kozy heat WLD-P Maintenance Manual

OPERATING
MAINTENANCE MANUAL
Quality Fireplaces for Life
D
INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE
D
O
N
O
T
R
D
I
S
C
A
Contact local building or fire officials about restrictions
and installation inspection requirements in your area.
USE ONLY HIGH QUALITY FUEL IN THIS STOVE TO AVOID EXCESSIVE BUILD UP OF DUST IN
THE HOPPER AND AUGER SYSTEM WHICH CAN CREATE A DANGEROUS FIRE RISK.
Please read this entire manual before installation and use
of the pellet fuel burning room heater.
Failure to follow these instructions could result in property
damage, bodily injury or even death.
MAINTENANCE INSTRUCTIONS MUST BE FOLLOWED
TO OBTAIN OPTIMUM PERFORMANCE AND TO AVOID
POTENTIAL FIRE RISK.
WOODLAND OPERATING JULY 08-REV01
TABLE OF CONTENTS
Features…………………………………………………………………………………………….2
Safety Information………………………………………………………………………………3-4
Installation………………………………………………………...3
Precautions………………………………………………………..3
Safety Devices……………………………………………………..4
Circuit Control Board…………………………………………………………………………….5
Operating Instructions………………………………………………………………………….6-8
Fuel Quality / Storage…………………………………………….6
Pre-lighting Checklist…………………………………………….6
Thermostat Control…………………………………………..…..6
Prior to Each Burn…...….………………………………………..7
Lighting Your Stove………..………………...…………………...8
Shutting Stove Off…………………...……………………………8
Diagnostic Features…………………………………………….....9
Diagnostic Features……………………………………………...10
Maintenance Instructions…………………………………………………………………..….8-10
Daily Maintenance………………………………………………...8
Weekly Maintenance…………………………………………...…9
2-Month Maintenance…………………………………………9-10
Annual Maintenance…………………………………………….10
Troubleshooting…………………………………………………………………………………..11
Control Board Diagnostics Troubleshooting…………………………………………………...11
Replacement Parts…………………..………………………………………………………..12-13
Description……………………………………………………….12
Illustration………………………………………………………..13
Complete warranty information and return to: Kozy Heat Fireplaces Attention: Warranty Registration P.O. Box 577 Lakefield, MN. 56150
Page 1
#WLD-P WOODLAND PELLET STOVE
Figure shown with optional decorative grill.
Circuit Control Board
Hopper Capacity:
80 lbs
Hearth Extension
Ash Drawer with easy access
Electronic Ignition - Standard
Thermostatic Control - Optional (recommended)
Heat Exchange Tube Cleaner
Ash Dump Handle
Page 2
SAFETY INFORMATION
INSTALLATION: This stove must be installed by a qualified installer in accordance with the installation manual provided. Improper
installation and /or maintenance may create a fire hazard, resulting in an unsafe condition, poor performance, and may void your warranty.
1. Please read this entire manual before operating this stove. Make sure the installer of this product reviews the operating procedures, all maintenance requirements, and answers any questions you may have.
2. This stove is approved for use with wood pellets only.
3. Please be aware that it is normal for the stove to give off odors during the initial burn period. This is short-term and the result of paint curing and other agents used in the manufacturing process.
4. This stove will be HOT WHILE IN OPERATION. Keep children, clothing, and furniture away from all stove surfaces. Direct contact with stove surfaces while in operation may cause severe burns.
5. This stove has safety interlock switches built into the circuit control board which will not allow continuous burning in the event of a problem. Keep the door, ash drawer and hopper lid closed whenever this stove is in operation. All exhaust connections must be tightly sealed to prevent the possibility of carbon monoxide from entering the home.
6. The combustion air intake pipe should be connected to an outside fresh air source. This will prevent ‘smoke back’ into the house in circumstances such as a power outage.
CAUTION: Operate this stove only with the fuel hopper lid closed. Failure to do so may result in emission of combustion products from the hopper under certain conditions. This stove is equipped with a safety interlock device which will turn off auger operation when the hopper lid is opened. To prevent the fire in burn pot from extinguishing, fill hopper quickly. If hopper lid is left open too long causing the fire to burn out, the control board will continue to operate as normal, but the
auger will not cycle until the stove has been shut off and restarted.
SAFETY PRECAUTIONS
DISPOSAL OF ASHES: Ashes should be placed in a metal container with a tight fitting lid. The closed container of ashes should be
placed on a noncombustible floor or on the ground, well away from all combustible materials, pending final disposal. If the ashes are dis­posed of by burial in soil or otherwise locally dispersed, they should be retained in the container until all cinders have thoroughly cooled.
NEVER USE GASOLINE, gasoline-type lantern fluid, kerosene, charcoal lighter fluid or similar liquids to start or ‘freshen up’ a fire in the stove. Keep all such liquids well away from stove while in use.
SOOT AND FLY ASH: The products of combustion will contain small particles of flyash. Flyash will collect in the exhaust venting sys- tem and restrict the flow of flue gases. Incomplete combustion, such as occurs during startup, shutdown, or incorrect operation of the room heater will lead to some soot formation which will collect in the exhaust system. The exhaust venting system should be inspected at least once during the burn season to determine if cleaning is necessary.
DO NOT USE ANOTHER MANUFACTURER’S BURN POTS, GRATES, OR ANY OTHER COMPONENT WHICH HAVE NOT BEEN TESTED OR APPROVED FOR USE WITH THIS STOVE.
DO NOT OVER FIRE THIS STOVE. (OVERFILL BURN POT AT STARTUP OR HOLD AUGER BUTTON FOR LONG PERI­ODS OF TIME). Follow all instructions regarding the proper use of this stove.
CAUTION: The electrical components of this stove are not owner serviceable. Contact your dealer for proper diagnosis of any electrical problems that may occur and to provide servic
e.
Page 3