All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
PAGE 1/9
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
General Data
Manufacturer (OEM)Kolink
PCB TypeDouble Sided
Primary Side
Transient Filter5x Y caps, 3x X caps, 2x CM chokes
Inrush ProtectionNTC Thermistor & Relay
Bridge Rectifier(s)1xGBU1506 (600V, 15A @ 100°C)
APFC MOSFETS2x Advanced Power AP65SL380AI (650V, 6.5A @ 100°C, 0.38Ohm)
APFC Boost Diode1x Infineon IDH06G65C6 (650V, 6A @ 145°C)
Hold-up Cap(s)1x Teapo (420V, 330uF, 2000h @ 105°C,LG)
Main Switchers4x Great Power GPT10N50AD (500V, 9.7A, 0.7Ohm)
APFC ControllerOn Semiconductor NCP1654
Resonant ControllersChampion CM6901T6
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 2/9
info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
RESULTS
Test Date06-24-2019
Certification Date06-28-2019
Cybenetics ID #745
Temperature Range (°C /°F)30-32 / 86-89.6
Average Efficiency90.126
Efficiency With 10W (≤500W) or 2% (>500W) Load -115V52.396
Average Efficiency 5VSB76.252
Standby Power Consumption (W) -115V0.1008920
Standby Power Consumption (W) -230V0.1607280
Average PF0.933
AC SourcesChroma 6530, Keysight AC6804B
Power AnalyzersN4L PPA1530 x2
Sound AnalyzerBruel & Kjaer 2270 G4
MicrophoneBruel & Kjaer Type 4955-A
Data LoggersPicoscope TC-08 x2, Labjack U3-HV x2
TachometerUNI-T UT372 x2
Digital MultimeterKeysight U1273AX, Fluke 289
UPSCyberPower OLS3000E 3kVA x2
Transformer3kVA x2
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Chroma 63600-2 x2
63640-80-80 x20
63610-80-20 x2
PAGE 3/9
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
EFFICIENCY GRAPH
Kolink KL-G500FM
INFO
This graph depicts the PSU’s efficiency throughout
its entire operational range. For the generation of
the efficiency and noise graphs we set our loaders
to auto mode through our custom-made software
before trying thousands of possible load
combinations
NOISE GRAPH
INFO
The PSU’s noise in its entire operational range and
under 30-32 °C ambient is depicted in this graph.
The X axis represents the load on the +12V rail(s)
while the Y axis is the load on the minor rails
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 4/9
info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
5VSB EFFICIENCY -115V (ERP LOT 3/6 & CEC)
Test #5VSB
0.045A0.230
1
5.100V0.322115.12V
0.090A0.460
2
5.099V0.607115.12V
0.550A2.798
3
5.085V3.496115.13V
1.000A5.073
4
5.072V6.424115.12V
1.500A7.587
5
5.057V9.684115.12V
DC/AC
(Watts)
EfficiencyPF/AC Volts
71.429%
75.783%
80.034%
78.969%
78.346%
0.045
0.082
0.316
0.401
0.445
Kolink KL-G500FM
5VSB EFFICIENCY -230V (ERP LOT 3/6 & CEC)
Test #5VSB
0.045A0.230
1
5.101V0.388230.24V
0.090A0.460
2
5.099V0.687230.24V
0.550A2.798
3
5.085V3.768230.25V
1.000A5.074
4
5.073V6.805230.25V
1.500A7.588
5
5.058V9.659230.25V
DC/AC
(Watts)
EfficiencyPF/AC Volts
0.016
59.278%
0.029
66.958%
0.143
74.257%
0.224
74.563%
0.277
78.559%
6
3.000A15.041
5.013V19.365115.12V
VAMPIRE POWER -230V
77.671%
0.496
6
3.000A15.046
79.306%
5.015V18.972230.25V
0.367
INFO
This graph is generated by the PPA Standby Power
Analysis software which takes full control of the
power analyzer during the whole procedure. This
application features all of the EN50564 &
IEC62301 test limits for standby power software
testing
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 5/9
info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
EFFICIENCY UNDER HIGH AMBIENT TEMPERATURE
Kolink KL-G500FM
INFO
The PSU`s efficiency under high ambient
temperatures with 115V and 230V input. For this
graph the results of the 10-110% load regulation
table are used
5VSB EFFICIENCY
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
INFO
This graph depicts the efficiency levels of the 5VSB
rail with 115V and 230V input
PAGE 6/9
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
10-110% LOAD TESTS
Test
#
1
2
3
4
5
12V5V3.3V5VSB
2.310A1.984A1.940A0.988A49.753
12.188V5.040V3.401V5.062V60.83543.33°C230.28V
5.667A2.985A2.923A1.189A99.863
12.169V5.026V3.387V5.045V112.91344.45°C230.28V
9.361A3.492A3.407A1.392A149.752
12.151V5.013V3.375V5.030V165.57645.55°C230.28V
13.066A4.001A3.927A1.596A199.747
12.133V5.001V3.363V5.014V219.07446.28°C230.27V
16.458A5.017A4.928A1.801A249.864
12.113V4.985V3.348V4.997V273.63547.46°C230.28V
DC/AC
(Watts)
Fan
Efficiency
81.784%78515.1
88.442%79015.3
90.443%79915.5
91.178%108824.8
91.313%151033.7
Speed
(RPM)
PSU Noise
(dB[A])
Kolink KL-G500FM
Temps
(In/Out)
40.22°C0.741
40.64°C0.859
41.42°C0.912
41.92°C0.938
42.47°C0.953
PF/AC
Volts
6
7
8
9
10
11
CL1
CL2
19.858A6.040A5.940A2.009A299.957
91.116%186940.3
12.093V4.969V3.333V4.979V329.20348.20°C230.28V
23.269A7.067A6.963A2.218A350.069
91.041%187340.3
12.074V4.954V3.318V4.962V384.51949.83°C230.27V
26.695A8.103A7.994A2.428A400.175
90.813%187540.3
12.053V4.938V3.303V4.944V440.65850.87°C230.28V
30.527A8.632A8.509A2.433A449.873
90.628%187840.4
12.034V4.925V3.290V4.934V496.39451.95°C230.27V
34.141A9.166A9.066A3.059A499.887
90.276%188040.4
12.014V4.911V3.276V4.904V553.73453.49°C230.26V
38.365A9.187A9.095A3.065A549.902
90.049%188340.4
11.995V4.900V3.265V4.895V610.66955.27°C230.27V
0.142A12.002A11.998A0.000A101.736
83.052%187440.3
12.147V4.982V3.352V5.057V122.49747.76°C230.27V
41.010A1.002A1.000A1.000A506.653
91.515%188140.4
12.031V4.953V3.311V4.988V553.62753.48°C230.27V
42.90°C0.963
43.48°C0.969
43.95°C0.974
44.73°C0.977
45.67°C0.979
46.50°C0.982
42.54°C0.873
45.03°C0.979
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 8/9
info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
Top side
Power specifications label
LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
HOLD-UP TIME & POWER OK SIGNAL (230V)
Hold-Up Time (ms)20.40
AC Loss to PWR_OK Hold Up Time (ms)15.60
PWR_OK Inactive to DC Loss Delay (ms)4.80
Kolink KL-G500FM
CERTIFICATIONS
All dataand graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 9/9
info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
Loading...
+ hidden pages
You need points to download manuals.