Kollmorgen AKD2G-S Series, AKD2G Series, AKD2G-S-7V03, AKD2G-S-7V12, AKD2G-S-6V03 Product Safety Manual

...
AKD®2G-Sxx
Product Safety Guide
Edition: -, Beta, December 2018 Valid for AKD2G, Hardware Revision A Part Number 907-200024-99
English Deutsch Français Italiano Português Español Русский 中 国
Forsafe and proper use, follow these instructions. Keepthem for futurereference.
Beta Drives: Approvals (CE, Functional Safety, UL) are pending.
Record of Document Revisions
Revision Remarks
...
Table with lifecycle informationof this document see (# 75)
Beta, 12/2018 Beta edition

Contents

Product Safety Guide English (# 3) Product Safety Guide Português (# 49) Product Safety Guide Deutsch (# 25) Product Safety Guide Español (➜ # 50) Product Safety Guide Français (# 47) Product Safety GuideРусский (# 51) Product Safety Guide Italiano (# 48)
Product Safety Guide 中国
(# 52)
Appendix/Electrical Data (# 54) Appendix/Dimensions (# 60) Appendix/Connection Overview (# 61) Appendix/Approvals (➜ # 74)
Hardware Revision (HR)
AKD2G Firmware Workbench KAS IDE Remarks
A from 02-00-00-000 from 2.00.0.0000 from 3.01 Beta revision
Technical changes which improve the performance of the device may be made without prior notice!
This document is the intellectual property of Kollmorgen. All rights reserved. No part of this work may be reproduced in any form (by photocopying, microfilm or any other method) or stored, processed, copied or distributed by electronic means without the written permission of Kollmorgen.
Technische Änderungen zur Verbesserung der Leistung der Geräte ohne vorherige Ankündigung vorbehalten.
Dieses Dokument ist geistiges Eigentum von Kollmorgen. Alle Rechte vorbehalten. Kein Teil dieses Werkes darf in irgendeiner Form (Fotokopie, Mikrofilm oder in einem anderenVerfahren) ohne schriftliche Genehmigung von Koll­morgen reproduziert oder elektronisch verarbeitet, vervielfältigt oder verbreitet werden.
Sous réserve de modifications techniques apportés en vue d'amélioration des appareils!
Ce document est la propriété intellectuelle de Kollmorgen.Tous droits réservés. Sans autorisation écrite de l'entreprise Kollmorgen, aucune partie de cet ouvrage n'a le droit d'être ni reproduite par des moyens quelconques (impression, photocopie, microfilm ou autre procédure) ni traitée, polycopiée ou distribuée électronique.
Il produttore si riserva la facoltà di apportare modifiche tecniche volte al miglioramento degli apparecchi
Questo documento è la proprietà intellettuale di Kollmorgen. Tutti i diritti riservati. Nessuna parte del documento può essere riprodotta in qualsiasi forma (fotocopia, microfilm o altro processo) senza l’approvazione scritta della ditta Koll­morgen o rielaborata, riprodotta o diffusa mediante l’uso di sistemi elettronici.
Alterações técnicas que melhoram o desempenho do dispositivo podem ser feitos sem aviso prévio!
Este documento é uma propriedade intelectual da Kollmorgen. Todos os direitos reservados. Nenhuma parte deste trabalho pode ser reproduzida sob qualquer forma (por fotocópia, microfilme ou qualquer outro método) ou armazenado, processado, copiado ou distribuído por meios eletrônicos sem a permissão escrita da Kollmorgen.
Los cambios técnicos que mejoran el rendimiento del dispositivo pueden llevarse a cabo sin aviso previo.
Este documento es propiedad intelectual de Kollmorgen. Todos los derechos reservados. Ninguna parte de esta obra, bajo concepto alguno, podrá reproducirse (por fotocopia, microfilm ni ningún otro método) ni almacenarse, pro­cesarse, copiarse ni distribuirse por medios electrónicos sin el permiso por escrito de Kollmorgen.
Сохраняется право внесения технических изменений с целью усовершенствования приборов!
Настоящий документ является интеллектуальной собственностью Kollmorgen. Все права защищены. Воспроизведение любой части данного издания в любой форме (фотокопия, микрофильм или иной метод) или редактирование, размножение или распространение с помощью электронных систем без письменного разрешения компании Kollmorgen запрещаются.
如有提升设备性能的技术变更,恕不另行通知! 本文档知识产权归 Kollmorgen 所有 。版 权所 有 。未 经 Kollmorgen 书面许可,不得以任何形式( 利 用 影 印 、缩 微 胶
片或任何其他方法) 复 制 本 文 档 的 任 何 部 分 ,也 不 得 利 用 电 子 手 段 存 储 、处 理 、复制或分发本文 档 的 任 何 部 分 。
2 Kollmorgen | kdn.kollmorgen.com | Beta, December 2018
AKD2G Product Safety Guide | 1 English

