KoolSola TKFR-26GW, TKFR-35GW, TKFR-60GW, TKFR-72GW User Manual

Manual for the Installation of
Solar Thermal Air Conditioners
Koolsola TKFR-26GW Koolsola TKFR-35GW Koolsola TKFR-60GW Koolsola TKFR-72GW
Operating Instructions and Installation Guide
Wall Mounted Split System
Version 1.0
Notes to Users
We appreciate you purchasing a Koolsola Solar Air Conditioning System. With your purchase you will enjoy the benefits of power savings and affordable comfort for many years to come. To understand how your Koolsola Solar Air Conditioning System works and to ensure the best performance from your System please read the following information before installing or using the system.
1) The Koolsola Solar Air Conditioning System must be installed by a qualified, licensed Air
Conditioning Installer.
2) The ‘Installation Guide’ section on this manual is specifically for qualified, licensed Air
Conditioning Installers to refer to whilst carrying out installation.
3) Please ensure that you read the ‘Operating Instructions’ section of this manual before using
your system.
Operating Instructions and Installation Guide
Wall Mounted Split System
Version 1.0
Contents
1. General Information
1.1. System Specifications Page 5
1.2. Safety Information Page 9
1.3. System Operating Principles Page 10
1.4. System Components Page 11
2. Operating Instructions
2.1. General Operating Instructions Page 13
2.2. Remote Control Function Page 14
2.3. Routine Maintenance Page 18
2.4. Troubleshooting Page 21
3. Installation Guide
3.1. General Installation Information Page 25
3.2. Indoor Unit Installation Page 28
3.3. Outdoor Unit Installation Page 30
3.4. Evacuate Tube Solar Collector Installation Page 31
3.5. Flat Panel Solar Collector Installation Page 34
3.6. Gassing Installation Page 36
3.7. Wiring Installation Page 39
Operating Instructions and Installation Guide
Wall Mounted Split System
Version 1.0
Section 1
General Information
Operating Instructions and Installation Guide
Wall Mounted Split System
Version 1.0
1.1
System Specifications
Koolsola TKFR-26GW
Rated Cooling Capacity (Watts) 2600 Rated Heating Capacity (Watts) 2900 Rated Power Input (Volts/Hertz) 220V/50Hz/60Hz Rated Cooling Power Input (Watts) 650 – 770 Rated Cooling Input Current (Amperes) 2.95 – 3.50 Maximum Cooling Power Input (Watts) 962 Maximum Cooling Input Current (Amperes) 4.38 Rated Heating Power Input (Watts) 650 – 780 Rated Heating Input Current (Amperes) 2.95 – 3.55 Maximum Heating Power Input (Watts) 975 Maximum Heating Input Current (Amperes) 4.44 Auxiliary Electric Heating Rated Power Input (Watts) 600 Auxiliary Electric Heating Rated Input Current (Amperes) 2.73 Inhaling Maximum Working Pressure (Megapascals) 1.15 Exhausting Maximum Working Pressure (Megapascals) 4.1 Type of Refrigerant R-410A Standard amount of Refrigerant (grams) 800 Air Circulation of Outdoor Unit (Metres cubed/hour) 450 Waterproof Grade 1PX4 Net Weight Outdoor Unit (Kilograms) 30 Net Weight Indoor Unit (Kilograms) 8 Dimensions Outdoor Unit (Millimetres – Length/Width/Height) 790/260/540 Dimensions Indoor Unit (Millimetres – Length/Width/Height) 700/230/160 Noise Level Outdoor Unit (Decibels) < 50 Noise Level Indoor Unit (Decibels) < 40
Parameters in this table are measured in the rated working state of an outdoor temperature of 35oC dry bulb/24oC wet bulb and an indoor temperature of 27oC dry bulb/19oC wet bulb. Working states at varying temperatures may change.
