Konlen MOBILE CALL GSM Alarm, MOBILE CALL System User Manual

Profile
MOBILE CALL
GSM Alarm System
For a better understanding of this product, please read this user
manual thoroughly before using it.
USER’ MANUAL
Konlen Technology--The proffessional home alarm system provider
www.konlen.com
1-1
1-4
4-4
4-4
4-5
5-5
5-5
5-6
6-6
6-6
7-7
7-7
7-7
7-8
8-8
9-9
9-9
9-9
10-10
10-10
10-10
10-11
11-11
CONTENTS
Function Introduction
Alarm Host Diagram
Functions Settings
Initialization
Enter Settings
Exit Settings
Factory Reset
Coding of Remote Controller
Delete Remote Controller
Coding of Defense Zone
Delete Defense Zone
Change Password
Change Operation Password
Change Program Password
Clock Setting
Timing Settings
Timely Arm
Timely Disarm
Timing Control
Out Arm Delay Setting
Alarm Delay Setting
Alarm Number Setting
Delete Phone Number
11-12
12-12
12-12
12-13
13-13
14-14
14-14
15-15
15-15
15-15
16-16
15-15
16-17
17-17
17-18
18-18
18-18
18-19
20-20
21-21
22-22
22-22
19-19
CONTENTS
SMS Number Setting
Delete SMS Number
SMS Notification for Arm/Disarm
Defense Zone Programming
Home Arm Defense Zone Setting
Voice Recording
Siren Setting
Operation Instructions
System Status
Remote Controller Operate
Out Arm
Home Arm
Disarm
Answer Alarm Call
Remote Control
Emergency Help
System Dialing Function
Alarming Record Checking
Notes
Technical Parameters
Components List
Care and Maintenance
GSM Signal Checking
ΚΜ
ΚΜ
1
7 wired and 99 wireless defense zones; LCD screen with time clock display; Voice prompt for all operations; 3 groups of timely arm and disarm; Can store 6 phone numbers: when alarming, system will make alarm call to these numbers automatically;
Can store 3 SMS numbers: when alarming, system will send alarming SMS
automatically; 10-second automatic message recording; Built-in artificial intelligent digital voice announcer; Built-in artificial intelligent English message; U
sers can make calls by using keypad on alarm panel, just like a telephone;
One-key-control function: Out Arm, Home Arm, Remote Arm; Arm/ disarm by SMS or call remotely; SOS, fire, gas, door, hall, window, balcony, and boundary places alarm; Real-time, delay, 24 hours, bypass defense zones programming function; Wireless coding: easy to add additional wireless accessories; Remote control Arm, Disarm, Monitor, and Intercom by phone; SMS alert for power failure or recovery; Built-in AAA NI-HI rechargeable battery: make alarm when power off.
In order to make the main unit get the wireless signal well for all wireless accessories, please put the alarm host at the
central place of your defense
area. Make sure it’ away from large metal objects and house hold appliances which may cause high frequency interference,
as well as barriers such as
reinforced concrete wall or fire door, etc.
Function Instruction
Alarm Host Diagram
s
Function Introduction
Alarm Host Diagram
2
Wired terminal block:
Alarm Panel front schematic diagram:
Alarm Panel back schematic diagram:
Speaker PIR Siren
Alarm Host Diagram
Alarm Host Diagram
LB-
LB+
GND
Z1
GND
Zone 2
Zone 3
GND
Zone 4
Zone 5
GND
Zone 6
Zone 7
1. “LB -” and “LB +”are to connect external speaker. If you think the internal speaker is not loud enough, pleasecontact us for professional speakers.
2. Connect one cable of the wired sensor to GND and the other to “Z1/Z2/Z3…/Z7”.
Ground
Wired sensor 2: support both NO and NC
Wired sensor 3: support both NO and NC
GND
GND
Wired sensor 4: support both NO and NC
Wired sensor 5: support both NO and NC
Positive of siren (red cable)
Negative of siren (black cable)
Wired sensor 7: support both NO and NC
Wired sensor 6: support both NO and NC
Positive of two-way speaker (red cable)
Negative of two-way speaker (black cable)
Ground
Wired sensor 1: support both NO and NC
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
SP+
SP-
3. Please pay attention to the siren connection. Do not mix the two cables together when connecting. Otherwise, it will damage the transistor in the main panel.
