Kooltronic KNP60FLV Operation Manual

Keep This Manual
With Fan
GUARDIAN SERIES
FILTER FAN
OPERATOR'S MANUAL
CAUTION
BEFORE INSTALLING AND
USING THIS FILTER FAN, IT IS
BE READ AND UNDERSTOOD
THOROUGHLY
Guardian Series
KNP60FL
NEMA 4 or 4X Filter Fans
READ AND SAVE THESE INSTRUCTIONS
2
TABLE OF CONTENTS
Page
I. Introduction 2
II. Cautions and Warnings 3
III. Incoming Inspection 4
IV. Product Handling 4
V. Product Identification and Nameplate 4
VI. Installation Instructions 5
VII. Drawings and Dimensions 5
VIII. Specific Model Data 6
Technical Data
Standard Features
Replacement Filters
Optional Filter-Hood Assemblies
IX. Packing Procedure for Warranty Return 6
X. Maintenance 7
XI. Warranty 8
I. Introduction
This Manual provides you with the necessary general information for properly installing and operating Guardian Series Filter Fans. Unit specific technical data and mounting instructions are presented later in the Manual.
3
II. Cautions and Warnings
CAUTION
Do not operate fan without fanguard in place.
CAUTION
The risk of fire, electric shock or injury exists when cleaning or performing maintenance on these
units. Disconnect this fan from the power supply before servicing.
WARNING
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK:
Do Not Use This Fan With Any Solid-State Speed Control Device.
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY, OBSERVE THE FOLLOWING: Use this unit only in the manner intended by Kooltronic. If you have questions, contact Kooltronic. Before servicing or cleaning this unit, switch power off at the service panel and lock service panel
to prevent power from being switched on accidentally. If service panel cannot be locked, securely
fasten a prominent warning device, such as a tag, to the panel.
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY, OBSERVE THE FOLLOWING:
Installation work and electrical wiring must be done by qualified person(s) in accordance with all
applicable codes and standards, including fire-rated construction. When cutting or drilling into a
wall or ceiling, do not damage electrical wiring and other hidden utilities.
CAUTION
For general ventilating use only. Do not use these fans to exhaust hazardous or explosive material
and vapors.
CAUTION
NOT ALL SYSTEMS ARE SUITABLE FOR UTILIZING OUTSIDE AIR
To protect sensitive components against condensation an enclosure heater or closed-loop cooling is recommended. To protect sensitive components against corrosive elements closed-loop cooling
is recommended.
4
III. Incoming Inspection
Guardian Series Filter Fans are designed, built, and packaged to withstand the shock and vibration associated with shipment by common carriers. Occasionally improper handling during shipping causes damage. Therefore, a thorough inspection should be performed upon receipt of all shipments. Any carton tears, dents, scratches, or loose articles should be noted on the Freight Bill. Cartons should be opened promptly and the
units inspected for CONCEALED DAMAGE
.
An immediate claim MUST be filed with the freight carrier and an inspection requested. Retain all packing materials. Kooltronic cannot assume responsibility for Consignee's failure to file a timely freight claim.
IV. Product Handling
Do not attempt to operate your Filter Fan until you read and thoroughly understand this Manual.
Before operating this unit, all electrical wiring must be checked to assure the proper connections.
Use only on GFCI Protected Receptacles.
V. Product Identification and Nameplate
Each Filter Fan includes an identification nameplate. This nameplate provides:
CAUTION
Operate this unit only on the proper voltages and frequencies as noted on the nameplate
Model Number Electrical Power Characteristics Serial Number
We recommend you copy this information from your unit.
When ordering parts, specify
the Model Number.
Before operating, be sure
that the power source matches these requirements.
Filter Fan
MODEL NO.
SERIAL NO.
AMPSPH.FREQ.VOLTS
FINAL ASSY. NO.