1 English

1.1 General 4
1.1.1 Notes for the PrintedEdition (paper version) 4
1.1.2 Symbols Used 5
1.1.3 Abbreviations Used 6
1.2 Product Safety 7
1.2.1 You should pay attention to this 7
1.2.2 Use as Directed 9
1.2.3 ProhibitedUse 10
1.2.4 Warning note labels 11
1.3 Product life cycle handling 12
1.3.1 Transport 12
1.3.2 Packaging 12
1.3.3 Storage 12
1.3.4 Installation, setup and normal operation 13
1.3.5 Decommissioning 13
1.3.6 Maintenance and cleaning 13
1.3.7 Disassembly 13
1.3.8 System Repair 14
1.3.9 Disposal 14
1.4 Technical description and general data 15
1.4.1 Drive part number scheme 15
1.4.2 PackageSupplied 16
1.4.3 Ambient Conditions, Ventilation, andMounting Position 16
1.4.4 Electrical Data 17
1.4.5 Display, B1/2 push-buttons, S1/2 rotary switches 17
1.4.6 Fault and Warning Messages 18
1.5 Functional Safety 19
1.6 Mechanical Installation 20
1.7 Electrical Installation 21
1.8 Setup 22
1.9 Troubleshooting the AKD2G 24
Kollmorgen | kdn.kollmorgen.com | Beta, December 2018 3
AKD2G Product Safety Guide | 1 English

1.1 General

This guide presents the relevant information forsafe installation andsetup of the AKD®2G series of digital drives with functional safety support. This guideis valid for AKD®2G single axis drive or dual axis drive with 110V to 240V or 240V to 480V mains voltage.
Ouput stages: 3 A, 6 A, 12A rated current Programmability options: Base drive or Position Indexer drive Connectivity options: analog, CANopen, EtherCAT I/O options: Extended I/O (X22), 2ndFeedback&EEO (X23) Functional Safety options:
safety option 1 (SIL2 PLd) with STO or safety option 2 (SIL3 PLe) with STO, SS1-t, SBC, SDB and SBT or safety option 3 (SIL3 PLe) with STO, SS1-t, SS1-r, SS2, SLS, SSM, SSR, SDI, SLA, SAR, SLI, SLP, SCA, SBC, SDB and SBT.
Forfull informationrefer to additional Kollmorgendocuments for the AKD2G series of drives:
Installation Manual (PDF format): This manual provides instructions for installationand drive setup. Accessories Manual (PDF format): It provides informationfor accessories like cables andregen resistors used with AKD2G. Regional variants of this manual exist. CAN-BUS Communication (PDF format): Describes how to use your drive in CANopen applications. EtherCAT Communication (PDF format): Describes how to use your drive in EtherCAT applications. WorkBench Online help (HTML5 format): Describes how to use your drive in common applications. It also provides tips for max­imizing yoursystem performance with the AKD2G. The online help includes the Para- meter and Command Reference Guide which provides information for the parameters and commands used to program the AKD2G.
Beta Drives:
Approvals (CE, Functional Safety, UL) are pending. All documents are in preliminary.
These documents can be found on the DVD in the drive package. All documents can be downloadedfrom the Kollmorgen website www.kollmorgen.com.

1.1.1 Notes for the Printed Edition (paper version)

A printed version of the manual is enclosed with each product. For environmental reasons, the document was reduced in size and prin­ted on DINA5.
Shouldyou experience difficulties reading the font size of the scaled-down printed version, you can print and usethe PDF ver­sionin DINA4 format 1:1. Youcan find the PDFversion on the DVD accompanying the product and on the Kollmorgen website.
4 Kollmorgen | kdn.kollmorgen.com | Beta, December 2018

1.1.2 Symbols Used

Symbol Indication
DANGER
Indicates a hazardous situation which, if not avoided, will res­ult in death or serious injury.
AKD2G Product Safety Guide | 1 English
WARNING
CAUTION
Indicates a hazardous situation which, if not avoided, could result in death or serious injury.
Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
Indicates situations which, if not avoided, could result in prop­erty damage.
This symbol indicates important notes.
Warning of a danger (general). The type of danger is specified by the text next to the symbol.
Warning of danger from electricity andits effects.
Warning of danger from hot surface.
Warning of danger from suspended loads.
Warning of danger from automatic start.
Kollmorgen | kdn.kollmorgen.com | Beta, December 2018 5
AKD2G Product Safety Guide | 1 English

1.1.3 Abbreviations Used

Abbreviation Meaning
(# 53) "see page 53" in this document Ω Ohms A#, AXIS# A# or AXIS# are placeholders for the axis number. Used with keywords or
signal names AGND Analog ground AMSL Above meansealevel Axis Depends on context, eitherone AKD2G output stageor one loadaxis of
the full motion system. CAT Category CE Communité Européenne COM Serial interface for a personal computer DGND Digital ground EEPROM Electrically erasable programmablememory EEO EmulatedEncoder Output EMC Electromagnetic compatibility EMF Electromagnetic force F-SMA Fiber optic cableconnector according to IEC 60874-2 FSoE Fail safe over EtherCAT KAS Kollmorgen AutomationSuite KAS IDE Setup software (Kollmorgen Automation Suite Integrated Development
Environment) KDN Kollmorgen Developer Network LED Light-emitting diode LSB Low significant byte (or bit) MSB Main significant byte (orbit) NI Zero pulse OSSD Output Signal Switching Device PC Personal computer PE Protective earth PELV Protective Extra Low Voltage PLC Programmable logic control PWM Pulse-width modulation RAM Random access memory (volatile memory) RBrake/RB Regenresistor (also called a brake resistor) RBext External regenresistor RBint Internal regen resistor RCD Residual current device RES Resolver S1 Continuous operation tbd To be discussed (inprocess) VAC Volts, alternating current VDC Volts, direct current
6 Kollmorgen | kdn.kollmorgen.com | Beta, December 2018

