DRW170687AB
Multi Indicator
KN-2000W SERIES
I N S T R U C T I O N M A N U A L
Thank you very much for selecting KONICS products.
For your safety, please read the following before using.
Safety Considerations
Please keep these instructions and review them before using this unit.
※
※
Please observe the cautions that follow;
Warning
Caution
※
The following is an explanation of the symbols used in the operation manual.
Caution: Injury or danger may occur under special conditions.
Warning
1. In case of using this unit with machinery(E.g.: nuclear power control, medical
equipment, ship, vehicle, train, airplane, combustion apparatus, safety device,
crime/disaster prevention equipment, etc) which may cause damages to
human life or property, it is required to install fail-safe device.
Failure to follow this instruction may result in re,
2. Install this unit on a panel.
Failure to follow this instruction may result in electric shock.
3. Do not connect, repair, or inspect this unit when power is ON.
Failure to follow this instruction may result in electric shock.
4. Do not disassemble the case. Please contact us if it is required.
Failure to follow this instruction may result in electric shock or re.
5. Wire properly after checking terminal numbers.
Failure to follow this instruction may result in re.
Caution
1. This unit shall not be used outdoors.
Failure to follow this instruction may result in shortening the life cycle of the product
or electric shock.
2. Please observe the rated specications.
Failure to follow this instruction may result in shortening the life cycle of the product
or re.
3. In cleaning this unit, do not use water or organic solvent. And use dry cloth.
Failure to follow this instruction may result in electric shock or re.
4. Do not use this unit where there are ammable or explosive gas, humidity,
direct ray of the sun, radiant heat, vibration and impact etc.
Failure to follow this instruction may result in re or explosion.
5. Do not inow dust or wire dregs into the unit.
Failure to follow this instruction may result in re or malfunction.
6. Wire it properly after checking terminal numbers when connecting power
cable and measuring input.
Failure to follow this instruction may result in re or explosion.
Ordering Information
KN-2 0 0 0 W
1: For transmission output(4-20mA), select one between transmission output+alarm output 2 or
※
transmission output+alarm output 4.
※
The above specifications are subject to change without notice.
Serious injury may result if instructions are not followed.
Product may be damaged, or injury may result if instructions are not followed.
human injury or damage to property.
Size
W DIN W96×H48mm
Power supply
0 100-240VAC 50 to 60Hz
1 24VDC
0 No option
Option output
1 Transmission output (4-20mA)
4 RS485 communication output
Transmission output (4-20mA)
5
+ RS485 communication output
Alarm output
0 No alarm output
2 Alarm output: 2
4 Alarm output: 4
Item
KN-2 Multi Indicator
Connections
KN-20 W
RTD/TC/mV/±1V
-1~+10V
0~20mA
transmitter
KN-22 W
KN-24 W
F.G.
Unit Description
1
3
4 6
4.
key
: Used to enter parameter set mode, move to parameters, save SV and return to
RUN mode.
5.
, , key: Used to change parameter SV.
6.
D.IN3
: Press the
and keys for 3 sec at the same time, it operates the set function
(alarm clear, display hold, zero-point adjustment) at [DI-K] at program mode.
Dimensions
96
108
91
1.
Display part(red)
● Run mode: Displays current measurement value.
2
● Parameter set mode: Displays parameter and SV.
2.
Unit indicator: Displays the set unit.
5
3.
Alarm output indicator
: Turns ON when the alarm is ON.
48
10
90
● Panel cut-out
Min. 116
44.8
Min. 52
+0.6
0
92
(unit: mm)
+0.6
0
46
Input Type and Range
Input type
Thermo
-couple
※1
RTD
Analog
※
K(CA)
J(IC)
E(CR)
T(CC)
R(PR)
B(PR)*
S(PR)*
N(NN)*
C(W5)*
L(IC)*
U(CC)*
Platinel II*
Cu50Ω*
Cu100Ω*
JPt100Ω
DPt50Ω
DPt100Ω
Current
Voltage
0.00 - 20.00mA
4.00 - 20.00mA
-50.00 - 50.00mV
-200.0 - 200.0mV
-1.0000 - 1.0000V
-1.000 - 10.000V
Above input types which have the * mark are not displayed.