Note:
3
Alarm Host Diagram
Alarm Host Diagram
LCD display:
1. Initialization
Please insert SIM card and plug in power adaptor, and then power on the
system, all the LED lights will be on for 2 seconds and you will hear a long
beep; the system comes into initialization. After the time clock displays on the LCD screen, the [GSM
] starts flashing and the main unit starts to detect the GSM network until a long beep. Then the [GSM
] indicator goes out indicating the system comes into disarm status. Finally, turn on the backup battery switch.
In the state of disarm, input 4-digit password by the keypad on the main
unit and press [ # ] button to confirm. You will hear a voice prompt: please
enter instruction. At the same time, [ SET ] indicator is on without flashing
and [0000] displays on the screen, indicating the system enters setting status.
You can perform different settings repeatedly as long as the system keeps in
setting status. The system will exit setting mode and return to disarm status
if you don’t press any keypad button for 40 seconds.
2. Enter Settings
ΚΜ
Functions Settings
4
Alarm Host Diagram
Functions Settings
Note: In setting status, press
Operating method: [ XXXX ] [#]
Ö
Ö
X
indicates the new 4-digit password.
LCD display:
Press [ ] and [#] buttons, the main unit emits a long beep and exits settings. The [ SET
] indicator goes out and the system returns to disarm state.
5VKXGZOTMSKZNUJ 澬澭澬#
*
*
In disarm status, use keypad to input [95175308246] and press [#] to confirm,
all the LED indicators will be on for 2 seconds and you will hear a long beep. The main unit gets all its settings cleared and restores to its factory settings successfully. Operating method: [95175308246
] + [#]
The remote controller has to be code to the alarm host in order to perform
normally.
In setup state, use keypad to input [20], input the remote controller number [1~8
], and then press [ # ] to confirm. The main unit emits a long beep and
you will hear “ remote control coding ”. The [ ] indicator is on without
flashing; press any button on the wireless remote controller, the main unit
makes a long beep and you will hear “coding completed”, [ ] indicator
goes out, indicating the remote controller succeeds in coding.
Ö
Ö
Operating method: [20
] [A] [#]
A indicates: 1~8 remote controllers number.
5. Coding of Remote Controller
3. Exit Settings
4. Factory Reset
5
Functions Settings
Functions Settings
can delete the numbers input.
The system default password is [8888].
ÖÖ
Ö
Ö
You can add maximum 8 remote controllers.
LCD display:
A indicates: 1~8 remote controllers number.
XX
indicates: 01 ~99 defense zones number
LCD display:
6
Functions Settings
Functions Settings
In setup state, use keypad to input [21 ], then input the remote controller number [1-8
], and then press [ # ] to confirm. The main unit emits a long
beep and the [Signal
] indicator flickers once. You will hear a voice prompt
“delete completed”.
Operating method: [21] [A] [#]
In setup state, use keypad to input [23
], input the defense zone number
you want to code [ 01~99 ], and then input [#] to confirm. The main unit
emits a long beep and the corresponding defense zone is displayed on
the screen. You will hear a voice prompt “detector coding”.
Then trigger a wireless detector to emit a wireless signal; after receiving
the signal, the main unit makes a long beep, and you will hear “coding
completed”, the [ ] indicator goes out at the same time.
7. Coding of Defense Zone
Operating method: [23] [XX] [#]
6. Delete Remote Controller
‘t
‘s
The remote controller can control the main unit after it deleted.
Wireless detectors have to be coded to the main unit in order to trigger
it alarm.
ÖÖ
ÖÖ
ÖÖ
In setup state, use keypad to input [24
], then input the defense zone
number you want to delete [ 01~99
], and then input [#] to confirm. The main unit emits a long beep and the defense zone indicator flickers once. You will hear a voice prompt “delete completed”.
