POLYVAC 30/50 - Standard units with Gaylord height stand and dust collection Fig. 1
3
All instructions refer to Figure 1 on page 2
For proper assembly, follow steps listed below.
a: Mount the Polyvac unit (1) on the stand (2) using
U-bolts (13), at washers (14) and lock nuts (15).
Make certain that the foundation is secure, and check regularly that all the mounting
bolts are tight.
b: Attach the lter manifold support arm (3) on the
stand (2).
c: Attach rst the OK160/200 transition (10) to blower
outlet with OK160 clamp (12). Then mount 45° bend (8), OK200 pipe (9), and again a 45° bend (8) using OK200 clamps. Attach the 4 bags manifold (4) on the support arm and clamp it to the bend (8).
d: Place drum (7) with lid (6) under the 4-bag manifold
and installs the four lter socks (5). The lter socks are slid over the OK adapters on drum lid and manifold and secured with OK200 clamps. Make
sure there is approximately 1 inch of material slid through the clamp.
List of Equipment
15 8 600366003 5/16" Lock-nut
14 8 100331014 M8 Flat Washer - Plated
13 4 600373028 5/16" x 2-1/2" x 60mm U-bolt
12 1 122000800 OK160 Quick Release Clamp, galv.
11 12 122050101 OK200 Quick Release Clamp, grey
10 1 121000367 OK160/OK200 Transition, grey
9 1 122000455 OKD200 x 0.15m Pipe, grey
8 2 122050115 45" OK200 Bend, galv.
7 1 699114492 45 Gallon Drum w. Window
6 1 699114237 4 x OK200 Inlet Drum Lid.
5 4 699114055 OK200 x 2m Filter Sock
4 1 699114441 4 Bag Manifold w. Side Inlet
3 1 699115792 Polyvac 4 Bag Manifold Bolt-on Stand
2 1 699115160 Polyvac Stand
1d 1 123110003 Polyvac 50, 5hp, 3ph, 575V-60Hz
1c 1 123110002 Polyvac 50, 5hp, 3ph, 460V-60Hz
1b 1 123110001 Polyvac 30, 3hp, 3ph, 575V-60Hz
1a 1 123110000 Polyvac 30, 3hp, 3ph, 460V-60Hz
4
POLYVAC 30/50 - Standard Units with Suction Flexhose Fig. 2
5
All instructions refer to Figure 2 on page 4
a: Rotate the Cyclone Inlet (Item A) for the best work-
ing position of the Suction Flex hose. Loosen, but
do not remove, the clamps on both top and bottom
of the cyclone. Rotate the cyclone to the desired
position, retighten the clamps.
b: Install the 4" Suction Flex hose. (Item C) First the
OK160 (6") to OK100 (4") adapter (Item B) must be clamped to the cyclone. The Flex hose is then con­nected with the OK100 (4") quick clamp.
c: Install the Suction Wand (Item D) to the Flex hose.
Make sure the air intake and handle are located at
the end nearest the hose.