kozy heat DEL-36 Installation And Operation Manual

INSTALLATION AND OPERATION MANUAL
DIRECT VENT LINEAR FIREPLACE
IN S TALLER : L E AVE THIS MANU AL WIT H THE A PPLIAN CE.
CO NSUMER: R E TAIN THIS MA NUAL F O R FUTURE REFE RENCE .
This applianc e ma y be installe d in an aftermarke t permanentl y located, manufactured home (USA only) or mobile home where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity
of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS: ◙ Do not light any appliance. ◙ Do not touch any electrical switch: do not use any phone in your building. ◙ Immediately call gas supplier from a neighbors phone. Follow the gas supplier instructions. ◙ If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or the gas supplier.
WARNING
HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS.
Report No. 216-F-14b-6.5
August 2011
DEL-36-REV-06
www.kozyheat.com
INTRODUCTION
Read this manual before installing or operating this appliance.
Please retain this owner‟s manual for future reference.
CONGRATULATIONS!
We welcome you as a new owner of a Kozy Heat gas fireplace. Kozy Heat products are designed with superior components and materials and assembled by trained craftsmen who take pride in their work. The burner and valve assembly are 100% test-fired and the complete fireplace is thoroughly inspected before packaging to ensure that you receive a quality product. Our commitment to quality and customer satisfaction have remained the same for over 30 years. We offer a complete line of gas and wood fireplaces, unique cabinets and stylish accessories to compliment any décor. Adding a fireplace is one of the best ways to increase the value of your home and we are proud to offer a network of dealers throughout the country to help make your experience everything you imagine. We pride ourselves in being dedicated to not only function and reliability, but customer safety as well. We offer our continual support and guidance to help you achieve the maximum benefit and enjoyment from your Kozy Heat gas fireplace.
Jim Hussong Dudley Hussong President Board Chairman
Homeowner Reference Information
We recommend that you record the following information about your fireplace.
Model Name:______________________________ Date purchased/installed:___________________________
Serial Number:____________________________ Location on fireplace:_______________________________
Dealership purchased from:__________________ Dealer Phone:____________________________________
Notes:___________________________________________________________________________________
________________________________________________________________________________________
________________________________________________________________________________________
PAGE 1
TABLE OF CONTENTS
INTRODUCTION
Introduction and Homeowner Reference Information 1
CONTENTS
Table of Contents 2
SAFETY INFORMATION
Safety Information 3
FEATURES
Features 4
COMMONWEALTH OF MASSACHUSETTS INFORMATION
Commonwealth of Massachusetts Information 5
SPECIFICATIONS
Fireplace Dimensions 6
Clearances 6
Components List 7
Additional Components Required 7
Installation Overview 7
Placement Clearance Requirements 7
FIREPLACE PREPARATION
Stand-Off Assembly & Installation 8
Nailing Flange Assembly & Installation 9
FRAMING
Wall Enclosure Rough Opening 10
Minimum Finished Opening Dimensions 10
Vertical Terminations 11
Horizontal Terminations 11
TYPICAL INSTALLATION OPTIONS
Typical Installation Options 12
MANTEL REQUIREMENTS
Mantel Requirements 12
GLASS FRAME / CONTEMPORARY FRAME
Glass Frame Assembly Removal / Installation 13
Contemporary Frame 13
OPTIONAL FAN KIT INSTALLATION
Optional Fan Kit Installation 13
GAS LINE CONNECTION
Gas Line Connection 14
VENTING
Approved Venting 15
Horizontal Vent System Clearances 15
Horizontal Termination Minimum / Maximum 15
#800-WPT Wall Pass-Thru Installation Instructions 16
Horizontal Min. / Max. Venting Illustrations 17
Horizontal Vent Heat Shield Installation Instructions 17
Typical Corner Installation 18
Vertical Vent System Clearances 18
Vertical Min. / Max. Venting Illustrations 18
Restrictor 19
Elbows 19
VENTING (cont.)
