Ice Machine
GT560
SHOWN WITH B400 BIN
GT560
Full Cube
1-1/4" x 1-1/4" x 1-1/4"
Half Cube
1-1/4" x 5/8" x 1-1/4"
The Classic
What you would expect from a Classic: high quality, lasting value, and beer ice.
e KOLD-DFT GT560 Classic Series produces up to 520 lbs. of KOLD-DFT’s
exclusive “square cube,” known for its perfect shape, purity, hardness, and slower melt rate.
at means it not only looks beer, but also lasts longer in storage bins, cocktail sinks,
drinks, salad bars, bags, and coolers. And KOLD-DFT equipment oers some of the best
recovery rates in the industry. You get more ice, more oen.
KOLD-DFT ice machines feature a unique “upside-down” horizontal evaporator and
water plate assembly. As water is sprayed upward into the evaporator cells, the pure water
freezes rst while particulates and air are forced out and dumped at the end of each cycle.
is leaves only perfect crystal-clear cubes, nearly as pure as distilled water.
e GT560 Series’ rugged unibody construction and time-proven design ensure reliable
operation, greater water eciency, and maximum ice-making capacity. Plus, they are energy
ecient, using environmentally friendly R-404A refrigerant. To facilitate maintenance,
the GT560 is serviceable from the front and is armed with our 5-year “bumper-tobumper” warranty on all parts and labor — the longest in the industry.
It’s NIce to be NotIced
™
1525 E. Lake Road • Erie, PA 16511 • 800.840.9577 • fax 800.548.9392 • www.kold-draft.com
General Specifications for GT560 Series
Plumbing:
3/8" FPT potable water inlet.
1" FPT bin drain.
3/4" I.D. flex tubing cuber drain.
3/8" FPT condenser (liquid-cooled) inlet.
1/2" FPT condenser (liquid-cooled)
outlet.
Exterior Finish:
300 Series stainless steel.
Refrigeration System:
Thermostatic expansion valvecontrolled R-404A-HFC.
Clearance Requirements:
Allow 4" left side, 4" right side and
back, and 1" top for ventilation and
utility connections.
Condenser Heat Rejection:
Recommended Operating Requirements:
Min. Max.
Room Air Temp. 45ºF (7ºC) 110ºF (43ºC)
Water Temp. 45ºF (7ºC) 90ºF (32ºC)
Voltage 208-230 198V 253V
115 104V 126V
Potable Water Pressure 20 PSIG (137 kPa) 100 PSIG (689 kPa)
Liquid-Cooled Condenser
Pressure 20 PSIG (137 kPa) 100 PSIG (689 kPa)
BTUH/kW/Ton
6,500/1.91/0.54 avg.
8,750/2.6/0.729 peak
GT560 Series Daily Capacities: Lbs. of ice per 24 hours per unit
Description Capacity and Energy Input Ratings
Model
Number
GT561AC
GT561AHK Half Cube 453 (205.44) 6.19 (491) 1 575 (260.81) 4.52 (358) 20.4 (1.7) n/a 18.6 30
GT561LC
GT561LHK Half Cube 500 (226.89) 4.85 (384) 1 580 (263.08) 4.07 (323) 17.1 (1.43) 175.9 (14.68) 17.7 30
GT564AC
GT564AHK Half Cube 433 (196.49) 5.99 (475) 1 550 (249.47) 4.37 (346) 18.4 (1.54) n/a 9.5 15
GT564LC
GT564LHK Half Cube 494 (224.26) 4.73 (375) 1 573 (259.90) 3.97 (315) 15.9 (1.33) 144.2 (12.03) 9.1 15
Note 1: 90/70 ratings based on 90°F (32.2°C) ambient and 70°F (21.1°C) water Standard Rating temperature operation. 70/50 estimated ratings based on 70°F (21.1°C)
ambient and 50°F (10°C) water Standard Rating temperature operation.
Note 2: Minimum circuit Amps does not supersede the minimum circuit rating required by any code regulation for the branch circuit supplying the ice maker.
Energy-performance data are derived from testing in accordance with AHRI 810 and CAN/CSA C742 Standards for Performance Rating of Automatic Commercial
Ice Makers and veried by Intertek/ETL.
All models are certied in compliance with ANSI/UL 563 and CAN/CSA C22.2 No. 120 Standards for Safety by Intertek/ETL.
Volt/
Hz/Ph Condenser
Air Cooled
115/60/1
Liquid
Cooled
Air Cooled
208-
230/60/1
Liquid
Cooled
Cube
Size
90/70
Ambient/Water
kWh/100#
(kJ/kg) Tier
70/50
Ambient/Water
Full Cube 369 (167.22) 6.63 (526) 1 458 (207.74) 5.04 (400) 16.6 (1.39) n/a 18.6 30
Full Cube 447 (202.56) 5.15 (408) 1 510 (231.33) 4.43 (351) 13.2 (1.1) 137.4 (11.47) 17.7 30
Full Cube 380 (172.19) 6.88 (545) 1 471 (213.64) 5.23 (415) 16.7 (1.39) n/a 9.5 15
Full Cube 429 (194.43) 5.14 (407) 1 489 (221.80) 4.42 (350) 16.9 (1.41) 175.6 (14.65) 9.1 15
1
Water Use1 gal/100# (l/kg)
kWh/100#
(kJ/kg) Potable Condenser
Min.
Circuit
Amps
2
Max.
Fuse
Amps
Please observe minimum circuit ampacity and maximum fuse size listed above. Fuse or HACR-type
circuit breaker branch circuit protection within the range of minimum ampacity and maximum fuse
size shall be provided or warranty may be voided. We reserve the right to make product
improvements at any time. Specifications and design are subject to change without notice.
Dimensions/Weight
Dimensions - inches (cm)
W D H
Condenser
Air Cooled 30.1 (76.5) 25.7 (65.3) 30.7 (78) 228 (103)
Liquid Cooled 30.1 (76.5) 25.7 (65.3) 30.7 (78) 218 (99)
Ship Weight
# (kg)
Quality US-Made Commercial Ice Machines ©2010 KDIndustries, Erie, PA Printed in U.S.A KD-LIT 03/10