CM-5
CM-5 Top-Port Spectrophotometer
offering versatile usage
and simple operation
Requirements for Colour measurement of Foods, Ingredients, Flavours & Fragrances, Drinks, Pharmaceuticals, Cosmetics and base Chemicals are especially demanding due to the extreme diversity of sample forms,
from solids to powders, granules paste, liquid to opaque, translucent or transparent, all forms are found.
An instrument capable of covering this wide range of products must not only be exible in terms of measurement methodology but even more importantly in terms of user friendliness and minimum sample preparation
time to allow fast routine measurements in the laboratory or in production control.
The new Konica Minolta Bench-Top Spectrophotometer CM-5 offers exactly this combination of versatility
and simplicity to cover all the requirements in a true “All in one” concept.
Full-featured
Stand alone instrument that
covers all your applications
The top-port concept allows easy sample positioning and measurement of solid samples. Just place
the sample on the measuring port and press the
measurement button.
Measuring areas with 30, 8 and 3 mm allow perfect
adaption to the sample size.
Samples in paste, powder or granule form can easily
be measured with the optional Petri-Dish set.
Simply sliding the top cover, opens the large transmission chamber to measure all kind of transparent liquids or solids, such as foils or glass plates in
Transmission mode.
Reflection measurement of solids Reflection measurement of paste products
For liquids, glass or plastic cells of up to 60 mm path
can be used, including 12.5 mm standard glass cells
when using the optional adapter.
Measurement of liquids in transmission
Measurement of solids in transmission

Functions & Features
that make your daily work
faster and easier
The large LCD screen show the measurement
results delete either numerically or graphically in-
cluding Reectance values, all colour systems and
PASS/FAIL evaluations.
To simplify the operation; the “Operation Wizard”
is a perfect step by step on screen user guide in 7
Languages to ease operation.
To simplify the use of the CM-5 by several people
in parallel, measurement data and instrument set-
tings can be saved on a USB stick.
In addition to the classic colorimetric evaluation
systems, the CM-5 offers measurement results of
liquids to be evaluated in terms of industry speci-
c indices (colour scales) such as Gardner, Iodine,
Hazen (APHA), European and US Pharmacopeia.
Spectrophotometer
Top 10 Features
1. High-end Spectrophotometer with wide wavelength range
2. Top-port concept for Reectance measurements
3. Large Transmission chamber for liquids & solids
4. Stand alone function with LCD Screen and Firmware
5. Measurement of Industry specic indices
6. Storage of user settings and data on USB stick
7. “Operation Wizard” with real time on screen user guidance
8. Firmware in 7 Languages
9. Extremely easy operation with automatic calibration
10. Compact, lightweight and functional Design

Specications Spectrophotometer CM-5
Standard
accessories
Optional
accessories
Spectrophotometer
CM-5
Target Mask (Ø3 mm)
CM-A195
Petri Dish Measurement
Set
Target Mask (Ø8 mm)
CM-A196
Target Mask (Ø30 mm)
CM-A197
Transmittance Mask
CM-A200
(Ø20 mm)
Dust Cover
CM-A191
CM-S100w
Cell
CM-A98
(10 mm)
Cell
CM-A97
(2 mm)
Cell
CM-A99
(20 mm)
Plastic Cell
CM-A132
(20 mm; 100 pcs.)
Specimen Viewing Mirror
CM-A202
Connecting Cable CM-A58
USB Cable (2 m) IF-A19
AC Adapter
Plastic Cell
CM-A131
(10 mm; 100 pcs.)
Plastic Cell
CM-A130
(2 mm; 100 pcs.)
Personal computer
(Commercial product)
Data printer
(Commercial product)
CM-A205
Transmittance
Measurement Set
•
White Calibration Plate CM-A210
(with CD-ROM containing calibration data and data-setting software)
•
Zero Calibration Box CM-A124
•
Target Mask (for Petri Dish) CM-A203
•
Petri Dish CM-A128
•
Calibration Glass (for Petri Dish)
CM-A212
•
Accessory Case CM-A193
CM-A206
•
Transmittance Zero Calibration Plate
CM-A213
•
Transmittance Specimen Holder
CM-A96
• Transmittance Specimen Holder
Attachment CM-A199
• Accessory Case CM-A193
10 mm Cell
Measurement Set
10 mm-wide cell
(Commercial product)
CM-A207
•
Transmittance Specimen
Holder (10 mm)
CM-A198
•
Transmittance Zero Calibration
Plate (10 mm)
CM-A204
Illumination/viewing system
Integrating sphere size
Detector
Spectral separation device
Wavelength range
Wavelength pitch
Half bandwidth
Measurement range
Light source
Measurement time
Measurement/ illumination area
Repeatability
Inter-instrument agreement
Transmittance chamber
Display
Display languages
White calibration
Interfaces
Observer
Illuminant
Displayed data
Color space
Index
User index
Color-difference equation
Pass/fail judgment
Storable data
USB memory stick storage
Power
Size
Weight
Operating temperature/humidity range
Storage temperature/humidity range
Reflectance:
Transmittance: di:0°, de:0° (diffuse illumination: 0° viewing)
Ø152 mm
Dual 40-element silicon photodiode arrays
Planar diffraction grating
360 nm to 740 nm
10 nm
Approx. 10 nm
0 to 175 % (Reflectance or transmittance); Output/display resolution: 0.01%
Pulsed Xenon lamp
