Ice Machine
GB1060
SHOWN WITH B950 BIN
GB1060
Full Cube
1-1/4" x 1-1/4" x 1-1/4"
Half Cube
1-1/4" x 5/8" x 1-1/4"
The Workhorse
High volume? No problem. e KOLD-DFT GB1060 Workhorse Series produces up to
1,000 lbs. of ice per day. And, like all KOLD-DFT GB units, the GB1060 is stackable —
allowing you to double the capacity in the same footprint. KOLD-DFT equipment oers
some of the best recovery rates in the industry, too. You get more ice, more oen.
KOLD-DFT ice machines produce the only “square cube,” known for its perfect shape,
purity, hardness, and slower melt rate. at means it not only looks beer, but also lasts
longer in storage bins, cocktail sinks, drinks, salad bars, bags, and coolers. And all
KOLD-DFT ice machines feature a unique “upside-down” horizontal evaporator and
water plate assembly. As water is sprayed upward into the evaporator cells, the pure water
freezes rst while particulates and air are forced out and dumped at the end of each cycle.
is leaves only perfect crystal-clear cubes, nearly as pure as distilled water.
e GB1060 Series’ rugged unibody construction and time-proven design ensure reliable
operation, greater water eciency, and maximum ice-making capacity. Plus, they are energy
ecient, using environmentally friendly R-404A refrigerant. To facilitate maintenance,
the GB1060 is serviceable from the front and is armed with our 5-year “bumper-tobumper” warranty on all parts and labor — the longest in the industry.
It’s NIce to be NotIced
™
1525 E. Lake Road • Erie, PA 16511 • 800.840.9577 • fax 800.548.9392 • www.kold-draft.com
General Specifications for GB1060 Series
Plumbing:
3/8" FPT potable water inlet.
1" FPT bin drain.
3/4" I.D. flex tubing cuber drain.
3/8" FPT condenser (liquid-cooled) inlet.
1/2" FPT condenser (liquid-cooled) outlet.
Exterior Finish:
300 Series stainless steel.
Refrigeration System:
Thermostatic expansion valve
controlled R-404A-HFC.
Clearance Requirements:
Allow 4" left side, 8" right side and
6" back, and 1" top for ventilation
and utility connections.
Condenser Heat Rejection:
BTUH/kW/Ton
Recommended Operating Requirements:
Min. Max.
Room Air Temp. 45ºF (7ºC) 110ºF (43ºC)
Water Temp. 45ºF (7ºC) 90ºF (32ºC)
Remote Condenser
Air Temperature -20ºF (-29ºC) 120ºF (49ºC)
Voltage 198V 253V
Potable Water Pressure 20 PSIG (137 kPa) 100 PSIG (689 kPa)
Liquid-Cooled Condenser
Pressure 20 PSIG (137 kPa) 100 PSIG (689 kPa)
13,850/4.06/1.15 avg.
18,000/5.3/1.5 peak
GB1060 Series Daily Capacities: Lbs. of ice per 24 hours per unit
Model
Number
GB1064AC
GB1064AHK
GB1064LC
GB1064LHK
GB1064RC
GB1064RHK
Description Capacity & Energy Input Ratings
Volt/
Hz/Ph Condenser
Air Cooled
208-
230/60/1
Liquid
Cooled
Remote
Air Cooled
Cube
Size
Full Cube 725 (329) 6.1 (484) 1 906 (411) 4.58 (363) 23 (1.9) n/a 16.3 25 n/a
Half Cube 823 (373) 5.6 (445) 1 1045 (474) 4.09 (324) 26.5 (2.2) n/a 16.3 25 n/a
Full Cube 835 (379) 4.46 (354) 1 952 (432) 3.84 (304) 16.1 (1.34)
Half Cube 900 (408) 4.6 (365) 1 1044 (473) 3.86 (306) 24 (2.0) 163 (13.6) 15.4 25 n/a
Full Cube 760 (345) 5.9 (468) 1 950 (431) 4.43 (351) 25 (2.1) n/a 18.1 30 RC214APV
Half Cube 850 (386) 5.6 (444) 1 1080 (490) 4.09 (324) 25 (2.1) n/a 18.1 30 RC214APV
90/70
Ambient/
Water
kWh/100#
(kJ/kg)2Tier
Ambient/
70/50
Water
1
kWh/100#
(kJ/kg)
Water Use1 gal/100# (l/kg)
2
Potable Condenser
141.8
(11.83)
Min.
Circuit
Amp
Max.
Fuse
2, 5
Amps
15.4 25 n/a
Required
Condenser
3, 4
Note 1: 90/70 ratings based on 90°F (32.2°C) ambient and 70°F (21.1°C) water Standard Rating temperature operation. 70/50 estimated ratings based on 70°F (21.1°C)
ambient and 50°F (10°C) water Standard Rating temperature operation.
Note 2: Remote Model ratings include condenser fan.
Note 3: Condenser fan motor is powered from the cuber. Interconnection wiring is provided by the installer.
Note 4: Cuber and condenser are provided with resealable quick-connect fittings for interconnecting refrigerant lines.
Line sets are ordered separately and must be specified according to required length.
Note 5: Minimum circuit Amps does not supersede the minimum circuit rating required by any code regulation for the branch circuit supplying the ice maker.
Energy-performance data are derived from testing in accordance with AHRI 810 and CAN/CSA C742 Standards for Performance Rating of Automatic Commercial
Ice Makers and veried by Intertek/ETL
All models are certied in compliance with ANSI/UL 563 and CAN/CSA C22.2 No. 120 Standards for Safety by Intertek/ETL
Please observe minimum circuit ampacity and maximum fuse size listed above. Fuse or HACR-type
circuit breaker branch circuit protection within the range of minimum ampacity and maximum fuse
size shall be provided or warranty may be voided. We reserve the right to make product
improvements at any time. Specifications and design are subject to change without notice.
Dimensions/Weight
Dimensions - inches (cm)
Condenser
Air Cooled 42.3 (107.4) 31.1 (79) 33.7 (85.6) 348 (158)
W D H
Liquid Cooled 42.3 (107.4) 25.7 (65.3) 33.7 (85.6) 312 (142)
Remote Air Cooled 42.3 (107.4) 25.7 (65.3) 33.7 (85.6) 335 (152)
RC Condenser Series
Model
Number
Description
RC214APV Single-circuit vertical air
flow remote condenser,
vapor-charged with resealable quick-connect fittings,
3, 4
Dimensions - inches (cm) Weight
W D H
40.75 (103.5)
including inter-
connect fitting
housing
for GB1064R Cubers
Ship Weight
# (kg)
gross # (kg)
22.75
(57.8)
30.2 (76.6)
including
160 (73)
10" (25.4 cm)
legs and fan
guard
Quality US-Made Commercial Ice Machines ©2010 KDIndustries, Erie, PA Printed in U.S.A KD-LIT 03/10