Kohler PW 1000/LT Series, PW1000/2200LT, PW1000/800LT, PW1000/1500LT User Manual

Kohler PW 1000/LT
(800–2200 VA)
Document Control
PDF ISSUE DATE REVISION SUMMARY
TS_602_00A 12/04/2018 First draft copy issued
TS_602_00 12/11/2018 First Issue
TS_602_01 20/03/2019 Kohler rebranding
Useful Contacts
www.kohler-ups.sg Kohler Uninterruptible Power web site
serviceups.sg@kohler.com Service department – booking service, fault reporting etc.
salesups.sg@kohler.com Hardware sales
All product, product specifications and data are subject to change without notice to improve reliability, function, design or otherwise. Kohler Uninterruptible Power has taken every precaution to produce an accurate, complete and easy to understand specification document and will assume no responsibility nor liability for direct, indirect or accidental personal or material damage due to any misinterpretation of, or accidental errors, in this manual.
© 2019 Kohler Uninterruptible Power
This manual may not be copied or reproduced without written permission of Kohler Uninterruptible Power.
1 Safety
This manual contains important safety instructions. Please read it thoroughly before you unpack, install or operate this UPS and keep it close to hand for future reference. Ensure you follow carefully the installation and set-up instructions
when you install the product.
WARNING: Risk of electric shock:
• The UPS power outlets can be electrically live even when the UPS is disconnected from the AC mains.
• DO NOT remove the UPS cover. The unit does not contain any user-serviceable components and if you remove the cover you will be exposed to potentially hazardous voltages.
• DO NOT insert any object into ventilation holes or other openings.
• The battery circuit is not isolated from the AC input and a hazardous voltage might exist between the battery terminals and ground (earth). When replacing the batteries always use insulated tools and check the terminal voltage.
WARNING: Battery safety:
• The UPS batteries contain lead and pose a hazard to the environment and human health if not disposed of properly. If you replace the batteries you must dispose of the used batteries in accordance with local environmental laws and regulations.
• Do not dispose of batteries in a fire as they might explode.
• Do not open or mutilate the batteries. They contain an electrolyte which is toxic and harmful to the skin and eyes.
• If electrolyte comes into contact with the skin, the affected area should be washed immediately with clean flowing water.
WARNING: General safety:
• To reduce the risk of fire, this equipment should be installed only in a temperature and humidity controlled indoor area free of conductive contaminants.
• In case of fire only use a dry power fire extinguisher. If you use a liquid fire extinguisher it may lead to an electric shock.
• All servicing must be performed by a qualified engineer approved by the manufacturer or its agent. Do not attempt to service the UPS yourself.
• Kohler Uninterruptible Power will assume no responsibility or liability for accidents or injuries due to the incorrect operation or manipulation of the UPS or peripheral equipment.
2 Introduction
Congratulations on your purchase of the Kohler PW 1000/LT UPS.
This line-interactive UPS system prevents your sensitive load equipment, such as a computer or other IT devices, from being affected by power transients, dips and surges that regularly appear on the utility AC mains supply. It will even maintain the supply to your load in the event of a complete AC mains supply failure (black-out) by operating on its internal battery. The UPS will produce its nominal 220/230/240 VAC output voltage ±10% over an AC mains voltage range of 160~290 VAC. If the input supply should fall outside this range the UPS will switch to battery operation automatically and the UPS output will be regulated at its nominal voltage.
The UPS is connected between your AC mains supply and load equipment and is simple to install and operate.
Kohler Uninterruptible Power specialises in the installation and maintenance of Uninterruptible Power Systems; and this UPS is just one example of our wide range of state-of-the-art power protection devices that will provide your critical equipment with a steady and reliable power supply for many years.
TS_602_01 PW1000/LT User Manual 20/3/19 1