Operating Instructions and Installation Guide
Wall Mounted Split System
Version 1.0
Koolsola TKFR-35GW
Rated Cooling Capacity (Watts) 3500 Rated Heating Capacity (Watts) 3800 Rated Power Input (Volts/Hertz) 220V/50Hz/60Hz Rated Cooling Power Input (Watts) 800 – 1025 Rated Cooling Input Current (Amperes) 3.64 – 4.66 Maximum Cooling Power Input (Watts) 1280 Maximum Cooling Input Current (Amperes) 5.83 Rated Heating Power Input (Watts) 800 – 1050 Rated Heating Input Current (Amperes) 3.64 – 4.77 Maximum Heating Power Input (Watts) 1310 Maximum Heating Input Current (Amperes) 5.96 Auxiliary Electric Heating Rated Power Input (Watts) 800 Auxiliary Electric Heating Rated Input Current (Amperes) 3.63 Inhaling Maximum Working Pressure (Megapascals) 1.15 Exhausting Maximum Working Pressure (Megapascals) 4.1 Type of Refrigerant R-410A Standard amount of Refrigerant (grams) 1150 Air Circulation of Outdoor Unit (Metres cubed/hour) 550 Waterproof Grade 1PX4 Net Weight Outdoor Unit (Kilograms) 38 Net Weight Indoor Unit (Kilograms) 10.5 Dimensions Outdoor Unit (Millimetres – Length/Width/Height) 790/260/540 Dimensions Indoor Unit (Millimetres – Length/Width/Height) 785/285/210 Noise Level Outdoor Unit (Decibels) < 52 Noise Level Indoor Unit (Decibels) < 42
Parameters in this table are measured in the rated working state of an outdoor temperature of 35oC dry bulb/24oC wet bulb and an indoor temperature of 27oC dry bulb/19oC wet bulb. Working states at varying temperatures may change.
Operating Instructions and Installation Guide
Wall Mounted Split System
Version 1.0
Koolsola TKFR-60GW
Rated Cooling Capacity (Watts) 6000 Rated Heating Capacity (Watts) 6600 Rated Power Input (Volts/Hertz) 220V/50Hz/60Hz Rated Cooling Power Input (Watts) 1350 – 1560 Rated Cooling Input Current (Amperes) 6.14 – 7.09 Maximum Cooling Power Input (Watts) 1950 Maximum Cooling Input Current (Amperes) 8.86 Rated Heating Power Input (Watts) 1350 – 1590 Rated Heating Input Current (Amperes) 6.14 – 7.23 Maximum Heating Power Input (Watts) 2000 Maximum Heating Input Current (Amperes) 9 Auxiliary Electric Heating Rated Power Input (Watts) 1500 Auxiliary Electric Heating Rated Input Current (Amperes) 8.1 Inhaling Maximum Working Pressure (Megapascals) 1.15 Exhausting Maximum Working Pressure (Megapascals) 4.1 Type of Refrigerant R-410A Standard amount of Refrigerant (grams) 1600 Air Circulation of Outdoor Unit (Metres cubed/hour) 850 Waterproof Grade 1PX4 Net Weight Outdoor Unit (Kilograms) 55 Net Weight Indoor Unit (Kilograms) 21 Dimensions Outdoor Unit (Millimetres – Length/Width/Height) 940/300/755 Dimensions Indoor Unit (Millimetres – Length/Width/Height) 985/325/230 Noise Level Outdoor Unit (Decibels) < 56 Noise Level Indoor Unit (Decibels) < 46
Parameters in this table are measured in the rated working state of an outdoor temperature of 35oC dry bulb/24oC wet bulb and an indoor temperature of 27oC dry bulb/19oC wet bulb. Working states at varying temperatures may change.
Operating Instructions and Installation Guide
Wall Mounted Split System
Version 1.0
Koolsola TKFR-72GW
Rated Cooling Capacity (Watts) 7200 Rated Heating Capacity (Watts) 7900 Rated Power Input (Volts/Hertz) 220V/50Hz/60Hz Rated Cooling Power Input (Watts) 1700 – 1900 Rated Cooling Input Current (Amperes) 7.73 – 8.64 Maximum Cooling Power Input (Watts) 2375 Maximum Cooling Input Current (Amperes) 10.8 Rated Heating Power Input (Watts) 1700 – 1950 Rated Heating Input Current (Amperes) 7.73 – 8.64 Maximum Heating Power Input (Watts) 2440 Maximum Heating Input Current (Amperes) 10.8 Auxiliary Electric Heating Rated Power Input (Watts) 1800 Auxiliary Electric Heating Rated Input Current (Amperes) 8.18 Inhaling Maximum Working Pressure (Megapascals) 1.15 Exhausting Maximum Working Pressure (Megapascals) 4.1 Type of Refrigerant R-410A Standard amount of Refrigerant (grams) 1800 Air Circulation of Outdoor Unit (Metres cubed/hour) 1050 Waterproof Grade 1PX4 Net Weight Outdoor Unit (Kilograms) 62 Net Weight Indoor Unit (Kilograms) 19 Dimensions Outdoor Unit (Millimetres – Length/Width/Height) 940/300/755 Dimensions Indoor Unit (Millimetres – Length/Width/Height) 985/325/230 Noise Level Outdoor Unit (Decibels) < 54 Noise Level Indoor Unit (Decibels) < 42
Parameters in this table are measured in the rated working state of an outdoor temperature of 35oC dry bulb/24oC wet bulb and an indoor temperature of 27oC dry bulb/19oC wet bulb. Working states at varying temperatures may change.