Approx. 1 s (to data display/output); Minimum measurement interval: Approx. 3 s
Reflectance: Changeable by changing mask and settings. LAV: Ø30 mm / Ø36 mm; MAV (optional): Ø8 mm / Ø11 mm; SAV (optional): Ø3 mm / Ø6 mm
Transmittance: Ø20 mm
Spectral reflectance: Standard deviation within 0.1% (400 nm to 740 nm) / Chromaticity value: Standard deviation within ΔE*ab 0.04
* When a white calibration plate is measured 30 times at 10-second intervals after white calibration
Within ΔE*ab 0.15 (Typical) I (Based on 12 BCRA Series II color tiles compared to values measured with a master body at 23°C)
No sides (unlimited sample length); Depth (maximum sample thickness): 60 mm
Sample holder (optional) for holding sheet samples or containers of liquid samples can be installed/removed
14.5 cm TFT color LCD
English, Japanese, German, French, Italian, Spanish, Simplified Chinese
Automatic white calibration (reflectance) / 100% calibration (transmittance) using internal white calibration plate
USB 1.1 (Connection to PC; USB memory stick); RS-232C standard (Connection to serial printer)
2° Standard Observer or 10° Standard Observer
A, C, D50, D65, F2, F6, F7, F8, F10, F11, F12, ID50, ID65 (simultaneous evaluation with two light sources possible)
Spectral values, spectral graph, colorimetric values, color-difference values, color-difference graph, pass/fail judgment, pseudo color, color assessment
L*a*b*, L*C*h, Hunter Lab, Yxy, XYZ, Munsell, and color differences in these spaces (except for Munsell)
Reflectance: MI; WI (ASTM E 313-73, ASTM E 313-96); YI (ASTM E 313-73, ASTM E 313-96, ASTM D 1925); ISO Brightness, B (ASTM E 313-73)
Transmittance: Gardner, Iodine, Hazen (APHA), European Pharmacopoeia, US Pharmacopeia
User-defined index
ΔE*ab (CIE 1976), ΔE*94 (CIE 1994), ΔE00 (CIE 2000), ΔE (Hunter), CMC (l: c)
Tolerances can be set to colorimetric values (except Munsell), color-difference values, or reflectance index values
Sample data: 4,000 measurements; Target color data: 1,000 measurements
Storage of measurement data and target color data. Storage/reading of measurement condition settings (Security-en-abled USB memory sticks cannot be used.)
AC 100 to 240 V, 50/60 Hz (using exclusive AC adapter)
Slide cover closed: 385 (W) × 192 (H) × 261 (D) mm I Slide cover open: 475 (W) × 192 (H) × 261 (D) mm
Approx. 5.8 kg
13 to 33°C, relative humidity 80 % or less (at 35°C) with no condensation
0 to 40°C, relative humidity 80 % or less (at 35°C) with no condensation
di:8°, de:8° (diffuse illumination: 8° viewing) / SCI (specular component included)/SCE (specular component excluded) switchable
Conforms to CIE No. 15, ISO 7724/1, ASTM E 1164, DIN 5033 Teil 7, and JIS Z 8722 (Condition c)
< System Configuration >
SAFETY PRECAUTIONS
For correct use and for your safety, be sure to read the instruction manual before using
the instrument.
- Specifications and appearance subject to change without notice.
- Company names and product names herein are trademarks or registered trade marks of their respective companies.
- The specifications and drawings given here are subject to change without prior
notice.
- If you have any questions about specifications, please contact your Konica Minolta
representative.
Konica Minolta Sensing, Inc. Osaka, Japan
Konica Minolta Sensing Americas, Inc. New Jersey, U.S.A. Phone: 888-473-2656 (in USA),
201-236-4300 (outside USA)
Konica Minolta Sensing Europe B.V. European Headquarter/BENELUX Nieuwegein, Netherland Phone: +31(0)30 248-1193 Fax: +31(0)30 248-1280
German Office München, Germany Phone: +49(0)89 4357 156 0 Fax: +49(0)89 4357 156 99
French Office Roissy CDG, France Phone: +33(0)1 493-82519 Fax: +33(0)1 493-84771
UK Office Milton Keynes, United Kingdom Phone: +44(0)1908 540-622 Fax: +44(0)1908 540-629
Italian Office Milan, Italy Phone: +39 02 39011.425 Fax: +39 02 39011.223
Swiss Office Dietikon, Switzerland Phone: +41(0)43 322-9800 Fax: +41(0)43 322-9809
Nordic Office Västra Frölunda, Sweden Phone: +46(0)31 7099464 Fax: +46(0)31 474945
Austrian Office Wien, Austria Phone: +43(0)1 87882-430 Fax: +43(0)1 87882-431
Polish Office Wroclaw, Poland Phone: +48(0)71 33050-01 Fax: +48(0)71 734 52 10
Distribuidor para España y Portugal AQUATEKNICA S.A. Valencia, Spain Phone: +34 963 30 20 13 Fax: +34 963 30 03 96
Konica Minolta (CHINA) Investment Ltd. SE Sales Division Shanghai, China Phone: +86-021-5489 0202 Fax: +86 -021-5489 0005
SE Beijing Office Beijing, China Phone: +86-010-8522 1551 Fax: +86-010-8522 1241
SE Guangzhou Office Guangzhou, China Phone: +86-020-3826 4220 Fax: +86-020-3826 4223
Konica Minolta Sensing Singapore Pte Ltd. Singapore Phone: +65 6563-5533 Fax: +65 6560-9721
Konica Minolta Sensing, Inc. Seoul Office Seoul, Korea Phone: +82(0)2-523-9726 Fax: +82(0)2-523-9729
©2009 KONICA MINOLTA
• Always connect the instrument to the specified power
supply volta ge. Improper connection may cause a fire
or electric shock.
• Be sure to use the specified batteries. Using improper
ba tteries may cause a fire or electric shock.
www.konicaminolta.eu
Certificate No: YKA 0937 154
Registration Date:
March 3, 1995
Certificate No: JQA-E-80027
Registration Date:
March 12, 1997