1.2 Product Safety

1.2.1 You should pay attention to this

Specialist staff required!
Only properly qualified personnel are permitted to perform such tasks as transport, install­ation and setup. Qualified specialist staff are persons with expertise in transport, installation, assembly, commissioning and operation of electrotechnical equipment.
Transport, storage, unpacking: only by personnel with knowledge of handling elec­trostatically sensitive components. Mechanical installation: only by personnel with mechanical expertise. Electrical installation: only by personnel with electrotechnical expertise. Basic tests / setup: only by personnel with expertise in electrical engineering and drive technology.
The qualifiedpersonnel must know andobserve ISO 12100 / IEC 60364 / IEC 60664and national accident prevention regulations.
Read the documentation!
Read the availabledocumentation beforeinstallation and commissioning. Improperhandling of the devices can cause harm to people ordamage to property. The operator of systems using the drive system must ensurethat all personnel who work with the drive readand under­stand the manual before usingthedrive.
AKD2G Product Safety Guide | 1 English
Check Hardware Revision!
Check the HardwareRevision Number of the product (seeproduct label). This numberis the link between your product and the manual. The product HardwareRevision Number must match the Hardware Revision Number on thecoverpage of the manual.
Pay attention to the technical data!
Adhereto the technical data and the specifications on connection conditions. If permissible voltage values or current values are exceeded, the devices can be damaged. Unsuitable motoror wrong wiring will damage the system components. Check the combination of drive andmotor. Compare the rated voltageandcurrent of the units.
Perform a risk assessment!
The manufacturerof the machine must generate a risk assessment for the machine, andtake appropriate measures to ensure that unforeseenmovements cannot cause injury or damage to any person orproperty. Additional requirements onspecialist staff may also result from the risk assessment.
Automatic restart
The drive might restart automatically after power on, voltage dipor interruption of the supply voltage, depending ontheparametersetting. Risk of death orserious injury for humans work­ing in the machine.
If the parameterAXIS#.ENDEFAULT is set to 1, then place a warningsign to the machine (Warning: Automatic Restart at Power On)and ensure, that power onis not possible, while humans are in a dangerous zone of the machine. In case of using anundervoltage protection device, you must observe EN 60204-1:2006 chapter 7.5 .
Kollmorgen | kdn.kollmorgen.com | Beta, December 2018 7
AKD2G Product Safety Guide | 1 English
Observe electrostatically sensitive components!
The devices contain electrostatically sensitive components which may bedamaged by incor­rect handling. Electrostatically discharge your body before touching the device. Avoid con­tact with highly insulatingmaterials (artificial fabrics, plastic film etc.). Place the device on a conductive surface.
Hot surface!
Drives may have hot surfaces during operation. The housing can reach temperatures above 80°C. Risk of minorburns! Measure the temperature, and wait until the housing has cooled down below 40 °C before touching it.
Earthing!
It is vital that you ensure that the drive is safely earthed to the PE (protective earth) busbarin the switch cabinet. Risk of electric shock. Without low-resistance earthing nopersonal pro­tection can be guaranteed.
Leakage Current!
Since the leakage current to PE is more than 3.5 mA, in compliance with IEC61800-5-1 the PE connection must either bedoubledor a connecting cable with a cross-section >10 mm² must be used. Deviating measures accordingto regional standards might be possible.
High voltages!
The equipment produces highelectric voltages up to 900 V. Lethal dangerexists at live parts of the device. Do not open or touch the equipment during operation. Keepall covers and cab­inet doors closed. Built-in protection measures such as insulation orshieldingmay not be removed. Work on the electrical installation may only be performedby trained and qualified personnel, in compliance with the regulations for safety at work, and only with switched off mains supply, and secured against restart.
Never undo any electrical connections to the drive while it is live. There is a danger of elec­trical arcingwith damageto contacts andpersonal injury. Wait at least 5 minutes after dis­connecting the drive from the main supply powerbefore touching potentially live sections of the equipment (such as contacts) or removing any connections.
Always measure thevoltage in the DC bus link andwait until the voltage is below 50 V before handling components.
Functional Safety!
Beta drives: Safety functionality is not approvednor certified. Do not use this functionality in applications with functional safety request.
The assessment of the safety functions accordingto EN13849 or EN 62061 must finally be done by the user.
Reinforced Insulation
Thermal sensors, motor holdingbrakes andfeedback systems built into the connected motor must have reinforcedinsulation (according to IEC61800-5-1) against system components with power voltage, accordingto the requiredapplication test voltage. All Kollmorgen com­ponents meet these requirements.
Never modify the drive!
It is not allowed to modify the drive hardware without permission by the manufacturer. Open­ing the housingcauses loss of warranty.
8 Kollmorgen | kdn.kollmorgen.com | Beta, December 2018

