Kozi DV1-FS series Owner's Manual

Owner’s Manual
Direct Vent Freestanding Gas Stove
*Installation * Operation * Service * Parts *
Manufactured By: APR Industries Ltd. 1354 Waverley Street, Winnipeg, Manitoba, Canada, R3T 0P5
Save This Manual For Future Reference
WARNING: If the information in these instructions are
not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance
WHAT TO DO IF YOU SMELL GAS
o Do not try to light any appliance. o Do not touch any electrical switch; do not
use any phone in your building.
o Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s instructions.
o If you cannot reach your gas supplier, call
the fire department.
Installation and service must be performed by a qualified installer, service agency or the gas supplier
This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes.
This appliance is only for use with the types of gas indicated on the rating plate. A conversion kit is available for the appliance.
Printed in Canada Revision July 2006
KOZI DIRECT VENT GAS STOVE
Dear New Owner:
Thank you and Congratulations for the purchase of this KOZI Hearth Product. This Direct Vent Gas appliance was manufactured by APR Industries Ltd. with the goal of producing a quality hearth product for your comfort and enjoyment.
All variations of the appliance in this series have been approved by Warnock Hersey for performance, safety, and efficiency. Also, we proudly display our KOZI logo on these units, which provides you with additional assurance of trouble free, economical and enjoyable operation.
Please be a responsible owner of this appliance and take a few moments to familiarise yourself with the contents of this manual. Safe installation and proper operation instructions may be found within the following pages. Check all local building and fire codes before installing your new appliance. When a qualified installer, service agent or gas supplier has completed the installation, have the unit checked by a local inspector to guarantee safe and proper operation. Disregarding inspection and proper code requirements may jeopardise your homeowner's insurance. Be sure to contact your insurance agent, as many carriers require notification of this type of appliance installation.
We have taken every effort in providing you with complete and easy to follow installation, operation and service instructions. If you should have any further questions or concerns that have not been covered by this manual, please contact your KOZI dealer.
Figure: 1 - Overall Dimensions of the KOZI Direct Vent Freestanding Gas Stove.
2
KOZI DIRECT VENT GAS STOVE
TABLE OF CONTENTS
General Information
Customer Greeting 2
Safety Certification Information 4 Typical Venting Configuration 5 Installation Instructions 6
Venting 9 Installation Precautions 10 Venting Configurations – Horizontal Termination 12 Venting Configurations Vertical Termination 13 Examples of Venting Configurations 13 Planning Your Installation 14 Simpson Dura-Vent Direct Vent Parts Listing 15 Vent Restrictors 16 Horizontal Termination Installations 16 Vertical Termination Installations 18 Cathedral Ceiling Installations 20 Connecting The Gas Supply 21 Log Installation And Placement 22 Door Installation And Latch Adjustment 23 Adjusting The Primary Air For Combustion 24
Operating Instructions 25 Lighting Procedure 25
Shutdown Instructions 26 Maintenance And Service Instructions 27
General Venting Maintenance 28 Log Replacement 29 Gold Plated Trim 29 Door Gasket Replacement 29 Glass Replacement 29 Glass Door Replacement 30 Electrical Schematic 30 Fuel Conversion 31 General Layout 33 KOZI DV1 Parts Listing 33 Warranty Information 35
Overall Unit Dimensions 2
General Information 7
Locating Your KOZI Gas Stove 8
Clearances to Combustible Surfaces 8
Combustion And Ventilation Air 9
3
KOZI DIRECT VENT GAS STOVE
SAFETY CERTIFICATION INFORMATION
Provided below is a copy of the KOZI Direct Vent Freestanding Gas Stove safety label. The safety label is located on the inside surface of the right side door.
Note: Due to constant development, KOZI units and technologies are consistently being upgraded. Please ensure that the label contained on this page is the same as the label on your gas appliance. If there are any discrepancies, the label presented below is correct.
4
KOZI DIRECT VENT GAS STOVE
TYPICAL VENTING CONFIGURATIONS
In order to achieve proper and safe installation and operation, please ensure that the following list of components is purchased prior to the installation of your new KOZI Direct Vent Freestanding Gas Stove. In the event of absent or damaged components, contact your KOZI dealer.