Horizontal & Vertical Combination Venting Illustrations 20
#800 Series Flex Vent Installation Instructions 21-22
Termination Vent Cap Location 23
Vent Termination Clearances 24
LIGHT KIT
Light Kit 25
GLASS MEDIA INSTALLATION
Glass Media Installation 25
CONTROL BOARD
Control Board Removal 26
Control Board Installation 26
OPERATING INSTRUCTIONS
Wiring Schematics 27
Valve and Pilot Assembly Components 28
Control Module Components 29
Remote Control Components 30
IPI Information 31
Remote Control Operation 32-34
Lighting and Shutdown Instructions 35-36
Pressure Testing 37
Error Codes 38
FINALIZING THE INSTALLATION
Burner Tube Adjustment / Troubleshooting 39
Restrictor Troubleshooting / Installation after Termination Completion 40
MAINTENANCE
Maintenance 41
TROUBLESHOOTING
Troubleshooting 42-43
CONVERSION KIT INSTRUCTIONS
Nat and LP Conversion Instructions 44-45
REPLACEMENT PARTS LIST
Replacement Parts List 46
WARRANTY
Warranty 47-48
PAGE 2
SAFETY INFORMATION
This fireplace has been tested to and complies with ANSI Z21.88-2009 CSA 2.33-2009 “VENTED GAS FIREPLACE HEATERS” CSA CAN/CGA
2.17-M91 (R2009) P.4.1-02 by OMNI-Test Laboratories, Portland, OR. Installation must conform with local building codes or in the absence of local building codes, with the National Fuel Gas Code, ANSIZ223.1/NFPA 54 - Current Edition, or the Natural or Propane Installation Code, CSAB149.1
Installation and repair should be done only by a qualified service person. The appliance should be inspected by a qualified service person before use. Annual inspection by a qualified service person is required to maintain warranty. More frequent cleaning may be required due to excessive lint from carpeting, bedding materials, etc. It is imperative that control compartments, burners and circulation air passageways of the appliance be kept clean.
If this appliance is installed directly on carpeting, tile or other combustible material other than wood flooring, the appliance shall be installed on a metal or wood panel extending the full width and depth of the appliance.
Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition.
Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children and others may be susceptible to accidental contact burns. A physical barrier is recommended if there are at risk individuals in the house. To restrict access to a fireplace or stove, install an adjustable safety gate to keep toddlers , young children and other at risk individuals out of the room and away from hot surfaces.
Clothing or other flammable material should not be place on or near the appliance.
Adequate accessibility clearances for servicing and proper operation must be maintained.
This appliance must not share or be connected to a chimney flue serving any other appliance.
Keep area around the appliance clear of combustible materials, gasoline and other flammable vapor and liquids.
The flow of combustion and ventilation air must not be obstructed.
Due to high temperatures the appliance should be located out of traffic and away from furniture and draperies.
The glass front or any part removed for servicing the appliance must be replaced prior to operating the appliance. Work should be done by a qualified service technician.
Clean glass only when cool and only with non-abrasive cleansers.
Do not operate this appliance with the glass/frame assembly removed, cracked or broken. The glass assembly, Part #DSL-057T, shall only be replaced as a complete unit, as supplied by Hussong Mfg. Co., Inc. Replacement of the glass assembly must only be performed by a licensed or qualified service person. DO NOT SUBSTITUTE MATERIALS.
Do not strike or slam glass assembly.
Any safety screen or guard removed for servicing the appliance must be replaced prior to operating the appliance.
Under no circumstances should any solid fuel (wood, coal, paper or cardboard etc.) be used in this appliance.
Keep burner and control compartment clean.
Do not use this fireplace if any part has been under water. Immediately call a qualified service technician to inspect this appliance and to replace any part of the control system and any gas control which has been under water.
PAGE 3
FEATURES
STANDARD FEATURES
High efficiency
High quality lifetime glass
23-3/4” x 30-1/16” (603mm x 764mm)
Curved black firebox liner
IPI control system with remote control
Engineer-designed burner system
Light Kit
Minnesota Energy Code compliant to 50 pascals
SAFETY FEATURES
Each unit factory tested!
