Kolink KL-G500FM User Manual

EFFICIENCY AND NOISE LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
DUT INFORMATION
Brand Kolink Manufacturer (OEM) Kolink Series Model Number KL-G500FM Serial Number #CK035 DUT Notes
DUT SPECIFICATIONS
Rated Voltage (Vrms) 100-240 Rated Current (Arms) Rated Frequency (Hz) 50-60 Rated Power (W) 500 Type ATX12V
Cooling
Semi-Passive Operation Cable Design Fully Modular
Kolink KL-G500FM
120mm Sleeve Bearing Fan (EFS-12E12H)
POWER SPECIFICATIONS
Rail 3.3V 5V 12V 5VSB -12V
Max. Power
Total Max. Power (W) 500
Amps 16 16 41 3 0.5 Watts 100 492 15 6
CABLES AND CONNECTORS
Modular Cables
Description Cable Count Connector Count (Total) Gauge In Cable Capacitors ATX connector 20+4 pin (500mm) 1 1 18-22AWG No 4+4 pin EPS12V (650mm) 1 1 18AWG No 6+2 pin PCIe (600mm+100mm) 1 2 18AWG No SATA (450mm+120mm+120mm) 1 3 20AWG No SATA (450mm) / 4 pin Molex (+120mm+120mm) 2 2 / 4 18-20AWG No
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
PAGE 1/9
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted
info@cybenetics.com
EFFICIENCY AND NOISE LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
General Data
Manufacturer (OEM) Kolink PCB Type Double Sided
Primary Side
Transient Filter 5x Y caps, 3x X caps, 2x CM chokes Inrush Protection NTC Thermistor & Relay Bridge Rectifier(s) 1xGBU1506 (600V, 15A @ 100°C) APFC MOSFETS 2x Advanced Power AP65SL380AI (650V, 6.5A @ 100°C, 0.38Ohm) APFC Boost Diode 1x Infineon IDH06G65C6 (650V, 6A @ 145°C) Hold-up Cap(s) 1x Teapo (420V, 330uF, 2000h @ 105°C,LG) Main Switchers 4x Great Power GPT10N50AD (500V, 9.7A, 0.7Ohm) APFC Controller On Semiconductor NCP1654 Resonant Controllers Champion CM6901T6
Topology
Secondary Side
+12V MOSFETS 4x NexperiaPSMN2R6-40YS (40V, 100A @ 100°C, 5.3mOhm @ 175°C)
5V & 3.3V
Filtering Capacitors
Supervisor IC IN1S313I-DAG & UTC393 Fan Model DWPH EFS-12E12H (120mm, 12V, 0.50A, Sleeve Bearing Fan)
Primary side: Full-Bridge & LLC converter Secondary side: Synchronous Rectification & DC-DC converters
DC-DC Converters:4x Excelliance MOS EMB09N03HR (30V, 35A @ 100°C, 9.5mOhm) PWM Controllers: ANPECAPW7159
Electrolytics: 10x Teapo (1-3,000h @ 105°C, SC), 1x CapXon (2-5,000h @ 105°C, KF) Polymers: CapXon
Kolink KL-G500FM
5VSB Circuit
Rectifier 1x MBR2045CT SBR (45V, 20A) Standby PWM Controller Infineon ICE2QR4765
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted
PAGE 2/9
info@cybenetics.com
EFFICIENCY AND NOISE LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
RESULTS
Test Date 06-24-2019 Certification Date 06-28-2019 Cybenetics ID # 745 Temperature Range (°C /°F) 30-32 / 86-89.6 Average Efficiency 90.126 Efficiency With 10W (≤500W) or 2% (>500W) Load -115V 52.396 Average Efficiency 5VSB 76.252 Standby Power Consumption (W) -115V 0.1008920 Standby Power Consumption (W) -230V 0.1607280 Average PF 0.933
ErP Lot 6 2010: ✓
ErP Lot 3/6 Ready
(EU) No 617/2013 Compliance ✓ Avg Noise Output 28.65 Efficiency Rating (ETA) ETA-A Noise Rating (LAMBDA) LAMBDA-A-