Operating method: [24
] [XX] [#]
XX
indicates: 01 ~99 defense zones number
In setup status, use keypad to input [30], then input the 4-digit new
password, and then press [#] to confirm. The main unit will make a long
beep and you will hear a voice prompt “setting completed”. Operating method: [30
] [XXXX] [#]
XXXX
indicates: the new 4-digit password For example: change the system password to 1012 Operating method: [30
] [1012] [#]
LCD display:
In setup status, use keypad to input [ 31 ], then input the 4-digit new
password, and then press [#] to confirm. The main unit will make a long
beep and you will hear a voice prompt “setting completed”.
8. Delete Defense Zone
9. Change Password
2). Change Program Password
The wireless detector can’ control the main unit after it’ deleted.
1). Change Operation Password
Operation password is the password used to disarm or remote control.
Program password is the password you should input in order to setup
the system.
t
s
7
Functions Settings
Functions Settings
ЦЦЦЦЦЦЦ
ЦЦЦЦЦЦЦ
ÖÖ
Operating method: [31
] [ XXXX ] [#] XXXX indicates: the new 4-digit password For example: change the system password to 2846
LCD display:
Ö
Ö
Operating method: [31
] [2846] [#]
Note: the operation password and the programming password can not
be set as the same number.
In setup status, use keypad to input [32], then input the last 2 digits [AA] of the present year, the two digits [BB
] of the month, the two digits [CC]
of the date, the two digits [DD] of the hour (24-hour system), the two digits [EE
] of the minute, the two digits [FF] of the second, and finally
enter [ #
] to confirm. You will hear a long beep and a voice prompt
“setting completed”. Operating method: [32
] [AA] [BB] [CC] [DD] [EE] [FF] [#]
AA indicates: the last 2 digits of the present year
BB indicates: the 2 digits of the present month CC indicates: the 2 digits of the present date
DD indicates: the 2 digits of the present hour EE indicates: the 2 digits of the present minute FF indicates: the 2 digits of the present second For example: set the time as 15:35:40, Oct. 1st, 2009 Operating method: [32
] [09] [10] [01] [15] [35] [40] [#]
10. Clock Setting
8
Functions Settings
Functions Settings
ÖÖÖ
ÖÖÖ
ÖÖÖ
ÖÖÖ
XX
indicates: the address code 33, 34, 35 of the timely arming
AA
indicates: the hour of the setting time
BB
indicates: the minute of the setting time For example: set the arm time as 45’10pm Operating method: [33
] [22] [45] [#]
1 ). Timely Arm
In setup status, use keypad to input [33~35], then input the hour [AA]
and minute [BB] of the time you want to set to arm, and finally input [#]
to confirm. You will hear a long beep and a voice prompt “setting completed”.
LCD display:
In setup status, use keypad to input [36~38], then input the hour [AA]
and minute [BB
] of the time you want to set to disarm, and finally input
[#
] to confirm. You will hear a long beep and a voice prompt
“setting completed”.
Operating method: [XX] [AA] [BB] [#] XX indicates: the address code 36, 37, 38 of the timely disarming AA indicates: the hour of the setting time
BB indicates: the minute of the setting time For example: set the arm time as 55’7am Operating method: [33
] [22] [45] [#]
LCD display:
11. Timing Settings
2). Timely Disarm
Operating method: [XX] [AA] [BB] [#]
9
Functions Settings
Functions Settings
Ö
ÖÖ
Ö
3). Timing Control
In setup status, use keypad to input [39], then input the number indicating
turning on timely arm/ disarm [1/0], and then input [#] to confirm. You will
hear a long beep and a voice prompt “setting completed”. The factory
default is off. Operating method: [39
] [0/1] [#] 0: turn off the function of timely arm/ disarm 1: turn on the function of timely arm/ disarm For example: turn on the function of timely arm/ disarm Operating method: [39
] [1] [#]
In setup state, input the command: 44 + [XX
] + # XX indicates: the delay time of out arm; XX= 01-99: 1 sec to 99 sec Note: The setting is effective only with the keypad operation. The operation by remote controller or SMS is immediate arm without delay.
In setup state, input the command: 45 + [XX
] + # XX indicates: the delay time of alarm; XX= 01-99: 1 sec to 99 sec
Note: The setting is effective only when a zone is set as Alarm Delay Zone.
Note: Before the system enters arm or alarm status it will emit a "Di" sound per second.