Tested by OMNI - Test Laboratories
Sealed combustion chamber
Intermittent or Standing pilot ignition
Flame sensing system (safety shutoff)
Automatic pressure relief glass system
Battery back-up in the event of power failure (excluding fan)
Bedroom and mobile home approved
Canadian approved
OPTIONAL FEATURES
Curved stainless steel firebox liner overlay
Glass media kits in various colors - Required
Rock media (used with required glass media kit)
Flame accent-stainless steel (used with required glass media kit)
Contemporary frames in various designs and finishes - Required
Automatic fan kit (1) - 75 CFM
PAGE 4
COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS
NOTE: The following requirements reference various Massachusetts and national codes not contained in this manual.
For all sidewall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied:
INSTALLATION OF CARBON MONOXIDE DETECTORS
At time of installation of side wall horizontally vented gas fueled equipment, the installing plumber or gas-fitter shall observe that a hard wired carbon mon­oxide detector with an alarm and battery back-up is installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gas-fitter shall observe that a battery operated or hard wired carbon monoxide detector is installed on each additional level of the dwelling, building or structure served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors.
In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or attic, the hard wir ed carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level.
In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be installed.
APPROVED CARBON MONOXIDE DETECTORS
Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2 034 listed and IAS certified.
SIGNAGE
A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum of eight (8 ) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The sign shall read, in print no less the one-half inch (1/2) in size, “GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS”.
INSPECTION
The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.08 (2) (a) 1 through 4.
EXEMPTIONS
The following equipment is exempt from 248 CMR 5.08 (2) (a) 1 through 4:The equipment listed in Chapter 10 entitled “Equipment Not Required To Be Vented” in the most current edition of NFPA 54 as adopted by the Board; and Product Approved side wall horizontally vented ga s fueled equipment installed
in a room or structure separate from the dwelling, building or structure used in whole or in part for residential purposes.
MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM PROVIDED
When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the instructions provided by the manufacturer for installation of the equipment and the venting system shall include:
Detailed instructions for the installation of the venting system design or the venting system components; and
A complete parts list for the venting system design or venting system.
MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED
When the manufacturer of Product Approved side wall horizontally vented gas equipment does not provide the parts for venting the flue gases, but identifies “special venting systems”, the following requirements shall be satisfied by the manufacturer:
The referenced “special venting systems” instructions shall be included with the appliance or equipment installation instructions and;
The “special venting systems” shall be Product Approved by the Board, and the instructions for that system shall include a parts list and detailed installation instructions.
A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all vent ing instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation.
PAGE 5
SPECIFICATIONS
32mm
140mm
241mm
213mm
70mm
952mm
911mm
797mm
619mm
191mm
387mm
2
1
2
1
"
4
1
1
"
4
3
2
TOP
FRONT
RIGHT
LEFT
8
7
2
1
708mm
813mm
"
8
3
8
"37
"9
"5
"7
"27
"
4
1
15
"
8
3
24
32"
"
8
3
31
"
8
7
35
140mm
2
1
"5
2
1
FIREPLACE DIMENSIONS
FIREPLACE
DIMENSIONS
WARNING: Top stand-off brackets must be attached to fireplace. Do not remove. Stand-off brackets are not load bearing. Non-combustible zone: Stand-offs provide 5-1/2” (140mm) minimum clearance to header. Use only non-combustible material in this area for entire width of fireplace. Do not use wood, sheetrock etc. in this zone. Other clearances apply. All clearances
must be maintained.