1.2.2 Use as Directed

The AKD2G drives are exclusively intended for driving suitablesynchronous servomotors with closed-loop control of torque, speed, and/orposition.
AKD2G arecomponents that arebuilt into electrical plants or machines andcanonly be oper­ated as integral components of these plants or machines. Themanufacturer of the machine used with a drive must generate a risk assessment for the machine. When the drives are built into machines or plant, the drive must not be used until it has been established that the machine or plant fulfills the requirements of the regional directives.
Cabinet and wiring
Drives must only be operatedin a closed control cabinet suitable for the ambient conditions (# 16). Ventilation or cooling may be necessary to keep the temperaturewithin the cabinet below 40°C.
Use only copperconductors for wiring. The conductor cross-sections can bederived from the standard IEC 60204 (alternatively for AWG cross-sections: NEC Table 310-16, 75°C column).
Power supply
The drives can be supplied by 1, 2 or3phase industrial supply networks. Drives in the AKD2G series can besupplied as follows:
AKD2G Product Safety Guide | 1 English
AKD2G-Sxx-6Vxx: 1, 2 or 3 phase industrial supply networks (not morethan 200 kA symmetrical ratedcur­rent at 120 V and 240 V). AKD2G-Sxx-7Vxx: 3 phase industrial supply networks (not morethan200 kA symmetrical rated current at 240V, 400 V and 480 V).
Connection to othervoltage types of supply networks is possible with an additional isolating transformer.
Repeated overvoltages betweenphases (L1, L2, L3)and the housing of the drive must not exceed1000V peak. In accordance with IEC 61800, voltagespikes (< 50 µs) between phases must not exceed 1000 V. Voltage spikes (<50 µs) between a phase and the housing must not exceed 2000 V.
EMC filter measures for AKD2G-Sxx-6Vxx must beimplemented by the user.
Motor voltage rating
The rated voltage of the motors must be at least as highas the DC bus link voltagedivided by √2 produced by the drive (U
nMotor
>=UDC/√2).
Functional Safety
Beta Drives: Safety functionality is neither approvednorcertified yet. Do not use this func­tionality in applications with functional safety request until furthernotice.
The network, to which the drive is connected, must besecuredaccording to state-of-the­art informationtechnology security requirements. The user IT specialists shall analyze whether furthersecurity requirements are applic­ableto ensure functional safety.
Review the chapter "Use as Directed" in the Functional Safety section beforeusing safety functionality.
Kollmorgen | kdn.kollmorgen.com | Beta, December 2018 9
AKD2G Product Safety Guide | 1 English

1.2.3 Prohibited Use

Otheruse thanthat described in chapter “Use as directed”is not intended and can lead to per­sonnel injuries andequipment damage. Thedrive may not be used with a machine that does not comply with appropriate national directives or standards. Theuse of the drive in the fol­lowing environments is also prohibited:
potentially explosive areas environments with corrosive and/or electrically conductive acids, alkaline solutions, oils, vapors, dusts ships or offshoreapplications
The drive must not be connected directly to the Internet. If the network, to which the drive is connected, is not secured according to state-of-the-art information technology, this could be a functional safety risk.
10 Kollmorgen | kdn.kollmorgen.com | Beta, December 2018

1.2.4 Warning note labels

If a warning note label is damaged, it must be replaced immediately.
1.2.4.1 Notes placed on the product
AKD2G
Wait 5 minutes
after removingpower
before servicing.
1.2.4.2 Adhesive label in the package
To meet UL, place the multi-language label onthedrive or on the panel near the drive.
AKD2G Product Safety Guide | 1 English
Kollmorgen | kdn.kollmorgen.com | Beta, December 2018 11
AKD2G Product Safety Guide | 1 English

1.3 Product life cycle handling

1.3.1 Transport

Transport the AKD2G in accordance with IEC 61800-2 as follows:
Transport only by qualifiedpersonnel in the manufacturer’s original recyclable packaging. Avoid shocks while transporting. Vibration/Shock: AKD2G is tested for environmental class 2M1 of IEC 60721-3-2. Store at or below maximum stacking height 8 cartons (see "Storage" (# 12)) Transport only within specifiedtemperature ranges:
-25to +70 °C, max. rateof change20 K/hour, class 2K3. Transport only within specifiedhumidity: max. 95% relative humidity at +40°C, nocondensation, class 2K3.
The drives contain electrostatically sensitive components that can be damagedby incorrect handling. Electrostatically dischargeyourself before touching the drive. Avoid contact with highly insulating materials, such as artificial fabrics and plastic films. Place the drive on a conductive surface.
If the packagingis damaged, check the unit for visible damage. Inform the shipper andthe manufacturer of any damageto the package or product.