To display the above input types, supply the power with pressing the key.
Parameter
Input range(℃) Input range(℉)
-200.0 to 1350.0 -328 to 2462
TC-K
-200.0 to 800.0 -328.0 to 1472.0
TC-J
-200.0 to 800.0 -328.0 to 1472.0
TC-E
-200.0 to 400.0 -328.0 to 752.0
TC-T
TC-R
TC-B
TC-S
TC-N
TC-C
TC-L
TC-U
TC-P
Cu50
Cu10
JPt1
DPt5
DPt1
0.0 to 1750.0 32 to 3182
400.0 to 1800.0 752 to 3272
0.0 to 1750.0 32 to 3182
-200.0 to 1300.0 -328 to 2372
0 to 2300 32 to 4172
-200.0 to 900.0 -328.0 to 1652.0
-200.0 to 400.0 -328.0 to 752.0
0.0 to 1390.0 32 to 2534
-200.0 to 200.0 -328.0 to 392.0
-200.0 to 200.0 -328.0 to 392.0
-200.0 to 600.0 -328.0 to 1112.0
-200.0 to 600.0 -328.0 to 1112.0
-200.0 to 850.0 -328.0 to 1530.0
aMA1
aMA2
aMV1
aMV2
A-V1
19999 to 19999
(display range is variable
depending on decimal point position)
A-V2
Specications
Series KN-2000W
Power
supply
Allowable voltage range 90 to 110% of rated voltage
Power
consumption
Display method 4½-digit, 7-segment LED (selectable red, green, yellow) method
Character size W10×H17mm
Input type
Digital input
Sub
output
Display accuracy
Setting method Set by front keys or RS485 communication
Alarm output hysteresis Set ON/OFF interval (1 to 999-digit)
Sampling cycle Analog input: 100ms, temperature sensor input: 250ms
Dielectric voltage 2000VAC 50/60Hz for 1 min (between input terminal and power terminal)
Vibration
Relay
life
cycle
Insulation resistance Over 100MΩ (at 500VDC megger)
Noise immunity ±2kV the square wave noise (pulse width 1㎲) by noise simulator
Memory retention Approx. 10 years (non-volatile semiconductor memory type)
Environ
-ment
Approval
Weight
※
※
■
AC voltage 100-240VAC 50 to 60Hz
DC voltage 24VDC
AC voltage Max. 8VA
DC voltage Max. 3W
RTD JPt100Ω, DPt100Ω, DPt50Ω, Cu50Ω, Cu100Ω (5 types)
Thermocouple K, J, E, T, R, B, S, N, C (W5), L, U, PLII (12 types)
Analog
Alarm output
Transmission
output
Com. output RS485 (Modbus RTU)
2-point
4-point
Ambient temp. -10 to 50℃, storage: -20 to 60℃
Ambient humi. 35 to 85%RH, storage: 35 to 85%RH
※1
1: The weight includes packaging. The weight in parenthesis is for unit only.
Environment resistance is rated at no freezing or condensation.