DESCRIPTION Height Width Back Width Depth Opening
INCHES
MILLIMETERS
32 35-7/8 27-7/8 15-1/4 31-3/8 24-3/8 5-1/2 7-1/2
813 911 708 387 797 619 140 191
Width
Glass Frame
Height
Stand-off
Height
Back to vent
center
Figure 6a
CLEARANCES
Top of unit face to framing 5-1/2” (140mm)
From unit left & right sides & back 1/4” (6mm)
To flooring 0” (0mm)
Unit top to ceiling 31” (787mm)
Unit side to adjacent sidewall 1-1/2” (38mm)
Unit front to combustibles 36” (914mm)
Top of unit to 3/4” (19mm) trim 10” (254mm)
Mantel 4” (102mm) deep from top of fireplace 16” (406mm)
PAGE 6
SPECIFICATIONS
#DEL-36 COMPONENTS LIST
PART NUMBER DESCRIPTION
DEL-600-IPI Control Board Assembly
700-203 Manual Gas Shut-off Valve
DEL-135 Burner Assembly
DEL-LKT Light Kit
DSL-057T Glass Frame Assembly
OCK-A54L-I-DEL-PSE LP Conversion Kit
700-208 Remote Control
600-002 Double Receptacle Assembly
942-085 5” Restrictor Plate
DEL-HHS Horizontal Vent Heat Shield
ADDITIONAL COMPONENTS REQUIRED
Vent System: Approved venting listed on page 15 of this installation manual.
Glass Media: Various colors available. See Dealer for details.
Contemporary Frame: Various styles and finishes available. See Dealer for details.
INSTALLATION OVERVIEW
NOTE: The qualified installer should follow the procedure best suited for the installation.
1. Frame an opening for fireplace, allowing for vent installation and type of installation (corner or flat wall application).
2. If masonry (optional) is used, prepare foundation for the masonry load. A lintel is required to support the added weight above fireplace.
3. Attach stand-off brackets and nailing flanges to fireplace.
4. Insert fireplace into framing.
5. Install hearth (if applicable).
6. Complete gas line installation.
7. Complete electrical hook-up. Install any standard or optional electrical components at this time.
8. Complete venting installation.
9. Secure fireplace to flooring through holes in outer box bottom and to framing with nailing flanges. Verify all clearances at this point.
10. Install facing material, mantel or cabinetry, allowing room for optional full face doors, if applicable.
11. Install glass media (required), and any optional burn media.
12. Install contemporary frame (required).
13. Verify proper operation of fireplace and all components.
PLACEMENT CLEARANCE REQUIREMENTS
This fireplace must be installed on a level surface capable of supporting fireplace and venting.
Fireplace must be placed directly on wood or non-combustible surface (not linoleum or carpet) extending entire depth and width of fireplace.
Due to high surface temperatures, fireplace should be located out of traffic and away from furniture and draperies.
This fireplace may be installed in a bedroom.
Please be aware of the large amount of heat this fireplace will produce when determining a location.
PAGE 7
FIREPLACE PREPARATION
STAND-OFF / STAND-OFF HEAT SHIELD ASSEMBLY & INSTALLATION
WARNING: Top stand-off brackets must be formed and attached prior to positioning fireplace into framed opening.
Stand-offs provide 5-1/2” (140mm) minimum clearance to header. Use only non-combustible material in this area for entire
width of fireplace. Do not use wood, sheetrock, etc. in this zone. Other clearances apply. All clearances must be maintained.
Stand-off brackets are not load bearing.
Top stand-off brackets and stand-off heat shield are attached to fireplace top in a flat state for shipping.
1. Remove and save (4) screws securing stand-off heat shield and stand-off brackets.
2. Form each stand-off bracket as shown.
3. Re-attach stand-off brackets to fireplace using screws previously removed along with (4) screws provided in fireplace components packet.
4. Form stand-off heat shield and attach to stand-off brackets with (2) screws provided in fireplace components packet.
(Flange on stand-off heat shield faces „up‟ and to back of fireplace).
STAND-OFF BRACKETS
AS SHIPPED
ATTACH BOTH STAND-OFF BRACKETS BY ALIGNING WITH HOLES IN FIREPLACE TOP. SECURE WITH (4) SCREWS.
