Koolance CTR-SPD1224M User Manual

1
CAUTION: Improperly connecting the speed controller can damage it, the
pump, or the power supply. Ensure that total device load does not exceed the
!
maximum rating of the controller (36W@12VDC, 50W@24VDC). Ensure that the connected device will safely accept the voltage being supplied (12V or 24V depending on the jumper setting).
The Koolance CTR-SPD1224M uses voltage control to throttle speeds for 12VDC pumps or fans. With a jumper setting, it will also step-up and throttle volt­age for 24VDC devices. CTR-SPD1224M requires a 12VDC input.
2
For pumps with larger Molex connectors, use the larger (2-wire, 4 position) connector on the wiring harness.
Connect the 3-pin plug from the wiring har­ness to the controller.
Pump
Wiring Harness
Do not operate components at voltages which exceed their specifications. Running a 12V-max pump at 24V from the speed controller can damage the pump.
T o avoid damaging the speed controller , do not con­nect devices which exceed the controller’s maximum power rating (36W@12V , 50W@24V).
Connect One
to Pump
Connect to
Controller
Use the wiring harness included with your speed controller. This will accept the pump or fan connection.
Wiring Harness
For 3-pin pumps or fans, connect this to the available plug on the wiring harness.
Power In (12VDC)
Power Out
(Pump, Fan, etc.)
3-pin Pump
or Fan
Wiring Harness
Finally, connect the power supply to the controller.
Pump tachometer signals are not used by the speed controller. If your pump has an integrated speed knob, it should be left on the maximum setting when adjusting
Pumps with built-in control
should be left on maximum
speed
Voltage Jumper
speed via the Koolance controller.
CTR-SPD1224M has a jumper to select from 12V (max) or 24V (max) speed control.
!
Power Supply
CAUTION: Do not power 12V pumps or
other devices with the 24V setting! This can permanently damage the attached device.
Loading...