Communication
●Voltage: ±1.0000V, ±50.00mV, ±200.0mV, -1.000-10.000V (4 types)
●Current: 4.00-20.00mA, 0.00-20.00mA (2 types)
●Contact input: max. 2kΩ in ON,Max. 90kΩ in OFF
●Non-contact input: residual voltage max. 1.0V in ON,
leakage current max. 0.03mA in OFF
●Outow current: approx. 0.2mA
●2-point: relay contact capacity 250VAC 3A 1c
●4-point: relay contact capacity 250VAC 1A 1a
ISOLATED DC4-20mA (PV transmission) load resistance max. 600Ω
±0.2% F.S. ±1-digit (25±5℃)
±0.3% F.S. ±1-digit (-10 to 20℃, 30 to 50℃)
In case of thermocouple and below -100°C input, [±0.4% F.S.]±1-digit
※TC-T, TC-U is min. ±2.0℃
0.75 mm amplitude at frequency of 5 to 55Hz (for 1 min) in each X, Y, Z
direction for 2 hours
Mechanical: min. 10,000,000,
Electrical: min. 100,000 (250VAC 3A resistance load)
Mechanical: min. 20,000,000,
Electrical: min. 500,000 (250VAC 1A resistance load)
Approx. 332g (approx. 200g)
Communication set [Program mode: ADDR, BAUD]
You can set communication address [ ADDR] and communication speed [ BAUD] for
RS485 communication.
■
Communication write enable/disable [Program mode: COmW]
You can set to enable [ EnA] or disable [ DIsA] or writing parameter setting by RS485
communication.
■
Communication manual
Refer to communication manual for RS485 communication.
Visit our web site (www.konics.com) to download communication manual and software
[Integrated device management program: DAQMaster].
■
Software [Integrated device management
program: DAQMaster]
Integrated device management program,
DAQMaster, is able to set and monitor parameters. It
is available only for RS485 communication models.
Item Minimum requirements
System
Operating
system
Memory 256MB or more
Hard disk More than 1GB of free hard disk space
VGA 1024×768 or higher resolution display
Others RS-232 serial port (9-pin), USB port
IBM PC compatible computer with Intel
Pentium Ⅲ or above
Microsoft Windows 98/NT/XP/Vista/7/8/10
Monitoring Mode
RUN mode
MODE
Press
key.
※
1
Alarm 1
value
Alarm 2
value
Alarm 3
value
Alarm 4
value
High peak
value
Low peak
value
S
AL1 09(9
MODE
S
AL2 09(9
MODE
S
AL3 00)1
MODE
S
AL4 00)1
MODE
S
hPEK ----
MODE
S
lPEK ----
MODE
※1: S:Press any key among the 1, 3, 4.
※2: 1: Moves digits / 4, 3: Changes SV.
※3: Press the
※After entering setting group, press the
no additional key operation in 30 sec, it returns to RUN mode.
※ : This parameter may or may not appear, depending on the
※
2
Set each alarm value; [
※
MODE
3
• Setting range
※
※
Displays high/low peak value.
※
※
■ Communication specifications
Item Specications
Com. method RS48 5 2-wir e half dup lex
Com.
speed(BPS)
Converter Convert er built i n RS232
Max.
connections
Com.
distance
Protocol Mo dbus 1.1 RTU
Parity None
Stop Bit 1-b it
Data length 8-bit
MODE
The value ashes twice and is saved. It moves to next parameter.
: Temperature sensor input → within temperature range
Analog input →
When alarm operation [
is no alarm [
parameters are not displayed.
For model with 2 alarm output (KN-22 W),
not
High/Low peak value is available only to check and initialize
it. (Refer to ‘ High/Low peak monitoring’ for initialization.)
Initial high/low peak is saved after 2 sec from supplying the
power.
key after checking/changing SV in each parameter.
other parameter set or model type.
※Displayed only for alarm output models.
L-SC
AT)_
displayed.
19200, 9 600 , 4800, 2400,
1200
32 units
Max. 120 0m (within 700 m
recommended)
MODE
key for 3 sec or there is
to
H-SC
AL-1
to
4] in program mode.
AL-
4] in program mode
AL-
AL-1
to
] or sensor break alarm [
], these
SBa_
AL3, AL4 are
Program Mode
RUN mode
Press
for 3 sec
Input type
Temperature
Front display
Low limit
input value
High limit
input value
Decimal
Low limit
scale value
High limit
scale value
4mA output
scale value
20mA output
scale value
Input and
transmission
extension
AL1 mode
AL2 mode
AL3 mode
AL4 mode
AL output
hysteresis
Input special
function
correction
Digital lter
Digital input
terminal
Digital input
Display color
display color
Sensor
address
IN-P aMA2
MODE MODE
UNIT ?C
unit
unit
point
output
Input
key
Alarm
break
alarm
output
Com.