ErP Lot 6 2013: ✓ ErP Lot 3 2014 & CEC: Partially
Kolink KL-G500FM
TEST EQUIPMENT
Chroma 63601-5 x4
Electronic Loads
AC Sources Chroma 6530, Keysight AC6804B Power Analyzers N4L PPA1530 x2 Sound Analyzer Bruel & Kjaer 2270 G4 Microphone Bruel & Kjaer Type 4955-A Data Loggers Picoscope TC-08 x2, Labjack U3-HV x2 Tachometer UNI-T UT372 x2 Digital Multimeter Keysight U1273AX, Fluke 289 UPS CyberPower OLS3000E 3kVA x2 Transformer 3kVA x2
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Chroma 63600-2 x2 63640-80-80 x20 63610-80-20 x2
PAGE 3/9
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted
info@cybenetics.com
EFFICIENCY AND NOISE LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
EFFICIENCY GRAPH
Kolink KL-G500FM
INFO
This graph depicts the PSU’s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
NOISE GRAPH
INFO
The PSU’s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted
PAGE 4/9
info@cybenetics.com
EFFICIENCY AND NOISE LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
5VSB EFFICIENCY -115V (ERP LOT 3/6 & CEC)
Test # 5VSB
0.045A 0.230
1
5.100V 0.322 115.12V
0.090A 0.460
2
5.099V 0.607 115.12V
0.550A 2.798
3
5.085V 3.496 115.13V
1.000A 5.073
4
5.072V 6.424 115.12V
1.500A 7.587
5
5.057V 9.684 115.12V
DC/AC (Watts)
Efficiency PF/AC Volts
71.429%
75.783%
80.034%
78.969%
78.346%
0.045
0.082
0.316
0.401
0.445
Kolink KL-G500FM
5VSB EFFICIENCY -230V (ERP LOT 3/6 & CEC)
Test # 5VSB
0.045A 0.230
1
5.101V 0.388 230.24V
0.090A 0.460
2
5.099V 0.687 230.24V
0.550A 2.798
3
5.085V 3.768 230.25V
1.000A 5.074
4
5.073V 6.805 230.25V
1.500A 7.588
5
5.058V 9.659 230.25V
DC/AC (Watts)
Efficiency PF/AC Volts
0.016
59.278%
0.029
66.958%
0.143
74.257%
0.224
74.563%
0.277
78.559%
6
3.000A 15.041
5.013V 19.365 115.12V
VAMPIRE POWER -230V
77.671%
0.496
6
3.000A 15.046
79.306%
5.015V 18.972 230.25V
0.367
INFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted
PAGE 5/9
info@cybenetics.com
EFFICIENCY AND NOISE LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
EFFICIENCY UNDER HIGH AMBIENT TEMPERATURE
Kolink KL-G500FM
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB EFFICIENCY
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
PAGE 6/9
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted
info@cybenetics.com
EFFICIENCY AND NOISE LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
10-110% LOAD TESTS
Test #
1
2
3
4
5
12V 5V 3.3V 5VSB
2.310A 1.984A 1.940A 0.988A 49.753
12.188V 5.040V 3.401V 5.062V 60.835 43.33°C 230.28V
5.667A 2.985A 2.923A 1.189A 99.863
12.169V 5.026V 3.387V 5.045V 112.913 44.45°C 230.28V
9.361A 3.492A 3.407A 1.392A 149.752
12.151V 5.013V 3.375V 5.030V 165.576 45.55°C 230.28V
13.066A 4.001A 3.927A 1.596A 199.747
12.133V 5.001V 3.363V 5.014V 219.074 46.28°C 230.27V
16.458A 5.017A 4.928A 1.801A 249.864
12.113V 4.985V 3.348V 4.997V 273.635 47.46°C 230.28V
DC/AC (Watts)
Fan
Efficiency
81.784% 785 15.1
88.442% 790 15.3
90.443% 799 15.5
91.178% 1088 24.8
91.313% 1510 33.7