1.3.2 Packaging

1.3.3 Storage

The AKD2G packagingconsists of recyclable cardboardwith inserts and a label on the out­side of the box.
Model Package
(mm) HxWxL
AKD2G-Sxx-6V03 to 6V12 tbd 4.2 AKD2G-Sxx-7V03 to 7V12 tbd 4.3
Matingconnectors are not included in the package of a standard drive. Matingconnectors are includedwhen the drive is ordered with accessories (append“-A” to
the model number).
Store the AKD2G in accordance with IEC 61800-2as follows:
Store only in the manufacturer’s original recyclablepackaging. Store at or below maximum stacking height 8 cartons. Store only within specified temperatureranges: -25 to +55 °C, max.rate of change 20K/hour, class 1K4. Storage only within specified humidity: 5 to 95% relative humidity, no condensation, class 1K3. Store in accordance with the followingduration requirements:
Less than 1 year: without restriction. More than 1 year: capacitors must be re-formed before setting up and operating the drive. Re-formingprocedures are describedin the Kollmorgen DeveloperNetwork (Forming).
Total Weight
(kg)
12 Kollmorgen | kdn.kollmorgen.com | Beta, December 2018

1.3.4 Installation, setup and normal operation

Installation and setup information aregiven in this Guide:
Mechanical installation(➜ # 20) Electrical installation (# 21) Setup (# 22)
Normal operationtested for environmental class 3K3 accordingto IEC 61800-2 (# 16). The manufacturerof the machine defines the necessary end userexpertise based onthe risk assessment for the machineand describes the requirements for normal operation based on the application.

1.3.5 Decommissioning

Only professional staff who are qualified in electrical engineering are allowedto decom­mission parts of the system.
DANGER: Lethal Voltages!
There is a dangerof serious personal injury or death by electrical shock or electrical arcing.
Switch off the mainswitch of the switchgearcabinet. Securethe system against restarting. Block the mainswitch. Wait at least 5 minutes after disconnecting.
AKD2G Product Safety Guide | 1 English

1.3.6 Maintenance and cleaning

The device does not require maintenance. Opening the device voids the warranty. Theinside of the unit can only be cleanedby the manufacturer.
Do not immerse orspray the device. Avoid that liquidenters the device.
To cleanthedevice exterior:
1. Decommission the device (see chapter1.3.5 "Decommissioning").
2. Casing: Clean with isopropanol or similarcleaning solution.
Caution : Highly Flammable! Risk of injury by explosion and fire.
Observe the safety notes given on the cleaningliquid package. Wait at least 30minutes after cleaning beforeputting the device back into operation.
3. Protective grill on fan: Cleanwith a dry brush.

1.3.7 Disassembly

Only professional staff who are qualified in electrical engineering are allowedto disassemble parts of the system.
1. Decommission the device (see chapter1.3.5 "Decommissioning").
2. Check temperature.
CAUTION: High Temperature! Risk of minor burns. During operation, the heat sink of
the drive may reach temperatures above 80°C (176°F). Before touching the device, check the temperature and wait until it has cooledbelow 40°C (104°F).
3. Remove the connectors. Disconnect the potential earth connection last.
4. Demount: loosen the fastening screws. Remove the device.
Kollmorgen | kdn.kollmorgen.com | Beta, December 2018 13
AKD2G Product Safety Guide | 1 English

1.3.8 System Repair

Only professional staff who are qualified in electrical engineering are allowedto exchange parts of the drive system.
CAUTION: Automatic Start! During replacement work a combinationof hazards and mul-
tiple episodes may occur.
Work on the electrical installation may only be performedby trainedandqualifiedper­sonnel, in compliance with the regulations for safety at work, and only with use of pre­scribed personal safety equipment.
Exchange of the device
Only the manufacturer can repair the device. Opening the device voids the warranty.
1. Decommission the device (see chapter1.3.5 "Decommissioning").
2. Demount the device (see chapter 1.3.7 "Disassembly").
3. Sendthedevice to the manufacturer.
4. Install a new device as described in this manual.
5. Setup the system as describedinthis manual.
Exchange of other drive system parts
If parts of the drive system (forexample cables) must be replaced, proceed as follows:

1.3.9 Disposal

1. Decommission the device (see chapter1.3.5 "Decommissioning").
2. Exchangethe parts.
3. Check all connections for correct fastening.
4. Setup the system as describedinthis manual.
To dispose the unit properly, contact a certified electronic scrap disposal merchant.
In accordance with the WEEE-2012/19/EC guideline and similar, the manufacturer accepts returns of old devices and accessories for professional disposal. Transport costs are the responsibility of the sender.
Contact Kollmorgen and clarify the logistics. Sendthedevices in the original packaging to the manufacturer address:
North America South America
KOLLMORGEN
201West Rock Road Radford, VA 24141, USA
Europe Asia
KOLLMORGEN Europe GmbH
Pempelfurtstr. 1 40880Ratingen, Germany
KOLLMORGEN
AvenidaJoãoPaulo Ablas, 2970 Jardim da Glória, Cotia – SP CEP 06711-250, Brazil
KOLLMORGEN
Floor 4, Building9, No. 518, North Fuquan Road, Changning District, Shanghai 200335, China
14 Kollmorgen | kdn.kollmorgen.com | Beta, December 2018

1.4 Technical description and general data

The AKD2G is a digital servo drive with extended functionality that is ideal for complex drive tasks with functional safety requirements.