ÖÖOperating method: [XX
] [YY…YY] [#]
Time Setting for Out Arm Delay (Default: 60 sec)
Time Setting for Alarm Delay (Default: 40 sec)
In setup state, input [ 51] ~ [ 56 ], then input the voice alarm-receiving number (mobile number or telephone number), and then press [#
] to
confirm. The main unit will make a long beep, the [Signal
] indicator will flicker once, and you will hear “setting completed” , which indicate voice alarm-receiving number is set successfully.
12. Alarm Number Setting
10
Functions Settings
Functions Settings
Ö
Ö
ÖÖ
XX
indicates: the 1- 6 alarming user number [51] ~ [56]
YY….YY
indicates: voice alarm-receiving phone number For example: set 13811111111 as the first voice call number Operating method: [51
] [13811111111] [#]
LCD display:
In setup state, input [51] ~ [56], and then press [#] to confirm, the main
unit will make a long beep and the [Signal] indicator will flicker once and
you will hear “delete completed”, which indicate the alarming user number is deleted successfully.
Operating method: [XX
] [#]
XX indicates: the 1- 6 alarming user number [51
] ~ [56] For example: Delete the third alarming user number from the system. Operating method: [53
] [#]
LCD display:
ÖÖ
In setup state, input [57] ~ [59], then input the SMS receiving number,
and then press [#] button to confirm. The main unit will make a beep, the
[Signal] indicator will flicker once and you will hear “setting completed”, which indicate setup successfully. Operating method: [XX
] [YY…YY] [#]
XX indicates: address codes of message-receiving numbers from the first
group to the third group [57] ~ [59] YY…YY indicates: the SMS receiving number
SMS Receiving number means when system is alarming, it will only send
SMS to this mobile number. You can set maximum 3 SMS numbers.
13. Delete Phone Number
14. SMS Receiving Number Setting
11
Functions Settings
Functions Settings
Ö
Ö
In setup state, use keypad to input [57] ~ [59], a nd then press [#] button
to confirm. The main unit will make a beep, the [ Signal ] indicator will
flicker once and you will hear “delete completed”, which indicate SMS number is deleted successfully. Operating method: [XX
] [#] XX indicates: address codes of message-receiving numbers from the first group to the third group [57
] ~ [59] For example: delete the first SMS user number from the system Operating method: [57
] [#]
ÖÖÖÖÖ
If you want to change the alarm attribute of defense zone, such as turn off the siren when system alarms, you can do it by defense zone programming. In setup state, first input [60
], then the defense zone number [01~99],
then input defense zone type [1~4
], then input defense zone location
number [1~8
], and then select siren on/off [0/1], at last press [#] to confirm. You will hear the main unit emit a long beep and a voice prompt “setting completed”. Operating method: [60
] [AA] [B] [C] [D] [#]
15. Delete SMS Receiving Number
1).SMS Notification for Arm/Disarm (Default: OFF)
In setup state, input the command 77 + [1/ 0] + # (1: ON, 0: OFF)
After starting this function, the system can send SMS to three SMS receiving
numbers (57~59 as mentioned above) when the system enters arm/ disarm
status through wireless remote controllers or its panel keyboard operation.
16. Defense Zone Programming
12
ÖÖ
For example: setup 13822222222 as the first SMS receiving number Operating method: [57
] [138222222] [#]
Functions Settings
Functions Settings
ЦЦЦЦЦ
C: defense zone location [1] SOS Alarm [2] Fire Alarm [3] Gas Leak Alarm [4] Door Alarm [7] Balcony Alarm D: siren ON/OFF: [0] OFF, [1] ON For example: set defense zone 12 to be 24-hour, fire alarm and siren on Operating method: [60
] [12] [3] [2] [1] [#]
If you want some detectors work and some do not, you can use [Home Arm
] function.
In setup state, use keypad to input [ 61
], then choose the corresponding
defense zone number [01~99], then choose [ Home Arm], and then
choose whether alarm [0/1] button, and finally press [ # ] to confirm. The main unit will make a long beep and a voice prompt “setting completed”.