Speed (RPM)
PSU Noise (dB[A])
Kolink KL-G500FM
Temps (In/Out)
40.22°C 0.741
40.64°C 0.859
41.42°C 0.912
41.92°C 0.938
42.47°C 0.953
PF/AC Volts
6
7
8
9
10
11
CL1
CL2
19.858A 6.040A 5.940A 2.009A 299.957
91.116% 1869 40.3
12.093V 4.969V 3.333V 4.979V 329.203 48.20°C 230.28V
23.269A 7.067A 6.963A 2.218A 350.069
91.041% 1873 40.3
12.074V 4.954V 3.318V 4.962V 384.519 49.83°C 230.27V
26.695A 8.103A 7.994A 2.428A 400.175
90.813% 1875 40.3
12.053V 4.938V 3.303V 4.944V 440.658 50.87°C 230.28V
30.527A 8.632A 8.509A 2.433A 449.873
90.628% 1878 40.4
12.034V 4.925V 3.290V 4.934V 496.394 51.95°C 230.27V
34.141A 9.166A 9.066A 3.059A 499.887
90.276% 1880 40.4
12.014V 4.911V 3.276V 4.904V 553.734 53.49°C 230.26V
38.365A 9.187A 9.095A 3.065A 549.902
90.049% 1883 40.4
11.995V 4.900V 3.265V 4.895V 610.669 55.27°C 230.27V
0.142A 12.002A 11.998A 0.000A 101.736
83.052% 1874 40.3
12.147V 4.982V 3.352V 5.057V 122.497 47.76°C 230.27V
41.010A 1.002A 1.000A 1.000A 506.653
91.515% 1881 40.4
12.031V 4.953V 3.311V 4.988V 553.627 53.48°C 230.27V
42.90°C 0.963
43.48°C 0.969
43.95°C 0.974
44.73°C 0.977
45.67°C 0.979
46.50°C 0.982
42.54°C 0.873
45.03°C 0.979
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted
PAGE 7/9
info@cybenetics.com
EFFICIENCY AND NOISE LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
20-80W LOAD TESTS
Test # 12V 5V 3.3V 5VSB
1.189A 0.495A 0.468A 0.196A 19.607
1
12.202V 5.055V 3.414V 5.093V 28.140 230.27V
2.437A 0.992A 0.968A 0.394A 40.025
2
12.194V 5.048V 3.407V 5.083V 49.648 230.27V
3.620A 1.489A 1.440A 0.592A 59.519
3
12.186V 5.041V 3.401V 5.073V 70.390 230.27V
4.873A 1.985A 1.945A 0.790A 79.939
4
12.178V 5.034V 3.395V 5.063V 91.924 230.27V
RIPPLE MEASUREMENTS
DC/AC (Watts)
Efficiency
69.677% 772 14.8
80.618% 776 14.8
84.556% 776 14.8
86.962% 781 14.9
Fan Speed (RPM)
PSU Noise (dB[A])
Kolink KL-G500FM
PF/AC Volts
0.554
0.693
0.771
0.822
Test 12V 5V 3.3V 5VSB Pass/Fail
10% Load 21.7 mV 9.1 mV 10.9 mV 19.4 mV Pass 20% Load 33.0 mV 9.7 mV 11.4 mV 11.3 mV Pass 30% Load 42.1 mV 10.3 mV 11.1 mV 11.3 mV Pass 40% Load 49.7 mV 10.5 mV 11.0 mV 12.6 mV Pass 50% Load 54.8 mV 12.0 mV 11.9 mV 12.4 mV Pass 60% Load 53.9 mV 13.2 mV 12.0 mV 11.6 mV Pass 70% Load 47.6 mV 13.0 mV 11.9 mV 12.0 mV Pass 80% Load 41.4 mV 13.6 mV 13.2 mV 12.5 mV Pass 90% Load 38.9 mV 14.8 mV 13.8 mV 12.9 mV Pass 100% Load 50.2 mV 16.3 mV 14.4 mV 13.5 mV Pass 110% Load 52.7 mV 17.2 mV 16.3 mV 14.3 mV Pass Crossload 1 39.7 mV 13.4 mV 17.0 mV 16.6 mV Pass Crossload 2 48.3 mV 14.0 mV 11.9 mV 23.0 mV Pass
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted
PAGE 8/9
info@cybenetics.com
EFFICIENCY AND NOISE
Top side
Power specifications label
LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
HOLD-UP TIME & POWER OK SIGNAL (230V)
Hold-Up Time (ms) 20.40 AC Loss to PWR_OK Hold Up Time (ms) 15.60 PWR_OK Inactive to DC Loss Delay (ms) 4.80
Kolink KL-G500FM
CERTIFICATIONS
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted
PAGE 9/9
info@cybenetics.com