Operating Instructions and Installation Guide
Wall Mounted Split System
Version 1.0
Safety Information
Safety Warnings:
The Koolsola Solar Air Conditioning system should only be installed repaired and maintained by
a qualified, licensed air conditioning installer.
Please switch off the power to the system in the event of an electrical storm in order to prevent
damage to the system.
Please switch off the power to the system when it is not in use for long periods of time. Please switch off the power to the system before conducting any cleaning of or maintenance of
the system.
Never clean the system with liquid detergents liquefied cleaning agents or corrosive cleaning
agents. Never allow the indoor unit to come into contact with liquid. Any of these actions may cause damage to the plastic accessories and casings or cause damage to the electrical components.
Never insert your hands or any other object into the air outlet of the indoor and outdoor units
to ensure that there is no damage to the high-speed fan or the object being inserted.
Never allow children to play the system. Never remove any of the coverings of the system. Never allow moisture to get into the remote control. Never put or use any combustible liquid or substance such as hair spray, paint or petrol near the
machine to prevent the possibility of fire.
If any unusual circumstances occur, including but not limited to; strange noises or smells,
smoke, abnormal temperature increases or changes to appearance of components please switch off the power immediately and contact your local distributor of the Koolsola Solar Air Conditioning System. Do not attempt to repair the system yourself.
Pre-checking before operation:
Please refer to the Section 2.3 – Routine Maintenance to establish the correct method for cleaning the air filter and checking/filling the solar collector with water.
If the system has been switched off/idle for a long period of time please clean the air filter before turning the system back on.
If the system has been switched off/idle for a long period of time please check the level of the water in the solar collector and add water if required.
In normal operating conditions please clean the air filter every 2 weeks.
In normal operating conditions please check the level of the water in the solar collector every 3 months and add water if required.
Operating Instructions and Installation Guide
Wall Mounted Split System
Version 1.0
1.2 System Operating Principles
The Koolsola Solar Air Conditioning System uses both mains electrical power and solar thermal
energy. The Koolsola Solar Air Conditioning System always requires mains electrical power to operate fans and electrical control components.
The Koolsola Solar Air Conditioning System uses solar thermal energy as an energy source to
help maintain the refrigeration process which in turn reduces the amount of electrical energy required to run the compressor.
The Koolsola Solar Air Conditioning System operates under the same principles as a
Conventional Air Conditioning System where refrigeration takes place as a result of the phase transition of the refrigerant.
The difference between a Koolsola Solar Air Conditioning System and a Conventional System is
how the vapour is changed back into a liquid state in the refrigeration cycle.
A Conventional System uses a compressor to increase the pressure of the refrigerant when it’s
in a vapour state so that when it enters the condenser coil the combination of pressure and cooling from ambient air condenses it into a liquid in the coil. The change of state of refrigerant begins to take place approximately two thirds of the way down the condenser. The Koolsola Solar Air Conditioning System improves on this basic method by using solar thermal energy collected in a solar collector to add thermal energy to the refrigerant vapour. By using this method it reduces the amount of compression required to achieve the refrigeration cycle, as well as utilising more of the cooling face of the condenser coil.
By reducing the amount of compression required to achieve the refrigeration process the
Koolsola Solar Air Conditioning System can use an undersized compressor in comparison to a Conventional System. Similarly if enough solar thermal energy is being collected and utilised the compressor will run less often in a Koolsola Solar Air Conditioning System than a Conventional System.
The Koolsola Solar Air Conditioning System incorporates off centre fan blade technology,
insulated foam ducts and high performance brand name compressors to achieve optimum performance at a minimum level of noise. The Koolsola Solar Air Conditioning System typically creates 10dBA less noise than a Conventional System.
Operating Instructions and Installation Guide
Wall Mounted Split System
Version 1.0
1.4 System Components
Please note that the graphic example below is based on the standard Koolsola Solar Air Conditioning System and may be slightly different in various configurations.