1.4.1 Drive part number scheme

Use the part numberscheme forproduct identification only.
AKD2G Product Safety Guide | 1 English
Accessories
Model number followed by "-A" (Accessories)
Matingconnectors includedinthepackage.
SFA (Smart Feedback Adapter)
SFA converts conventional feedback signals to a 2-wire serial signal.
SDB Module (Safe Dynamic Brake Module)
Requiredfor SDB usage. When SDB is activated, the external Safe Dynamic Brake Module (SDB-Module) shorts the motor terminals.
Hybrid motor cables
Motorcables with integrated power, brake and feedback leads.
External regen resistors
High powerresistors for dissipationof generative energy.
Foraccessories referto yourregional Accessories Manual.
Kollmorgen | kdn.kollmorgen.com | Beta, December 2018 15
AKD2G Product Safety Guide | 1 English

1.4.2 Package Supplied

When a standard drive from the AKD2G series is delivered, the following items are included in the drive package:
AKD2G Printedcopy of AKD®2G Product Safety Guide . DVD with WorkBench setup software. Panel safety label
Matingconnectors are not included in the package of a standard drive. Matingconnectors are includedwhen the drive is ordered with accessories (append“-A” to
the model number). With the accessories option all connectors to match the drive variant are included, exceptingSubD (Feedback 3), RJ25 (CAN bus) and RJ45 (service and fieldbus networks).
Accessories Sold Separately
Accessories must beordered separately if required.
EMC filters for mains supply voltage, categories C2 or C3. External regen resistor. Connector kits Hybrid cable. Assembledhybrid motorcables are available for all regions. Motorcable. Assembled motor cables are available for all regions. Feedback cable. Assembled feedback cables areavailable for all regions. SFA (Smart Feedback Adapter) . SDB Module(Safe Dynamic Brake Module). Ethernet service cable.

1.4.3 Ambient Conditions, Ventilation, and Mounting Position

Storage, Transport (# 12) Normal operation Environmental class 3K3 accordingto IEC 61800-2 Surrounding tem-
perature in operation
Humidity in operation Relative humidity 5 to 85%, no condensation, IEC 61800-2class
Site altitude Up to 1000 m above mean sea level (AMSL): no restriction
Pollution level Pollution level 2 as perIEC 60664-1 Vibration Class 3M1according to IEC 61800-2 Shock Class L accordingto IEC 61800-2 Drive protection IP 20 according to IEC 60529 Drive EMC immunity Increasedimmunity according to EN 61800-5-2 Mounting Vertical position, in a cabinet with protection of at least IP 54 Ventilation Built-in fan in all drive variants
Internal regenresistor used:
0 to +40 °C under rated conditions +40 to +60 °C with current derating3 % perKelvin
Internal regenresistor not used:
0 to +50 °C under rated conditions +50 to +60 °C with current derating2 % perKelvin
3K3
1,000 to 2,000m AMSL: powerderating1.5%/100 m Maximum altitude: 2000m AMSL
The drive shuts down in case of excessively high temperaturein the control cabinet. Make sure sufficient forcedventilationis sup­pliedwithin the control cabinet.
16 Kollmorgen | kdn.kollmorgen.com | Beta, December 2018

1.4.4 Electrical Data

Electrical data (# 54)

1.4.5 Display, B1/2 push-buttons, S1/2 rotary switches

AKD2G with Safety Option 1 AKD2G with Safety Option 2 or 3
1.4.5.1 Display
The LCD display offers several screens, which can benavigatedby pushingtheB1 or B2 but­tons. Different colors visualize the current axis status.
AKD2G Product Safety Guide | 1 English
Kollmorgen | kdn.kollmorgen.com | Beta, December 2018 17
AKD2G Product Safety Guide | 1 English
1.4.5.2 Push-buttons B1 / B2
A short button press invokes the action correspondingto the symbol directly above the but­ton. On the dashboard for example,
a short press on B1 causes the menusystem to appear, and a short press on B2 causes a help screen to appear. A long press (greaterthan2seconds) onB2 returns the display to the previous screen.
More B1/B2 functions Description
Boot from SD card Push both buttons during power upto boot with data from SD
Boot from flash fallback image
1.4.5.3 Rotary switches S1 / S2
AKD2G with functional safety option 2 or 3 offertwo decimal rotary switches for setting the Safe ID. The SafeID is calculatedbasedon a fixed numberplus an adder set with the rotary switches.
card. Press the buttons first, thenhold it down while turning on the 24 V powersupply.
Push both buttons during power up, without an SD card, to boot from anon-boardrecovery image. Press the buttons first, then holdit down while turning onthe 24V powersupply.
Axis 1: 256 + adder1to 99, SafeID range257 to 355 Axis 2: 512 + adder1to 99, SafeID range513 to 611