Com.
speed
Com.
write
Lock
MODE
dUNT ?/O
MODE
L-RG 0$00
MODE
H-RG 2)00
MODE
dP )0
MODE
L-SC 00)0
MODE
H-SC 10)0
MODE
lOUT 00)0
MODE
hOUT 10)0
MODE
EX.I0 SP
MODE
AL-1
MODE
AL-2
MODE
AL-3
MODE
AL-4
MODE
A-HY 001
MODE
InSF
MODE
IN-B 0000
MODE
MAvF 04
MODE
DI-T HOLD
MODE
DI-K HOLD
MODE
CLOR RED GRN YELO R--G G--R
MODE
C-AL RRRR
MODE
BURN ON
MODE
ADDR 01
MODE
BAUD (6K
MODE
COmW EnA
MODE
LOCK OFF
MODE
MODE
key
※1
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
Select digital input function by no. 6 and 7.
※
S
Select digital input function by front keys.
※
※
S
Select display part color for RUN mode and error. ※Refer to ‘ Display color’.
S
S
S
S
S
S
※1: S:Press any key among the 1, 3, 4.
※2: 1: Moves digits / 4, 3: Changes SV.
※3: Press the
※After entering setting group, press the
※ : This parameter may or may not appear, depending on the
※2
Select input type. (Refer to ‘ Input Type and Range’.)
※3
3
4
3
4
Select front display unit.
Set low limit of input range.
• Setting range: within analog input type range
Set high limit of input range.
• Setting range: within analog input type range
3
4
Select decimal point position of display scale value.
Set low limit scale value.
• Setting range: -19999 to 19999
Set high limit scale value.
• Setting range: -19999 to 19999
Set output scale value for 4mA.
• Setting range: Temperature sensor input → within temperature range,
Set output scale value for 20mA.
• Setting range: Temperature sensor input → within temperature range,
3 3
4 4
Select extension range of 4-20mA input and transmission output.
AT!A
AT!A
AT@A
Set AL1 to
AL4 alarm
operation
and option
AT@A
※SV changing method of
※For model with 2 alarm output (KN-22 W),
※
No alarm [
※
Set alarm value [
Set alarm output hysteresis. • Setting range: 001 to 999
※
When alarm operation [ AL-1 to AL-4] in program mode is no alarm
[ AT)_] or sensor break alarm [ SBa_], this parameter is not displayed.
3
LIN ROOT SQAR TUF
4
Select input special function.
Set input correction value.
• Setting range: -999 to 999
Set the number of moving average digital lters.
• Setting range: 01 to 16
3
4
For the model without alarm output (KN-20 W), AlRE is not displayed.
3
4
Press the 4, 3 keys for 3 sec at the same time and it executes the selected function.
For the model without alarm output (KN-20 W),
3 3 3 3
4 4 4 4
Select display part color for alarm.
※Refer to ‘ Display color’.
3
4
Set communication address.
• Setting range: 01 to 99
3
4
Select communication speed (baud rate).
3
4
3
4
Select lock function.
MODE
The value ashes twice and is saved. It moves to next parameter.
no additional key operation in 30 sec, it returns to RUN mode.
key after checking/changing SV in each parameter.
MODE
key for 3 sec or there is
other parameter set or model type.
※
Displayed only when selecting
?F
※
Displayed only when selecting analog input type.
3
OFF
4
3
)00
4
※Displayed only for transmission output model.
Analog input → L-SC to H-SC
Analog input → L-SC to H-SC
※Displayed only when selecting analog input type.
temperature sensor input type.