ÖÖÖ
ÖÖÖ
ÖÖÖ
Operating method: [61
] [XX] [A] [#]
XX
indicates: [ 01~99 ] is defense zone 1 to defense zone 99
A
indicates: [0] Home arm but not alarm
For example: set defense zone 11 to be Home arm and alarm Operating method: [61
] [11] [1] [#] For example: set defense zone 12 as Home arm but not alarm Operating method: [61
] [12] [0] [#]
B:
defense zone type [1]: real-time defense zone [2]: 40 seconds delay defense zone [3]: 24 hours defense zone
AA
: defense zone number [01~99] means zone 1 to zone 99;
17. Home Arm Defense Zone Setting
[4]: bypass defense zone
[5] Hall Alarm
[6] Window Alarm
[8] Boundary Alarm
[1] Home arm and alarm
13
Functions Settings
Functions Settings
Ö
In setup state, use keypad to input [701
], and then press [#] to confirm. The main unit will emit a beep and the [ ] indicator is on, and after 10 seconds countdown, recording starts: record at 30cm away from the main unit with moderate tone; 10 seconds later, the main unit will make a beep indicating the recording stops and the recorded voice will replay. Operating method: [701
] [#]
LCD display:
Ö
ÖÖ
Ö
In setup state, use keypad to input [75
]; in the operation of arm/ disarm by remote control, select if the siren sounds or not by [0/1] button, and then press [#
] to confirm. The main unit will emit a long beep and a voice prompt “setting completed”. Operating method: [75
] [A] [#]
A indicates: [0
] Siren off; [1] Siren on; System default: [0] Siren off For example: set siren on when arm/ disarm Operating method: [75
] [1] [#]
LCD display:
ÖÖ
In setup state, use keypad to input [76
], and then [1/0], finally press [#] to confirm. The main unit will make a long beep and a voice prompt “setting completed”. Operating method: [76
] [A] [#] A indicates: [0]: siren off in “Emergency Help” mode [1]: siren on in “Emergency Help” mode System default: [0
] siren off
18. Voice Recording
19. Siren Setting
20. Siren Setting in “Emergency Help” mode
14
Functions Settings
Functions Settings
Arm: defense zone 1~99 will alarm when detectors are triggered Home Arm: in arm status, the defense zone which is set as [Home Arm] will alarm when detectors are triggered. Disarm: defense zone 1~99 will not alarm when detector triggered (except 24 hours defense zone) System setup status: In this status, all defense zones will not alarm when detectors are triggered.
Operation Instructions
Out Arm: Press button Disarm: Press button Home Arm: Press button Emergency Alarm: Press button, system will alarm at once.
It means, for the safety, while somebody is at home, you need to enable the peripheral door, window, balcony and boundary detectors of the alarm system while prevent from triggering the indoor detectors, which may cause improper warning; then, you shall select Arm at Home, let just part of the detectors work and disable the other parts.
Main Unit Operation: Press [At Home ] button on keypad Remote Control Operation: Press [ ] button on remote controller
LCD display:
1).
2).
3).
4).
1).
2).
3).
4).
ΚΜ
1. System status. There are 4 status as following
2. Remote Controller Operation
3. Home Arm
Users can use remote controller to set system as Out Arm, Home Arm, Emergency Alarm, Real-time Disarm and etc.
15
Functions Settings
Functions Settings
It means to guard all around your house while everyone is going out; all the detectors of the host are always working; when the detector is triggered by detecting source (anti-theft, fire prevention, gas leak, etc.), the alarm system will sound the alarm. Press [Out Home ] button on keypad, system will make a beep per second and totally 100 beeps. The [OUT ARM] indicator will be on without flashing. It means Out Arm is set successfully. Arm Operation: Press [Out Home ] button, the system will enter arm status 100 seconds later.
4. Out Arm
16
LCD display:
You can also set out arm by SMS remotely. The SMS command is: Remote Control Password (Default: 1234) + [1] After the setting, the host makes a "Di" sound, ARM LED is on and you will receive a SMS: System armed.
LCD display:
You can also set disarm by SMS remotely. The SMS command is: Remote Control Password (Default: 1234) + [2]
5. Disarm
It means to stop the alarm when the main unit sounds the alarm or make the alarm system in the state of non-warning. After disarming, even if you trigger the detector, the main unit would not sound alarm (excluding 24-hour defense areas). Use keypad to input system password, then press [#] button. [Out Home] or [At Home] lights will be off. It means disarm setting successful. Remote Control Operation: Press [ ] button on remote controller Main Unit Operation: input system password + [#]
Functions Settings
Functions Settings
17
After the setting, the host makes "Di" Di" sound, ARM LED is off and you will receive a SMS: System disarmed.
