Ice Machine
GB560
SHOWN WITH B650 BIN
GB560
Full Cube
1-1/4" x 1-1/4" x 1-1/4"
Half Cube
1-1/4" x 5/8" x 1-1/4"
The Signature
A lot of ice. A lot of options. e KOLD-DFT GB560 Signature Series is our most
popular line, producing up to 500 lbs. of ice per day. And, like all KOLD-DFT GB
units, the GB560 is stackable — allowing you to double the capacity in the same footprint.
KOLD-DFT equipment oers some of the best recovery rates in the industry, too. You
get more ice, more oen.
KOLD-DFT ice machines produce the only “square cube,” known for its perfect shape,
purity, hardness, and slower melt rate. at means it not only looks beer, but also lasts
longer in storage bins, cocktail sinks, drinks, salad bars, bags, and coolers. And all KOLDDFT ice machines feature a unique “upside-down” horizontal evaporator and water plate
assembly. As water is sprayed upward into the evaporator cells, the pure water freezes rst
while particulates and air are forced out and dumped at the end of each cycle. is leaves
only perfect crystal-clear cubes, nearly as pure as distilled water.
e GB560 Series’ rugged unibody construction and time-proven design ensure reliable
operation, greater water eciency and maximum ice-making capacity. Plus, they are energy
ecient, using environmentally friendly R-404A refrigerant. To facilitate maintenance,
the GB560 is serviceable from the front and is armed with our 5-year “bumper-tobumper” warranty on all parts and labor — the longest in the industry.
It’s NIce to be NotIced
™
1525 E. Lake Road • Erie, PA 16511 • 800.840.9577 • fax 800.548.9392 • www.kold-draft.com
General Specifications for GB560 Series
Plumbing:
3/8" FPT potable water inlet.
1" FPT bin drain.
3/4" I.D. flex tubing cuber drain.
3/8" FPT condenser (liquid-cooled) inlet.
1/2" FPT condenser (liquid-cooled)
outlet.
Exterior Finish:
300 Series stainless steel.
Refrigeration System:
Thermostatic expansion valvecontrolled R-404A-HFC.
Clearance Requirements:
Allow 4" left side, 8" right side and
back, and 6" top for ventilation and
utility connections.
Condenser Heat Rejection:
Recommended Operating Requirements:
Min. Max.
Room Air Temp. 45ºF (7ºC) 110ºF (43ºC)
Water Temp. 45ºF (7ºC) 90ºF (32ºC)
Voltage 208-230 198V 253V
115 104V 126V
Potable Water Pressure 20 PSIG (137 kPa) 100 PSIG (689 kPa)
Liquid-Cooled Condenser
Pressure 20 PSIG (137 kPa) 100 PSIG (689 kPa)
BTUH/kW/Ton
6,500/1.91/0.54 avg
8,750/2.6/0.729 peak
GB560 Series Daily Capacities: Lbs. of ice per 24 hours per unit
Description Capacity and Energy Input Ratings
Model
Number
GB561AC
GB561AHK Half Cube 428 (194) 6.6 (524) 1 544 (246.75) 4.82 (382) 25 (2.1) n/a 18.6 30
GB561LC
GB561LHK Half Cube 500 (227) 5.0 (397) 1 580 (263.08) 4.20 (333) 25 (2.1) 148 (12.4) 17.7 30
GB564AC
GB564AHK Half Cube 424 (192) 6.5 (516) 1 538 (244.03) 4.75 (377) 25 (2.1) n/a 9.5 15
GB564LC
GB564LHK Half Cube 460 (209) 5.2 (413) 1 534 (242.21) 4.37 (346) 25 (2.1) 165 (13.8) 9.1 15
Volt/
Hz/Ph Condenser
Air Cooled
115/60/1
208-
230/60/1
Liquid
Cooled
Air Cooled
Liquid
Cooled
Cube
Size
Full Cube 360 (163) 7.1 (563) 1 446 (202.30) 5.40 (428) 25 (2.1) n/a 18.6 30
Full Cube 420 (190) 5.5 (437) 1 479 (217.27) 4.73 (375) 25 (2.1) 142 (11.9) 17.7 30
Full Cube 357 (162) 7.2 (571) 1 443 (200.94) 5.47 (434) 25 (2.1) n/a 9.5 15
Full Cube 460 (209) 5.2 (413) 1 524 (237.68) 4.47 (354) 25 (2.1) 150 (12.5) 9.1 15
90/70
Ambient/Water
kWh/100#
(kJ/kg) Tier
70/50
Ambient/Water
1
kWh/100#
(kJ/kg) Potable Condenser
Water Use1 gal/100# (l/kg)
Min.
Circuit
Amp
2
Max.
Fuse
Amps
Note 1: 90/70 ratings based on 90°F (32.2°C) ambient and 70°F (21.1°C) water Standard Rating temperature operation. 70/50 estimated ratings based on 70°F (21.1°C)
ambient and 50°F (10°C) water Standard Rating temperature operation.
Note 2: Minimum circuit Amps does not supersede the minimum circuit rating required by any code regulation for the branch circuit supplying the ice maker.
Energy-performance data are derived from testing in accordance with AHRI 810 and CAN/CSA C742 Standards for Performance Rating of Automatic Commercial
Ice Makers and veried by Intertek/ETL.
All models are certied in compliance with ANSI/UL 563 and CAN/CSA C22.2 No. 120 Standards for Safety by Intertek/ETL.
Please observe minimum circuit ampacity and maximum fuse size listed above. Fuse or HACR-type
circuit breaker branch circuit protection within the range of minimum ampacity and maximum fuse
size shall be provided or warranty may be voided. We reserve the right to make product
improvements at any time. Specifications and design are subject to change without notice.
Dimensions/Weight
Condenser
Air Cooled 42.3 (107.4) 31.1 (79) 17 (43.2) 207 (94)
Liquid Cooled 42.3 (107.4) 25.63 (65.1) 17 (43.2) 185 (84)
Dimensions - inches (cm)
W D H
Ship Weight
# (kg)
Quality US-Made Commercial Ice Machines ©2010 KDIndustries, Erie, PA Printed in U.S.A KD-LIT 03/10