3
?C
4
3
)000
4
?F
0
10P 0P
※Displayed only for alarm output models.
S
AL-1
MODE
AL-2
MODE
AL-3
MODE
AL-4
MODE
Next parameter
], sensor break alarm [
AT)_
AL1
※
ZERO
ZERO
OFF
※Displayed only for RS485 communication output model.
1(2K
DIsA
LOC1
<Alarm operation> <Alarm option>
AT!A
MODE
AT@A
SBa_
AT)_
to
AL-2
to
Displayed only when selecting analog input type.
3
4
3
4
3
4
※Displayed only for transmission output models.
Select output status when sensor disconnection.
3
4
Select enable/disable to communication write.
(EnA: enable to write, DIsA: disable to write)
3
4
is same as
AL-4
] do not have alarm option.
SBa_
] in monitoring mode.
AL4
3
4
AlRE
AlRE
AlREis not displayed.
※Displayed only for alarm output models.
3 3
4 4
LOC2
AT!A
AT!B
AT!C
AT!D
’s.
AL-1
AL3, AL4 are not displayed.
@4K $8K!2K
Functions
■ Alarm [ AL-1, AL-2, AL-3, AL-4]
This product has 2 or 4 alarms to operate individually when the value is too high or low.
Alarm function is set by the combination of alarm operation and alarm option.
To clear alarm, use digital input function (setting
power OFF and ON.
For the model (KN-20 W) without alarm output, these parameters are not
※
야DI-T, DI-K
as
AlRE
) or turn the
displayed.
AT!A
Alarm option
Alarm operation
Alarm operation
Mode Name Alarm operation Descriptions
ㅡ ㅡ
AT)_
High limit alarm
AT!
Low limit alarm
AT@
Sensor break alarm
SBa_
※
H: Alarm output hysteresis
Alarm option
OFF
High limt alarm
value: 800
ON
H
Low limt alarm
PV
value:200
ㅡ
℃
OFF
Option Name Descriptions
AT .A
Standard
alarm
If it is an alarm condition, alarm output is ON. Unless an alarm
condition, alarm output is OFF.
If it is an alarm condition, alarm output is ON. Before clearing
AT .B
Alarm latch
the alarm, an ON condition is latched. (Holding the alarm
output)
First alarm condition is ignored. From the second alarm
AT .C
Standby
sequence
condition, standard alarm operates.
When power is ON and it is an alarm condition, it is ignored.
From the second alarm condition, standard alarm operates.
If it is an alarm condition, it operates both alarm latch and
standby sequence.
When power is ON and it is an alarm condition, it is ignored.
From the second alarm condition, alarm latch operates.
AT .D
Alarm latch
and standby
sequence
■ Alarm output hysteresis [Program mode: ㅁA-HY]
Set the interval of ON/OFF alarm output.
The set hysteresis is applied to AL1 to AL4 and it is as below.
E.g.)
※
High limit
alarm value
: 4, high limit alarm value: 800, low limit alarm value: 200
A-HY
Low limit
:4
A-HY
800
800
ON
796
OFF
alarm value
■ High/Low peak monitoring [Monitoring mode: H.PEK, L.PEK]
This function is to save high/low peak to check the invisible abnormal condition of
system at [h PEK] or [ lPEK] in monitoring mode.
When the high/low peak is out of the temperature range, it displays HHHH or LLLL.
To initialize high/low peak, press the 3, 4keys at the same time for 3 sec at [hPEK]
or [lP EK].
In this case, peak value is the present input value.
■ Error
Display Descriptions Troubleshooting
Flashes when measured sensor
input is lower than the temperature
LLLL
range.
Flashes when measured sensor
input is higher than the temperature
HHHH
range.
Flashes when the sensor is break
BURN
or not connected.
Flashes when there is error to SV Check set conditions and re-set it.
ERR
■ User input range [Program mode: L-RG, H-RG]
When selecting analog input, you can set the input range for your purpose. Set low
limit input value [ L- R G ] and high limit input value [ H -RG] to limit the input range.