M.O. NUMBER
SERVICE AIR FILTERS REGULARLY
UNAUTHORIZED SERVICE OR MODIFICATION
ALL MOTORS ARE
THERMALLY PROTECTED
OUTDOOR USE
DO NOT USE AN
EXTENSION CORD
MANUFACTURED BY:
VIOLATES WARRANTY
NEMA TYPE 4
MAINTAINED
WITH THIS FAN
E361673
CONFORMS TO UL STD. 507, UL STD 50E; CERTIFIED TO CSA STD C22.2 NO. 113
5
VI. Installation Instructions
The Guardian Series NEMA 4 or 4X Filter Fans have been engineered to be installed easily. These NEMA 4 or 4X filter fans have been designed for indoor or outdoor use. Prior to mounting, refer the mounting drawings below showing dimensions and locations of mounting holes and cutouts. Prior to cutting or drilling, make sure that cutouts and mounting holes do not interfere with components inside the cabinet. When mounting your filter fan please keep the following in mind:
VII. Drawings and Dimensions
Dimensions, inches[mm] are for reference only and subject to change.
KNP60FL
Proper orientation of unit is filter at the bottom.
A minumum of 6 inches clearance from filter to the nearest surface is recommended.
Use neoprene washers provided.
Recommended torque of 35-in-lbs for proper gasket compression.
MOUNTING PLAN
9.85
[250.1]
6.12
[155.4]
4.62
[117.3]
(4) 1/4" -20 CAGE NUTS
FILTER WITH REMOVABLE GUARD
AIR OUT
AIR IN
16.56
[420.6]
1.86
[47.2]
2.81
[71.4]
2.61
[66.3]
POWER CORD
18.00
[457.2]
5.01
[127.2]
1.86
[47.2]
13.75
[349.2]
2.81
[71.3]
[42.6]
2.61
[66.3]
1.68
6.12
[155.4]
6.50
[165.1]
4.62
[117.3]
7.12
[180.8]
8.99
[228.3]
(4) .312 [7.9] DIA. HOLES
6
VIII. Specific Model Data
IX. Packing Procedure For Warranty Repair
Pack the Filter Fan in an appropriate carton (preferably the original carton), with adequate internal protective packaging, making sure carton is marked properly.
Technical Data
KNP60FL 115 VAC 50/60 .42/.34 43/37 270/290 -40 158 11.3
K2NP60FL 230 VAC 50/60 .20/.17 37/36 270/290 -40 158 11.3
KNP60FLV 115 VAC 50/60 .42/.34 43/37 270/290 -40 158 11.3
K2NP60FLV 230 VAC 50/60 .20/.17 37/36 270/290 -40 158 11.3
Unit Operating Approximate
Frequency Imput Imput Airflow Temp. ºF Weight
Model Voltage Hz Amps Watts CFM Min. Max. (lbs.)
Standard Features
Filter Integrated Fan Guards Integrated Sealing Gasket IP55 Filter Protection NEMA 4 or 4X Rating Maintained (if used with provided filter) Secure Mounting Stainless Steel Shell (NEMA 4X models) Baked Powder Finish UL/CSA Shielded Ball Bearing Motors UL/CUL Listed
Replacement Filters
Filter
Model Part Number
KNP60FL 0429-01-01 K2NP60FL 0429-01-01 KNP60FLV 0429-01-01 K2NP60FLV 0429-01-01
Optional Filter-Hood Assemblies
Filter Hood Assembly
Model Part Number
KNP60FL KNPA60FL K2NP60FL KNPA60FL KNP60FLV KNPA60FLV K2NP60FLV KNPA60FLV
7
X. Maintenance
Kooltronic Guardian/GuardianX NEMA 4 or 4X Series Indoor/Outdoor Filter Fans require no maintenance. These Filter Fans are designed to require only the routine cleaning of air filters to assure unimpeded airflow through the unit. It is not possible to recommend specific cleaning intervals, since the level and nature of airborne particulate matter differs widely with each installation. It is generally sufficient to remove and wash the reuseable aluminum mesh air filters when the outer surfaces of these filters appear covered with a thin layer of dust or lint. Filter coating adhesive, available from Kooltronic, is recommended (Part number A-16 - 10 oz. container). Replacement filters are also available from Kooltronic. See page 6 for part numbers.
If filter service is neglected or delayed, the filter fans will not perform at design capacity. The first indication of an excessively clogged filter is usually a gradual increase of temperature within the equipment cabinet.
Filter removal and service
Kooltronic Guardian/GuardianX NEMA 4 or 4X Series Indoor/Outdoor Filter Fans feature an easily removable filter to facilitate necessary cleaning.
CAUTION
1) On the bottom of the unit, pull the filter retainer away from the cabinet and downward to remove filter and filter retainer.
