All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
PAGE 1/9
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 2/9
info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
RESULTS
Test Date06-14-2019
Certification Date06-28-2019
Cybenetics ID #742
Temperature Range (°C /°F)30-32 / 86-89.6
Average Efficiency88.686
Efficiency With 10W (≤500W) or 2% (>500W) Load -115V56.837
Average Efficiency 5VSB77.773
Standby Power Consumption (W) -115V0.0998521
Standby Power Consumption (W) -230V0.1421750
Average PF0.986
AC SourcesChroma 6530, Keysight AC6804B
Power AnalyzersN4L PPA1530 x2
Sound AnalyzerBruel & Kjaer 2270 G4
MicrophoneBruel & Kjaer Type 4955-A
Data LoggersPicoscope TC-08 x2, Labjack U3-HV x2
TachometerUNI-T UT372 x2
Digital MultimeterKeysight U1273AX, Fluke 289
UPSCyberPower OLS3000E 3kVA x2
Transformer3kVA x2
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Chroma 63600-2 x2
63640-80-80 x20
63610-80-20 x2
PAGE 3/9
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
EFFICIENCY GRAPH
Kolink KL-G600FM
INFO
This graph depicts the PSU’s efficiency throughout
its entire operational range. For the generation of
the efficiency and noise graphs we set our loaders
to auto mode through our custom-made software
before trying thousands of possible load
combinations
NOISE GRAPH
INFO
The PSU’s noise in its entire operational range and
under 30-32 °C ambient is depicted in this graph.
The X axis represents the load on the +12V rail(s)
while the Y axis is the load on the minor rails
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 4/9
info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
5VSB EFFICIENCY -115V (ERP LOT 3/6 & CEC)
Test #5VSB
0.045A0.230
1
5.101V0.322115.13V
0.090A0.460
2
5.099V0.606115.13V
0.550A2.798
3
5.086V3.506115.13V
1.000A5.074
4
5.073V6.407115.13V
1.500A7.590
5
5.059V9.664115.13V
DC/AC
(Watts)
EfficiencyPF/AC Volts
71.429%
75.908%
79.806%
79.195%
78.539%
0.045
0.082
0.312
0.393
0.436
Kolink KL-G600FM
5VSB EFFICIENCY -230V (ERP LOT 3/6 & CEC)
Test #5VSB
0.045A0.230
1
5.101V0.409230.27V
0.090A0.460
2
5.099V0.718230.27V
0.550A2.798
3
5.086V3.754230.28V
1.000A5.075
4
5.074V6.789230.28V
1.500A7.590
5
5.059V9.689230.28V
DC/AC
(Watts)
EfficiencyPF/AC Volts
0.017
56.235%
0.030
64.067%
0.141
74.534%
0.222
74.753%
0.276
78.336%
6
3.001A15.051
5.016V19.345115.13V
VAMPIRE POWER -115V
77.803%
0.493
6
3.001A15.054
79.152%
5.017V19.019230.27V
0.364
INFO
This graph is generated by the PPA Standby Power
Analysis software which takes full control of the
power analyzer during the whole procedure. This
application features all of the EN50564 &
IEC62301 test limits for standby power software
testing
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 5/9
info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
EFFICIENCY UNDER HIGH AMBIENT TEMPERATURE
Kolink KL-G600FM
INFO
The PSU`s efficiency under high ambient
temperatures with 115V and 230V input. For this
graph the results of the 10-110% load regulation
table are used
5VSB EFFICIENCY
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
INFO
This graph depicts the efficiency levels of the 5VSB
rail with 115V and 230V input
PAGE 6/9
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
10-110% LOAD TESTS
Test
#
1
2
3
4
5
12V5V3.3V5VSB
3.171A1.982A1.951A0.988A60.152
12.156V5.048V3.382V5.063V72.39943.62°C115.13V
7.326A2.982A2.940A1.189A119.852
12.140V5.033V3.369V5.047V135.98444.72°C115.12V
11.853A3.487A3.425A1.391A179.747
12.127V5.021V3.357V5.032V200.29745.57°C115.12V
16.393A3.996A3.945A1.595A239.757
12.112V5.008V3.344V5.016V265.61546.46°C115.12V
20.613A5.010A4.955A1.800A299.851
12.096V4.993V3.330V5.000V332.31247.55°C115.12V
DC/AC
(Watts)
Fan
Efficiency
83.084%76714.5
88.137%77014.7
89.740%77414.8
90.265%77814.9
90.232%78315.0
Speed
(RPM)
PSU Noise
(dB[A])
Kolink KL-G600FM
Temps
(In/Out)
40.08°C0.957
40.75°C0.986
41.12°C0.982
41.76°C0.985
42.43°C0.989
PF/AC
Volts
6
7
8
9
10
11
CL1
CL2
24.845A6.030A5.972A2.008A359.949
89.862%99322.7
12.080V4.977V3.316V4.983V400.55648.54°C115.12V
29.060A7.057A7.000A2.216A419.663
89.288%144733.1
12.063V4.961V3.300V4.965V470.01249.25°C115.12V
33.356A8.091A8.034A2.426A480.178
88.618%183139.6
12.045V4.945V3.285V4.948V541.85150.31°C115.12V
37.986A8.620A8.556A2.431A539.485
88.077%184839.9
12.030V4.932V3.272V4.938V612.51651.47°C115.12V
42.465A9.155A9.118A3.057A599.903
87.358%185740.1
12.014V4.917V3.258V4.909V686.71753.63°C115.12V
47.522A9.177A9.149A3.063A659.932
86.709%186440.2
11.999V4.905V3.246V4.899V761.08955.54°C115.12V
0.147A12.001A11.999A0.000A101.948
83.153%83216.1
12.127V5.000V3.347V5.062V122.60347.65°C115.13V
48.010A1.002A1.001A1.000A591.238
88.456%185740.1
12.039V4.957V3.287V4.989V668.39953.88°C115.12V
42.63°C0.991
43.09°C0.993
43.75°C0.994
44.25°C0.995
45.53°C0.995
46.61°C0.996
42.78°C0.986
45.39°C0.995
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 8/9
info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
Top side
Power specifications label
LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
HOLD-UP TIME & POWER OK SIGNAL (230V)
Hold-Up Time (ms)19.80
AC Loss to PWR_OK Hold Up Time (ms)15.40
PWR_OK Inactive to DC Loss Delay (ms)4.40
Kolink KL-G600FM
CERTIFICATIONS
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 9/9
info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.