•Set conditions:
Low limit input value [ L-RG] +20%F.S. < High limit input value [ H-RG]
No alarm operation
ON
H
PV ≥ alarm temperature,
alarm is ON
PV
PV ≤ alarm temperature,
alarm is ON
℃
It will be ON when it detects
sensor disconnection.
Sensor break alarm does not
have alarm option.
A-HY
200
200
ON
204
OFF
When input is moved within the
temperature range, it is cleared.
Check temperature sensor connection.
■ Parameter initialization
To initialize all parameter as factory
default, supply the power to the product
with pressing the
the same time and it enters initialization
parameter.
MODE
and 1 keys at
Press the
at the same time.
MODE
+
1keys
Supply the power.
CLR
MODE
NO
Completes
initialization.
■ Input and transmission output extension [Program mode: ExIO]
This function is to extend analog input and 4 to 20mA transmission output to 5% or 10%
range.
Mode Operation
0P
Outputs 4 to 20mA within analog input range.
5P
Outputs 3.2 to 20.8mA for 5% out of the analog input range.
10P
Outputs 2.4 to 21.6mA for 10% out of the analog input range.
This parameter is displayed only for transmission output (4-20mA) model. But it is not
※
displayed when selecting temperature sensor input.
■ Input correction [Program mode: IN-B]
This function is to correct the error occurring from a thermocouple, a RTD or analog
input out of allowable error range of this unit.
This is also available to correct error when a sensor cannot contact the subject position
by calculating the error temperature.
Variable temperature sensors have accuracy level. Because high accuracy type is
expansive, standard thermocouples are generally used.
In this case, temperature sensor may occur error. By executing this function, you can get
more accurate temperature.
When executing input correction function, you should measure the error from a sensor
accurately. If the measured error is not correct, error may be greater.
(If
InSF= TUF, IN-B
function. Refer to ‘ Two unit function’.)
E.g.)When measured temperature is 4℃ and actual temperature is 0℃. Set
-4, and display value is 0℃.
■ Transmission output scale [Program mode: lOUT, hOUT]
For 4-20mA current output, this function is to set the display value for 4mA [ lOUT] and
the display value for 20mA [hOUT].
The inter val bet ween lOUTand hOUTis 10% F.S. If it is below 10%, it is xed as 10% of
SV.
Output
20mA
4mA
:4
lOUT
Relation among input range, user input range, display scale, and transmission scale
※
The below gure is the example for 4 to 20mA.
Input range
User
input range
Display scale
(display value)
Transmission
output scale
■ Two unit function [Program mode: TU F]
When connecting a pressure sensor, compound pressure which is below atmospheric
pressure (0) is for vacuum as mmHg and which is atmospheric pressure or over it is for
positive pressure as kg/cm2.
Atmospheric pressure is 0 kg/cm2. When this unit does not display 0 kg/cm2 , you can
correct zero-point adjustment function.
When using two unit function,
L-SC
parameter is displayed but you cannot set this. You can set
19999 range.
as atmospheric pressure input value not as input correction
Output
20mA
4mA
hOUT
LLLL HHHH
Display
4mA 20mA
L-RG= 6 H-RG= 16
L-SC= 0 H-SC= 1000
lOUT= 100 hOUT= 900
4mA
transmission
L-SC
Display
lOUT
is xed as -760.
hOUT
transmission
Display
20mA
H-SC
E.g.)When pressure range is 760.0 mmHg
to 3.000 kg/cm2 , and pressure transmitter
outputs 4-20mA, set the scale as H-SC:
3000, dP: )000
. This unit displays for
4mA input as -76)0, and for 20mA input
as #000.
Input
within 0 to
YES
IN - B
MODE
as
■
Display scale [Program mode: L-SC, H-SC]
For analog input, this function is to set (-19999 to 19999) for particular high/low limit value
in order to display high/low limit value of measurement input. If measurement inputs are ‘a’
and ‘b’ and particular values are ‘A’ and ‘B’, it will display a=A, b=B as below graphs.