REMOVE SCREWS SECURING
STAND-OFF BRACKETS
BEND STAND-OFF AT
PERFORATIONS
FORMED STAND-OFF
ATTACH STAND-OFF HEAT SHIELD BY ALIGNING WITH HOLES IN STAND-OFF BRACKETS. SECURE WITH (4) SCREWS.
Figure 8a
PAGE 8
FIREPLACE PREPARATION
NAILING FLANGE ASSEMBLY & INSTALLATION
1. Remove (4) nailing flanges from fireplace sides.
2. With the 1/4” (6mm) stand-offs on nailing flanges facing away from fireplace, align nailing flange with holes on outside corners of fireplace. Secure with screws (provided in components packet) through slots in nailing flanges.
3. Bend perforation on nailing flange until parallel with fireplace face. Do not bend toward fireplace face.
4. Position framing stud against 1/4” (6mm) stand-off (located on backside of nailing flange). Secure with nails or screws.
NOTE: Depending on facing material, tabs can be adjusted forward or back wards up to 1/2” (13mm).
CAUTION: Never permanently remove these assemblies from fireplace - they must be secured in place regardless of finish material used.
When installed, nailing flanges provide the minimum 1/4” (6mm) clearance from fireplace sides.
1/4” (6mm)
CLEARANCE
Figure 9a
AS SHIPPED
NAILING FLANGES
INSTALLED
1/4” (6mm)
CLEARANCE
FRONT VIEW
NAILING FLANGE
FRAMING STUD
TOP VIEW
STAND-OFF
FRAMING STUD
NAILING FLANGE
PAGE 9
FRAMING
WALL ENCLOSURE ROUGH OPENING
IMPORTANT: Framing dimensions should allow for wall covering thickness and fireplace facing materials. If using a hearth, adjust rough opening size as necessary to maintain at least minimum clearance requirements.
IMPORTANT: Non-combustible facing material may be applied over (but not directly to) fireplace face. This will prevent facing material from falling off due to heat expansion. Do not obstruct the flow of ventilation air.
MINIMUM FINISHED OPENING DIMENSIONS
(APPLIES TO BOTH HORIZONTAL AND VERTICAL VENTING TERMINATIONS)
37-1/2”(952 mm) High x 36-3/8” (924 mm) Wide x 15-3/4” (400mm) Deep.
1/4” (6 mm) clearance at back and sides of fireplace must be maintained.
NOTE: Provide adequate clearance in front of fireplace to access components.
WARNING: DO NOT OBSTRUCT UPPER AND LOWER GRILL OPENINGS. ROOM AIR ENTERS THROUGH LOWER PASSAGE, IS HEATED AND EXITS THROUGH UPPER PASSAGE. BLOCKING THESE PASSAGES MAY RESULT IN OVERHEATING, CREATING A POTENTIALLY HAZARDOUS SITUATION.
Figure 10a
12-1/2” (318mm) H x 10-7/8” (277mm) W opening
(required for horizontal terminations)
37-1/2”
(952mm)
36-3/8”
(924mm)
PAGE 10
FRAMING
Determine exact position of your fireplace, including hearth height, width, and depth, (if applicable). If possible, place fireplace in such a manner that vent termination will be placed between two studs, eliminating the need for additional framing.
If masonry is to be used (optional), prepare necessary foundation for the masonry load. When masonry construction is being used, a lintel must be used over top of fireplace to support the added weight.
Build hearth to desired size and height. If a hearth extension is desired, combustible material may be used.
NOTE: Consider height of hearth finish material (stone, brick, etc.) when building fireplace platform. The bottom of fireplace must be level with finished hearth to allow for proper fit of contemporary frames.
WARNING: Install fireplace on hard metal or wood surface extending the full width and depth of fireplace. Minimum platform size: 37-7/8” (911mm) wide x 15-1/4” (387mm) deep.
FIRE HAZARD: Do NOT install directly on carpeting, vinyl, or any combustible material other than wood.
IMPORTANT: Vent cap location must be in compliance with guidelines on page #23 of this manual.