2) After removal, the filter should be flushed under warm running water with the clean side up, driving contaminants out of the dirty side of the filter. If the accumulated dirt is oily, washing in a detergent bath is recommended, followed by a warm water rinse as above.
3) Reinstall the filter and filter retainer, making sure that the retainer legs face toward the cabinet.
Do not operate the filter fan for extended periods of time with the filter removed. Operation with
the filter in place is necessary for the fan to maintain its NEMA rating.
XI. Standard Warranty
THIS WARRANTY CONSTITUTES THE ENTIRE WARRANTY WITH RESPECT TO THE PRODUCT AND IS IN LIEU OF ALL OTHERS, EXPRESSED OR IMPLIED, INCLUDING ANY WARRANTY OF MERCHANTABILITY AND WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE AND IN NO EVENT IS KOOLTRONIC RESPONSIBLE FOR ANY CONSEQUENTIAL DAMAGES OF ANY NATURE WHATSOEVER.
RETURN AUTHORIZATION (RA) PROCEDURE
KOOLTRONIC products are warranted to be free of defects in workmanship, materials and components. The following warranty periods apply from date of shipment:
Air moving devices/components and hermetic system components: One year
Non-operating parts, except filters: 5 years
The above warranty applies when the equipment is operated under the following conditions:
Ambient temperature not in excess of 125°F (52°C) in normal atmosphere or as stated on product nameplate
Voltage variation no greater than ± 10% from nameplate rating
Frequency variation no greater than ±3Hz from nameplate rating
Maximum cooling load no higher than air conditioner nameplate rating
Waiting five minutes before restarting air conditioner after intentional or accidental shutoff
Compliance to all other installation, maintenance and operating instructions, as supplied
The purchaser assumes the responsibility of grounding the unit and installing it in accordance with local electrical and safety codes, as well as the National Electric Code (NEC) and OSHA
KOOLTRONIC cannot assume responsibility for mis-application of its products or the erroneous selection of an inappropriate product by a non­authorized KOOLTRONIC representative. Our applications engineers will gladly assist in the selection of the proper product, provided all required details of the application are furnished.
All returns require a Return Authorization number whether the return is for warranty or non-warranty repair, rotation of stock, damage or any other reason. Returns without an RA number will be refused.
The following information is required when an RA is requested:
- Original customer Purchase Order number and date
- Date product was received by customer
- Number of parts to be returned
- Product description, model and serial number
- Reason for return
- Action requested
- Contact name, telephone, FAX numbers and e-mail address
Pack unit in a suitable container for shipment, preferably the
original packaging if available. All Air Conditioners must be returned in an upright position properly secured to a pallet. Improper packaging may void warranty claim. If an Air Conditioner is received laying down or shipped via UPS or similar small parcel service the warranty will be void.
Mark carton prominently with KOOLTRONIC’s Return Authorization Number.
Enclose all pertinent documents.
Freight charges on all products returned to KOOLTRONIC shall be paid by the customer. Unauthorized collect shipments will be refused.
If a unit is repaired under Warranty, KOOLTRONIC will pay the freight charges both ways within the Continental USA at KOOLTRONIC’s negotiated rates. Warranty repaired units will be returned to customer at KOOLTRONIC expense only within the Continental USA.
All authorized returns are subject to a restocking fee.
KOOLTRONIC assumes no liability beyond the repair or replacement of its own product. This Warranty does not cover:
Labor or reimbursement of labor for evaluation, removal, installation, repair, or cost of any warranted part, unless authorized in writing by KOOLTRONIC
Use of equipment for other than its designed purpose or operating conditions
Operation in harsh, oily, corrosive or other abnormal environmental conditions, without the proper filtration, sealing, protective coatings and/or weather protection
Damage to hermetic system resulting from continuous operation with dirty or clogged air filters or improper or negligent maintenance
Use of refrigerant other than designated
Customer modification or abuse
Shipping damage or other accident (Claims for shipping damage are the responsibility of the customer. Timely claims must be filed by the customer with the freight carrier)
Cracked or broken hermetic tubing, brazed joints or other internal damage caused by shipping or mishandling
Damage caused by shipping units attached to an enclosure
Any and all conditions resulting from noncompliance with the preceding operating conditions
Returned freight must be paid by customer
This standard warranty does not apply to custom products. Consult your KOOLTRONIC representative for limitations
8