Display
value
Display
value
Input
value
B
A
B
A
a b
a b
Display
value
Input
value
Display
value
b
Input
value
B
A
B
A
a b
Display
value
Input
value
Display
value
a b
A
B
Input
value
A
b
B
Input
value
Display scale function is able to change display value for max./min. measured input by
setting high limit scale [
E.g.) Set high/low scale value (input range is 0 to 10V)
※
• L-SC= )00
• H-SC= %00, 1)00, 1%00, `)00
Display
value
1%00
1)00
%00
0
`)00
] and low limit scale [
H-SC
• L-SC=1)00, H-SC= `)00
Display
value
1%00
1)00
Input
value
10V
`)00
] in program mode.
L-SC
• L-SC=-%00, H-SC= %00
Display
value
1%00
1)00
%00
Input
0
value
10V
-%00
0
10V
Input
value
※When changing input type, high/low scale is changed as factory default.
■ Input special function [Program mode: InSF]
When selecting analog input, this function is to display the calculated actual value by
square, root (√), or two unit function (TUF) as display value.
Parameter Functions Graph Applications
Display
LIN
ROOT
Outputs as input
value
Outputs the
rooted
Display
(√) input value
Outputs the
Display
SQAR
squared input
value
TUF
Refer to ‘ Two unit function’
※Display value and mA output value for
H-RG
L-RG
-
L-RG
Display value={( ) ×(
(output value)
Input value -
※Display value and mA output value for
-
L-RG
L-RG
Display value={( )×(
(output value)
Input value -
H-RG
Y = AX + B
Input
Y = A( X ) + B
(X ≥ 0)
Y=0(X < 0)
Input
Y = A(X)2 + B
(X > 0)
Input
Y = -A(X)
(X < 0)
SQAR
2
H-SC-L-SC
ROOT
H-SC-L-SC
Standard characteristics.
Input for linearity.
Used for measuring ows by
pressure signal.
Used for outputting differential
pressure by ow signal.
2
+ B
:
)}+
L-SC
:
)}+
L-SC
■ Digital filter [Program mode: MAvF]
Moving average digital lter is able to stably display and output the noise from input line
and irregular signals as software.
• Filter set range: 01 to 16
(When setting as 01, digital lter function does not run.)
Display cycle is same when executing moving average digital lter.
※
■ Digital input [Program mode: DI-T, DI-K]
By digital input terminal [ D I-T] (no. 6, 7 terminals) or digital input key [ D I- K ] (D.IN3:
for 3 sec), one of three functions executes as the below table.
4+3
Function Operaiton
When alarm is ON in RUN mode, it clears alarm forcibly. (It applies
only for alarm latch, alarm latch and standby sequence options.)
Alarm
AlRE
Alarm clear operates only when the value is out of the alarm value
clear
range. After clearing alarm, alarm operates its option normally.
※For the model without alarm output (KN-20 W), this parameter
is not displayed.
Display
HOLD
ZERO
Temporarily indicated value is stopped in order to check indicated
HOLD
value in unstable input.
Zero-
Set preset display value as 0.
point
This function is related with input correction [ IN - B]. When executing
adjust-
zero adjustment function in display value as 4, input correction value
ment
[IN - B] is set as -4 automatically.
■ Alarm output for disconnecting input sensor [Program mode: BURN]
When disconnecting input sensor, you can set the status of transmission output.
Parameter
BURN
SV Transmission output(4-20mA)
ON
20mA+5% output
OFF
4mA-5% output
■ Display color [Program mode: CLOR/ C-AL]
This function is to change display color for occurring error, operating alarm
automatically. User can check the status of this unit directly.
※
Color of monitoring mode, program mode is red.
