Korenix JetNet 3008 v3, JetNet 3008f v3 User Manual

JetNet 3008 v3
JetNet 3008f v3
Industrial 8-port Ethernet Switch
Version:1.1 Date: 26-Jun-2013
Content
1. Introduction ................................................................. 1
1-1. Features ...................................................................... 2
1-2. Packing List ................................................................. 2
2. Hardware Description .................................................. 3
2.1. Dimensions ........................................................... 3
2-2 Front Panel ........................................................... 4
2-3. Bottom View .......................................................... 4
2-4. LED Indicators ...................................................... 5
2-5. Ports ..................................................................... 6
3. Mounting Installation ................................................... 7
DIN-Rail Mounting ............................................................... 7
4. Hardware Installation .................................................. 9
4-1. Wiring the DC Power Inputs ................................ 10
4-2. Wiring the Alarm Relay ....................................... 11
4-3. Wiring Earth Grounding ....................................... 12
4-4. Enabled the Event Alarm Function ...................... 12
4-5. Cabling ................................................................ 14
4-6. System Power-On and Testing ........................... 15
5. Packet forwarding and filtering ability ........................ 19
5-1. Broadcast Control ............................................... 19
5-2. Quality of Service ................................................ 19
6. Trouble shooting ....................................................... 22
Federal Communications Commission (FCC) Statement
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his expense.
The user is cautioned that changes and modifications made to the equipment without
approval of the manufacturer could void the user's authority to operate this equipment.
JetNet 3008 v3 / JetNet 3008f v3 Users Manual
1
1. Introduction
The JetNet 3008V3/ 3008f V3 is an 8-port Fast Ethernet switch designed with enhanced design specifications, including wider operating temperature and power input range to best fit in heavy industrial field applications. It is equipped with 2.0Gbps High performance switching engine with packet forwarding and filtering mechanism to fulfill higher performance industrial data communication requirements in field site deployments. The graceful packet forwarding ability enables the JetNet 3008f V3 to handle from 64 to 1522 bytes packet sizes into 2 forwarding priority queues which is compliant with IEEE 802.1p Class of Service for providing best data forwarding performance. In addition, to ensure best network performance, both broadcast storm filtering and flow control functions can ensure your data traffic delivery to destination without traffic congestion. The combination of enhanced network features and rugged specs make the JetNet 3008 V3 /JetNet 3008f V3 become your best entry-level networking solution in industrial deployments.
Reliable Power System Design
In order to operate under harsh environment of industrial sites, JetNet 3008 V3 series are designed with redundant wide power input 10~60VDC range as well as auto polarity reverse function to ensure the switch’s capability of transmitting data under poor DC power sourcing.
Brilliant Electromagnetic Interference Immunity
In industrial applications with widespread electromagnetic interference, such as the automation control and high power motor operating environments, the switchs electromagnetic immunity ability will affect the quality of data transfer. The JetNet 3008 V3, compliant with the electromagnetic interference requirements for Heavy Industrial applications, provides a high level of electromagnetic susceptibility exceeding the IEC/EN 61000-6-2 standard with distinguished electrical slow transient (Surge), radio-frequency electromagnetic field (RS), Electrical Fast Transient (EFT) protections. Equipped with a rugged aluminum case with IP31 grade protection and high thermal conductivity design, it is capable of resisting -25~70 (JetNet 3008), -10~70 (JetNet 3008f) and -40~75(JetNet 3008-w/ JetNet 3008f-w) wide temperature ranges while providing reliable connectivity under harsh industrial environments.
2
This session will introduce following information of JetNet 3008 for your reference.
1. Features
2. Packing list
1-1. Features
8 10/100TX ports – JetNet 3008  6 10/100TX, plus 2 100FX in Multi-mode or Single-mode – JetNet
3008f
Compact size with full power redundancy  2.0Gbps Switch Fabric with excellent data exchange performance  QoS for packet forwarding precedence  Broadcast storm packet filtering  Port and power event alarm  Aluminum metal case with IP31 grade protection  DIN rail installation  Dual power input DC10~60V  Support 1.5KV Hi-Pot isolation protection  Operating temperature: -25~70oC (JetNet 3008 V3) and -40~75oC
(JetNet 3008-w V3), -10~70oC (JetNet 3008f V3) and -40~75oC (JetNet 3008f-w V3)
1-2. Packing List
JetNet 3008 v3/JetNet 3008f v3 Industrial 8-port Fast Ethernet Switch is
packaged with the following items:
JetNet 3008 or JetNet 3008f
Quick Installation Guide
Contact your sales representative if any item is missing or damaged.
JetNet3008 v3 JetNet 3008f v3
Quick Installation Guide
3
2. Hardware Description
This session will introduce the hardware information as following:
2-1. dimensions
2-2. Front Panel
2-3. Bottom View
2-4. LEDs of system and port
2-5. Connectors
2.1. Dimensions
JetNet 3008 / JetNet 3008f 8-port Industrial Fast Ethernet Rail Switch
dimensions are 120 mm (H) x 55 mm (W) x 108 mm (D), detail
mechanical design drawings are attached as following:
4
2-2 Front Panel
The Front Panel of the JetNet 3008/JetNet 3008f Industrial 8-port Fast
Ethernet Switch is shown in Figure A.
Figure A. Front Panel of the JetNet 3008 / JetNet 3008f.
2-3. Bottom View
The bottom view of the JetNet 3008/JetNet 3008f Industrial 8-port
Ethernet Switch consists of one 6-pin removable terminal block connector
for two DC power inputs and event alarm output. There is one 9-pin DIP
SWITCH on the bottom for alarm control of port or power event selection.
5
Figure B. Bottom view of the JetNet 3008/ JetNet 3008f
2-4. LED Indicators
There are some system diagnostic LEDs and Ethernet Port LEDs located
on the front panel of JetNet3008 / JetNet 3008f Industrial 8-port Ethernet
Switch. These LED indicators provide administrators with real-time system
status. The table-1 gives the descriptions of the function of each LED
indicator.
LED
Status
Description
Power is on.
No power is being supplied.
Power is on.
No power is being supplied.
Port link down or power failure event occurred.
No event.
A network device is detected and link up.
The port is transmitting or receiving packets from the TX device.
A network device is detected and link on 100Mbps.
A network device is detected and link on 10Mbps.
6
The port is operating in full-duplex mode.
The port is transmitting or receiving packets from the TX device.
Table 1
2-5. Ports
RJ-45 ports (Auto MDI/MDIX): JetNet 3008 has eight 10/100 Mbps
auto-sensing RJ-45 ports for 10Base-T or 100Base-TX device connection
and JetNet 3008f has six 10/100Mbps RJ-45 ports and two 100Mbps fiber
ports for multi-mode or single-mode fiber cable in SC type connector. The
RJ-45 ports will auto-detect 10Base-T and 100Base-TX connections. Auto
MDI/MDIX function allows users to connect another switch or workstation
without changing straight through or crossover cabling. See Figure C and
C-1 for the schematic diagram of straight through and crossover cabling.
Figure C Straight Through Cabling Schematic Figure C-1 Cross Over Cabling
Schematic
All RJ-45 ports of JetNet 3008/ JetNet 3008f support auto-MDI/MDI-X
function. When you use an Ethernet cable to connect other devices, such
as computers, switches or hubs, pin 1, 2, 3, and 6 of the 8-pin RJ45
connector are used to communicate with the connected devices. Pin1, 2,
3, and 6s signals are converted by the MDI-X function, as shown in Table
-2.
Pin MDI-X
Signals
MDI Signals
Loading...
+ 20 hidden pages