Note: If you send arm or disarm SMS by the mobile phone number stored
in the system before (refer to “SMS Receiving Number Setting), you will
receive two arm/disarm SMS.
When the main unit sounds alarm, it will dial the preset numbers. If no one
answers the call, the system will call the next user number automatically.
The system will call each preset numbers for 3 times in order.
If you answer the call, you will hear the pre-record voice. You can set system
via your telephone or mobile phone keypad.
If you hang-up directly without answering the call, the system will call each
preset number for 3 times circularly. Press [*]: Read the alarm information. Press [1]:
Main unit stops alarming and Arm; it stops calling users.
Press [2]: Main unit stops alarming and Disarm; it stops calling users.
Press [3]: Siren off and monitors the scene for 30 seconds; for continued
monitoring, press [3] again to monitor for another 30 seconds. Press [4]: Main unit starts a 30-second two-way intercom. It cannot be
controlled by the mobile during the time of intercom.
Dial the number associated to the alarm main unit by phone (mobile phone ), and after one ringing cycle, you can hear a voice prompt
“Please enter password”. If the password is right, you will here
“Press 1 to arm, Press 2 to disarm, Press 3 to Monitor, Press 4 to
Intercom”. If the password is wrong, you will hear a prompt voice
“wrong password, please re-enter”.
6. Answer Alarm Call
7. Remote Control
Functions Settings
Functions Settings
18
Press [1]: arm, if finished successfully, you will hear a voice prompt “System armed”. Press [2]: disarm, if finished successfully, you will hear a voice prompt “System disarmed”. Press [3]: monitoring for 30 seconds, to continue monitoring, press [3]
again to monitor for another 30 seconds. Press [4]: two-way intercom for 30 seconds. You can’t operate the main unit during this time.
Press [Emergency ] button on keypad, or [ ] button on remote controller
or wireless panic button, the main unit will alarm and make call to the preset
user numbers.
In disarm status, you can use the main unit to make any call just like a
land-line telephone. Dial telephone number on keypad, press [ ] button, the main unit will make a beep and the [ Signal ] indicator will be flashing.
After the call, press [ ] button again, the main unit will be in disarm status.
In disarm state, input [*0#], then the main unit will make a long beep and
enters the state of alarm record checking. After displaying the alarm and
defense zone number indicator, the LCD screen will display the exact alarming time of this defense zone. Press 2, you can upturn to check the previous alarming record; press 8, downturn to check; and press [*#] to exit checking.
8. Emergency Help
9. System Dialing Function
10. Alarming Record Checking
Functions Settings
Functions Settings
Ö
19
For example: the 51st defense zone; the 7th alarming; alarming time: 12:10,
August 1st, 2008. LCD display for one second, and then display the alarming
time:
You can also check the alarm records by SMS ( Max: Latest 9 records).
SMS Check Command: Remote Control Password (Default: 1234) + [3]
Reply SMS:
Eg: Alarm record:
NO1 Zone: 05 TIME: 11-06-25 11:37
(It indicates the first record: wireless zone 5 alarm time)…………….
NO9 Zone: 19 Time: 11-06-25 11:45
(It indicates the first record: wireless zone 19 alarm time)
Before installing the main unit, you should check the signal of the installing
place in order to ensure the unit can perform well. In setup state, input
[81
] #, the main unit will make a long beep and display 00 + XX ( XX
indicate s the intensity of the signal). And the intensity should be within
the range of 07-31; if it’s less than 07, you should change place.
