11002347AA
date of change: 20.08.2014
Page: 2/19
Contents
Page
1 Technical data of control unit...........................................................................................3
2 General description of the control unit............................................................................4
2.1 LED-display .........................................................................................................................4
2.2 Programming Menu .............................................................................................................4
2.3 Connecting and Safety instructions......................................................................................5
2.4 Functions of buttons ............................................................................................................6
2.5 Factory setting / delivery state FR4.1...................................................................................6
3 Switching-on the unit ........................................................................................................7
3.1 Switching-on the refrigeration unit by button of FR4.1....................................................7
3.2 Indication and change of setpoint ........................................................................................7
3.3 Sampling of operating hours................................................................................................8
3.4 Sampling of operating hours since last service ...................................................................8
3.5 Sampling of the temperature values of room sensor and evaporator sensor........................8
4 Faults – indications and signals.......................................................................................8
5 Adjustment of Parameters in the menu ...........................................................................9
5.1 Example for change of a parameter, here parameter defrost interval “d.dı” .........................9
5.2 Conversion to cooling with recirculated air defrosting / or replace a FR1, FR2,FR3 or FR4 .9
5.3 Conversion to cooling – heating with hotgas – defrosting with hotgas................................10
6 Control of defrosting.......................................................................................................10
7 Configuration of the parameters with “FR 4 copy-key”................................................11
8 Logic >> Explanations for the functions of the control conditions..............................12
8.1 Cooling and defrosting with hot gas >> delivery state FR4...........................................12
8.2 Cooling and defrosting with recirculated air >> see changes in parameters point 5.2. .......12
8.3 Neutral zone (cooling + heating with hot gas) and defrosting with hot gas >> see changes
in parameters point 5.3. ....................................................................................................12
9 Connection diagram and parameter chart.....................................................................13
9.1 Connection diagram...........................................................................................................13
9.2 Parameter chart.................................................................................................................13