WARNING: DO NOT RECESS VENT CAP INTO WALL OR SIDING.
VERTICAL TERMINATIONS
Follow vent pipe manufacturer‟s installation instructions for vertical terminations. A minimum 1” (25mm) clearance on all sides of vertical vent pipe must be maintained.
NOTE: The included Horizontal Vent Heat Shield is not used for vertical configurations.
HORIZONTAL TERMINATIONS
Frame a 12-1/2” (318mm) high (H) x 10-7/8” (276mm) wide (W) opening on exterior wall for chimney termination. This opening size includes required
3” (76mm) top clearance and 1” (25mm) sides and bottom clearances for
approved rigid vent systems and Kozy Heat #800 series flexible vent system.
MINIMUM HORIZONTAL FRAMING DIMENSIONS
VENT PIPE TOP (A) FRAMED OPENING TOP (B)
RIGID PIPE 42-1/8” (1070mm) 45-1/8” (1146mm)
FLEX PIPE 49” (1245mm) 52” (1321mm)
W
H
B
A
CAUTION: Cold air transfer area. The surrounding fireplace chase must comply with all clearances as outlined in this manual and be constructed in compliance with local building codes. Outside walls should be insulated to prevent cold air from entering room.
CAUTION: Due to high temperatures, this fireplace should be located out of traffic areas and away from furniture and draperies.
Figure 11a
PAGE 11
10"
254mm
22"
559mm
16"
406mm
3/4"
19mm
4"
102mm
14"
356mm
TYPICAL INSTALLATION OPTIONS
IMPORTANT: Kozy Heat wall thimble pass-thru (#800-WPT or #800-WPT2) must be used on all horizontal vent runs. Follow instructions on page 16of this installation manual.
IMPORTANT: The horizontal heat shield included with this fireplace must be installed when using a 90-degree elbow directly off top of unit to horizontally position vent system.
IMPORTANT: Horizontal vent heat shield not shown in illustrations below for clarity purposes only.
CORNER INSTALLATION
1/4” (6mm)
29-78”
(759mm)
59-3/4” (1517mm)
Figure 12a
42-1/2”
(1073mm)
HORIZONTAL INSTALLATION
15-1/2”
(394mm)
36-3/8”(924mm)
VERTICAL INSTALLATION
15-1/2”
(394mm)
36-3/8”(924mm)
1/4” (6mm)
1/4” (6mm)
MANTEL REQUIREMENTS
WARNING: Non-combustible zone: No combustible materials allowed on top of fireplace within shaded area for entire width and depth of fireplace with the exception of the header. Backside of header must be no more than 2-1/4” (57mm) from front of fireplace.
Figure 12b
Horizontal vent heat shield
Clearance to mantel legs or wall projections
(acceptable on both sides of opening).
PAGE 12
GLASS FRAME / CONTEMPORARY FRAME
WARNING: DO NOT OPERATE THIS FIREPLACE WITH THE GLASS FRONT REM OVED, CRACKED OR BROKEN. REPLACEMENT OF THE GLASS SHOULD BE DONE BY A LICENSED OR QUALIFIED SERVICE PERSON.
CAUTION: TO PREVENT GLASS FRAME ASSEMBLY FROM FALLING FROM FIREPLACE AND BECOMING DAMAGED, FOLLOW THESE INSTRUCTIONS EXACTLY WHEN REMOVING AND INSTALLING GLASS FRAME ASSEMBLY.
REMOVE GLASS FRAME ASSEMBLY
1. Locate spring-loaded handles securing glass frame assembly at top & bottom of firebox.
2. Pull bottom handles out and down to release assembly bottom.
3. Pull top handles out and up to release assembly top.
4. Remove glass frame assembly from fireplace.
INSTALL GLASS FRAME ASSEMBLY
1. Place glass frame assembly onto fireplace front.
2. Pull top handles out and down to secure assembly top.
3. Pull bottom handles out and up to secure assembly bottom.
CONTEMPORARY FRAME (sold separately)
Figure 13a
To Install: Align tabs on back of frame with slots on fireplace, set into position.
