Graphic Imaging International 71 Charles St., Glen Cove, NY 11542
PHONE :(516) 674-2500 FAX :(516) 674-2727
Konica K21/28/34 Pre-Installation Information
To avoid waste of your production time as well as the time it will take for the engineer to install the
processor, please make sure that the requirements listed below are fulfilled before you schedule
the installation.
ENVIRONMENT AL REQUIREMENTS
Provide a heating and ventilating system capable of maintaining room temperature between 10° and 25°C
77°F) and relative humidity (RH) between 50% and 60%.
(50°-
WARNING! Never install the processor in explosive environments.
SP ACE REQUIREMENTS
Make sure that free space around the processor at the installation site will be approx. I m (3-4 ft) This makes
servicing possible, and allows you to pull out the trolley.
W A TER SUPPL Y
A water tap should be installed in the darkroom close to the installation site. Max. distance to the processor
should be 2
- 3 m (6 - 10 ft). The water hose is included with the installation kit.
DRAIN OUTLETS
The drain outlet should have a funnel shape to allow for proper drain line routing.
The recommended distance from the processor to the drain is 0.5 m
- max. 2 m (2 - 6 ft).
NOTE! Copper or brass should not be used in the drainage system as fixer containing silver might
attack it. Therefore plastic or rubber is recommended. Ask supplier of chemicals.
NOTE! If silver recovery is desired, the 25 mm (1”) drain hose from the fixer tank can be Connected
to a silver recovery unit.
CLEANING F ACILITIES
For cleaning purposes it would be convenient to have easy access to a water tap and a suitable sink, where
racks, rollers and guides can be washed and chemicals mixed.
POWER CONNECTIONS
If not already there, a main power outlet should be installed in the room, where the processor will be situated.
Max. recommended distance to the processor is 2 m (6 ft). The requirements are specified in the following
pages.
3/2001 K21/28/34 pre-installation info Page - 1 -
Technical Specification
3/2001 K21/28/34 pre-installation info Page - 2 -
3/2001 K21/28/34 pre-installation info Page - 3 -