EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
DUT INFORMATION
Brand Kolink
Manufacturer (OEM) Kolink
Series
Model Number KL-G700FM
Serial Number KOL-018-0619000003
DUT Notes
DUT SPECIFICATIONS
Rated Voltage (Vrms) 100-240
Rated Current (Arms)
Rated Frequency (Hz) 50-60
Rated Power (W) 700
Type ATX12V
Cooling
Semi-Passive Operation ✗
Cable Design Fully Modular
Kolink KL-G700FM
120mm Sleeve Bearing Fan
(EFS-12E12H)
POWER SPECIFICATIONS
Rail 3.3V 5V 12V 5VSB -12V
Max. Power
Total Max. Power (W) 700
Amps 16 16 58 3 0.5
Watts 100 696 15 6
CABLES AND CONNECTORS
Modular Cables
Description Cable Count Connector Count (Total) Gauge In Cable Capacitors
ATX connector 20+4 pin (500mm) 1 1 18-22AWG No
4+4 pin EPS12V (650mm) 1 1 18AWG No
6+2 pin PCIe (600mm+100mm) 2 4 18AWG No
SATA (450mm+120mm+120mm) 2 6 20AWG No
SATA (450mm) / 4 pin Molex (+120mm+120mm) 2 2 / 4 20AWG No
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
PAGE 1/8
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
RESULTS
Test Date 08-05-2019
Certification Date 08-22-2019
Cybenetics ID # 789
Temperature Range (°C /°F) 30-32 / 86-89.6
Average Efficiency 88.970
Efficiency With 10W (≤500W) or 2% (>500W) Load -115V 58.362
Average Efficiency 5VSB 79.465
Standby Power Consumption (W) -115V 0.0877852
Standby Power Consumption (W) -230V 0.1389440
Average PF 0.990
ErP Lot 3/6 Ready ✓
(EU) No 617/2013 Compliance ✓
Avg Noise Output 21.60
Efficiency Rating (ETA) ETA-A
Noise Rating (LAMBDA) LAMBDA-A
Kolink KL-G700FM
TEST EQUIPMENT
Electronic Loads Chroma 63601-5 x4 Chroma 63600-2 x2 63640-80-80 x20 63610-80-20 x2
AC Sources Chroma 6530, Keysight AC6804B
Power Analyzers N4L PPA1530 x2
Sound Analyzer Bruel & Kjaer 2270 G4
Microphone Bruel & Kjaer Type 4955-A
Data Loggers Picoscope TC-08 x2, Labjack U3-HV x2
Tachometer UNI-T UT372 x2
Digital Multimeter Keysight U1273AX, Fluke 289, Keithley 2015 - THD
UPS CyberPower OLS3000E 3kVA x2
Transformer 3kVA x2
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
PAGE 2/8
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
EFFICIENCY GRAPH
Kolink KL-G700FM
INFO
This graph depicts the PSU’s efficiency throughout
its entire operational range. For the generation of
the efficiency and noise graphs we set our loaders
to auto mode through our custom-made software
before trying thousands of possible load
combinations
NOISE GRAPH
INFO
The PSU’s noise in its entire operational range and
under 30-32 °C ambient is depicted in this graph.
The X axis represents the load on the +12V rail(s)
while the Y axis is the load on the minor rails
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 3/8