1.4.6 Fault and Warning Messages

Fault codes and Warning codes follow the samefour digit code"G G X X", where GG is a two digit groupcode, and XX is a two digit ID. Thedisplay on the front panel of the drive shows the codeof the fault or warning that occurred for the axis. Navigate with B1 / B2 to the Fault screento see a short descriptionof the fault or warning.
Eliminate errors andfaults in compliance with work safety rules. Troubleshootingonly by qualified and trained staff.
More informationabout fault messages, remedy and clearingfaults can befoundin the WorkBench onlinehelp and in KDN.
18 Kollmorgen | kdn.kollmorgen.com | Beta, December 2018

1.5 Functional Safety

Beta Drives: Functionality Safety of AKD2G is neitherapprovednor certified. Do not use this functionality in applications with functional safety request.
There are three optional levels of Functional Safety implementation forAKD2G:
Option1 (SIL2 PLd): STO, activation by safe I/O Option2 (SIL3 PLe): STO, SS1-t, SBC, SBT, SDB, activation by safe I/O or FSoE Option3 (SIL3 PLe): STO, SS1-t, SS1-r, SS2, SLS, SSM, SSR, SDI, SLA, SAR, SLI, SLP, SCA, SBC, SBT, SDB, activation by safe I/O or FSoE
Resulting Functional Safety classification (SIL and/or PL level) must becalculated across the drive system.
The safety properties given by Kollmorgencan bereached if the Kollmorgen components are used. Refer to the matchingAKD2G-S Installation Manual for full information ontheinstalled functional safety option.
Parameterizing of the safety functions shall be doneby trained personnel only. The level of experience shall beappropriate tothecomplexity and safety integrity level of the drive sys­tem.
AKD2G Product Safety Guide | 1 English
CAUTION
Risk of electrical shock! The safety functions do not provide anelectrical separation from the poweroutput. If manual access to powerterminals is necessary,
disconnect the drive from mains supply, consider the discharging time of the DC-Bus link.
High electrical voltage!
Kollmorgen | kdn.kollmorgen.com | Beta, December 2018 19
AKD2G Product Safety Guide | 1 English

1.6 Mechanical Installation

Fordimensions and cabinet mountingsee(➜ # 60).
CAUTION
Risk of electrical shock, if drive (or motor)is not properly EMC-grounded.
Do not use painted (i.e. non-conductive) mounting plates. Observe the hints in chapter "Recommendations for EMI noise reduction"in the Install-
ation Manual
Protect the drive from impermissible stresses. In particular, do not let any components become bent or any insulation distances altered during transport and handling. Avoid con­tact with electronic components and contacts.
The drive will switch itself off in case of overheating. Ensure that there is an adequate flow of cool, filtered air into thebottom of the control cabinet, or use a heat exchanger.
Do not mount devices that produce magnetic fields directly beside the drive. Strong mag­netic fields can directly affect internal components. Install devices which produce magnetic field with distance to the drives and/orshieldthemagnetic fields.
Guide to Mechanical Installation
The following tools arerequired (at a minimum) to install the AKD2G; yourspecific install­ation may require additional tools:
M5 hexagon socket-cap screws (ISO 4762) 4 mm T-handle Allen key No. 2 Phillips headscrewdriver Small slotted screwdriver
High EMC Voltage Level!
Dimensions and mounting hole positions dependon the drive variant (# 60). Install the drive unit as follows:
1. Prepare the site. Mount the drive in a closed control cabinet, ambient conditions (# 16). Thesite must be free from conductive or corrosive materials. For the mountingposition in the cabinet see (# 60).
2. Check ventilation. Check that the ventilationof the drive is unimpeded, and keep within the permitted ambi­ent temperature(➜ # 16). Keep 50 mm space clearance above and below the drive.
3. Check cooling system. If cooling systems are usedfor the control cabinet, position the coolingsystem so that condensation water cannot driponto the drive or peripheral devices.
4. Mount the drive. Assemble the drive on the conductive, grounded mountingplate in the cabinet.
5. Ground the drive. ForEMC-compliant shieldingand grounding seeInstallation Manual. Ground the mounting plate, motor housing and CNC-GND of the control system andof the 24V DC supply voltage.
20 Kollmorgen | kdn.kollmorgen.com | Beta, December 2018