Note: The following list only covers the minimum parts required for the proper installation. Other parts may be required for your particular installation. (see page 15 for an additional listing of available parts.)
Figure: 2 - Typical venting components.
5
KOZI DIRECT VENT GAS STOVE
INSTALLATION INSTRUCTIONS
This Stove Is A Gas-Fired Direct Vent Space Heater. Do Not Burn Wood Or
Any Other Combustible Materials In This Appliance.
Adults And Children Should Be Made Aware Of The Potential Hazards And
Dangers Involved With This Stove. This Appliance Is Capable Of High Surface Temperatures. To Avoid Burns Or Ignition Of Clothing, Stay Away From The Unit While In Operation And Supervise Younger Children When They Are Occupying The Same Room As The Stove.
Due To The High Temperatures, The Appliance Should Be Located Out Of
Traffic And Away From Furniture And Draperies.
Clothing Or Other Combustible Materials Should Not Be Placed On Or Near
Any Surface Of This Appliance.
Any And All Equipment Removed From This Unit For Maintenance Or
Servicing Must Be Reinstalled Prior To Further Operation Of This Unit.
WARNING:
It Is Extremely Important That The Control Compartment, Blower Area And
Venting System Be Kept Clean. The Stove And Its Venting System Should Be Inspected Annually By Qualified Personnel. The Stove Area Must Also Be Kept Clean Of Flammable Materials, Vapors And Liquids.
Under No Circumstances Should This Unit Be Modified Or Altered
Whatsoever.
This Stove Can And Must Only Be Attached To A Dedicated Venting Flue
Pipe. Under No Circumstances Can More Than One Appliance Share The Same Flue Pipe Or Venting.
Do Not use This Appliance If Any Part Has Been under Water. Immediately
Call A Qualified Service Technician To Inspect The Appliance And To Replace Any Part Of The Control System And Any Gas Control Which Ahs Been Under Water.
Do Not Operate This Appliance With The Glass Door Removed, Cracked Or
Broken. Replacement Of The Glass Or Any Other Door Components Should Be Attempted Only By A Qualified Technician.
Avoid Slamming And Striking The Glass Door.
A Manufactured Home (USA Only) Or Mobile Home OEM Installation Must
Conform With The Manufactured Home Construction And Safety Standard, Title 24 CFR, Part 3280, Or, When Such A Standard Is Not Applicable, The Standard for Manufactured home Installations, ANSI/NCSBCS A225.1, or Standard For Gas Equipped Recreational Vehicles And Mobile Housing, CSA
6
KOZI DIRECT VENT GAS STOVE
GENERAL INFORMATION:
Note: Read these instructions carefully and completely. Failure to follow
them could cause malfunction or damage to the appliance, property
damage, personal injury or fatality. Failure to comply with these
instructions could result in loss of insurance coverage and warranty.
This appliance must be installed on a flat, solid, continuous surface. This may be on the
floor or the raised surface of a platform to emphasise the visual enjoyment.
The KOZI Direct Vent Freestanding Gas Stove has been approved for the installations
displayed in the following diagram, Fig. 3. This unit has also been approved for installations employing millivolt thermostats for heat regulation. Installations in Mobile Homes have been approved as long as the appliance is securely bolted to the frame.
The installation must conform with local codes or, in the absence of local codes, with
the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane Installation Code, CSA B149.1. A manufactured home (USA only) or mobile home OEM installation must conform with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, or, when such a standard is not applicable, the Standard for Manufactured Home installations, ANSI/NCSBCS A225.1, or Standard for Gas Equipped Recreational Vehicles and Mobile Housing, CSA Z240.4.
The appliance, when installed, must be electrically grounded in accordance with local
codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1. This appliance is equipped with a three-prong (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong form this plug.
The product should be inspected for shipping damage prior to installation and serviced
annually thereafter by a qualified technician.
This appliance must be connected to the specified vent and termination cap to the
outside of the building. Never vent into another room or inside a building. Ensure that the vent is properly jointed as per the instruction on page 17.
To prevent injury or bodily harm, do not allow anyone who is unfamiliar with this
appliance operate it without supervision.
The efficiency rating of this appliance is a product thermal efficiency rating determined
under continuous operating conditions and was determined independently of any installed system.