To Remove: Lift frame up and out of slots.
OPTIONAL FAN KIT INSTALLATION
INSTALLATION OF THIS FAN SHOULD BE DONE ONLY BY A QUALIFIED INSTALLER
WARNING: MAKE SURE HOUSEHOLD BREAKER IS SHUT OFF PRIOR TO WORKING ON ANY ELECTRICAL LINES.
WARNING: THIS APPLIANCE IS EQUIPPED WITH A THREE-PRONG (GROUNDING) PLUG FOR PROTECTION AGAINST SHOCK HAZARD AND SHOULD BE PLUGGED DIRECTLY INTO A PROPERLY GROUNDED THREE-PRONG RECEPTACLE. DO NOT CUT OR
REMOVE GROUNDING PRONG FROM THIS PLUG.
IMPORTANT: If installing a fan, it is easier to complete before the control board is connected to the gas line.
NOTE: This appliance must be electrically grounded and connected in accordance with local codes, or in the absence of local c odes, with the National Electrical Code, ANSI/NFPA 70 Current Edition, or the Canadian electrical Code CSA C22.1.
The following components must be removed from fireplace before installing this fan. Refer to corresponding pages in this installation manual for assistance if necessary: Face frame, Glass frame assembly.
1. Insert fan through right side of lower grill opening , push to back wall.
2. Plug cord into receptacle marked FAN on extension module.
3. Re-install glass frame assembly and face frame.
Figure 13a
PAGE 13
GAS LINE CONNECTION
GAS CONVERSION
This fireplace is manufactured for use with Natural Gas. An LP conversion kit, is included with this fireplace. Follow instructions included with conversion kit if converting to LP gas.
ATTENTION: The conversion shall be carried out in accordance with the requirements of the provincial authorities having jurisdiction and in accordance with the requirements of the ANSI Z223.1 installation code.
CAUTION: Installation of the gas line must only be done by a qualified person in accordance with local building codes, if any. If not, follow ANSI 223.1.
Commonwealth of Massachusetts: Installation must be done by a licensed plumber of gas fitter.
NOTE: A listed (and Commonwealth of Massachusetts approved) 12” (305mm) T- handle manual shut-off valve and flexible gas connector (included) are connected to the 1/2” (13mm) control valve inlet. If substituting for these components, please consult local codes for compliance.
gas line should be run to the point of connection where the shut-off valve and flexible gas line will connect.
NOTE: The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at pressures in excess of ½ psi. (3.5kPa)
NOTE: The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas line at test pressures equal to or less than ½ psi (3.5 kPa).
NOTE: For high altitude installations, consult the local gas distributor or the authority having jurisdiction for proper rating methods.
NOTE: This fireplace is equipped with a 3/8”(10mm) x 18” (457mm) long flexible gas connector and manual shut-off valve. The
IMPORTANT: The efficiency rating of this appliance is a product of thermal efficiency rating determined under continuous operating conditions and was determined independently of any installed system.
NATURAL GAS LP GAS
MINIMUM INLET GAS PRESSURE 5” WC (1.25 kPa) (7” WC (1.74 kPa) recommended) 11” WC (2.74 kPa) (recommended)
MAXIMUM INLET GAS PRESSURE 10.5” WC (2.62 kPa) 13” WC (3.24 kPa)
MANIFOLD PRESSURE (HI) 3.5 (.87 kPa) 10.0 (2.49 kPa)
MANIFOLD PRESSURE (LO) 0.6 (.15 kPa) 1.5 (.37 kPa)
ORIFICE SIZE #42 #54
INPUT BTU/hr. (kW) 26,000 BTU/hr (7.62 kW) 25,500 BTU/hr (7.47 kW)
MINIMUM INPUT BTU/hr. (kW) 10,000 BTU/hr (2.93 kW) 8,000 BTU/hr (2.35 kW)
See page 37 for proper method for testing appliance inlet pressure.