RUN mode and error display color [Program mode:
ᜪ
Parameter Display color
SV RUN Error
RED
GRN
YELO
R--G
G--R
Alarm display color[Program mode:
ᜪ
Red Red
Green Green
Yellow Yellow
Red Green
Green Red
C-AL
]
CLOR
]
This parameter is displayed only for the alarm output models (KN-22 W,
KN24 W).
The number of set digit is same as the number of alarm output.
•
[2 alarm outputs (KN-22 W)]
[4 alarm outputs( KN-24 W)]
Set color for each alarm. It changes as R→ G → Y → R in turn.
•
E.g.)
※
When alarm is cleared, or two alarms operate at the same time, the latest alarm’s color is
•
AL-4 color
AL-3 color
AL-2 color
AL-1 color
S
S
S
S
S
:Press any one among the 1, 3, 4 keys.
RUN mode color is green.
① AL-1 is ON, display is green → yellow.
② AL-2 is ON, display is yellow → red.
③ AL-3 is ON, display is red → green.
④ AL-4 is ON, display is green → red.
applied.
When error occurs [
•
HHHH, LLLL, BU RN, ERR, E RR1
] during alarm, the set color of
CLO R
is applied.
■ Lock [Program mode: LOCK]
It limits to check parameter set value and to change it.
OFF LOC1 LOC2
Program mode
Monitoring mode
●: Enable to check/set, ◐: Enable to check, disable to set, ○: Disable to check
※
In
, only
LO C2
● ◐ ○
● ● ◐
parameter displays in program mode.
LO CK
Factory Default
■ Monitoring mode
Parameter Default Parameter Default Parameter Default
AL1 09(9 AL3 00)1 hPEK ---AL2 09(9 AL4 00)1 lPEK ----
■ Program mode
Parameter Default Parameter Default Parameter Default Parameter Default
IN-P aMA2 lOUT 00)0 InSF LIN ADDR 01
UNIT ?C hOUT 10)0 IN-B 0000 BAUD (6K
dUNT ?/O ExI0 5P MAuF 04 COMW EnA
L-RG 0$00 AL-1 AT!A DI-T HOLD LOCK OFF
H-RG 2)00 AL-2 AT!A DI-K HOLD
dP )0 AL-3 AT@A CLOR RED
L-SC 00)0 AL-4 AT@A C-AL RRRR
H-SC 10)0 A-HY 001 BURN ON
Cautions during Use
1. For connecting the power, use a crimp terminal (M3.5, max. 7.2mm).
2. The connection of this unit should be separated from the power line and high voltage
line in order to prevent inductive noise.
3. Install a power switch or a circuit breaker to supply or cut off the power.
4. Switch or circuit breaker should be installed nearby users for convenient control.
5. Do not use this unit near the high frequency instruments (high frequency welding
machine & sewing machine, large capacity SCR controller).
6. When supplying input, if HHHH or LLLL is displayed, measured input may have
problem. Turn off the power and check the line.
7. Installation environment
Indoors
①
Altitude max. 2,000m
③
※
It may cause malfunction if above instructions are not followed.
Major Products
Recorders
Indicators
Converters
Controllers
Thyristor units
Temperature sensors
Pressure transmitters
Temperature transmitters
Thermometers
Pressure gauges
Pollution Degree 2
②
Installation category
④
http://www.konics.com
Ⅱ
Controls & Measurement
Head ofce
37, Venture-ro, 36beon-gil, Yeonsu-gu, Incheon, Korea
TEL: 82-32-820-2400 / FAX: 82-32-813-9977
Sales Dept.
37, Venture-ro, 36beon-gil, Yeonsu-gu, Incheon, Korea
TEL: 82-32-820-2300 / FAX: 82-32-813-9981
E-mail: konics@konics.com
A/S center
37, Venture-ro, 36beon-gil, Yeonsu-gu, Incheon, Korea
TEL: 82-32-820-2356~7 / FAX: 82-32-813-9979
DRW170687AB