7
KOZI DIRECT VENT GAS STOVE
The appliance and it’s appliance main gas valve must be disconnected from the gas
supply piping system during any pressure testing of that system at test pressures in excess of ½ psi (3.5 kPa)
The appliance must be isolated from the gas supply piping system by closing it’s
equipment shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than ½ psi (kPa).
Installation and repair should be done by a qualified service person. The appliance
should be inspected before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, et cetera. It is imperative that control compartments, burners and circulating air passageways of the appliance be kept clean.
8
KOZI DIRECT VENT GAS STOVE
LOCATING YOUR KOZI GAS STOVE
All clearances listed below and within the following section must be satisfied when selecting a location for your appliance. Maintaining these clearances will ensure that there will be adequate access for servicing and regular maintenance.
This unit has been approved for the following locations in your dwelling:
A. Angled Across Corner
B. Flush Against Wall And Alcove
C. Flat Against Wall And Corner
D. Flat Against Wall
Figure: 3 - Various Approved Installation Configurations
E. Island Installation F. Dividing Room G. Two Elbow Venting
CLEARANCES TO COMBUSTIBLE SURFACES
The list of clearances provided are MINIMUM distances only. Measure the clearance area to both the appliance and the chimney connector. The greater measurement is correct if the two clearances do not coincide.
For example, if the unit is situated as indicated in Fig. 3 but the connector is too close, move the unit until the correct clearance is achieved.
This appliance may only be installed with the clearances provided as shown in Figs. 3 & 4. DO NOT combine clearances from one type of installation with another to achieve closer clearances.
9
KOZI DIRECT VENT GAS STOVE
Use the minimum clearances provided below with the appropriate dimension shown in Fig. 2, also below.
A. Side Wall To Unit 10” (254 mm) B. Back Wall To Unit 1” (25 mm) C. Back Wall To Flue Centreline 5.5” (140 mm) D. Side Wall To Flue Centreline 21.5” (546 mm) E. Side Wall To Unit 1” (25 mm) F. Side Wall To Flue Centreline 9” (228 mm)
Minimum ceiling clearance height is 38” (965 mm) from the top of the unit.
Figure: 4 - Minimum Clearances Diagram.
COMBUSTION AND VENTILATION AIR
Note: The fresh combustion air required by this gas stove is drawn from
outside the building through the outer flue. Therefore, there is no need for extra provisions to increase the air inside the room containing the appliance.
VENTING
The instructions contained within the pages of this manual pertain to the installation of Simpson Dura-Vent Direct Vent System model DV-GS. This venting system, in combination with the KOZI Direct Vent Freestanding Gas Stove, DV1, have been tested and listed as a direct vent space heater by Warnock Hersey.
10
KOZI DIRECT VENT GAS STOVE
Carefully Read All Instructions To Completion Prior To Installation. Failure To Follow These Instructions May Result In Safety Hazards, As Well As Voiding The Warranty. Ensure That All Venting And Clearances To Combustible Requirements Have Been Satisfied. Consult Your Local Building Codes Before You Begin The Installation.
Note: The location of the termination cap must satisfy the requirements set forth by the Exterior Vent Terminal Locations found in Fig. 3, on the next page.
IMPORTANT:
INSTALLATION PRECAUTIONS:
The Simpson Dura-Vent Direct Vent System is an engineered product that has been Designed and thoroughly tested for use with the KOZI DV1. The Simpson Dura-Vent warranty will be voided and serious fire, health and safety hazards may result from any of the following situations:
1. The utilization of any damaged Direct Vent component.
2. Unauthorized modification or alteration of any kind to the Direct Vent System.
3. Unauthorized installation of any Direct Vent System components not manufactured or approved by Simpson Dura-Vent and or APR Industries Ltd.
4. Installation other than as instructed in this manual or by Simpson Dura-Vent.
Always maintain required clearances to nearby combustibles to aid in the
prevention of fire and safety hazards. Do not fill air spaces with insulation or any
The minimum clearance requirements between the outer wall of the vent pipe and nearby combustible surfaces is 1¼”. Ensure that the vent terminal clearance requirements from decks, windows, soffits, gas regulators, air supply inlets and public walkways have been satisfied completely. The diagram on the following page, Fig. 5, demonstrates these clearance requirements, or alternately refer to your local building codes.
WARNING
other combustible material.
11