1.7 Electrical Installation

Connector position and wiring overview (# 61), connector pinout (# 67)
Only professional staff who are qualified in electrical engineering are allowedto install the drive. Wires with colorgreen with one ormore yellow stripes must not be used other thanfor protective earth (PE)wiring.
AKD2G Product Safety Guide | 1 English
DANGER
There is a dangerof serious personal injury or death by electrical shock or electrical arcing. Capacitors can still have dangerous voltages present up to 5 minutes after switchingoff the supply power. Control and power connections can still be live, even if the motor is not rotat­ing.
Only install and wire the equipment when it is not live. Make surethat the cabinet is safely disconnected (forinstance, with a lock-out and warn­ing signs). Never remove electrical connections to the drive while it is live. Wait at least 5 minutes after disconnecting the drive from the main supply power before touching potentially live sections of the equipment (e.g. contacts) or undoingany con­nections. To be sure, measure the voltage in the DC bus link and wait until it has fallen below 50 V.
Wrongmains voltage, unsuitable motoror wrong wiring will damage the drive. Check the combination of drive and motor. Compare the rated voltage and current of the units.
The fusingof the mains power, logic power and regenresistor must beinstalled by the user, best values (# 66). Excessively high external fusing will endanger cables and devices. Hints for use of residual-current circuit breakers (RCD) see Installation Manual.
The drive status shall bemonitored by the PLC to acknowledge critical situations. We recommend wiring theready to operate relay contact in series into the emergency off circuit of the installation. The emergency off circuit must operate the supply contactor.
Since the leakage current to PE is more than 3.5 mA, in compliance with IEC61800-5-1 the PE connection must either bedoubledor a connecting cable with a cross-section >10 mm² must be used. Use the PE terminal andthePE connection screws in order to fulfill this requirement.
High Voltage up to 900 V!
Guide to electrical installation
Install the drive electrical system as follows:
1. Select cables in accordance with IEC 60204 .
2. Install shieldingand groundthe drive. ForEMC-compliant shieldingand grounding, see Installation Manual. Ground the mountingplate, motor housing and CNC-GND of the control system.
3. Wire the drive and connectors.
Observe the "Recommendations for EMI noise reduction": see Installation Manual Connect all interface according to the connector pinassignments.
4. Check the wiringagainst the wiring diagram and connector pinassignments.
Kollmorgen | kdn.kollmorgen.com | Beta, December 2018 21
AKD2G Product Safety Guide | 1 English

1.8 Setup

Fordetailed information on the parameterization of functional safety refer to the AKD2G­S Installation Manual and the WorkBench Online Help.
Programmingparameters andcontrol loop behavior: see WorkBench online help. The fieldbus setup is describedin the corresponding manual on the DVD.
Only professional personnel with extensive knowledge in the fields of electrical engineering anddrive technology areallowed to test and set up the drive.
DANGER
There is a dangerof serious personal injury or death by electrical shock. Lethal danger exists at live parts of the device.
Built-in protection measures such as insulation orshielding may not be removed. Work on the electrical installation may only be performedby trainedandqualifiedper­sonnel, in compliance with the regulations for safety at work, and only with switched off mains supply, and secured against restart.
WARNING
Risk of death orserious injury for humans working in the machine. The drive might restart automatically after power on, voltage dipor interruption of the supply voltage, dependingon the parameter setting. If parameterAXIS#.ENDEFAULT is set to 1,
then place a warning sign ("WARNING: Possible Automatic Restart" or similar) to the machine. Ensure, that power onis not possible, while humans are in a dangerous zone of the machine.
CAUTION
Risk of minor burns. The heat sink of the drive can reach temperatures up to 80°C in oper­ation.
Check the heat sink temperaturebeforehandlingthe drive. Wait until the heat sink has cooled down to 40°C before touching it.
Lethal Voltage!
Automatic Restart!
High Temperature!
If the drive has been storedfor more than 1 year, you must re-form the capacitors in the DC bus link circuit. Re-forming procedures aredescribedintheKollmorgenDeveloperNetwork (Forming).
22 Kollmorgen | kdn.kollmorgen.com | Beta, December 2018
AKD2G Product Safety Guide | 1 English
MAC Address
The unique MAC address is pre-defined by the manufacturer (seenameplate).
Service IP Address
The AKD2G service port X20 supports auto-IP, DHCP andstatic IP addressing. The drive is delivered with IP address 0.0.0.0. Dependingon the connection (switch or PC)
either DHCP or auto-IP mechanism assignes a unique IP address. WorkBench uses the IP address to detect AKD2G devices in the LAN and start com-
munication. With WorkBench you canset a static IP address for thedrive (keyword IP.ADDRESS).
EtherCAT Node Address
The EtherCAT node address is set automatically by the EtherCAT master.
CAN Node Address
Set a CAN node ID for thedrive in WorkBench (keyword CANBUS.NODEID).
FSoE Address (Safe ID)
Functional Safety options 2 and3 offer FSoE support. Two rotary switches in the front are used to set the FSoE address of the drive. Default setting: S1 = 0, S2 = 1
S1 S2 Function Set while Remarks
x y FSoE address
Safe ID
24 V is OFF The SafeID is calculatedbasedon a fixed number
plus an adder set with the rotary switches. Example: Rotary switches: S1 = 2, S2 = 3 adder= 23
Resulting SafeID axis 1 : 256 + 23 = 279 Resulting SafeID axis 2 : 512 + 23 = 535
Kollmorgen | kdn.kollmorgen.com | Beta, December 2018 23