IMPORTANT SERVICE SAFETY INFORMATION
Operating the receiver outside of its cabinet or with its back removed involves a shock hazard. Work on these
models should only be performed by those who are thoroughly familiar with precautions necessary when working on
high voltage equipment.
Exercise care when servicing this chassis with power applied. if carelessly contacted, can cause serious shock or
result in damage to the chassis. Maintain interconnecting ground lead connections between chassis, escutcheon, picture
tube dag and tuner when operating chassis.
When it is necessary to make measurements or tests with AC power applied to the receiver chassis, an Isolation
Transformer must be used as a safety precaution and to prevent possible damage to transistors. The Isolation
Transformer should be connected between the TV line cord plug and the AC power outlet.
It is important to maintain specified values of all components and anywhere else in the received that could cause
a rise in operating supply voltages. No changes should be made to the original design of the receiver.
Components shown in the shaded areas on the schematic diagram and/or identified by in the replacement parts
list should be replaced only with exact factory recommended replacement parts. The use of unauthorized substitute
parts man creates may create shock, fire, or other hazards.
Before returning the receiver to the user, perform the following safety checks:
1. Inspect all lead dress to make certain that leads are not pinched or that hardware is not lodged between the chassis
and other metal parts in the receiver.
2. Replace all protective devices such as non-metallic control knobs, insulating fish papers, cabinet backs, adjustment
and compartment covers of shields, isolation resistor-capacitor networks, mechanical insulators etc.
3. To be sure that not shock hazard exists, a check for the presence of leakage current should be made at each exposed
metal part having a return path to the chassis (antenna, cabinet metal, screw heads knobs and/or shafts, escutcheon,
etc.) in the following manner.
Plug the AC line cord directly into a 110V/220V/240V, AC receptacle. (Do not use an Isolation Transformer
during these checks.) All checks must be repeated with the AC line cord plug connection reversed. (If necessary, a
non-polarized adapter plug must be used only for the purpose of completing these checks.)
PLEASE READ BEFORE ATTEMPTING SERVICE
1. Use an Isolation Transformer when performing any service on this chassis.
2. Never disconnect any leads while receiver is in operation.
3. Disconnect all power before attempting any repairs.
4. Do not short any position of the circuit while the power is on.
5. For safety reasons, replace components any with identical replacement parts (SEE PARTS LIST).
6. Before alignment, warm up the TV for at least 30 minutes.
7. When removing a PCB or related component, after unfastening or changing a wire, be sure to put the
wire back in its original position.
8. Inferior silicon grease can damage IC's and transistors. When replacing IC's and transistors, use only
specified silicon grease. Remove all old silicon when applying new silicon.
9. Before removing the anode cap, discharge eletricity because it contains high voltage.
PDF 文件使用 "pdfFactory Pro" 试用版本创建www.fineprint.com.cn
A. SPECIFICATION
System : PAL I D/K B/G, SECAM D/K B/G L
Channel : VHF~ Low BAND : 0 CH(46.25MHz) ~S9 CH(161.25MHz)
VHF~ High BAND : S10 CH(168.25MHz)~S41 CH(463.25MHz)
UHF BAND : E21CH(471.25MHz)~E69 CH(855.25MHz)
PDF 文件使用 "pdfFactory Pro" 试用版本创建www.fineprint.com.cn
B. ADJUSTMENT MANUAL
Video Signal
ey of the remote controller 5 times in 3
will
een. Then push the
key to enter the factory setting
Video Signal
Pattern Generator
Pattern Generator
x:299
Pattern Generator
x:313
, Color bar and Gray
Ⅰ. TEST NOTE
1.Please follow the pointed test steps and choose the right test equipment to conduct
adjustment, otherwise good effect of Unit could not be obtained. The unit should be
warmed up for 30 minutes before adjustment and every parameter should be adjusted
repeatedly till the optimum value obtained, the pointed voltage value should be ensured
during test to get satisfied test result.
2. Test environment
1) Temperature : 15°C-35°C
2) Relative Humidity : 45-75%
3) Air pressure : 86-106KPa
3 Test equipments(The following equipment should be calibrated before testing)
1) Computer 1 set
2) Multi-meter (VICTOR VC9801) 1 set
3) Video Signal Generator (Chroma Model 2227/2327) 1 set
4) Color Analyzer (Chroma Model 7120 ) 1 set
5) DDC card (DYNACOLOR, INC D8330) 1 slice
6) TV Video Signal Generator (FLUKE PM54200) 1 set
Item Equipment Condition Adjust method
1. Enter the
adjust menu
2. Loading
default data
3.Color
temperature
adjust
a. Auto adjust Pattern Generator
b.9300K
c.7500K
TV
Generator
TV
Generator
Color analyzer
Color analyzer
Color analyzer
Gray
Gray “LOAD DEFAULT”
1280*1024 75HZ
Color bar
Full white pattern Adjust R.G.B data in factory status
Full white pattern Adjust R.G.B data in factory status
Power on the TV , push the “call”
K
seconds. The “ version xxxx”
display in the scr
“menu”
status.
“AUTO COLOR”
x:285 y:293 Y:160cd/m2
y:315 Y: 160cd/m2
d.6500K
4.TV setting
AFC setting
Color analyzer
TV Signal Generator
Full white pattern Adjust R.G.B data in factory status
y:329 Y: 160cd/m2
60dB
PDF 文件使用 "pdfFactory Pro" 试用版本创建www.fineprint.com.cn
Set “AFC” on
b. AGC adjust
Video Signal
picture
Function check
Signal
Color bar and
Power Lose
ake off the signal
or not
model
5. check the power loss is less than 5
function
ith DDC Card
VGA OR
TV
Generator
60dB , Color bar and Gray Adjusting the AGC data to make the