For example: if the signal intensity is 12, it will display as:
Notes:
Only under Out Arm status, the system has the function of sending SMS
alert for power failure/ power recovery. While in Disarm or Home Arm
status, it does not. The SMS content: Power failure: Power charger off Power recovery: Power charger on
11. GSM Signal Checking
[ ]
Functions Settings
Functions Settings
20
Input Voltage
Standby Current
Alarming Current
Wireless Frequency
GSM Frequency
Back-up Battery
Siren Volume
DC12V/1A
<55mA
<450mA
3.`6:+<3œ
900/ 1800/ 1900MHz
NI-HI AAA*6 DC7.2V 110dB
List 2:
Defense Zone
Zone 1
Zone 2 Zone 3
Zone 4
Zone 5 Zone 6
Emergency button
Zone 7-99
Wired defense
`UTK
Operation Password
Remote control Password
Siren sound time
effective
effective
effective
effective
effective
effective
effective
effective
effective
effective
effective
effective
effective
effective
8888
1234
180sec
real-time
real-time real-time
real-time
real-time
real-time
24 hours 24 hours
24 hours
Remote control
Siren
Home Appliance
Balcony alarm
Fire alarm Gas alarm
Emergency alarm
Emergency alarm
Emergency alarm
yes
yes
yes
yes
yes yes
yes
yes
On
Off
no
Optional
Door alarm
Hall alarm Window alarm
Arm Home Arm
Type
invalid
invalid
invalid
invalid
Technical Parameters
[ ]
Technical Parameters
Technical Parameters
Alarm Information
Siren
List 1:
21
Siren
The alarm system has excellent design and uses advanced technologies.
It shall be used with care. The following suggestions are required to
maintain your obligations under the warranty terms, and for prolonging
the service life of the system.
Place the control panel and all parts and accessories out of children’s
reach.
Keep the alarm system dry. Rain, humidity and various fluids or moisture
all will corrupt the electronic circuit.
Do not use or place the alarm system in dirty locations,otherwise the
electronic elements will be damaged.
Do no place the system in excessively hot locations.
High temperature will shorten t he service life of electronic equipment,
damage batteries, deform or even melt some plastic parts.
Do not place the system in excessively cold locations.
Other wise condensation many occur and damage the
circuit board of the alarm system.
I
t is recommended that you check and test the alarm
system periodically:
Components list
[ ]
Components list
Care and Maintenance
[ ]
Care and Maintenance
Main panel Remote controller
PIR sensor
Door sensor Power adapter
User manual
1pc
1pc
1pc
1pc
2pcs
1pc
1pc
22
1. Trigger wireless detectors to see if system can alarm normally;
2. Check all detectors’ batteries to see if it’ in low voltage;
3. Check whether wireless detectors can send signal to the main unit normally.
1. Check the use of SIM card, such as network signal, balance, etc.
2. Make sure the PIN code verification of the SIM card is closed.
3. Please keep the password and SIM card number safe, in case that other people remote control the system illegally.
Since the alarm system is continuously in operation or standby mode,
the supply adaptor of the control panel shall be connected to a safe
and reliable socket.
Check the main unit every three months:
1. Whether it can arm/disarm normally;
2. Whether it can dial the number for alarm normally;
3. Whether it can receive wireless detectors’signal normally;
4. Whether the back - up battery can work normally.
Check the wireless detectors once a month:
Do not place the system near your bedroom or office table, because the
siren will make high-loudness sound in the case of alarm, which may
adversely affect your rest or work.
If the alarm system will not be used for a long time, please disconnect the
system from the power supply.
Please do not disassemble, repair or alter the products without permission,
or it may cause accidents and faults.
Care and Maintenance
Care and Maintenance
Check the SIM card:
s
23
Do not drop this product on the ground or on hard objects, as it may lead
to massive impact to cause faults and damages.
Without approval and consent of relevant authorities, please do not set “110”, “119” or the alarm phone number of police station for this
main unit.
Please read the suggestions above carefully and follow the instructions
herein. If any of the equipment does not work properly, please send it to
the dealer or authorized service point for repair. We will try our best to
solve the problem for you as soon as possible.
Care and Maintenance
Care and Maintenance
The Following Sensors Are Optional
24
Care and Maintenance
Care and Maintenance
Optional sensors/detectors are packed separately. They include remote controller, outdoor siren, transmitter, wireless PIR, wireless gap sensor, wireless gas detector, wireless smoke detector, panic button, baluster, etc. You can choose according to your specific requirements.
MOBILE CALL
GSM Alarm System
2011.12.V2.0
Loading...