off switch supplies power to all fireplace functions (heater/flame).
B. HEATER THERMOSTAT CONTROL
To adjust the temperature to your needs, turn the thermostat control completely clockwise to
turn on the heater. When the room reaches the desired temperature, turn the thermostat knob
counter clockwise until you hear a click. Leave it in this position to maintain the room
temperature at this setting. For additional heat, turn clockwise until you hear the click again and
the heater will turn on. To turn the heater off, switch the HEATER ON/OFF SWITCH to the OFF
position.
C. HEATER ON/OFF SWITCH
The HEATER ON/OFF SWITCH supplies power to the heater fan and the heater element.
NOTE: When switched ON, the heater fan will operate. The heater element may or may not be
on, depending on the thermostat control setting (see “HEATER THERMOSTAT CONTROL”).
When the HEATER/FAN pilot light is lighting, it indicate that the heater is on.
Warning: During any service of this appliance, the power to the unit must be turned off. It
is not acceptable to use the “ON/OFF” switch to meet this requirement. (Refer to
operating instruction section)
D. INSTRUCTIONS FOR POWER
This heater is for use on 120 volts only. The cord has a plug as shown at A in the following figure.
An adapter as shown at C is available for connecting three-blade grounding-type plugs to
two-slot receptacles. The green grounding lug extending from the adapter must be connected to
a permanent ground such as a properly grounded outlet box. The adapter should not be used if
a three-slot grounded receptacle is available. (For U.S. only)
For Canada the use of an adapter is NOT permitted. You must contact a qualified electrician.
5
Figure A
![](/html/fc/fc79/fc79e25033a8dd9a2bfd1c85089e68de1843e35255f71f9ef315b6553bf29b76/bg7.png)
(Adaptor NOT permitted in Canada)
Under CZ22.2 NO. 0 standard
SPECIFICATIONS:
Model: EF5003
Voltage: 120V/60HZ Total Amps: 11.3A
Total Watts: 1345W Heating Ratings: 1200W
Dimensions, Inches (H x W X D)
Fireplace 38-3/16”x26-3/8”x14-1/8”
Carton 37”x29-5/16”x15-5/16”
Weight, Pounds
Fireplace 72
Shipping 83
Model: EF4901
Voltage: 120V/60HZ Total Amps: 11.3A
Total Watts: 1345W Heating Ratings: 1200W
Dimensions, Inches (H x W X D)
Fireplace 38-3/16”x26-3/8”x14-1/8”
Carton 37”x29-5/16”x15-5/16”
Weight, Pounds
Fireplace 72
Shipping 83
Model: EF5002
Voltage: 120V/60HZ Total Amps: 11.3A
Total Watts: 1345W Heating Ratings: 1200W
Dimensions, Inches (H x W X D)
Fireplace 38-3/16”x26-3/8”x14-1/8”
Carton 37”x29-5/16”x15-5/16”
Weight, Pounds
Fireplace 72
Shipping 83
Model: ES5001
oltage: 120V/60HZ Total Amps: 11.3A
Total Watts: 1345W Heating Ratings: 1200W
Dimensions, Inches (H x W X D)
Fireplace 33-9/16”x23-1/8”x13-9/16”
Carton 36-7/8”x26-1/8”x16-1/2”
Weight, Pounds
Fireplace 40
Shipping 50
Model: EF5109
oltage: 120V/60HZ Total Amps: 11.3A
Total Watts: 1345W Heating Ratings: 1200W
Dimensions, Inches (H x W X D)
Fireplace 38-3/16”x26-3/8”x14-1/8”
Carton 41-3/8”x29-5/16”x17-3/8”
Weight, Pounds
Fireplace 79
Shipping 95
6
![](/html/fc/fc79/fc79e25033a8dd9a2bfd1c85089e68de1843e35255f71f9ef315b6553bf29b76/bg8.png)
Replacement Parts List
EF5002&EF5003
Item # Part Description Part Number
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
Log set
Fan/Heater Assembly
Synchronization Motor-120Volt AC w/Terminal
Cord Power 16/3 HPN w/Terminals
ON/OFF Switch
Heater Control (Thermostat)
Heater Control Knob
Flame Generator Assembly
Light Bulb Socket w/Wiring Assembly
Screen
Top Panel
Side Panel
Lower Front Panel
Door
Brass Knob
Back Panel
Middle Decorating Panel
Base
Leg
Upper Decorating Frame
Upper Decorating Wire
Upper (Mid) Louver
Rome Column
Rome Column Decorating Assembly
Switch Mount panel (not shown)
Right(Left) Bracket of Motor(not shown)
Pilot Light Bulb Socket w/ Wiring Assembly
VL050-01
NFHTX186/VB17-000
VL051-01
NFHL008
PF06-0401-A
VL053-01
NFHL012
VL205-B
VL054-01
EL008-01
EL040-01A
EL015-01
EL012-01
EL013-01
EL013-01A
VL019-01
EL016-01
VL024-01
SL017-04A
EL010-01C
EL011-01
VL017 (EL003-01)
EL021-01
030C
VL004-01F
VL008/009-01
VL075-01
7
![](/html/fc/fc79/fc79e25033a8dd9a2bfd1c85089e68de1843e35255f71f9ef315b6553bf29b76/bg9.png)
Replacement Parts List
EF4901
Item # Part Description Part Number
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
Log set
Fan/Heater Assembly
Synchronization Motor-120Volt AC w/Terminal
Cord Power 16/3 HPN w/Terminals
ON/OFF Switch
Heater Control (Thermostat)
Heater Control Knob
Flame Generator Assembly
Light Bulb Socket w/Wiring Assembly
Screen
Top Panel
Side Panel
Lower Front Panel
Door
Brass Knob
Back Panel
Middle Decorating Panel
Base
Leg
Upper Decorating Frame
Upper Decorating Wire
Upper (Mid) Louver
Rome Column
Rome Column Decorating Assembly
Switch Mount panel (not shown)
Right(Left) Bracket of Motor(not shown)
Pilot Light Bulb Socket w/ Wiring Assembly
VL050-01
NFHTX186/VB17-000
VL051-01
NFHL008
PF06-0401-A
VL053-01
NFHL012
VL205-B
VL054-01
EL008-01
EL040-06H
VL107
VL103
VL104
EL013-01A
VL019-01
EL016-01H
VL024-01
EL017-01A
EL010-01C
EL011-01
VL017 (EL003-01)
VL108
EL021-06BH
VL004-01F
VL008/009-01
VL075-01
8